Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAbout714 SOUTH COLLEGE AVENUE - Filed T-TELECOMMUNICATION PLANS - 2019-01-17Page is too large to OCR.
I
CHARLES CUBE SMALL CELL CABINET
MODEL: RL11411AN1
CABINET WEIGHT:
N 82LBS. (AS SHIPPED)
E I I
(,4)
N.T.S.
PROPOSED AWS RRH
MOUNTED ON UNISTRUT TO
PARKING GARAGE WALL
(SEE DETAIL 1/A-2)
P1000 GALVANIZED UNISTRUT
MOUNTED TO GARAGE WALL
(DETERMINE SPACING IN FIELD)
PROPOSED PCS RRH
MOUNTED ON UNISTRUT TO
PARKING GARAGE WALL
(SEE DETAIL 2/A-2)
DUPLEXERS
7/8" COAX
„� ww, o%
4GARAGE EQU
C-5 SC SALE: 3/4" = 1'-0"
GRAPHIC SCALE
1 2
( IN FEET)
3/4 inch = 1 ft.
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
TAM \/IC\A/
U.L. SYSTEM NO. CAJ1150
METAL PIPE/CONDUIT THROUGH CONCRETE FLOOR O
F RATING = 3-HR
T RATING = 0-HR
SECTION A -A
(2) PROPOSED 1/2" COAX
JUMPERS ROUTED THRU
EXISTING SOFFIT AND THRU
ROOF TO PROPOSED
ANTENNA
(2) PROPOSED 7/8" COAX
ROUTED THRU EXISTING
SOFFIT AND THRU ROOF
TO PROPOSED ANTENNA
NOTES:
1. EXISTING CORES TO BE INSPECTED FOR EVIDENCE OF CUT RE -BAR, IF
EVIDENCE OF CUT RE -BAR IS FOUND, CONTACT AERO SOLUTIONS LLC
IMMEDIATELY TO INVESTIGATE FURTHER.
2. CONTRACTOR TO DRILL PILOT HOLES TO CHECK RE -BAR LOCATION
BEFORE INSTALLATION OF ANY CONDUIT
CC_o2 d ¢
PROPOSED NEMA 3R RATED EQUIPMENT
CABINET MOUNTED TO GARAGE WALL
(PAINT GRAY TO MATCH EXISTING WALL)
(SEE DETAIL 1/C-5)
PROPOSED 100A
ELECTRICAL SUB
PANEL
EXISTING WALL
PROPOSED 7/8" COAX
WITH SNAP STACK (TYP)
PROPOSED P1000 UNISTRUT
(SPACED X-0"" O.0 MAX)
PROPOSED 1/2" Ox4" LAG SCREW
IN STUD OR 1/2" EXPANDING
ANCHOR INTO CMU WALL
(CONTRACTOR TO VERIFY)
5COAX ATTACHMENT � R. R
C-5 N.T.S.
r
PROPOSED VERIZON ANTENNA
PROPOSED SHROUDED
CUSTOM SLED MOUNT
PROPOSED RUBBER MAT SITEPRO P/N
MAT18 OR APPROVED EQUIVALENT (TYP)
(MATCH ROOF COLOR)
(TRIM TO MATCH SLED DIMENSIONS)
-3COAX ROUTING DETAIL
C-5 SCALE: 1/2" = 1'-0"
GRAPHIC SCALE
2 4
(IN FEET)
1/2 inch = 1 ft.
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
PROPOSED 6" WALL MOUNT
COVERED COAX KIT,
SITE PR01 PART NO. WMC4,
OR APPROVED EQUAL
(PAINT TO MATCH BUILDING)
EXISTING EXTI
PROPOSED 7/8" STACKABLE
JAP-IN HANGER
4" 0 HILTI ANCHOR W/ MIN. 1"
EMBEDMENT INTO EXISTING
WALL
sATTACHMENT I
C-5 N.T.S.
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303)873-2652
tiJUittiv�,.ay YOut vV.rc;c . ;;,rc•
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
DROJECT#:097-17-0099
REVISION SCHEDULE
3
06-22-18
LCW
REVISED CDs
2
05-17-18
LCW
REVISED CDs
1
03-29-18
LCW
100% CDs
0
01-24-18
RPH
PRELIM CDs
REV
DATE
BY
DESCRIPTION
DRAWING TITLE:
CONSTRUCTION
DETAILS
Cmm5
_T NUMBER:
10 OF 22
BITE INFORMATION:
SITE NAME:
FTC MUGS COFFEE SC
SITE ADDRESS:
714 S COLLEGE AVE
FT COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
A
PE-33495
�f f� 4y'�•�,r
,t.
E G
,NAL
I
MIKKO P. AHOLA, P.E.
COLORADO PROFESSIONAL EUGIDiEER
LICENSE #33495 (EXP. 10/31/'2019)
M2w
Page is too large to OCR.
