Loading...
HomeMy WebLinkAbout2018CV01 - Sutherland V. City Of Fort Collins, Et Al - 022U - Fort Collins Co Land Use Code 3.10.5Division 3.10, Development Standards for the TOD Overlay District Section 3.10.4(D) Figure 16.5 Clear Sight Lines for Pedestrian Safety (Ord. 078, 2007 §1, 6/19/07; Ord. No. 092, 2013 §17, 7/16/13; Ord. No. 086, 2014 §§40, 41, 7/1/14) 3.10.5 Character and Image (A) Articulation. Exterior building walls shall be subdivided and proportioned to human scale, using projections, overhangs and recesses in order to add archi- tectural interest and variety and avoid the effect of a single, massive wall with no relation to human size. (B) Rooflines. Flat -roofed buildings shall feature three-dimensional cornice treat- ment on all walls facing streets or connecting walkways, or a rail at the top of the wall of a usable rooftop deck, unless the top floor is stepped back to form a usable roof terrace area. A single continuous horizontal roofline shall not be used on one-story buildings. Accent roof elements or towers may be used to provide articulation of the building mass. To the maximum extent feasible, a minimum pitch of 6:12 shall be used for gable and hipped roofs. Where hipped roofs are used alone, the minimum pitch shall be 4:12. Article 3, Page 212 Supp. 40 Division 3.10, Development Standards for the TOD Overlay District Section 3.10.5(C) C(C) Materials and Colors. (1) Predominant exterior building materials shall be high quality materials, including, but not limited to, brick, sandstone, other native stone, tinted/textured concrete masonry units, stucco systems or treated tilt -up concrete systems. (2) All building facades shall incorporate stone, stone veneer, brick, brick veneer, stucco, corrugated metal, wood and/or equivalent accent material in a manner that highlights the articulation of the massing or the base and top of the building. An all -brick building does not need to incorporate an accent material, though soldier courses and banding or other brick, stone or metal detailing are encouraged in order to subdivide masses and estab- lish human scale. (3) Predominant or field colors for facades shall be low reflectance, subtle, neutral or earth tone colors. The use of high -intensity colors, black or fluorescent colors shall be prohibited. (4) Building trim and accent areas may feature brighter colors, including primary colors, and black, but neon tubing shall not be an acceptable feature for building trim or accent areas. (5) Exterior buildingmaterials shall not include smooth -faced concrete block, , untreated or unpainted tilt -up concrete panels or prefabricated steel panels. (D) Multiple Store Fronts. Buildings with multiple storefronts shall be unified through the use of architecturally compatible features, such as colors, details, awnings, signage and lighting fixtures. (E) Walls, Fences and Planters. Walls, fences and planters shall be designed to match or be consistent with the quality of materials, style and colors of the development. (F) Building Height. All buildings shall have a minimum height of twenty (20) feet, measured to the dominant roof line of a flat -roofed building, or the mean height between the eave and ridge on a sloped -roof building. In the case of a complex roof with different, co -dominant portions, the measurement shall apply to the highest portion. (1) All buildings shall be limited to the maximum height allowed in the underlying zone district unless: Article 3, Page 213 Supp. 40 Division 3. 10, Development Standards for the TOD Overlay District Section 3.10.5(F) (a) the development is mixed -use and contains at least one -seventh (in) of its total building square footage as either residential or office use, in which case the maximum allowable height shall be the base height plus one (1) story; or (b) the development is mixed -use and contains at least one -seventh (in) of its total building square footage as residential use and at least ten (10) percent of the residential units are either affordable housing units for rent or affordable housing units for sale as defined in Article 5 or structured parking (underground, interior to the site or above ground), in which case the maximum allowable height shall be the base height plus two (2) stories; or (c) the project is mixed -use and contains at least one -seventh (in) of its total building square footage as residential use, and at least ten (10) percent of the residential units are either affordable housing units for rent or affordable housing units for sale as defined in Article 5, and the project contains structured parking (underground, interior to the site or above ground), in which case the maximum height shall be the base height plus three (3) stories. (2) Buildings shall have a base portion consisting of one (1) or two (2) stories. The base portion shall be clearly defined by a prominent, projecting cornice or roof, fenestration, different material and different color from the remainder of the building. If the base portion is two (2) stories, the ground floor shall be further differentiated by fenestration and other detailing. (3) Buildings greater than two (2) stories in height shall also be designed so that upper portions of the building are stepped back from the base. The adequacy of upper floor step -backs shall be determined by the extent to which they advance the following objectives: (a) providing pedestrian scale along sidewalks and outdoor spaces; (b) enhancing compatibility with the scale and massing of nearby buildings; (c) preserving key sunshine patterns in adjacent spaces; and (d) preserving views. Article 3, Page 214 Supp. 40 C Division 3.10, Development Standards for the TOD Overlay District Section 3.10.5(G) (G) Windows. Standard storefront window and door systems may be used as the predominant style of fenestration for nonresidential or mixed -use buildings as long as the building facade visually establishes and defines the building stories and establishes human scale and proportion. Minimum glazing on pedestrian - oriented facades of buildings shall be sixty (60) percent on the ground floor and forty (40) percent on upper floors. Projects functionally unable to comply with this requirement shall mitigate such noncompliance with ample, enhanced architectural features such as a change in massing or materials, enhanced land- scaping, trellises, arcades or shallow display window cases. (H) Display Windows. Ground floor retail, service and restaurant uses shall have large -pane display windows. Such windows shall be framed by the surrounding wall and shall not exceed ninety (90) percent of the total ground level facade area. (Ord. 078, 2007 § 1, 6/19/07; Ord. No. 051, 2012 § 12, 7/17/12; Ord. No. 086, 2014 §42, 7/1/14) Supp. 40 Article 3, Page 215 0 0