HomeMy WebLinkAbout607 Saint Michaels Dr - Correspondence - 02/02/1998February 2, 1998 Project No: 1207-40-98 Bonnema Construction Attn: Mr. Brian Bonnema P.O. Box 270921 Ft. Collins, Colorado 80527 Re: Lot 69, Huntington Hills Filing No. 5 607 St. Michaels Drive; Fort Collins, Colorado Dear W. Bonnema, Shear Engineering Corporation was present during caisson drilling and concrete placement for the above referenced site on Friday, January 30, 1998. The soils within the excavation were noted at this time. The soils noted at the bottom of the basement excavation, and throughout the excavation, consisted primarily of claystones and weathered claystones. The soils noted are generally consistent with those noted by Earth Engineering Consultants in their geotechnical investigation report for the Huntington Hills Filing No. 5 area titled Subsurface Exploration Report for Huntingt6n Hills P.U.D. 5th filing. A caisson type foundation was recommended for this area. Groundwater was not evident in the excavation. Waterproofing is not required. At a minimum, all foundation walls shall be dampproofed to within 12" of the proposed finished grade according to the requirements of "91 UBC, Appendix Chapter 29, Waterproofing and dampproofing foundations. A foundation drain system will be required. A sump pit to be located in the basement is recommended as a secondary drain outfall. Caisson construction was performed in substantial conformance with the foundation plan for this residence which was prepared by Shear Engineering Corporation. Concrete was placed immediately after drilling. If you have any questions concerning our caisson construction observations, please call at (970) 226-5334. Brian W. Shear, P.E. Shear Engineering Corporation BW S / mers 4836 S. College, Suite 12 Ft. Collins, CO 80525 (970) 226-5334 FAX (970) 282-0311 ........................ Fort Collins residential energy code 7/96 ''-Mechanical systems disclosure form Job address: '-, General contractor Mechanical contractor. Space -heating ""�**'s-ys*"ie'-'m�-::7:'-----.7 yste.m.l........ Water heating system Certification UWe certify that the above4sted equipmentwas installed in the building at tte above locations in conformance with the current requirements of the C4 Of Fort Collins Residential Energy Code and Mechanical Code, and that it was installed in accordance with manufacturer's instructions INVe certify that any ductwark has been installed in conformance with the cuirrent requirements of the City of Fort Collins Residential Energy Code and Mechanical Code. Certified by: Robert Miller Phone.- 970-223-8873 Business firm: Northern Colorado Air, IncDate.- .............. Address: 1823 E. Harmony Pd. Signature: ............ Instructions - ............ ................. . ... .... ........... . . .. . . .. . ......... . ..... .. .. . ... ...... ........ This dsc!csurefcrm is to be signed by.- the mechanical dontractor or representative of the general contractor. . .................... Please type or print except for the signature. If there are multiple systems serving any function, make multiple entries to describe them. One copy of this form shag be provided to the Suilding and Zoning (Department at final inspection. One copy of this form shad be provided to the homebuyer.