Page is too large to OCR.
Page is too large to OCR.
Page is too large to OCR.
Page is too large to OCR.
v
ANTE , " CABLE SCHEDULE
SECTOR I AZIMUTH
MOUNTING
HEIGHT
ANTENNA MODEL
TECHNOLOGY
I) A I N/A 44'-9" OMNI PCS/AWS
ANTENNA
ANTENNA SPECIFICATIONS
39"(H) X 12"(D)
33.5 LBS
MECHANICAL I ELECTRICAL CABLE SIZE CABLE
DOWNTILT DOWNTILT LENGTH
00 00 (2) 7/8" COAX 80 FT.
NOTES:
1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING.
2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE.
3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO INSTALLING ANY
ANTENNAS.
EXISTING SOFFIT
EXISTING LADDER
PROPOSED ROOFTOP
PENETRATION
PROPOSED QUASI-OMNI ANTENNA
MOUNTED ON CUSTOM
NON -PENETRATING PEAK MOUNT
(SEE DETAIL 2/A-1)
PROPOSED FAUX CHIMNEY PAINTED
& TEXTURED TO MATCH EXISTING
BUILDING'S BRICK FACADE
(SEE SHEET C-5 FOR MORE DETAIL)
PROPOSED RUBBER MAT SITEPRO P/N
MAT18 OR APPROVED EQUIVALENT (TYP)
(MATCH ROOF COLOR)
(TRIM TO MATCH SLED DIMENSIONS)
1-'
ACCORDING TO THE STRUCTURAL
ANALYSIS BY AERO SOLUTIONS,
LLC DATED 11/17/17, THE
PROPOSED MOUNT REQUIRES A
MINIMUM OF 280 LBS OF BALLAST
PER SIDE, 560 LBS TOTAL""� k'
PROPOSED CUSTOM
NON -PENETRATING PEAK PROPOSED PCS RRH MOUNTED ON
ROOF MOUNT UNISTRUT TO PARKING GARAGE WALL
(MATCH ROOF COLOR) (SEE DETAIL 2/A-2)
(SEE SHEETS ST-1 THROUGH
ST-5 FOR MORE DETAIL) PROPOSED AWS RRH MOUNTED ON
UNISTRUT TO PARKING GARAGE WALL
(SEE DETAIL 1/A-2)
PROPOSED EQUIPMENT CABINET
MOUNTED TO PARKING GARAGE WALL
(PAINT TO MATCH EXISTING WALL)
(SEE DETAIL 1/C-5)
PROPOSED 17N - ,!
. sr4t, A -
GRAPHIC SCALE
4 0 2 4 0
( IN FEET)
1/4 inch = 1 k
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
PROPOSED COAX ROUTED UP
ALONG NEW 6" SHROUDED CABLE
TRAY & THRU EXISTING SOFFIT TO
NEW ANTENNA
PROPOSED 6" SHROUDED CABLE TRAY
(SHROUD TO MATCH EXISTING DOWN SPOUTS)
PROPOSED COAX ROUTED
ALONG EXTERIOR OF BUILDING
TO SHROUDED CABLE TRAY
(PAINT TO MATCH BUILDING)
I �63 L
S Sb0 \
a
PROPOSED OMNI
ANTENNA
PROPOSED ANTENNA
MOUNT
(COMMSCOPE MC-MNT-TS1)
PROPOSED CUSTOM
NON -PENETRATING MOUNT
(MATCH ROOF COLOR)
(SEE SHEETS ST-1 THROUGH
ST-5 FOR MORE DETAIL)
LM
ANTENNA MOUNTING DETAIL
A-1 SCALE: 3/8" = 1'-0"
GRAPHIC SCALE
0.5 0 0.5 1 2 3 4
( IN FEET)
3/8 inch = 1 ft.
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
7/8" COAX (TYP)
1/2" COAX (TYP)
DC CABLES & FIBER
JUMPERS (TYP)
CONFIGURATION
QUASI-OMNI
ANTENNA
5
DIPLEXER
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVE s'_!
BOULDER, COLORAD' iJ31
PH: (720) 304-6882
FAX: (720) 304-6883
AERO PROJECT #: 097-17-^
REVISION ,!J_E:
3 1 06-22-18 ILCWI REVISED CDs
2
1 05-17-18
LCW
REVISED CDs
1
03-29-18
LCW
100% CDs
0
01-24-18
RPH
PRELIM CDs
REV
DATE
BY
DESCRIPTION
DRAWING TITLE:
ANTENNA SCHEDULE,
MOUNTING PLAN &
PLUMBING DIAGRAM
Amm 1
16 OF 22
SITE INFORMATION:
SITE NAME:
FTC MUGS COFFEE SC
SITE ADDRESS:
714 S COLLEGE AVE
FT COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
PE-33493
3PLUMBING DIAGRAM
MIKKO P. AHOLA, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #33495 (EXP. 10/31/2019)
Page is too large to OCR.
