HomeMy WebLinkAbout3903 Mesa Verde St - Correspondence - 01/01/2000THE ' WEINTRAUB ORGANIZATION, LTD FOUNDATION COMPLIANCE FORM BUILDING PERMT# ?204 7 8' (By Builder) CONSTRUCTION SITE ADDRESS: Subdivision: Lot & Block: BUILDER'S NAME AND PHONE: L I -am► Richmond American Homes 3600 South Yosemite Street, Suite 200 Denver, CO 80237 (303)773-2727 G I/We hereby state that the foundation system for the above referenced project was constructed in general conformance with the foundation plans and specifications designed for this project and the site where it is constructed. Date: Initials: Inspection: Q -i� TM `� SPREAD FOOTING / ISOLATED PADS QAq-ci �� FOUNDATION WALL REINFORCING STEEL POST TENSION SLAB SLAB ON GRADE / FINISH WALL 0 REG—r f�Gi� 4C �� 5 =` Kenneth R. Brose i, .E. _ -0 3293 ?- SEAL:"L41F` f/�ONAt n1NG�`````` 3� 6000 EAST EVANS AVENUE ■ BUILDING 2, SUITE 400 ■ DENVER, (OLORADO 80222 ■ (303) 504-9330 ■ FAX: (303) SO4 9620 6000 EAST EVANS AVENUE • BUILDING 2, SUITE 400 • DENVER, CO • (303) 504-9933 • FAX (303) 504-9620 • COPYRIGHT 0 THE WEINTRAUB ORGANIZATION, LTD. 1998 FOUNDATION WALL G IZA IO_, TD INSPECTION FORM DATE 11 DATE OF INSPECTION co-M-99 OV RALL RESULTS CLIENT TIME TIME OF INSPECTION 4 I WV 1 L ASS mot! ADD'L TIME ❑N.A. CALLER NAME, r LOCATION: ON SITE HRS PHONE # �lf�� / SUBDIVISIO lk� (}�11rC� , ❑ FAIL (REIN Ma. AEO'D) PROJECT # t 1 �I - `% ADDR �W 1 I LCu�VQ1L►C� ITEM FAILED BILLING IGROODUPy A K� LOT � JB� FILING # P.O.* I �S/ 4 V T ❑ N.A. PLAN # I INSPECTED A5 INSPECTION CHECKLIST ITEM DESCRIPTION PASS FAIL N/A 17EII TO COMMENTS I. FOUNDATION LAYOUT ❑ ❑ ❑ Z• CONNECTION TO PIER / G. ❑ ❑ ❑ 3• ALIGNMENT W/ PIER ' FTG. [ ❑ ❑ ❑ 4. COUNTERFORTS ❑ ❑ ❑ 5• TOP & BOT. REBAR ❑ ❑ Rr 6. HORIZ. & VERT. REBAR [ ❑ ❑ Z' 7. REINF. IN CORNERS & INT. ❑ ❑ ❑ 8. WINDOW REINFORCING ❑ ❑ ❑ 9. STEPS IN_FND._ WALL 10. VOID FORM ❑ ❑ ❑ SIZE IN. PLACEMENT ❑ ❑ d ❑ II. DEBRIS IN FORMWORK ❑ ❑ ❑ 12. REBAR CLEANLINESS Mo" ❑ ❑ ❑ 13. REBAR PLACEMENT ❑ ❑ ❑ 14. OTHER ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ WEATHER PRECAUTIONS: COMMENTS: �1S) PcD() ' ; O`2) j�P .� - Lgws ►moo Cl) VOT. FIELD SKETCH i� wet) wtti0 -Arta- &t cm"- 4 CAL-� 6000 EAST EVANS AVENUE • BUILDING 2, SUITE 400 • DENVER, CO • (303) 504-9933 • FAX (303) 504-9620 NTRATTR GUM. gffmrm DATE — 15 CLIENT 1 F CALLER NAM PHONE PROJECT BILLING GM P.O. # 4, ❑ N.A. I INSPECTION CHECKLIST FOOTING / PAD INSPECTION FORM DATE OF INSPECTION - 4 -99 OV RALL RESULTS TIME OF INSPECTION 00 PASS `�` �� �S ADD'L Tim ❑N.A. LOCATION: ON SITE _HRS SUBDIVISION ❑ FAIL (REINSFEM REQ@D) rrEM ADDRE Q�� ITTEM(S)DF MUD LOT L FILING INSPECTED Q PLAN # I BY: 14 0 � ITEM DESCRIPTION PASS FAIL N/A REFER TO eaeuENM I. CONDITION OF SOIL E ❑ ❑ ❑ UPPER LEVEL U� LOWER LEVEL `` 2. FOOTING WIDTH / DEPTH ❑ ❑ ❑ 3. FOOTING REINFORCING ❑ ❑ ❑ 4. FOOTING PLACEMENT ❑ ❑ ❑ 5. VOID FORM SIZE IN. ❑ ❑ ❑ PLACEMENT ❑ ❑ r!K ❑ 6. VERTICAL DOWELS [ ❑ ❑ 7. OTHER ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 8. DESIGN BEARING PRESSURES MAX. li PSF i MIN. ri PSF WEATHER PRECAUTIONS: COMMENTS: -*6) wt�--A* FIELD SKETCH �...�, �rw.o ercnuc • CUaLlnv c, aUl It 4UU • UtNVtH, L0 • (303) 504-9933 • FAX (303) 504-9620 • COPYRIGHT © THE WEINTRAUB ORGANIZATION, LTD. 1998