Loading...
HomeMy WebLinkAbout601 Flagler Rd - Disclosures/Final Energy - 09/28/1999Charles Lucas Lucas Energy Audits 3621 Dalton Drive Fort Collins, Colorado 80526 970-229-9678 Dace of Test: 09/28/99 Test File: 601flagier Technician: Charles Lucas Customer: Ken BronSeR Building Address; 601 Flagler Bronsert Homes Fort Collins, Colorado 4131 Saddlenctch Drive Fort Collins, Colorado 80526 970-229.9696 f ST g ITS: Airflow at 50 Pascals: 1835 CFM ( +/- 0.4 %) (50 Pa = 0.2 w.C.) 3.78 ACH Leakage Areas; 186.3 In2 ( +/• 1.9 %) Canadian Equiv. L.A. 0 30 Pa 98.i In2 ( +/- 3.0 %) LBL Effective L.A. 9) 4 Pa Minneapolis Leakage Ratio: Building Leakage Curve: Flow Coefficient (C) = 138.5 (+/ 4.6 %) Exponent (n) = 0.561 ( +/• 0.013 ) Correlation Coefficient = 0."872 Test Standard: CGSS Test Mode: Depressurization Equipment: Model 3 Minneapolis Blower Door, S/N Estimated Average Annual Infiltration Rate: Estimated Design Infiltration Rate, winter: 165.8 CFM 0,34 ACH Summer: 94.2 CFM 0.19 ACH Recommended Minimum Ventilation Guideline: 170.0 CFM (based on ASHRAE 62.89 and 136-93) 09/2B/1999 19:04 9702061557 LUCAS ENERGY AUDITS PAGE 02 RMLDING LEAMGE TEST (Dfi011ad Raoort) Peme 2 Date of Test: 09/28/99 Test File: 601flagler Rt ZLDING CONDITIONS inside Temperature: 65 deg F Heating Fuel: Gas Outside Temperature: 38 deg F Heating Fuel Cost: $0.44/ccf # of stories 2.0 Heating Efficiency: 80.00 Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: $0.070/kwh * of Occupants 4.0 Cooling SEER: 10.0 Cooling Degree Days: 287 * or Bedrooms: 3.0 Volume: 29137 ft3 Ventilation Weather Factor: 0.87 Surface Area: Energy Climate Factor: 17.0 Floor Area: Design Winter Wind Speed: 9.0 mph Design Winter Temp DNf: 69 deg F Design Summer Wind Speed: TO mph Design Summer Temp DUft 16 deg F