Loading...
HomeMy WebLinkAboutREGISTRY RIDGE SEVENTH FILING - Filed GC-GENERAL CORRESPONDENCE - 2016-09-13of %mot. f June 18, 2015 Kevin Brazelton, PE United Civil Design Group, LLC 1501 Academy Ct. Ste 203 Fort Collins, CO 80524 Planning, Development & Transportation Engineering Department 281 North College Avenue P.O. Box 580 Fort Collins, CO 80522.0580 970.221.6605 970.221.6378 - fax fcgov. com/engineering Re: Registry Ridge Seventh Filing Variance Request (Minimum Driveway Spacing) Mr. Brazelton, This letter is in response to the variance request letter dated June 18, 2015 regarding a variance request to Table 7-3 of the Larimer County Urban Area Street Standards to reduce minimum driveway spacing. The variance request to reduce the minimum distance between the driveway edges of Saipan Court and the shared driveway for Lot 3 and Lot 4 of Block 1, shown on the Variance Exhibit, from 30' to 23.31' is granted. This request does not set precedence or change the application of our design standards in other situations. If you have any questions, please contact me at 221-6573. Sincerely, Sheri L. Langenberger, P.E. Attachments cc: Martina Wilkinson, Civil Engineer II, Traffic Operations file UNITED CIVIL Design Group June 18, 2015 Engineering Development Review City of Fort Collins Engineering 281 North College Avenue Fort Collins, CO 80521 RE: Registry Ridge Seventh Filing Variance Request Fort Collins, Colorado Project Number: U14012 To whom it may concern: Variance Request Registry Ridge Seventh Filing Fort Collins, CO This letter is in regards to the Registry Ridge Seventh Filing project which is located west of Shield$ Street and south of Trilby Road and is being submitted on behalf of the developer for the project BCC, LLC. The Seventh Filing project is proposing to develop three parcels of Registry Ridge into single family attached and detached lots. The project is currently in the Final Compliance process and at this time a variance is requested to modify a portion of the Larimer County Urban Area Street Standards (LCUASS) as follows: Variance Item Chapter 7 of LCUASS addresses the Street Design and Technical Criteria for public roadways. More specifically, minimum distances between driveway edges are shown in Table 7-3. Enterprise Drive is designated as a local street and therefore, would require a minimum distance between driveway edges of 30-feet for a local commercial/industrial street designation. Alternate Design The area in question along Enterprise Drive is at existing Tract B of Registry Ridge Second Filing on the East side of Enterprise Drive. The area was originally planned for condominium units and required only one driveway connection to Enterprise Drive. With the change in product to single family attached lots, multiple driveway connections are required. Due to the width of the lots and geometry of the existing Tract, the minimum distance of 30-feet has been reduced to approximately 23-feet in one location between Saipan Court and the driveway for Block 1, Lots 3 and 4. Refer to the Variance Request Exhibit attached with this letter. Justification of Variance Enterprise Drive is designated as a local street with a street section that is wider than the typical residential street section. The current section more closely reflects an industrial street UNITED CIVIL Design Group u, Variance Request Registry Ridge Seventh Filing Fort Collins, CO section as shown in Chapter 7 of LCUASS. The change in product type to single family lots with the park land across the street allows the area to function as a typical residential area. LCUASS Table 7-3 requires a minimum of 12-feet between driveway edges for a residential local roadway, significantly less than the proposed 23-feet. It is the opinion of United Civil that the minimum distance between the driveway connections of 23-feet will not be detrimental to the public health, safety and welfare, and will not reduce design life of the improvement nor cause the Local Entity additional maintenance costs. If you should have any questions or comments this variance request please feel free to contact us at your convenience. Sincerely, United Civil Design Group, LLC Kevin Brazelton, PE Engineering Manager CONNNECT TO EXISTING CURB, GUTTER & SIDEWALK TYPE I DRIVEWAY APPROACH 30' EXISTING ANITARY EASEMENT PROPERTY CORNER N:1422191.28 E:3112790.49 LOT 23.31' (PER VARIANCE REQUEST) 1 11i" Civil Engineering & Consulting 1501 Academy Ct., Ste. 203 Fort Collins, CO 80524 UNITED CML (970) 530-4044 Design Group www.unitedcivll.com 36' WIDE DUAL TYPE I DRIVEWAY APPROACH LOT � y . & SIDEWALK N=1422446.86 E=3112857.20 LOT 2 36' WIDE DUAL TYPE I DRIVEWAY APPROACH LOT 1 LOT LOT I N=1422370.90 • DRIVE -OVER EI 3112846.92 F CURB & GUTTER ITYP.) OUTLOT A LOT6 22.25' : SAI.PAN ouR7 : ....:. .; . EP-EP ; • TRACT A :...: :(PRIVATE DRIVE) . ::... 4. :.::. . . BLO K2 2' CURB CUT I I & SIDEWALK CHASE • I LOT • a 36' WIDE DUAL TYPE I DRIVEWAY APPROACH LOT 3 LOT 4 I LOT2 N=1422244.74 E=3112845.39 i PROPERTY CORNER - - - - - - . N:1422196.22 Am 66' ROW — E:3112856.49 IF- � z — — — — — — — — — — — — — — Z 0 20' 40' SCALE: 1" = 40' REGISTRY RIDGE SEVENTH FILING VARIANCE REQUEST EXHIBIT 6/18/2015