Page is too large to OCR.
Page is too large to OCR.
1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN
ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 07/18/17.
2. THE PROPOSED FACILITY WILL CAUSE "DE MINIMIS" INCREASE IN
STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE
PROPOSED.
3. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY
4. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. (THERE
IS NO HANDICAP ACCESS REQUIRED).
5. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER
OR SANITARY SERVICE.
6. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF
1988 (NAVD 1988).
7. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF
ANY TYPE.
8. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR
STORAGE OR ANY SOLID WASTE RECEPTACLES.ANY WORK ASSOCIATED
WITH THE ROOFING MEMBRANE SUCH AS ANCHORAGE, CONDUIT
PLACEMENT, ADDED ISOLATION PADS, ETC. MUST BE INSTALLED BY A
ROOFER THAT IS APPROVED BY THE MANUFACTURER OF THE
INSTALLED ROOF MEMBRANE.
9. FINAL WORK SHALL BE PROPERLY SEALED AND WATERTIGHT. ALL
DEBRIS SHALL BE REMOVED FROM THE ROOF AND PHOTOGRAPHIC
RECORD OF FINAL CONDITION OF THE ROOF SHALL BE SENT TO THE
OWNER'S REPRESENTATIVE. NOTIFICATION OF COMPLETION OF WORK
SHALL BE DONE VIA THE AGREED UPON CHANNELS OF COMMUNICATION.
10. RF SIGNAGE TO BE INSTALLED AT ANY/ALL ROOF ACCESS POINTS ON
THE BUILDING.
rl
GROUNDING NOTES.
1. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRIC CODE.
2. ALL GROUNDING DEVICES SHALL BE U.L. APPROVED OR LISTED FOR THEIR
INTENDED USE.
3. ALL WIRES SHALL BE AWG THHN/THWN COPPER UNLESS NOTED OTHERWISE.
4. GROUND WIRES SHALL BE #2 AWG BARE SOLID COPPER UNLESS NOTED
OTHERWISE.
5. GROUNDING CONNECTIONS SHALL BE EXOTHERMIC ("CADWELDS") TO GROUND
RODS, GROUND RING WIRE, AND FENCE POSTS UNLESS NOTED OTHERWISE. CLEAN
SURFACES TO SHINY METAL. WHERE GROUND WIRES ARE CADWELDED TO
GALVANIZED SURFACES, SPRAY CADWELD WITH GALVANIZED PAINT.
6. GROUNDING CONNECTIONS TO GROUND BARS ARE TO BE TWO -HOLE BRASS
MECHANICAL CONNECTORS WITH STAINLESS STEEL HARDWARE (INCLUDING
SCREW SET.) CLEAN GROUND BAR TO SHINY METAL AFTER MECHANICAL
CONNECTION, TREAT WITH PROTECTIVE ANTIOXIDANT COATING.
7. GROUND CABLE SHIELDS AT BOTH ENDS WITH MANUFACTURER'S GROUNDING KITS.
8. ROUTE GROUNDING CONDUCTORS ALONG THE SHORTEST AND STRAIGHTEST PATH
POSSIBLE. BEND GROUNDING LEADS WITH A MINIMUM 8" RADIUS.
9. PRIOR TO INSTALLING LUGS ON GROUND WIRES, APPLY THOMAS & BETTS
KOPR-SHIELD (TM OF JET LUBE, INC.) PRIOR TO BOLTING GROUND WIRE LUGS TO
GROUND BARS, APPLY KOPR-SHIELD OR EQUAL.
10. PREPARE ALL BONDING SURFACES FOR GROUNDING CONNECTIONS BY REMOVING
ALL PAINT AND CORROSION DOWN TO SHINY METAL. FOLLOWING CONNECTION,
APPLY APPROPRIATE ANTI -OXIDIZATION PAINT.
LUECTRICAL
1. CONTRACTOR SHALL INSPECT THE EXISTING CONDITIONS PRIOR TO SUBMITTING BID. ANY
QUESTIONS ARISING DURING THE BID PERIOD IN REGARDS TO THE CONTRACTORS
FUNCTIONS, THE SCOPE OF WORK, OR ANY OTHER ISSUE RELATED TO THIS PROJECT SHALL
BE BROUGHT UP DURING THE BID PERIOD WITH THE PROJECT MANAGER FOR CLARIFICATION,
NOT AFTER THE CONTRACT HAS BEEN AWARDED.
2. LOCATION OF EQUIPMENT, CONDUIT AND DEVICES SHOWN ON THE DRAWINGS ARE
APPROXIMATE AND SHALL BE COORDINATED WITH FIELD CONDITIONS PRIOR TO ROUGH -IN.
