HomeMy WebLinkAbout532 Shadbury Ct - Correspondence - 01/01/2000t 01/26/1999 10:43 9401718 GEI PAGE p? Structural Engineers Gerard Enterprises, Inc. 6355 Ward Road, Suite 214 January 26, 1999 Arvada, CO 80004 Mr. Paul McWilliams Engle Homes Colorado 7340 East Caley Avenue, Suite 300 Englewood, co 80111 Subject: Field Modification of Existing Plan 2075 walkout Basement 532 shadbury - Lot 114, Huntington Hills Subdivision, Fort Collins, Colorado GET Job No. 99168 Dear Paul: Framing Filing No. 6 (303) 940-0996 Fax (303) 940-1718 Pager (303) 230-2667 At your request, we reviewed the subject plans for changes made in the foundation details. Following is our understanding of the changes and recommendations. There were two changes reported in the foundation details at the subject site. The first change was at the support for the steel beams in the basement floor. framing. The specified embedded plates at the foundation wails were changed to steel saddles mounted to the face of the foundation wall. The second change was that the basement floor ledger detail was changed. The specified ledger supported by a "Uni- Strut- embedded in the foundation wall was deleted, The installed condition was reported to be an embedded two by ledger with two rows of 20d nails at twelve inches on center to t e'contrete, The saddles were attached to the foundation wall with four 112" diameter expansion bolts. The expansion. bolts should consist of Hilti "Kwik-Bolts" or equal and embedded at least three and one half inches into the foundation wall. We have enclosed a detail for our standard steel saddle and a corner saddle supplied to our office that are reportedly used at corner conditions. 01/26/1999 10:43 9401718 GEI PAGE 03 page no. 2 (GEI Job No. 99160) The floor ledger was reportedly changed to an embedded ledger. The embedded ledger reportedly consists of a two by t itt; r0 rows of 20d nails at twelve inches on center spiked into the a ger on the face in concrete. The basement floor foists are reportedly attached to the ].edger_ with standard joist hangers. It is our opinion, the reported conditions will be structurally adequate provided that the details are correctly installed. If there are any questions or if we may be of further service, please call. -j0 A. Meiser, 01/26/1999 10:43 9401718 GEI PAGE 04 .. 5+�'i•• I � 4 oc P i PD �( cut�iiw J LLJ > _j Q►JiCM �IW3 ca III 01/26/1999 10:43 9401718 GEI PAGE 05 ,1 a06-1@-Q1 11 :23P -own I - a. yr r B9/16/1999 BB:37 3e37ao611a ppES FMMIN13 P . 02 x �Q` xr ����� •P` ( i y .. •Y �•.ice. y}I ' •'. s..-.$y�/ � till iy '. 1:'. ,� I s 1/4 1i 4" x 47 . • ., ,' ' 0