HomeMy WebLinkAbout5120 Stetson Creek Ct - Miscellaneous - 05/07/2000MAY-30-00 TUE 10:15 AM WRITER NORTHERN FAX NO. 970 613 0043 P. 05
SENT BY: WRITER 9ADDLBROOK TONMHOUrs; 970 223 3408 ; M0-30-00 9:5iAM; PAGE 1/i
Bara's Energy Scoring
2115 Water Blossom X44
DATE FT. COLLINS, CO SOS26
05/07/00 (970) 266--1009
XSTOMERa Writer
5120 Stetson Creek I'd"
Ft. Collins Co
3UILDING CONDXTIONS:
interior Temp = 55 F Exterior Temp o 65 F
Volume - 19200 Cu. Vt. Above Grade Surface Area = 0 Sq. Ft.
Number of Stories 2 Number of Occupants = 2
Wind Shield Factor = 1
HOUSE TIST = Depressurized
Iran Model + 3
Performed By SARA
Data Pointe:
House Pressure
Fan Pressure
CFM
%Error
Fan Configuration
54
170
771
--0.7
Ring B
44
143
704
0.2
Ring B
33
110
619
1.2
Ring B
24
00
526
0.6
Ring B
19
62
463
-0.9
Ring B
13
43
384
-0.9
Ring B
Correlation Coefficient Flow Coefficient
Exponent
x - .9993
C =
111.21
a µ 0.407
Results:
Aix Flow 1 50 Pascals t
e 748 CFfL90 -+-Cha ( �G��J
(Air Changes Per Hour
Effective Leakage Area (LBI.) 61.94 Square Inches 2.0%
Equivalent Leakage Area (CANADA) 100.27 Square inches +/- 1.2%
Estimated Natural Infiltration (50 Pascal now Divided By 13.6)
• 53 CrK
- 27.6 CPM/OCCUPANT
= 0.17 AIR CHANGES PER HOUR