3. THE CONDUIT RUNS AS SHOWN ON THE PLANS ARE APPROXIMATE. EXACT LOCATION AND
ROUTING SHALL BE PER EXISTING FIELD CONDITIONS.
4, PROVIDE PULL BOXES AND JUNCTION BOXES WHERE SHOWN OR REQUIRED BY NEC.
5. ALL CONDUITS SHALL BE MET WITH BENDS MADE IN ACCORDANCE WITH NEC CHAPTER 9,
TABLE #2. NO RIGHT ANGLE DEVICE OTHER THAN STANDARD CONDUIT ELBOWS WITH 12"
MINIMUM INSIDE SWEEPS FOR ALL CONDUITS 2" OR LARGER.
6. ALL CONDUIT TERMINATIONS SHALL BE PROVIDED WITH PLASTIC THROAT INSULATING
GROUNDING BUSHINGS.
7. ALL WIRE SHALL BE TYPE THHN/THWN, SOLID, ANNEALED COPPER UP TO SIZE #10 AWG (#8
AND LARGER SHALL BE CONCENTRIC STRANDED) 75° C (167- F), 98% CONDUCTIVITY, MINIMUM
#12.
8. ALL WIRES SHALL BE TAGGED AT ALL PULL BOXES, J-BOXES, EQUIPMENT BOXES AND
CABINETS WITH APPROVED PLASTIC TAGS, ACTION CRAFT, BRADY, OR APPROVED EQUAL.
9. ALL NEW MATERIAL SHALL HAVE A U.L. LABEL.
10. CONDUIT ROUGH -IN SHALL BE COORDINATED WITH THE MECHANICAL EQUIPMENT TO AVOID
LOCATION TO CONFLICTS. VERIFY WITH MECHANICAL CONTRACTOR AND COMPLY AS
REQUIRED.
11. ALL PANEL DIRECTORIES SHALL BE TYPEWRITTEN NOT HAND WRITTEN.
12. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS PER THE SPECIFICATIONS
AND NEC. THE EQUIPMENT GROUNDING CONDUCTORS SHALL BE BONDED AT ALL JUNCTION
BOXES, PULL BOXES, AND ALL DISCONNECT SWITCHES, STARTERS, AND EQUIPMENT
CABINETS.
13. THE CONTRACTOR SHALL PREPARE AS -BUILT DRAWINGS, DOCUMENT ANY AND ALL WIRING
AND EQUIPMENT CONDITIONS AND CHANGES WHILE COMPLETING THIS CONTRACT. SUBMIT AT
SUBSTANTIAL COMPLETION.
14. ALL DISCONNECT SWITCHES AND OTHER CONTROLLING DEVICES SHALL BE PROVIDED WITH
ENGRAVED LAMICOID NAMEPLATES INDICATING EQUIPMENT CONTROLLED, BRANCH CIRCUITS
INSTALLED ON, AND PANEL FIELD LOCATIONS FED FROM (NO EXCEPTIONS.)
15. ALL ELECTRICAL DEVICES AND INSTALLATIONS OF THE DEVICES SHALL COMPLY WITH
AMERICANS WITH DISABILITIES ACT (ADA) AS ADOPTED BY THE APPLICABLE STATE.
16. PROVIDE CORE DRILLING AS NECESSARY FOR PENETRATIONS OR RISERS THROUGH BUILDING.
DO NOT PENETRATE STRUCTURAL MEMBERS WITHOUT CONSTRUCTION MANAGER'S
APPROVAL. SLEEVES AND/OR PENETRATIONS IN FIRE RATED CONSTRUCTION SHALL BE
PACKED WITH FIRE RATED MATERIAL WHICH SHALL MAINTAIN THE FIRE RATING OF THE WALL
OR STRUCTURE, FILL FOR FLOOR PENETRATIONS SHALL PREVENT PASSAGE OF WATER,
SMOKE, FIRE AND FUMES. ALL MATERIAL SHALL BE UL APPROVED FOR THIS PURPOSE,
17. ELECTRICAL CHARACTERISTICS OF ALL EQUIPMENT (NEW AND EXISTING) SHALL BE FIELD
VERIFIED WITH THE OWNER'S REPRESENTATIVE AND EQUIPMENT SUPPLIER PRIOR TO
ROUGH -IN OF CONDUIT AND WIRE. ALL EQUIPMENT SHALL BE PROPERLY CONNECTED
ACCORDING TO THE NAMEPLATE DATA FURNISHED ON THE EQUIPMENT (THE DESIGN OF
THESE PLANS ARE BASED UPON BEST AVAILABLE INFORMATION AT THE TIME OF DESIGN AND
SOME EQUIPMENT CHARACTERISTICS MAY VARY FROM DESIGN AS SHOWN ON THESE
DRAWINGS). LOCATION OF ALL OUTLET, BOXES, ETC., AND THE TYPE OF CONNECTION (PLUG
OR DIRECT) SHALL BE CONFIRMED WITH THE OWNER'S REPRESENTATIVE PRIOR TO ROUGH -IN.
