HomeMy WebLinkAboutBloom Compaction Testing - Filed CT-CONCRETE TEST - (2)Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 875 Aggregate Base Course: Comet St. and Delozier Rd. - center of northeast curb and gutter radius 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 876 Aggregate Base Course: Comet St. and Delozier Rd. - center of southeast curb and gutter radius 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 877 Aggregate Base Course: Comet St. and Delozier Rd. - center of east crosspan 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 878 Aggregate Base Course: Comet St. and Aria Way - center of northeast curb and gutter radius 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 879 Aggregate Base Course: Comet St. and Aria Way - center of southeast curb and gutter radius 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 880 Aggregate Base Course: Comet St. and Aria Way - center of southwest curb and gutter radius 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 881 Aggregate Base Course: Comet St. and Aria Way - center of northwest curb and gutter radius 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 882 Sidewalk Subgrade: Tract H, between Sykes Dr. and Conquest St. - west private sidewalk, approximately 50 feet south of Conquest St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 875 04/03/24 15 698C Granular 7.5 129.0 5.6 132.9 140.3 4 103 95 A 876 04/03/24 15 698C Granular 7.5 129.0 5.7 124.1 131.2 4 96 95 A 877 04/03/24 15 698C Granular 7.5 129.0 5.5 131.6 138.8 4 102 95 A 878 04/03/24 15 698C Granular 7.5 129.0 5.9 132.7 140.5 4 103 95 A 879 04/03/24 15 698C Granular 7.5 129.0 5.7 122.1 129.0 4 95 95 A 880 04/03/24 15 698C Granular 7.5 129.0 7.0 123.7 132.3 4 96 95 A 881 04/03/24 15 698C Granular 7.5 129.0 6.1 132.1 140.1 4 102 95 A 882 04/04/24 4 698B Granular 12.5 118.0 11.5 112.6 125.6 10 95 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 1 of 9 Compaction Testing Test Method: ASTM D 6938 Report Date: 04/22/2024 Report #: SNG-000022 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 883 Sidewalk Subgrade: Tract H, between Sykes Dr. and Conquest St. - west private sidewalk, approximately 120 feet south of Conquest St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 884 Sidewalk Subgrade: Tract H, between Sykes Dr. and Conquest St. - west private sidewalk, approximately 220 feet south of Conquest St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 885 Sidewalk Subgrade: Tract H, between Sykes Dr. and Conquest St. - center of north connector sidewalk 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 886 Sidewalk Subgrade: Tract H, between Sykes Dr. and Conquest St. - center of south connector sidewalk 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 887 Sidewalk Subgrade: Tract H, between Sykes Dr. and Conquest St. - east private sidewalk adjacent to Lots 17-22 Block 6, approximately 60 feet south of Conquest St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 888 Sidewalk Subgrade: Tract H, between Sykes Dr. and Conquest St. - east private sidewalk adjacent to Lots 17-22 Block 6, approximately 125 feet south of Conquest St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 889 Sidewalk Subgrade: Tract H, between Sykes Dr. and Conquest St. - east private sidewalk adjacent to Lots 17-22 Block 6, approximately 200 feet south of Conquest St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 890 Sidewalk Subgrade: West side of Block 2, between Lots 10 and 11 Block 2, intersection of sidewalks 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 883 04/04/24 4 698B Granular 12.5 118.0 11.7 119.3 133.2 10 101 95 A 884 04/04/24 4 698B Granular 12.5 118.0 11.1 113.5 126.1 10 96 95 A 885 04/04/24 4 698B Granular 12.5 118.0 10.9 112.6 124.9 10 95 95 A 886 04/04/24 4 698B Granular 12.5 118.0 10.5 113.8 125.8 10 96 95 A 887 04/04/24 4 698B Granular 12.5 118.0 10.9 112.5 124.8 10 95 95 A 888 04/04/24 4 698B Granular 12.5 118.0 10.5 118.6 131.0 10 101 95 A 889 04/04/24 4 698B Granular 12.5 118.0 10.5 120.0 132.6 10 102 95 A 890 04/08/24 4 698B Granular 12.5 118.0 10.8 117.6 130.3 12 100 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 2 of 9 Compaction Testing Test Method: ASTM D 6938 Report Date: 04/22/2024 Report #: SNG-000022 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 891 Sidewalk Subgrade: