HomeMy WebLinkAbout812 Shire Ct - Correspondence - 05/09/1995901939 012 4p f ['/,j� � / � �P.01 ( r wvn ..re bb! YtltlY C���'�_q�`. P 1 , 1 TOVNER CANPULD a Limitgd Liability Company CO,�I5UttTING STRUCTURAL $NGINEER9 447-2813 1528 SPRUCE STRUT BOULDER. COLORADO 80302 PAX (302) 667-2000 moiLB (303) 227-3684 Lt4 odsi:: • i »'� SAL NOIW 01 PAM INCLUDING Tole PAAE:--L_ Titifir wirL4 eon-" any undamtonding- and concurrence regarding a rooandfframing connectio sdetail tail oattthe he aW10x19aroof nboom ed nThe asfcllcws: The trusses spanning approximately 10 feet over the loft bear directly ^n top of the WIOx19. The 2 x I2 rafters spanning approzit Ily IB feet ever the living room do not bear on the top of the WSOx19 as shown on the drawings but are framed Into the face Of the W10x19 with a minimum of (3) 16d toe nails into each face of each " x 12. In addition, a 2 x 4 x 4,-o aide board is ,ae naiiea into each roof truss and Into the upper portion of each 2 it 12 ratter with a minimum of (6) 16d nails in each "aber. The calculated total roof load resisted by this rafter connection is either 45B rounds or 600 pounds, depending upon whether snow lend reductio: Is taken per the 88 UBO. In my opinion, the above-doeerlbed Connection should be adequate to resist this lead. sincere2 . M, Towner PrC AM «