Loading...
HomeMy WebLinkAbout5021 Rose Ct - CO/LOC - 08/22/1997CERTIFICATE C$A City ofFort Collins OCCUPANCY This certifies that at the time of issuance, the building identified below was inspected and found to be in compliance with applicable ordinances regulating building construction and use in the city of Fort Collins, Colo- rado. This Certificate must be conspicuously displayed in all buildings other than dwellings. Building Address Building Permit Number Building Use(s) 5021 ROSE CT 0971700 SINGLE FAMILY DWELLING Use Zone R Occupancy Classification R Type Construction N LIBERTY HOMES Owner Address 100 W 29TH ST LOVELAND CO 80538 Conditional Provisions Construction Reviewed Under UBC Code 91. Authorized by AUGUST 44, 1997 Date � TAII L t (I - � L-4 I— Ll 6 1 ly ZIP � 1 � CORBETT IDRIUE 68' R.O.w, R = IS' L 23.69' 9m' 30' 21' T = 15.13' C = 2131' N 44' 59' 24' W 25.m' N 00' 15' 46' E 29.85 9' UTILITY (--- EASEMENT I SETBACKS 20' FRONT 15' REAR 5' SIDE 15' SIDE ENGINEERING CONSULTANTS 3EG70 E. PIA7.A. P.E. 1.50 E. 29th Street, Suite 230 LavelenJ. C,Inr=dn 00530 (970) Wi-0:i53 COvERE wl CONCRE PORCH a V x 14' 15' UTILITY" EASEMENT 64.ST 0 le � 0 I 2i CK I � I PROPOSED TWO STORY RESIDENCE - T-79 F.G. 3 CAR g GARAGE m zi j CONC.WALK e DRIvE S ~ 5 00' 15' 46' W R 15' L = 23.43' SS' 29' 39' T = 14 51' C = 21.12' 5 45' mm' 3Fi' W I:3 22 n J � I� 9' UTILITY EASEMENT ROSE COURT 54' 971700 N P OT �1� SCALE: 1' = 20'-m' DATE: 4/9/91 DRAWN BY: CS CNKD. BY: SFP PROJECT NUMBER: 91-3-T-A21 LIBERTY HOMES MOLITOR RESIDENCE 5021 ROSE COURT LOT 29, WILD WOOD FARM, 3RD P-U.D. Fort Collins, Colorado NUV-19-96 TUE 04:44 PM ROBERT SMITH CONST. 970 223 5533 P.01 f#.���,'0NsJ'A44;� ���� 1 FOUNDATION Consulting ENGINEERING I � Engineers, Ltd. r 22r Ate,/ 3 ter, November 1, 1996 Commission No.: 2844-I0-0I-01 Mr. Robert Smith l! Robert Smith Construction ,3DO A-ugust Tail Fort Collins, Colorado 80525 RE: LPI Joist Blocking Dear Mr. Smith: Per the Louisianna-Pacific publication entitled LPI Joists 32 Series Technical Data for Residential and Commercial Floor and Roof Applications, "blocking is recommended, but not required, at interior bearing supports if there is no load -bearing wall above the bearing wall below." It is our opinion that this statement applies to 23 Series Joists as well. In summary, if there is not a bearing wall above the supporting wall, blocking is not structurally required. If you have any questions, please feel free to call. Respectfully, R _V"4u� Mark S. Absbire, Structural Ent Review by: Kevin W. Patt FOUNDATIC MSA/jle TING ENGINEERS, LTD. 5110 Granite Street . Loveland, Colorado 80538 • (970) 663-0138 . Fax (970) 663-1660 5-15-Main -Street, Suite C - Longmont, Colorado 80501 r (30Yr 702-066-1