verizon
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
V- __ COL
OR STANDARDS
GRAY -EXISTING EASEMENT =-ANGE-FIBER
PURPLE #1-
LEASE AREA TAN -ANTENNAS
BLUE GRAY#1- I
ACCESS/UTILITY RED -PENETRATIONS t3prmiaurg Your w,rere
BLUE #1-HYBRID UMBER -NEW WORK ) 5555 CENTRAL AVENUE #100
CABLES/COAX UTILITY EASEMENT BOULDER, COLORADO80301
PH: (720) 304-6882
FAX: (720) 304-6883
BLUE #2-RRHS I GRAY -WALL HATCH �u 1
GREEN -DC POD• GREY_E ? ING AERO PROJECT#: 097-17-0099
REVISION SCHEDULE
WATER LINE D s" . s" s" 80
SANITARY SEWER ss LECTRI{ - UE -Ur -
GAS LINE-GAi-o� _ E
FIBER LINE ___ UT OT-
OH ELECTRIC °E - PROPERT; 1NE
UG TELCO UT FENCE IF N 0
3 06-22-18 LCW REVISED CDs
FENCE CLF - X - UG UTILITIES ">G --
RIGHT OF WAY 'H I_I' 'TIFS oHw -- - 2 05-17-18 LCW REVISED CDs
WATER METER wv' = 1 03-29-18 LCW 100%CDs
WATER Vf M CA' H BAST(,; 0 01-24-18 RPH PRELIM CDs
IRRIGATION VALVE I® STORM MANHOLE O _ REV DATE BY
SAN SEWER MH CO, DRAWINGTI+
TELCO MAN HOLE �_%'AFFIC SI�-INAL _
LIGHT POLE ELECTRIC VAULT _ u _ GENERAL ._.__ _. NOTES
__.._.._...,.__..__
ELEC PULL BOX ❑E ELECTRIC CABINET Ci ABl
ELECTRIC EQUIP eQ ELECTRICAL XFMR
SKYLIGHT ❑ HVAC UNIT 4
VP
SECURITY CAMERA ® VENT PIPE O rGNowl
BOLLARD COMM DISH 1-
SITE INFORMATION:
SITE NAME:
FTC MUGS COFFEE SC
SITE ADDRESS:
714 S COLLEGE AVE
FT COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
(- PE-33493
L
MIKKO P. AHOLA, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #33495 (EXP. 10/31/2019)
Page is too large to OCR.
Page is too large to OCR.
Page is too large to OCR.
PHOTOSII ULAT ' VIEW (BEFORE, LOOKING EAST)
PH-7 N.T.S.
2
PHOTOS PAOU'I.A T!ON VIEW (AFTER., LOOKING EAST)
PH•7 N.T.S.
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
Optrmuing YOUC YYrtbHt3a5 dnlrastr«ctu>e
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
AERO PROJF nogg
REVISION SCHEDULE
3 1 06-22-18 ILCWI REVISED CDs
2
05-17-18
LCW
REVISED CDs
1
03-29-18
LCW
100% CDs
i
0
01-24-18
RPHI
IM r"s,
DESCRIPTION
REV
DATE
BY
DRAWING TITLE:
PHOTOSIMULATIO
VIEWS
PH-1
3 OF 22
SITE INFORMATION:
SITE NAME:
FTC MUGS COFFEE SC
SITE ADDRESS:
714 S COLLEGE AVE
FT COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
PE-/33495/
MIKKO P. AHOLA, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #33495 (EXP. 10/31/2019)
B
PROPOSED COAX ROUTED UP
ALONG NEW SHROUDED CABLE
TRAY & THRU EXISTING SOFFIT TO
NEW ANTENNA
PROPOSED FAUX CHIMNEY PAINTED
& TEXTURED TO MATCH EXISTING
BUILDING'S BRICK FACADE
(SEE SHEET C-4 FOR MORE DETAIL)
PROPOSED QUASI-OMNI ANTENNA
MOUNTED ON PROPOSED
NON -PENETRATING PEAK MOUNT
(SEE SHEET A-1 FOR MORE DETAIL)
z EXISTING TREES TO
c-z REMAIN AND BE
PROTECTED
(TYP)
EXISTING CURB
(TYP)
EXISTING SIDEWALK
NOTE:
1. NO WIRELESS TELECOMMUNICATION FACILITY OR
EQUIPMENT OWNER OR LESSEE OR EMPLOYEE
THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT
TO EXCLUDE ANY OTHER WIRELESS
TELECOMMUNICATION PROVIDER FROM USING
THIS BUILDING, STRUCTURE OR LOCATION.
