HomeMy WebLinkAbout4925 Smallwood Ct - Miscellaneous - 07/06/1998Fort Collins residential energy code 7/96
Air sealing disclosure form
Job address: 4925 Smallwood Court
General contractor: ABBCO Builders
Air sealing contractor: ABBCO Builders
A. Prescriptive path
...
I/We certify that the air sealing requirements specified in the current City of Fort Collins Residential Energy Code
have been completed in this building, in accordance with the "Air Sealing Checklist' published by the City of Fort Collins.
Certified by: David Anastasio Phone: 226-4663
Business firm: ARurn Date: 7/6/98 17
Address: 2100 Whitewood Drive Signature: ZQL&Var
B. Performance path
IM/e certify that this building has met the air leakage performance threshold specified in the current
City of Fort Collins Residential Energy Code, in accordance with the "Blower Door Test Procedures;' published
by the City of Fort Collins.
Testing contractor:
Date of test:
CFM50:
Volume:
ACH50:
Certified by:
Business firm:
Address:
Air flow through the blower door at 50 Pascals pressure difference (cfm)
Volume of home (cu. ft.)
Air change rate per hour at 50 Pascals pressure difference
ACH50 = (CFM50 x 60) / Volume
The performance threshold for code compliance is ACH50
not exceeding 5.0 ac/h
Phone:
Date:
Signature:
Instructions
. ..._—
Complete either Part A or Part B.
Part A is to be signed by the air sealing contractor or representative of the general contractor.
Part B is to be signed by the blower door testing contractor or representative of the general contractor.
The "Blower Door Test Report' or equivalent documentation must be attached.
Please type or print, except for the signature.
If components vary, make multiple entries to describe them.
One copy of this form shall be provided to the Building and Zoning Department at final Inspection.
One copy of this form shall be provided to the homebuyer.
t` s s -n lilt]
Fort Collins residential energy code 1/06 4y
_ Mechanical systems disclosure form
I
Job address:
General contractor.
Mechanical contractor.
Space heating system
Location
Fuel
Tvpe
Ma ufacturer
Model #
Input capacity
kBtuh or kW
AFUE or
HSP
Space cooling system
Location
Fuel T pe
Manufacturer
Model #
Input capacity
kBtuh or kW
SEER
I
r
1L
I
Water heating system
Location
Fuel Type
Manufacturer
- Model #
I Input capacity
k8tuh or kW
I Energy I Storage
Factor volume_
I I
1
I
Certification
INVe certify that the above -listed equipment was installed in the building at the above locations in conformance with the
current requirements of the City of Fort Collins Residential Energy Code and Mechanical Code, and that it was installed in
accordance with manufacturer's instructions. VWe certify that any ductwork has been installed in conformance with
the current requirements of the City of Fort Collins Residential Energy Code and Mechanical Code.
Certified by: Robert Miller Phone: 970-223-8873
Business firm: Northern Colorado Air, IncDate:
Address: 1823 E. Harmony Rd. Signature:,, 7 7
Instructions
This clisclosure form -is to -be -signed -by the mechanical -dontractor orrepresentative-of the -general contractor.
Please type or print, except for the signature.
If there are multiple systems serving any function, make multiple entries to describe them.
One copy of this form shall be provided to the Building and Zoning Department at final inspection.
One copy of this form shall be provided to the homebuyer,
Fort Collins residential energy code 7/96
Insulation disclosure form
Job Address: 49Zb SMallmW
General Contractor: 1WBC0 Builde,7:'s
Insulation Contractor: Thermal Concepts Insulation RK IE LI7Y r;.) d 'i c•31'•
P.O. Box 270066
Fort Collins, CO 80522
970-223-7090-
Location Material(s) Thickness R-value
Flat or voulled ceilings with Blown Fiberglas 16" 38
attics above
Ceilings with enclosed rafter Kratt FG batts �1 1211
cavities I I
Frame walls and rim/band I I
FG Batts w/poly 3h"
joists -to exterior
Frame walls and rim/band
joists -to attic,garage
Frame floor -cantilever
Frame floor -over garage or
crawl space
Slab -on -grade (0- 12")
Crawl space walls
Basement walls
Vinyl faced EV blet 3 " 11
FI
r, haf-c t-7" o
Foam sealant
Notes
I/We certify that the above listed insulation in the building at the above locations in conformance with the current requirements of the City of Fort Collins
Residential Energy Code, and Ihat it was installed in accordance with the applicable "Insulation Installation Guidelines' published by the City of Fort Collins.
Certified by: Thermal Concepts Insulation Phone: 970-223-7090
Business firm: Thermal Concepts Insulation Date:
Address: 6617 S. College Ave. Signature: _Zen
This disclosure for is to be signed by the insulation contractor or representative of the general contractor.
Please type or print, except for the signature.
If components vary, make multiple entries to describe them.
One copy of this form shall be provided to the Building and Zoning Department at final inspection,
One copy of this form shnll be provided to the home buyer,
BS