Loading...
HomeMy WebLinkAbout520 N Sherwood St - Disclosures/Blower Door Test - 04/27/1999 (3)Fort Collins Residential Energy Code AIR SEALING DISCLOSURE FORM - 'Not eppllcable to E-STAR or ENERGY SCORE rated homes) Job address: 520 N. Sherwood #33 Sovick Design Builders General contractor. Air sealing contractor: Gale Insulation the building & zoning dept. of Community Planning and Environmental Service 281 N. C01e9e Ave., P.O. Box 580, Fort CoWns, CO 80522 Voice: 970 2215760 FAX 970 224 (5t 34 I n s trta;ctt ons.:.. :::::•:.>;:;:::.:•;::....... :;:::;:;::::::::.:::::........ . Complete either Part A or Part B . Part A is to be signed by the air sealing contractor or representative of the general contractor. Part B is to be signed -by the biowet'door testing contractor or representative of the general contractor. The "Blower Door Test Report" or equivalent documentation must be attached. Please type or print, except for the signature. if components vary, make multiple entries to describe them. One copy of this form must be provided to the Building and Zoning Department prior to C. O. One copy of this form must be provided to the original home buyer. A. Prescriptive pathAtr Seahn ChtsaklTst� IfWe certify that the s1r sealing requirements specified in the current City of Fort Collins Residentaal Energy Code have been completed in thts building, In accordance with the "Air Sealing Checklist' published by the City of Fort Collins. Person Certifying Job: Jim Young -oignatu Buslnes Address: r_a1P Tn-,ulation 2016 E. Lincoln Ave., Unit A Fort Collins,CD 80524 Date: 4/27/99 Phone: 970-224-1539 .......... ..... .......:..::.:.....;.;:.. ..•:.::.:•:.: :•::: :•:: a::::.. B. Performanc.e.}�th,(iotiti' AA;Qt'T St);<,:;• ::::.:.::......... tlWe certify that this building has met the air leakage performance threshold specified In the current Fort Collins Residential Energy Code, In accordance with the "Blower Door Test Procedures' published by the City of Fort Collins. Testing contractor. Date of test: CFM50: Volume: ACH50: Person Certifying Job: ature: --iusiness Firm: Address: Alt now through the blower door at 50 Pascale pressure difference (dm) Volume of home (cu. ft.) Alr change rate per hour at 50 Pascals pressure difference ACH50 ■ (CFM50 x 60)1 Volume The performance threshold for code comptlance Is ACH50 not exceeding 6.0 sc/h Date: Phone: Fort Collins residential energy code 7/96 Insulation disclosure form Job address: 520 N. Sherwood #33 General contractor: Sovick Design Builders Insulation contractor: Gale Insulation Certification _ .. 'NN,Csrt;ry Ithat the above-Usted Insulation waa Installed In the bulwing at the above "lone In conformance with lie c un ent requirements of the City of Port CoWne Rasldantlal Energy Cods, and that h was Installed In accordance with the eppLcabia 'Insulation In6WIadon Guldellnei published by the City of Fort Collins. Certified by: Jim Young Phone: Business firm: Gale Insulation Date: Address: 2016 E. Lincoln Ave. , UnitA 'Signature: 970-224-1539 4 27 99 Fort... Collins, CJ 30524 Instructions Thu disclos.ue form is to be signed by UN VAulawn contractor or represanlative or the ganaral contractor. please t,-ps or print, eaccpt for the algnatura. II components vary, make murilpla antrles to deautbe thorn. One copy of "s form Snell be provldsd to the BuOding utd Zoning Dapartmant at ruin ""action. One copy of Uus form Mall be provided to the homabuyar, RICHMOND ASSOCIATES 420 W. OAK STREET DATE FT. COLLINS, CO 80521 06/03/99 (970) 224-3140 CUSTOMER: Sovick 520 North Sherwood #33 Fort Collins Co ING CONDITIONS: Interior Temp = 65 F Exterior Temp = 82 F Volume = 15680 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants =(74) Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 67 40 1139 —0.2 Ring A 60 32 1020 —1.5 Ring A 53 28 955 2.8 Ring A 45 20 808 0.6 Ring A 37 13 653 —3.5 Ring A 32 11 601 1.1 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9961 C = 27.95 n = 0.882 Results: Air Flow @ 50 Pascals : 882 CFM50 +/— 0.9% 3.37 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 26.92 Square Inches +/— 10.1% Equivalent Leakage Area (CANADA) = 62.60 Square Inches +/— 6.6% Estimated.Natural Infiltration (50 Pascal Flow Divided By 13.6) 65 CFM = 16.2 CFM/OCCUPANT E- = 0.25 AIR CHANGES PER HOUR