HomeMy WebLinkAbout4514 Red Fox Rd - Disclosures - 12/14/1997Fort Collins residential energy code 7/96 Insulation disclosure form Job address: 5 / /n' c ,j General contractor: NC L + Insulation contractor: (r r+ / � 1 1 V ;_.- ( V, _( f ,-> Insulation Location I Materials Thickness Rated R-value Location lint! ext Notes Flat or vaulted ceilings with attics above % Z f GC' ! Ceilings with enclosed rafter cavities A) Frame walls and rim/band joists -- to exterior p; 3 boa ' `ri Tv X0 Frame walls and rim/band joists -- to attic, garage ' ;' • ! - s ; /%?!� CI' a Frame floor - cantilever �y s Y 1 Frame floor - over garage or crawl space 5 b;= A Slab -on -grade (0-12") Crawl space walls Basement walls Certification' Me certify that the above -listed insulation was installed in the building at the above locations in conformance with the current requirements of the City of Fort Collins Residential Energy Code, and that it was installed in accordance with the applicable "Insulation Installation Guidelines" published by the City of Fort Collins. Certified by: Phone: 22 Business firm: %/cml p F s ,0, i ; 0,. Date: Address: % d F� d Signature: Instructions This disclosure form is to be signed by the insulation contractor or representative of the general contractor. Please type or print, except for the signature. If components vary, make multiple entries to describe them. Nsdzc. I1 S23-Gn4M One copy of this form shall be provided to the Building and Zoning Department at final inspection. One copy of this form shall be provided to the homebuyer. Fort Collins residential energy Job address: General contractor: Air sealing contractor: r,,-' /} z_ D iv . C-i / , ; i ,— A. Prescriptive path IMe certify that the air sealing requirements specified in the current City of Fort Collins Residential Energy Code have been completed in this building, in accordance with the "Air Sealing Checklist' published by the City of Fort Collins. ) Certified by: ItL�G Business firm: Address: B. Performance path Phone: Date: Signature: UWe certify that this building has met the air leakage performance threshold specified in the current City of Fort Collins Residential Energy Code, in accordance with the "Blower Door Test Procedures," published by the City of Fort Collins. Testing contractor: Date of test: CFM5O: Volume: ACH50: Certified by: Business firm: Address: Air flow through the blower door at 50 Pascals pressure difference (cfm) Volume of home (cu. ft.) Air change rate per hour at 50 Pascals pressure difference ACH50 = (CFM50 x 60) / Volume The performance threshold for code compliance is ACH50 not exceeding 5.0 aclh Phone: Date: Signature: Instructions Complete either Part A or Part B. Part A is to be signed by the air sealing contractor or representative of the general contractor. Part B is to be signed by the blower door testing contractor or representative of the general contractor. The "Blower Door Test Report' or equivalent documentation must be attached. Please type or print, except for the signature. If components vary, make multiple entries to describe them. One copy of this form shall be provided to the Building and Zoning Department at final inspection. One copy of this form shall be provided to the homebuyer. as6scmbMS23 — M4/96 Fort Collins residential energy code 7/96 rt, Mechanical systems disclosure form t Job address: General contractor: i&ohanical contractor: :},ace heating system Location Fuel T e Manufacturer Mode( # a Inputcapaclty katuh or kW as_ AFUEor NSPF 'space cooling system Location Fuel T e Manufacturer Model >Y Input capacity kBtuh or kW SEER tfIhAer, heating system Location Fuel T e Manufacturer Model ft Input capacity I k8tuh or kW Energy Factor Storage. volume C,'intification VNe certify that the above -listed equipment was installed in the building at the above locations in conformance with the r;wrent requiremunts of the City of Fort Collins Residential Energy Code and Mechanical Code, and that it was installed in eu:cordance with manufacturer's instrudom. VWe certify that any ductwork has been installed In confarmanca-with- tho -mirrent requirements of the City of FuTtCuilinTResidentiai Energy Code and Mecnanital Code. Certified by: Robert miller Phone: 970-223-8873 Suslnessfirm: Northern Colorado Air, Ind7ate: - Address: 1823 E. lfartnony Rd. Signature: Instructions _ "1"hln disclosure form Is to be signed by the mechanical dontractor or representative of the general contractor, t='leistr type or print: except for the signature. ii ti :.re aro mutiple systems serving any function, make multiple entries to describe them. One.t copy of this form shalt be provided to the Building and Zoning Department at final inspection. One copy of this form shall be provided to the homebuyer.