Loading...
HomeMy WebLinkAboutCOMPRESSIVE STRENGTH OF CONCRETE - Filed CSS-COMPRESSIVE STRENGTH SUMMARY - (98)Specimen Number Test Age Days Test Date Field / Lab Cure Days Average Cylinder Diameter (in) Cylinder Area (in²) Max Load (lbs) Strength (psi) Fracture Type Break Remark Capping Method 270-1 7 05/23/24 1 / 6 4.00 12.57 55,260 4,400 3 N 270-2 28 06/13/24 1 / 27 4.00 12.57 73,510 5,850 3 C4 N 270-3 28 06/13/24 1 / 27 4.00 12.57 73,520 5,850 3 C4 N 270-4 28 06/13/24 1 / 27 4.00 12.57 71,990 5,730 3 C4 N 270-5 56 07/11/24 1 / 55 Test Age Average Strengths (psi): 7 Day - 4400, 28 Day - 5810 C4: Strength is greater than or equal to f'c. Tested By: Craig Ellis (1,2,3,4) Checked In : 05/17/2024 (1,2,3,4,5) Capping Methods N: Unbonded Caps (ASTM C1231) Set #:270 Specimen Size:4" X 8" Specimens In Set:5 Truck / Ticket #:1703 / 21096815 Contractor:Front Range Concrete Technician:Flaherty, Alexander Cast By:Flaherty, Alexander Date Cast:05/16/24 Sampled From:Chute Placement Method:Bucket Sample Details Batched:10:43 MDT Sampled:11:45 MDT Cast:12:00 MDT Truck Empty: Placement Time: Placement Location:Wall Location Details:Irrigation structure south east corner of E Vine and Wagon Trail Sample Location / Notes:Mix 45262 Batch Log Strength:4500 (psi) Specifications Supplier:SRM Concrete On-Site Admixtures: None Location Field Measurements Plastic Unit Weight:142.8 (lb/ft³) Air Content:5.0 Load Volume:11.00 (yd³) Weather:Slump (in):4 Air Temperature (F):67 Concrete Temp (F):73 Lab Test Results Testing Lab: Fort Collins, 400 North Link Lane, Fort Collins, CO, 80525 General Remarks 270-1: Reviewed by CE Test results relate only to the sample tested. Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064). This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc. Page 1 of 1 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-365 Compressive Strength of Concrete Test Method: ASTM C 39 Sample: 129681 Report #: CC-000935 Fort Collins 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Report Date: 06/13/2024