Loading...
HomeMy WebLinkAbout3908 Ridgeway Ct - Miscellaneous - 02/05/1998Fort Collins residential energy code I Job address: General contractor. Mechanical contractor. Space heating system Space cooling system Water heating system Certification I/We certify that the above4isted equipment was installed in the building at the above locations in conformance with the current requirements of the City of Fort Collins Residential Energy Code and Mechanical Code, and that it was installed in accordance with manufacturer's instructions. VWe certify that any ductwork has been installed in conformance with the current requirements of the City of Fort Collins Residential Energy Code and Mechanical Code. Certified by: Robert Puller Phone: 970_223_8873 Business firm: Northern Colorado Air, IncDate: Address: 1823 E. Harmony Rd. Signature: Instructions This disclosure form is to be signed by the mechanical contractor or representative of the Please type or print, except for the signature. general contractor. If there are multiple systems serving any function, make multiple entries to describe them. One copy of this form shall be provided to the Building and Zoning Department at final inspection. One copy of this form shall be provided to the homebuyer. mclWfu.wEt/557! — 824M Builders Insulation Statement CertainTeed Ci lnsulisafeut, Fiber Glass Insulation InsulSafe III' has been installed with the manufacturer's recommendations to pro- vide a value of R 30 using 17 bags of insulation to cover 879 square feet of area at a minimum thickness of 15.5 inches. ;/? Installer Cont ctor igrry GALE I SULAT'TON Company Name l Date Builder (Sign) ROBART DEVELOPMENT Company Name zin and Blanket ue Insulation Thickness 10", 12", 814", 10" 61/," 54:" 6y^ 31/2" T/,•• 372" with ASTM C 665 glass batts or rolls have been id in accordance with the manu- facturer's recommendation to provide an R-value of 30 in the ceiling, 13 in the exterior walls, 30 in the floor or crawl space perimeter. Instal er Contract-r (Sign) GALE IN&fJLATI Com an Name Date. Builder (Sign) ROBART D=,1,QPNI7MT Company Name Date Thermal Performance — Attic Blowing Application A In accordance with the chart below, you must install the minimum number of bags per 1,000 sq. ft. of net area for each R-Value listed. 3 The maximum net coverage must not exceed that specified for each R-Value. N The installed insulation must be at or above the specified minimum thickness for each R-Value. Failure to install the required minimum weight per sq. ft. of insulation at or above the minimum thickness will result in reduced R-Value. B This product should not be mixed with other blown insulations or the thermal claims will become invalid. rt-values are determined in accordance with ASTM C 687 and 518. Complies with ASTM C 764 as Type I insulation. "R" means resistance to heat flow. The higher the R-Value, the greter the insulating power. To get the marked R-Value, it is essential that the insulation is installed properly. DANGER: RECESSED LIGHT FIXTURES — TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. naming Adjustment To compensate for framing members the number of bags per 1000 sq. ft. of net area should be reduced as follows: Joist Size Bags to Deduct / 1000 sq. ft. Bags to Deduct / 1000 sq. 0. Joists 1e0.c. Joists 24O.C. 2" x 4" 0.5 o.a 2 x 6 0.9 0.6 2" x 8"_ 1.1 O.B 1.4 1.0 CertainTeed Corporation, P.O. Box 860, Valley Forge, PA 19482 Code No.30-24-092 1997 CertainTeed Corporation 5/97 Manufacturer Insulation Fact Sheet Thrs is CertainTeed Corporation Inlilfelll Fiber Mass Blowing Insulation CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 CertainTeedEq Thermal Performance —horizontal Open Blow The following thermal performances are achieved at weights and coverages specified when insulation is installed with pneumatic equipment with a horizontal open blow: -- ivy u cot ana c bid. Conforms to ASTM C 764. Thermal Performance—Sidewall Application When installed with pneumatic equipment in sidewalls, the following thermal performance is achieved at the thicknesses, weights and coverages specified. R-VALUE 1000 SD. FT. BAGS PERT54"37,' UM BAG MINIMUM WEIGHT POUNDS PER SO. Fr MINIMUM To obtain a thermal resistance (R) of: Bags per 1000 sq. tt. f bag cover Weight per sq. ft. of q insulation �nnotllbe THICKNESS Installed insulation of net area: (sq. ft.) lass tha(Ibs )Id .97 less than: (etcbe hes) R-29 38.5 R-22 29.4 .73 5'/z"R-16- 21:3 .534"R-15 19.3.48 3s/e'R-14 18.7.47 3'h" READ THIS BEFORE YOU BUY What you should know about R-Values. The chart shows the R-Value of this insulation. R means resistance to heat flow.. The higher the R-Value, the the insulating greater power. Compare insulation R-Values before you buy. There are other factors to consider. The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type and size of house, your the amount of insulation already in your house, and your fuel use patterns and family size. If you buy too much insulation, you more than what you'll save on fuel. it will cost To get the marked R-Value, it is essential that this insulation be installed properly. Fort Collins residential energy code 7/96 Air sealing disclosure A. Prescriptive path I/We certify that the air sealing requirements specified in the current City of Fort Collins Residential Energy Code have been completed in this building, in accordance with the "Air Sealing Checklist' published by the City of Fort Collins. Certified by:�ti o1. lc /�� Phone: Business firm: J�-+�% `;J. Date: Address: 1/3(�,Signature: B. Performance path I/We certify that this building has met the air leakage performance threshold specified in the current City of Fort Collins Residential Energy Code, in accordance with the "Blower Door Test Procedures," published by the City of Fort Collins. Testing contractor: Date of test: CFM50: Volume: ACH50: Certified by: Business firm: Address: Air flow through the blower door at 50 Pascals pressure difference (cfm) Volume of home (cu. ft.) Air change rate per hour at 50 Pascals pressure difference ACH50 = (CFM50 x 60) / Volume The performance threshold for code compliance is ACH50 not exceeding 5.0 ac/h Phone: Date: Signature: Instructions Complete either Part A or Part B. Part A is to be signed by the air sealing contractor or representative of the general contractor. Part B is to be signed by the blower door testing contractor or representative of the general contractor. The "Blower Door Test Report' or equivalent documentation must be attached. Please type or print, except for the signature. If components vary, make multiple entries to describe them. One copy of this form shall be provided to the Building and Zoning Department at final inspection. One copy of this form shall be provided to the homebuyer. esdx.wb1MM3— 6/24M