Cross -Connection Control Required
November 8, 1995
Permit Application # 25166
400 South Meldrum St.- Remodel for Lucile's Restaurant
A backflow prevention assembly is required on the service connection at this address. This must
be an approved Reduced Pressure Backflow Assembly installed horizontally and accessible for
testing. This assembly is designed to discharge water under a backpressure situation when the
second check is fouled. It is also capable of a full discharge if the first check is fouled. Because
of the possibility of this occurring the assembly must be installed in a location where there is
adequate drainage for the size of the service. Call for a test and inspection when assembly is
installed.
All backflow preventer installations must provide adequate clearances on all sides of the backflow
preventer. If ther9151810
estions concerning these backflow preventers please contact this
office.