1 SITE PLAN (ROOF LEVEL
Z-1 SCALE:1M6"=1'-0"
GRAPHIC SCALE
16 p 8 16 32 64
PROPOSED 5'-0"x10'-0" VERIZON
LEASE AREA
(SEE DETAIL 22-2)
PROPOSED FIBER IN 2" SCH 40 PVC CONDUIT
W/ 3-CELL PLENUM MAXCELL INNERDUCT
(SEE DETAIL 1/C-5)
PROPOSED 5'-0" WIDE ACCESS
AND UTILITY EASEMENT
PROPOSED TRAFFIC RATED
2'-0"x3'-0" FIBER VAULT
(SEE DETAIL 2/C-6)
EXISTING FIBER LINE
IIIII�;,I �
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303)873-2652
AerQS©lutionS LLG
opuftz#tg Your Wrrutesss Jnfrasoucture
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
LF
3
06-22-18
L
2
05-17-18
LU .,
t i VISED CDs
03-29-18 LC`N 100%CDs
0 01-24-18 F ��� :M CDs
REV I DATE I BY I : = 3CRIPTION
DRAWING TITLE
SITE PLAN
(ROOF LEVEL)
DRAWING SHEE
SITE INFORMATION:
SITE NAME:
FTC MUGS COFFEE SC
SITE ADDRESS:
714 S COLLEGE AVE
FT COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
2. ALL EXISTING TRESS TO REMAIN AND BE
PROTECTED.
( IN FEET)
1/16 inch = 1 ft.
(SCALE BASED ON FULL SIZE 24k36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
MIKKO P. AHOLA, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #33495 (EXP. 10/31/2019)
4t-70
MR-70
PROPOSED QUASI-OMNI ANTENNA
MOUNTED ON CUSTOM
NON -PENETRATING PEAK MOUNT
(SEE DETAIL 2/A-1)
PROPOSED FAUX CHIMNEY PAINTED &
TEXTURED TO MATCH EXISTING
BUILDING'S BRICK FACADE
(SEE SHEET C-4 FOR MORE DETAIL)
PROPOSED RUBBER MAT SITEPRO P/N
MAT18 OR APPROVED EQUIVALENT (TYP)
(TRIM TO MATCH SLED DIMENSIONS)
(MATCH ROOF COLOR)
PROPOSED CUSTOM NON -PENETRATING
PEAK ROOF MOUNT
(MATCH ROOF COLOR)
(SEE SHEETS ST-1 THROUGH ST-5 FOR
MORE DETAIL)
1EQUIPMENT PLAN (ROOF LEVEL)
C-1 SCA` _ : 1/8"=1'-0"
GRAPHIC SCALE
4 8 16 32
( IN FEET)
1/8 inch = 1 ft.
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
NOTE:
ALL EXISTING TRESS TO
REMAIN AND BE PROTECTED
I
Call before you dig.
UTILITY NOTIFICATION CENTER
TOLL FREE 1800-227-2600
PROPOSED COAX ROUTED UP
ALONG NEW SHROUDED CABLE
TRAY & THRU EXISTING SOFFIT TO
NEW ANTENNA
EXISTING ROOF UNISTRUT TO PARKING GARAGE WALL
ACCESS LADDER (SEE DETAIL 1/A-2)
PROPOSED PCS RRH MOUNTED ON
PROPOSED SHROUDED UNISTRUT TO PARKING GARAGE WALL
CABLE TRAY (SEE DETAIL 2/A-2)
(SHROUD TO MATCH
EXISTING BUILDING) PROPOSED COAX ROUTED UP
ALONG NEW SHROUDED CABLE
TRAY & THRU EXISTING SOFFIT TO
NEW ANTENNA
PROPOSED EQUIPMENT CABINET
MOUNTED TO PARKING GARGAE WALL
(PAINT GRAY TO MATCH EXISTING WALL)
(SEE DETAIL 1/C-5)
PROPOSED POWER PANEL MOUNTED
TO PARKING GARAGE WALL
PROPOSED ELECTRICAL FROM
EXISTING ELECTRICAL PANEL(H1A)
IN GARAGE TO NEW EQUIPMENT
(ROUTE THROUGH DROP CEILING)
(SEE DETAILS SHEET E-1)
2
C-1
CABLE TABLE
SECTOR AZIMUTH LENGTH NO. `'<.f_ rYE_ V anIIIIIIIIIIIIIIIIII� Oh
b,
e.
3131 SOUTH VAUGHN WAY#500
A N/A 80'-0"" 2 7/8"` OAX AURORA, COLORADO 80014
------- ____.--.-------._._-; (303) 873-2652
NOTES:
1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION
MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING.
