October 21, 1991
Mr. Jay Witlen
5242 McMurray Drive
Fort Collins, CO 80525
Dear Mr. Witlen:
1525 Blue Spruce Drive
Fort Collins, Colorado 80524
General Health 498-6700
Environmental Health 498-6775
The plans and specifications submitted for the construction of Jay's American
Bistro, 151 South College Avenue, Fort Collins, Colorado, have been reviewed by
this department. The following items were not clearly specified in the plans or
were not in compliance with the Rules and Regulations Governing the Sanitation of
Food Service Establishments in the State of Colorado. These items must be clearly
specified in writing or be modified to be in compliance with the above regulations
prior to approval of the submitted plans. All plans must be approved prior to
commencement of construction.
All food service equipment must be NSF (National Sanitation Foundation)
approved or its equivalent. Custom made equipment and used equipment cannot be
approved until it is visually inspected. The following equipment is not
approved at this time due to lack of information and/or lack of NSF approval.
Submit make and model numbers and specification sheets on the following
equipment item:
K-5
ice machine
K-55
fryer
K-8
mixer
K-59
waffle baker
K-15
reach -in refrigerator
K-60
sandwich unit
K-34
dishmachine
K-94
undercounter refrigerator
K-17
shelving
K-63
hot food well
K-47
Refrigerated drawer base
K-64
undercounter freezer
K-48
pizza oven
K-67
shelving
K-89
glass washer
K-68
refrigerated base
K-49
broiler
K-73
ice cream freezer
K-50
range
K-74
bun warmer
K-51
hot plate
K-83
ice chest
K-53
range
K-95
bottle cooler
K-54
salamander
2. Please specify whether the charbroiler is a lava rock type or radiant type of
charbro i 1 er. BOARD OF COUNTY COMMISSIONERS
Courtlyn W. Hotchkiss M. J. 'Moe' Mekelburg Daryle W. Klassen
District I District 11 District III
Mr. Jay Witlen
October 21, 1991
Page 2
3. Be advised, the refrigeration in the establishment is limited. Sufficient
conveniently located refrigeration facilities must be provided to assure the
maintenance of potentially hazardous food at the required temperatures during
storage and preparation. If additional refrigeration is deemed necessary then
additional refrigeration will be required.
4. All gas equipment (e.g.; broiler, range, fryer, etc.) must be installed in such
a way as to permit easy cleaning around this equipment. It is recommended that
gas lines be long enough to allow the equipment to be pulled far away from the
wall for cleaning or to install pop -off valves on the gas lines to allow the
equipment to be completely disconnected from the gas lines and the wall. Note
how this gas equipment will be installed.
5. Submit size dimensions (length x height x depth) of all -equipment which will be
located below the grease hood to include broiler, range's, salamander and
fryer.
6. Be advised that no appurtenances, such as; syrup lines, carbonators, drop -in
cold plates, drain lines or bottle holders are permitted in potable ice bins or
ice machines or any unit used to store potable ice.
7. Provide a ventilation schedule indicating make up air and exhaust capacities
(CFM rating) of the establishment. Detail the size (length & width), type and
material proposed in the construction of all hoods and similar ventilation
equipment. Submit shop drawings of all hoods to be installed.
The kitchen exhaust hood must be NSF (National Sanitation Foundation)
approved or its equivalent; must be constructed of stainless steel when
located over grease cooking equipment; must overhang all food service
equipment which produce grease vapors, steam, fumes, smoke, etc. not less
than 6 inches beyond the edge of the cooking surface on all open sides.
Please provide locations of all make up air registers along with CFM ratings
found in the establishment.
_Make up air must be filtered;-tempered-(dur--ing winter months) and
mechanically introduced into the establishment at a volume equal to or
greater than what is being exhausted; must be distributed through several
registers to establish necessary air patterns so as not to short circuit
exhaust systems; the kitchen should be under a slight negative pressure so
that make up air can be exhausted through the kitchen exhaust system after
it moves from the dining area into the kitchen.
The kitchen exhaust hood switch must be interlocked with the make up air
system.
All above information must be provided in written form with or part of the shop
drawings of the hood and ventilation system.
All hoods, approved or not, must be visually inspected and approved in writing
by this department prior to installation.
The ventilation system is not approved at this time.
Jay Witlen
October 21, 1991
Page 3
Be advised, the pizza oven may require a ventilation hood, based on size and
BTU rating. Submit information on pizza oven under #1 of this letter.
8. A steam hood is required over the hot temperature dishmachine and must be
considered in the entire ventilation system. Submit make, model number and
type of hood to be installed. Submit the exhaust capacity of this hood.
9. Restrooms must be provided with mechanical ventilation to the outside air.
Indicate if ventilation is provided and the CFM rating of the fan.
10. Since the total seating capacity of the establishment is 175, the following
restroom fixtures will be required: men's room: 2 water closets, 1 sink and 2
urinals. Women's room: 2 water closets and 1 sink.
11. Submit make, model number and recovery rate of a proposed commercial water
heater.
12. Submit the size dimensions of the 3-compartment sink basins including the
width, length and depth.
13. Be advised that the 3-compartment sink tubs must be large enough to submerge
all equipment and utensils used in food preparation and food storage.
14, The mop sink must be provided with hot and cold running water. Provide mop
hangers or hooks around the mop sink to hang and air dry mops.
