Sara's Energy Scoring
2115 Dates' Blossom LN
DATE FT, COLLINS, CO $0526
05/07/00 (970) 266-1009
XSTOMERs Writer
5120 Statsvn Crook "a"
Ft. Collins CO
9UILDINO CONDITIONS:
Interior Temp = 65 F Exterior Tamp - 65 P
volmmo - 19200 Cu. rt, Above (Grads SurfACe Area • 0 Sq. Ft.
Number of Stories = 2 Number of Occupants - 2
Wind Shield Factory 1
iOUSE TE pressur zea
Part Model a 3
Performed By sAU
)ate Points:
Sousa Pressure
Pan Pressure
CFK
%Error
?An Configuration
53
160
748
-1.8
Ring B
47
151
726
1.3
Ring B
37
120
646
2.6
Ring B
30
95
574
0.3
Ring 8
25
77
516
-1.2
Ring R
17
53
427
-0.7
Ring B
Correlation Coefficient
Flow Coefficient
Exponent
r a .9968
C-
103.92
n i 0.502
Aftults:
Air Flow 9 50 Pascals
�-"-.•.740�E'3[.`1Q +L _Quit -
2.31 ACH56 ( Air Changes Per Hour)
Effective Leakage Area (LBL) = 4 59.06 Squ re Inches +/- 4,54
Equivalent Leakage Area (CANADA) - 96.68 Square Inches t/- 2.74
Estimated Natural Infiltration (50 pascal -plow Divided By 13.6)
54 CPU
27.2 CFX/OCCUPANT
w 0,17 AIR CRAMS PSA HOUR