HomeMy WebLinkAbout628 10th St - Correspondence/Engineering - 10/25/1999Weeks & Associates, Inc. Structural Engineers October 25, 1999 Fort Collins Housing Authority 1715 W. Mountain Ave. Fort Collins, Colorado 80521 Attn. Mr. Jim Kline Re: San Cristo PUD 2"d Filing Fort Collins, Colorado Project No. 99153 & -z8 / D 6 h Dear Mr. Kline As requested I have reviewed the structural capacity of the existing fence at the referenced site to resist wind loads. The fence is an 8' tall solid cedar fence with 3-2x6 rails and 4x6 posts at 6' on center. The posts are embedded in a 10" diameter by 4' deep concrete pier. Based on the existing construction and a 100-mile per hour wind it is my opinion additional posts are required to resist the wind load. It is recommended a 4x6 post be added between each existing post for a maximum post spacing of 3'. The post should be embedded in a 12" diameter by 4' deep concrete pier. If I can be of further assistance please contact me. Sincerely, , Weeks &Associates; 146.3'F ry G. Weeks P. E. , uctural Engineer Q l:idA Weeks & Associates, Inc. 417 Walker Way Fort Collins, CO 80525 (970) 669-5733