15. Be advised, an approved stainless steel vegetable sink with a minimum of one 18
inch drain board must be provided if fresh vegetables are prepared as part of a
standard menu item.
16. Be advised, hand sinks must be easily accessible in all rooms where food is
prepared or utensils are washed.
17. Be advised that all hand sinks must be provided with hot and cold running water
under pressure through a mixing valve; single service hand towels from a
dispenser and soap.
3.8. All drain lines from equipment such as; ice machines, ice bins, drink
dispensers, drink overflow drains, liquor gun overflow drains,
refrigeration/freezer units, walk-in compressors and cold tables holding ice
must be directed to a floor drain or floor sink and be properly air gapped.
Note which equipment will require floor drains. Note the locations of all
floor drains.
19. Be advised, floor sinks must not be installed under equipment where they cannot
be cleaned. All floor sinks and floor drains must be installed so that they
are flush with the finished floor.
20. Provide information noting the location and size of the grease trap. The
grease trap must be installed in such a way as to permit easy cleaning around
the equipment.
21. All plumbing and electrical conduit are to be installed within and behind walls
or below floors. Exposed water pipes, sewer lines, or electrical conduit
running along walls or floors are not approved.
Jay Witlen
October 21, 1991
Page 4
22. Be advised, all outer openings including doors and windows must be kept closed,
or permanent screens must be installed on outer openings that will be left open
periodically.
23. Be advised that all exit and restroom doors must be fitted with self -closures.
24. Be advised that a rubber strip or threshold must be installed on all outside
doors to eliminate the gap between the floor and the door so as to prevent
insect infestation.
25. Be advised, 30 foot candles of light are required on all working surfaces and
20 foot-candles of light on all other surfaces and equipment in the kitchen,
storage areas, service counter, waitress station, restrooms, bar, utensil
washing area, janitor's closet, and all food prep areas. At least 10 foot
candles of light must be provided in all areas of the walk-in cooler and
freezer. All lights in the above areas, excluding the restrooms and janitors
closet, must be shielded in an approved manner.
26. Floors, walls, ceilings, counter tops, storage shelves, cabinets and all work
surfaces located within the kitchen, storage rooms, mop room, restrooms,
waitress station, serving area, bar, dishwashing areas, walk-ins, and all food
prep areas must be of an approved material that is smooth, easily cleanable,
nonabsorbent and of a light color. Submit information detailing the finishes
of all floors, walls, ceilings, counter tops, cabinets, storage shelves and all
work surfaces located in the above mentioned areas. Note the colors of all
finishes.
a. Submit information on the color of the paint to be used on F7, F8, F9 and
F10.
b. Submit samples of the floor tile of kitchen, bar, wait area, restrooms,
prep area and janitor area for texture and color approval:
27. All paints used on the walls and ceilings must be: commercial grade; washable,
without removing the paint when cleaned; light in color. An epoxy type paint
or high gloss paint is recommended.
28. All floor/wall and stationary equipment floor junctures in the kitchen, storage
rooms, mop room, restroom, waitress station, serving area, bar, dishwashing
areas, walk-ins, and all food prep areas must be provided with approved concave
coving.
29. All equipment, cabinets, and counters that are not easily moveable must be: a)
spaced so that floors, walls, and exterior surfaces of equipment can be easily
cleaned; or b) be sealed to adjoining walls, equipment, cabinets, or counters.
Hard to clean areas, spaces or gaps are not approved.
30. Be advised that the lowest shelf of all storage shelves located in all kitchen
areas, storage rooms, and the walk-in(s) must be situated at least six inches
up off the floor.
31. Be advised, solid metal shelving in the walk-in cooler and freezer is not
approved, unless NSF approved for use in walk-ins. Wooden shelves, pallets, or
any wooden interior finishes is not permitted in walk-in coolers or freezers.
Metal shelves in the walk-in cooler and freezer must be of an approved metal
wire construction.
11
Jay Witlen
October;21, 1991
Page 5
32. An approved smooth, easily cleanable, non -absorbent, light in color enclosure
must be provided between the top of the walk-in and the ceiling if this area is
24 inches or less. Provide information on this.
33. The outside dumpster storage area must be located on or above a smooth surface
of nonabsorbent material such as concrete or asphalt. Provide information on
this.
34. Provide an approved area away from food operations, food storage and utensil
washing facilities for the storage of toxic materials and surplus cleaning
items. Submit a proposed location.
35. Provide an approved area for the proper storage of employee's personal items;
coats, clothing, etc. It is understood that lockers will be provided.
36. Please be advised that the following items are required in the establishment at
the time of the opening inspection and thereafter:
a) stab food thermometer (00 to 220°F)
b) food grade plastic gloves
c) approved sanitizer
d) test strips for your sanitizer
The plans are not approved at this time. once items #1, 2, 4, 5, 7, 8, 9, 11,
12, 20, 26a, 26b, 32, 33, and 34 have been submitted in writing, the plans will be
reviewed for final approval. be advised, your plans will not be reviewed until all
of these items are resubmitted to this department. After the last item is
resubmitted, this department will review the plans and resubmittals within 10 days.
Be advised that Colorado Revised Statutes (1973) 12-44-206 require plans and
specifications be submitted to the local health department and approved prior to
beginning construction.
Please feel free to contact this department if questions arise, or if I can be
of further service at 498-6775.