HomeMy WebLinkAbout1845 Golden Willow Ct - Disclosures/Other - 07/30/2000SARA'S ENERGY SCORING 2115 WATER BLOSSOM LANE DATE FT. COLLINS CO 80526 07/30/00 (970) 266-1009 CUSTOMER: Kem Homes 1845 Golden Willow C t FORT COLLINS CO 80525 BUILDING CONDITIONS: Interior Temp = 70 F Exterior Temp = 85 F Volume = 34607 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 3 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 57 182 2406 -0.4 Ring A 54 171 2333 0.6 Ring A 51 152 2201 -0.9 Ring A 42 117 1934 1.0 Ring A 32 77 1572 0.9 Ring A 25 50 1270 -1.6 Ring A Correlation Coefficient Flow Coefficient Exponent r = •9989 C = 111.42 n = 0.761 Results: Air Flow @ 50 Pascals : 2187 CFM50 +/- 0.4% = 3.79 ACH50 (Air Changes Per Hour) Effe-c-tive Leakage- Area (LBL) = 9,0.71 Square -Inches +/- 4.4% Equivalent Leakage Area (CANADA) = 188.72 Square Inches +/- 2.8% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 161 CFM = 53.7 CFM/OCCUPANT = 0.28 AIR CHANGES PER HOUR