West side of Block 2, between Lots 10 and 11 Block 2, north sidewalk tie-in, adjacent to 502 Fairchild St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 892 Sidewalk Subgrade: West side of Block 2, between Lots 10 and 11 Block 2, south sidewalk tie-in, adjacent to 468 Fairchild St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 893 Curb and Gutter Subgrade: Tract J/Block 6 alleys, west alley, west side of alley, approximately station 12+20 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 894 Curb and Gutter Subgrade: Tract J/Block 6 alleys, west alley, west side of alley, approximately station 10+50 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 895 Curb and Gutter Subgrade: Tract J/Block 6 alleys, west alley, east side of alley, approximately station 10+15 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 896 Curb and Gutter Subgrade: Tract J/Block 6 alleys, west alley, east side of alley, approximately station 10+65 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 897 Curb and Gutter Subgrade: Tract J/Block 6 alleys, center alley, south side of alley, approximately station 11+20 (west end) 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 898 Curb and Gutter Subgrade: Tract J/Block 6 alleys, center alley, south side of alley, approximately station 12+20 (east end) 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 891 04/08/24 4 698B Granular 12.5 118.0 11.2 118.8 132.1 12 101 95 A 892 04/08/24 4 698B Granular 12.5 118.0 13.5 112.7 127.9 12 96 95 A 893 04/08/24 4 698B Granular 12.5 118.0 11.8 113.6 127.0 12 96 95 A 894 04/08/24 4 698B Granular 12.5 118.0 10.8 113.5 125.8 12 96 95 A 895 04/08/24 4 698B Granular 12.5 118.0 10.7 112.2 124.2 12 95 95 A 896 04/08/24 4 698B Granular 12.5 118.0 10.7 111.8 123.8 12 95 95 A 897 04/08/24 4 698B Granular 12.5 118.0 12.9 113.6 128.3 12 96 95 A 898 04/08/24 4 698B Granular 12.5 118.0 11.4 115.7 128.9 12 98 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 3 of 9 Compaction Testing Test Method: ASTM D 6938 Report Date: 04/22/2024 Report #: SNG-000022 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 899 Curb and Gutter Subgrade: Tract J/Block 6 alleys, center alley, north side of alley, approximately station 12+25 (east end) 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 900 Curb and Gutter Subgrade: Tract J/Block 6 alleys, center alley, north side of alley, approximately station 11+25 (west end) 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 901 Curb and Gutter Subgrade: Tract J/Block 6 alleys, east alley, east side of alley, approximately station 10+15 (north end) 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 902 Curb and Gutter Subgrade: Tract J/Block 6 alleys, east alley, east side of alley, approximately station 11+75 (south end) 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 903 Curb and Gutter Subgrade: Tract J/Block 6 alleys, east alley, west side of alley, approximately station 13+00 (north end) 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 904 Curb and Gutter Subgrade: Tract J/Block 6 alleys, east alley, west side of alley, approximately station 13+08 (south end) 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 905 Sidewalk Subgrade: Robud Farms Dr. (cul-de-sac), south side of street, adjacent to Lot 30 Block 1 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 906 Sidewalk Subgrade: Robud Farms Dr. (cul-de-sac), south side of street, adjacent to Lot 28 Block 1 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 899 04/08/24 4 698B Granular 12.5 118.0 10.8 111.9 124.0 12 95 95 A 900 04/08/24 4 698B Granular 12.5 118.0 10.6 112.5 124.4 12 95 95 A 901 04/09/24 4 698B Granular 12.5 118.0 11.7 114.6 128.0 12 97 95 A 902 04/09/24 4 698B Granular 12.5 118.0 11.0 114.9 127.5 12 97 95 A 903 04/09/24 4 698B Granular 12.5 118.0 13.8 112.4 127.9 12 95 95 A 904 04/09/24 4 698B Granular 12.5 118.0 11.3 112.4 125.1 12 95 95 A 905 04/10/24 7 698B Granular 9.5 126.0 8.3 127.5 138.1 12 101 95 A 906 04/10/24 7 698B Granular 9.5 126.0 8.8 128.6 139.9 12 102 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 4 of 9 Compaction Testing Test Method: ASTM D 6938 Report Date: 04/22/2024 Report #: SNG-000022 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 907 Sidewalk Subgrade: Robud Farms Dr. (cul-de-sac), south side of street, adjacent to Lot 24 Block 1 