2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED
OTHERWISE.
3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY
AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO
INSTALLING ANY ANTENNAS.
SCALE: 1/8"=1'-0"
GRAPHIC SCALE
8 0 4 8 1
( IN FEET)
1/8 inch = 1 ft.
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
32
L
PROPOSED FIBER IN 2" SCH 40
PVC CONDUIT
3PLENUM MAXCELL INNERDLICT
DETAIL
ROOEO5'WIDE ACCESS
AND UTILITY EASEMENT
EXISTING UNDERGROUND GAS
LINE
+Dptknfzing Your �r�te 5
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
T " i<s7-17-0099
?'::VISION SCHEDULE
3 1 06-22-18
2 1 05-ti 7-18
iSED CDs
1 03-29-18 IRPHI
%CDs
0 01-24-18 PRELIM CDs
REV I DATE I BY I DESCRIPTION
DRAWING SHEER.
C=ml
>HE%INUMBER
6 OF 22
SITE NAME:
FTC MUGS COFFEE SC
SITE ADDRESS:
714 S COLLEGE AVE
FT COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
PE-33495
MIKKO P. AHOLA, P E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #33495 (EXP. 10131/2019)
i12-70
Page is too large to OCR.
PROPOSED FAUX CHIMNEY PAINTED &
TEXTURED TO MATCH EXISTING
BUILDING'S FACADE WITH CHIMNEY CAP
PROPOSED QUASI-OMNI ANTENNA MOUNTED ON
CUSTOM NON -PENETRATING PEAK MOUNT
(SEE DETAIL 2/A-1)
PROPOSED ROOFTOP PENETRATION
PROPOSED CUSTOM NON -PENETRATING PEAK ROOF MOUNT
(SLED MEMBERS AND RUBBER PADS TO MATCH ROOF COLOR)
(SEE SHEETS ST-1 THROUGH ST-5 FOR MORE DETAIL)
PROPOSED AWS RRH MOUNTED ON
UNISTRUT TO PARKING GARAGE WALL
(SEE DETAIL 1/A-2)
PROPOSED PCS RRH MOUNTED ON
UNISTRUT TO PARKING GARAGE WALL
(SEE DETAIL 2/A-2)
PROPOSED EQUIPMENT CABINET MOUNTED
TO PARKING GARAGE WALL
(PAINT GRAY TO MATCH EXISTING WALL)
(SEE DETAIL 1/C-5)
PROPOSED POWER PANEL MOUNTED
TO PARKING GARAGE WALL
EXISTING LADDER
PROPOSED COAX ROUTED UP
ALONG NEW 6" SHROUDED CABLE
TRAY & THRU EXISTING SOFFIT TO
NEW ANTENNA
TOP OF ROOF
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
Dylkmztng Yncrt WNrrvkass Ink,
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
AERO PROJECT #: 097-17-0099
REVISION SCHEDULE
3 1 06-22-18 ILCWI REVISED CDs
EXISTING NORTH 2 05-17-18 LCW REVISED CDs
ELEVATION
4
SCALE: 1/8" = 1'-0" 03-29-18 LCW 100%CDs
0 01-24-18 RPH PRELIM CDs
REV DATE BY *'TION
El
I m
W PROP w: D NORTH ELEVATION
8
GRAPHIC SCALE
8
TOP OF PROPOSED SHROUD
8'-4" AGL
'ROPOSED VLRIZON RAD CENTER
44'-9" AGL
TOP OF ROOF
40'-0" AGL
GRADE
0'-0" AGL
I
NOTE:
DRAWIN
NORTH ELEVATIONS
to 046 5rt L L_,.
C�bc
SITE INFORMATION:
SITE NAME:
FTC MUGS COFFEE SC
SITE ADDRESS:
714 S COLLEGE AVE
FT COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
( IN FEET)
1/8 inch = 1 ft.
(SCALE BASED ON FULL SIZE 24'k36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
ALL EXISTING TRESS TO
REMAIN AND BE PROTECTED
MIKKO P. AHOLA, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #33495 (EXP. 10131/2019)
M 2 - 7 0
SPECIFICATIONS
FIBERGLASS REINFORCED PLASTIC (FRP) SHAPES:
1. ALL FRP SHAPES AND PLATE SHALL CONFORM TO STRONGWELL EXTREN 500/525 SERIES.
2. APPLY R�_ IN ADHESIVE TO ALL FRP MATING SURFACES PRIOR TO BOLTING.
3. STRONG ,.-:_!- FIBERBOLTS AND NUTS OR EQUAL.
4. ALL CUT EDGES AND HOLES SHALL BE SEALED WITH A RESIN COMPATIBLE WITH THE RESIN MATRIX USED IN THE STRUCTURAL
SHAPE.
5. THE FABRICATOR AND CONTRACTOR SHALL EXERCISE PRECAUTIONS NECESSARY TO PROTECT THE FIBERGLASS PULTRUDED
STRUCTURAL SHAPES FROM ABUSE TO PREVENT BREAKAGE, NICKS, GOUGES, ETC. DURING FABRICATION, HANDLING, AND
INSTALLATION.
6. STURCTURAL SHAPES SHALL BE FABRICATED AND ASSEMBLED AS INDICATED ON THE DESIGN DRAWINGS.
7. FIBERBOLTS BOLTS AND NUTS SHALL BE TIGHTENED TO AND LOCKED WITH EPDXY AS FOLLOWS:
1/2" DIAMETER NUTS 8 FT-LBS TORQUE
5/8" DIAMETER NUTS 16 FT-LBS TORQUE
3/4" DIAMETER NUTS 24 FT-LBS TORQUE
FIBERGLASS PANEL NOTES: BY LARSON CAMOFLAGE, LLC
- FABRICATE PANELS TO FIT PER DIMENSIONS SHOWN IN PLAN.
- PANELS TO BE MINIMUM 1/4" THICKNESS.
1. PANELS ARE TO BE FABRICATED IN A CONTIGUOUS LAYUP PER PLANS USING RF TRANSPARENT MATERIALS.
2. ARCHITECT SHALL SPECIFY ANY REQUIRED FINISHES OR TREATMENTS TO ACHIEVE DESIRED APPEARANCE.
3. FABRICATOR SHALL USE A GLASS -RESIN RATIO OF 35% + 3%: REINFORCEMENT BY WEIGHT.
4. EACH SKIN SHALL BE FABRICATED WITH GENERAL PERPOSE RESIN OR POLYESTER VINYL RESIN WHERE REQUIRED FOR FIRE
TREATMENT, CHOPPED STRAND MAT.
5. CORNER FLANGES MAY BE FASTENED WITH 5/8" NON-METALLIC THREADED ROD AND NUTS: STRONGWELL FIBERBOLT STUDS
AND NUTS OR EQUIVALENT. A TORQUE WRENCH MUST BE USED TO TIGHTEN FASTENERS TO A MAXIMUM 16 FT-LBS.
6. FRP PANELS AND SHAPES SHALL BE COATED WITH A FLAT GEL -COAT FINISH TO PROVIDE ULTRAVIOLET PROTECTION.
7. ALL CUT AND DRILLED EDGES SHALL BE COATED WITH RESIN.
8. FABRICATOR AND INSTALLER SHALL TEST FIT ALL PANELS PRIOR TO FINAL ASSEMBLY/INSTALLATION TO ASSURE SQUARENESS
AND CORNER FITS.
9. CONTACT KEN PUEHL FOR ADDITIONAL INFORMATION AT 520-741-3115.
BRICK 1
mm�m 4" CHIMNEY CAP
ISED FAUX CHIMNEY CONCEALMENT
ID WITH SPARK ARRESTOR
JD TO BE PAINTED AND TEXTURED
TCH BUILDING BRICK)
ISED QUASI OMNI ANTENNA WITHIN
EY CONCEALMENT SHROUD
ISED ANTENNA MOUNTING PIPE
,.
UX CHIMNEY DETAILS
GRAPHIC SCALE
2
( IN FEET)
1 inch = 1 ft.
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
BRICK 2
1419:9�1Abirwol:lI TjIL1
PROPOSED FAUX CHIMNEY CONCEALMENT
SHROUD WITH SPARK ARRESTOR
(SHROUD TO BE PAINTED AND TEXTURED
TO MATCH BUILDING BRICK)
• BRICK DIMENSIONS: 3 1/4" X 2 1/8" X 7 112"
• GROUT SPACING IS 1/2"
• COLORS:
• 98806F (BRICK 1)
• B09E82 (BRICK 2)
• AA896C (BRICK 3)
TOP OF EXISTING ROOF
lgfr'�vl
I� •
3131 SOUTH VAUGHN WAY#500
AURORA, COLORADO 80014
(303) 873-2652
opbr"mog Your Wroulea:.
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
AF 'ECT#:097-17-0099
REVISION SCHEDULE
3 1 06-22-18 ILCWI REVISED CDs
2
05-17-18
LCW
REVISED CDs
1
03-29-18
LCW
100% CDs
0
01-24-18
RPH
PRELIM CDs
REV
DATE
BY
DESCRIPTION
'RAWING TITLE:
FAM CHIMNFY DETAILS
DRAWING SHEL.,
9 OF 22
SITE INFORMATION:
SITE NAME:
FTC MUGS COFFEE SC
SITE ADDRESS:
714 S COLLEGE AVE
FT COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
MIKKO P. AHOLA, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #33495 (EXP. 10/31/2019)