Loading...
HomeMy WebLinkAbout5115 Stillwater Creek Dr - Miscellaneous - 06/07/2001JUN-15-01 FRI 07:42 AM WRITER NORTHERN FAX NO. 970 613 0043 P. 05/05 May 24 01 01:58p SRRn (9701 266 - 1009 p.6 SARAIS ENERGY SCORING 1225 W Prospect P-14 DATE FT. COLLINS CO 60526 06/07/01 (970)495-9922 CUSTOMER: Writer `V._ ' 5115 Still crater Creek c Ft. Collins Co BUILDING CONDITIONS: Interior Temp = 70 P Volume = 16400 Cu. Ft. Number of Stories = 2 Wind shield pactor 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: Exterior Tamp - 65 F Above Grade Surface Area = 0 sq. Ft. Number of Occupants = 2 House Pressure Fan Pressure CFM %Error Fan Configuration 56 260 952 -0.7 Ring B 50 237 908 -1.3 Ring B 42 222 879 1.7 Ring B 33 186 803 1.5 Ring B 26 155 732 0.9 Ring B 20 120 643 -2.7 Ring B Correlation Coefficient Flow Coefficient 8xponent x a .9931 C = 223.73 n = 0.361 Results: Air Floor @ 50 Pascals : = 920 CPM50 +/- 0.9w = 3.36 ACK50 (Air Changes Per hour) Effective Leakage Area (LBL) - 104.67 Square inches ;/- 4.99 Equivalent Leakage Area (CANADA) = 150.99 Square inches +/- 3.0% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) 68 CFM 33.9 CFM/OCCUPANT 0.25 AIR CHANGES PER SOUR