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 908 Sidewalk Subgrade: Robud Farms Dr. (cul-de-sac), south side of street, northeast side of cul-de-sac 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 909 Sidewalk Subgrade: Robud Farms Dr. (cul-de-sac), north side of street, adjacent to Lot 23 Block 1 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 910 Sidewalk Subgrade: Robud Farms Dr. (cul-de-sac), north side of street, adjacent to Lot 21 Block 1 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 911 Sidewalk Subgrade: Private sidewalk (behind Lots 1-12 Block 1) approximately station 12+00 (starting at Lot 1 heading east) 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 912 Sidewalk Subgrade: Private sidewalk (behind Lots 1-12 Block 1) approximately station 14+00 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 913 Sidewalk Subgrade: Private sidewalk (behind Lots 1-12 Block 1) approximately station 16+00 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 914 Sidewalk Subgrade: Private sidewalk (behind Lots 1-12 Block 1) approximately station 18+00 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 907 04/10/24 7 698B Granular 9.5 126.0 7.7 127.8 137.6 12 101 95 A 908 04/10/24 7 698B Granular 9.5 126.0 7.7 127.7 137.5 12 101 95 A 909 04/10/24 7 698B Granular 9.5 126.0 9.3 125.8 137.5 12 100 95 A 910 04/10/24 7 698B Granular 9.5 126.0 7.6 126.8 136.5 12 101 95 A 911 04/10/24 4 698B Granular 12.5 118.0 11.1 114.2 126.9 12 97 95 A 912 04/10/24 4 698B Granular 12.5 118.0 10.6 112.0 123.9 12 95 95 A 913 04/10/24 4 698B Granular 12.5 118.0 12.2 111.9 125.5 12 95 95 A 914 04/10/24 4 698B Granular 12.5 118.0 10.8 114.1 126.4 12 97 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 5 of 9 Compaction Testing Test Method: ASTM D 6938 Report Date: 04/22/2024 Report #: SNG-000022 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 915 Sidewalk Subgrade: Private sidewalk (behind Lots 1-12 Block 1) approximately station 19+50 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 916 Sidewalk Subgrade: Private sidewalk behind Lots 13-20 Block 1, approximately station 10+50 (starting at north end) 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 917 Sidewalk Subgrade: Private sidewalk behind Lots 13-20 Block 1, approximately station 11+50 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 918 Sidewalk Subgrade: Private sidewalk behind Lots 13-20 Block 1, approximately station 12+75 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 919 Aggregate Base Course: Aria Way, northbound lane, intersection of Comet St.0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 920 Aggregate Base Course: Aria Way, northbound lane, approximately 100 feet north of Comet St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 921 Aggregate Base Course: Aria Way, northbound lane, approximately 130 feet south of Comet St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 922 Aggregate Base Course: Aria Way, northbound lane, approximately 275 feet south of Comet St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 915 04/10/24 4 698B Granular 12.5 118.0 12.3 111.7 125.4 12 95 95 A 916 04/11/24 7 698B Granular 9.5 126.0 9.2 128.0 139.8 12 102 95 A 917 04/11/24 7 698B Granular 9.5 126.0 11.4 119.8 133.5 12 95 95 A 918 04/11/24 7 698B Granular 9.5 126.0 11.4 120.2 133.9 12 95 95 A 919 04/12/24 15 698C Granular 7.5 129.0 5.9 128.9 136.5 4 100 95 A 920 04/12/24 15 698C Granular 7.5 129.0 5.9 131.7 139.5 4 102 95 A 921 04/12/24 15 698C Granular 7.5 129.0 5.9 127.9 135.4 4 99 95 A 922 04/12/24 15 698C Granular 7.5 129.0 5.9 126.3 133.8 4 98 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 6 of 9 Compaction Testing Test Method: ASTM D 6938 Report Date: 04/22/2024 Report #: SNG-000022 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 923 Aggregate Base Course: Aria Way, northbound lane, approximately 425 feet south of Comet St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 924 Aggregate Base Course: Aria Way, southbound lane, approximately 450 feet south of Comet St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 925 Aggregate Base Course: Aria Way, southbound lane, approximately 300 feet south of Comet St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 926 Aggregate Base Course: Aria Way, southbound lane, approximately 150 feet south of Comet