Loading...
HomeMy WebLinkAboutRIDGEWOOD HILLS FOURTH FILING - Filed FDT-FIELD DENSITY TEST - 2020-01-29 (4)FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 20191099.0035 11/18/19 11/20/19 Site Work / Utilities / CIty ROW 1901 Sharp Point Dr, Ste C Fort Collins, CO 80525-4429 970-484-0359 Client M Timm Development Attn: Bill Timm 233 E Carrillo St Ste D Santa Barbara, CA 93101 Ridgewood Hills Apartments 7363 Avondale Road Fort Collins, CO 80525 Project Project Number: 20191099 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description Test Method (pcf) 1 20191099.0007 Sandy Lean Clay ASTM D698 16.2 108.4 15.2-19.2 Min 95 Field Test Data No. Test Location Elev. No. Test Lift / Mat. Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in) (pcf) (pcf) (pcf) Storm line B backfill - Avondale 1 At Inlet N of Bld 1 (west inlet) -1' 1 8 123.7 17.6 16.6 106.1 98 2 0' 1 8 122.2 17.9 17.2 104.3 96 3 30' East of west inlet -1' 1 8 121.9 17.3 16.5 104.6 96 4 0' 1 8 125.3 17.5 16.2 107.8 99 5 70' East of west inlet -1' 1 8 122.3 17.3 16.5 105.0 97 6 0' 1 8 120.0 15.9 15.3 104.1 96 7 50' West of East inlet (NE of Bld 5) -1' 1 8 122.3 17.1 16.3 105.2 97 8 0' 1 8 120.7 16.4 15.7 104.3 96 9 10' West of East inlet -1' 1 8 120.3 16.2 15.6 104.1 96 10 0' 1 8 122.8 16.7 15.7 106.1 98 Comments: Datum: 0= Finish sewer backfill elevation Std. Cnt. M: 542 Std. Cnt. D: 1756 Test and/or retest results on this report meet project requirements as noted above. S/N: 17271 Make: Troxler Model: 3440 Last Cal. Date: 01/16/2019 Services: Reported To: Contractor: Kim w/ CoFC M. Timm Eric Buol Project Manager Report Distribution: (1) M Timm Development, Bill Timm (1) City Of Fort Collins CO, Kim Keiswetter (1) Dirt One Excavating, Tom Thompson (1) M Timm Development, Kevin Egan (1) M Timm Development, Larry McGee (1) Terracon Consultants, Inc., Eric Bernhardt Reviewed By: Terracon Rep.: Christopher Rivera Test Methods: ASTM D6938 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 1