HomeMy WebLinkAbout5114 Stetson Creek Ct - Miscellaneous - 05/09/2000 (2)MAY-26-00 FRI 03:28 PM WRITER NORTHERN FAX NO. 970 613 0043 P. 07
SENT BY: WRTTER SADOLUROOK TOWNAWS; 076 223 $408 ; MAY-2,�.A0 1:26PM; PAGE 1
Sera's Energy Scoring
2113 Water Blossom LN
RATE ":. OLUIN$P CO- 90524
05/09/00 (970) 266-1009
CUSTOMER: Writer
5114 STmc)X CREEK, -A"
rt. Collins CO
BUILDING C ND IONS:
Interior Tamp - 65 F Exterior Temp - 55 F
Volume - 19200 Cu. Ft. Above Grade Surface Area - O Sq. Ft,
Number of Stories 0 2 Number Of OCcuparts - 2
Wind Shield Factor - 1
MUSE TEST : Depresauriz
Fan Model a 3
Performed BY SARA
Data Points:
House Pressure
S2
Fan Pressure CFM
%Error
Fan Configuration
49
171
157
765
734
-1.0
0.4
Ring B
43
36
125
654
1.4
Riag S
Ring B
27
86
50
541
-0.5
Ring B
21
31
411
323
-0.3
-0.4
Ring a
Ring B
Correlation Coefficient
Flow Coefficient
Exponent
r - .9993
C V.
17.41
n - 0.960
Results:
Air Flow 8 50 ,pascals :
745 CF'M50 +/- 0.5%
6 = 2.33 ACA50 (Air Changes Per Hour)
Effective Leakage Area (LB,) 18.68 Square Inches +/- 4.1%
Equivalent Leakage Area (CANADA) y 46.65 Square Inches *f- 3.6%
Estimated Natural Infiltration (50 Pascal Flaw Divided By 13.6)
s 55 CFM
27.4 Ux/occupANT
0.17 AIR CHANGES pBR HOUR