St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 927 Aggregate Base Course: Aria Way, southbound lane, approximately 40 feet north of Comet St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 928 Aggregate Base Course: Aria Way, southbound lane, approximately 175 feet north of Comet St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 929 Aggregate Base Course: Comet St. - westbound lane, approximately 75 feet west of Aria Way 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 930 Aggregate Base Course: Comet St. - westbound lane, approximately 225 feet west of Aria Way 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 923 04/12/24 15 698C Granular 7.5 129.0 5.6 125.4 132.4 4 97 95 A 924 04/12/24 15 698C Granular 7.5 129.0 6.1 131.9 140.0 4 102 95 A 925 04/12/24 15 698C Granular 7.5 129.0 5.6 127.6 134.8 4 99 95 A 926 04/12/24 15 698C Granular 7.5 129.0 6.6 131.8 140.5 4 102 95 A 927 04/12/24 15 698C Granular 7.5 129.0 5.8 124.8 132.0 4 97 95 A 928 04/12/24 15 698C Granular 7.5 129.0 5.7 126.6 133.8 4 98 95 A 929 04/12/24 15 698C Granular 7.5 129.0 5.9 131.7 139.5 4 102 95 A 930 04/12/24 15 698C Granular 7.5 129.0 5.9 128.0 135.6 4 99 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 7 of 9 Compaction Testing Test Method: ASTM D 6938 Report Date: 04/22/2024 Report #: SNG-000022 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 931 Aggregate Base Course: Comet St. - westbound lane, approximately 375 feet west of Aria Way 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 932 Aggregate Base Course: Comet St. - westbound lane, approximately 600 feet west of Aria Way 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 933 Aggregate Base Course: Comet St. - eastbound lane, approximately 100 feet west of Aria Way 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 934 Aggregate Base Course: Comet St. - eastbound lane, approximately 250 feet west of Aria Way 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 935 Aggregate Base Course: Comet St. - eastbound lane, approximately 400 feet west of Aria Way 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 936 Aggregate Base Course: Comet St. - eastbound lane, approximately 600 feet west of Aria Way 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 937 Aggregate Base Course: Roselyn St. - southbound lane, intersection of eastbound Comet St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 938 Aggregate Base Course: Roselyn St. - southbound lane, approximately 150 feet south of Comet St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 931 04/12/24 15 698C Granular 7.5 129.0 5.6 131.3 138.7 4 102 95 A 932 04/12/24 15 698C Granular 7.5 129.0 5.9 131.3 139.0 4 102 95 A 933 04/12/24 15 698C Granular 7.5 129.0 6.0 130.3 138.1 4 101 95 A 934 04/12/24 15 698C Granular 7.5 129.0 5.5 126.3 133.3 4 98 95 A 935 04/12/24 15 698C Granular 7.5 129.0 6.0 130.0 137.8 4 101 95 A 936 04/12/24 15 698C Granular 7.5 129.0 6.1 132.0 140.0 4 102 95 A 937 04/12/24 15 698C Granular 7.5 129.0 6.0 131.7 139.6 4 102 95 A 938 04/12/24 15 698C Granular 7.5 129.0 5.8 130.0 137.6 4 101 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 8 of 9 Compaction Testing Test Method: ASTM D 6938 Report Date: 04/22/2024 Report #: SNG-000022 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 939 Aggregate Base Course: Roselyn St. - southbound lane, approximately 350 feet south of Comet St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 940 Aggregate Base Course: Roselyn St. - northbound lane, approximately 450 feet south of Comet St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 941 Aggregate Base Course: Roselyn St. - northbound lane, approximately 275 feet south of Comet St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 942 Aggregate Base Course: Roselyn St. - northbound lane, approximately 75 feet south of Comet St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 939 04/12/24 15 698C Granular 7.5 129.0 5.9 126.3 133.7 4 98 95 A 940 04/12/24 15 698C Granular 7.5 129.0 5.5 128.3 135.3 4 99 95 A 941 04/12/24 15 698C Granular 7.5 129.0 6.2 126.5 134.4 4 98 95 A 942 04/12/24 15 698C Granular 7.5 129.0 5.6 124.8 131.8 4 97 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 9 of 9 Compaction Testing Test Method: ASTM D 6938 Report Date: 04/22/2024 Report #: SNG-000022 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins