Loading...
HomeMy WebLinkAbout5120 Stetson Creek Ct - Miscellaneous - 05/07/2000MAY-30-00 TUE 10:15 AM WRITER NORTHERN FAX NO. 970 613 0043 P. 05 SENT BY: WRITER 9ADDLBROOK TONMHOUrs; 970 223 3408 ; M0-30-00 9:5iAM; PAGE 1/i Bara's Energy Scoring 2115 Water Blossom X44 DATE FT. COLLINS, CO SOS26 05/07/00 (970) 266--1009 XSTOMERa Writer 5120 Stetson Creek I'd" Ft. Collins Co 3UILDING CONDXTIONS: interior Temp = 55 F Exterior Temp o 65 F Volume - 19200 Cu. Vt. Above Grade Surface Area = 0 Sq. Ft. Number of Stories 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TIST = Depressurized Iran Model + 3 Performed By SARA Data Pointe: House Pressure Fan Pressure CFM %Error Fan Configuration 54 170 771 --0.7 Ring B 44 143 704 0.2 Ring B 33 110 619 1.2 Ring B 24 00 526 0.6 Ring B 19 62 463 -0.9 Ring B 13 43 384 -0.9 Ring B Correlation Coefficient Flow Coefficient Exponent x - .9993 C = 111.21 a µ 0.407 Results: Aix Flow 1 50 Pascals t e 748 CFfL90 -+-Cha ( �G��J (Air Changes Per Hour Effective Leakage Area (LBI.) 61.94 Square Inches 2.0% Equivalent Leakage Area (CANADA) 100.27 Square inches +/- 1.2% Estimated Natural Infiltration (50 Pascal now Divided By 13.6) • 53 CrK - 27.6 CPM/OCCUPANT = 0.17 AIR CHANGES PER HOUR