HomeMy WebLinkAboutBIG DEAL FOUR PLEX - Filed CS-COMMENT SHEETS - 2016-05-20Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov.com November 13, 2012 Jeff Eggleston 2519 Ridge Creek Rd. Fort Collins, CO 80528 Re: 621 S Meldrum Description of project: This is a request to scrape an existing single family home and construct a 4-plex at 621 South Meldrum Street (Parcel # 9714111011). Each of the four units will be approximately 1,200 square feet, and the overall building 4,800 square feet. The lot is zoned Neighborhood Conservation, Buffer District (N-C-B) and falls within the TOD Overlay Zone. Multi -family dwellings are permitted subject to an administrative (Type 1) review. Please see the following summary of comments regarding the project request referenced above. The comments offered informally by staff during the Conceptual Review will assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you have any questions regarding these comments or the next steps in the review process, you may contact the individual commenter or direct your questions through the Project Planner, Jason Holland, at 970-224-6126 or jholland@fcgov.com. Comment Summary: Department: Zoning Contact: Noah Beals, 970.416.2313, nbealsD-fcgov.com 1. Zoning echo's the comments made by Current Planning. Land Use Code (LUC) 3.2.1 Requires that a Landscaping plan be provided that includes tree mitigation as approved by the City Forester (see section for more details). Response: The provided landscape plan indicates existing trees and how they are to be mitigated. We have had an on -site meeting with the City Forester to evaluate the existing trees. LUC 3.2.4 This section requires a lighting plan which includes a Photometric site plan and catalog cut sheets for fixtures (see section for more details). Response: A lighting plan is provided with the PDP sunmittal. LUC 3.2.5 This is section requires that adequate sized enclosure for trash and recycling be provided that is constructed on a concrete pad and 20ft away from a public sidewalk. Also designed with walk-in access without having to open the main service gate. Department: Technical Services Contact: Jeff County, 970.221.6588, 'county§fcgov.com Topic: Plat Comment Number: 1 Comment Originated: 12/04/2012 12/04/2012: We would like the name to change, as a BDR is a city review process. Comment Number: 2 Comment Originated: 12/04/2012 12/04/2012: The boundary and legal description close. Comment Number: 3 Comment Originated: 12/04/2012 12/04/2012: The name in the Statement Of Ownership And Subdivision does not match the name in the title. Comment Number: 4 Comment Originated: 12/04/2012 12/04/2012: All easements must be locatable. Comment Number: 5 Comment Originated: 12/04/2012 12/04/2012: Please provide both record and measured bearings & distances. Comment Number: 6 Comment Originated: 12/04/2012 12/04/2012: Please make the set & found monument symbols the same size in the legend and on the boundary. Comment Number: 7 Comment Originated: 12/04/2012 12104/2012: Please add a distance to the found property corner on the west side of the alley. See redlines. Comment Number: 8 Comment Originated: 12/04/2012 12/04/2012: Is the found pin at the southeast corner of the boundary at the accepted corner? Graphically it does not look like it. If it is not, show bearing & distance to accepted comer. Comment Number: 9 Comment Originated: 12/04/2012 12/04/2012: If the Athur Ditch easement is existing, please note. If it is being dedicated by this plat, a signature block & a signature by an appropriate Ditch Company representative is required. The signature block must acknowledge & accept the easement dedication. Comment Number: 10 Comment Originated: 12/04/2012 12/04/2012: Are there any lienholders? If so, please add a Lienholders signature block. Comment Number: 11 Comment Originated: 12/04/2012 12/04/2012: Please change "measured" to "assumed" in the Basis Of Bearings statement (Note #1). Comment Number: 12 Comment Originated: 12/04/2012 12/04/2012: Are there any easements being vacated by this plat? Comment Number: 13 Comment Originated: 12104/2012 12/04/2012: Please correct the labels to the east of the property in Block 96. Comment Number: 14 Comment Originated: 12/04/2012 12/04/2012: Please add "Basis Of Bearings" to the north line of the property. Comment Number: 15 Comment Originated: 12/04/2012 12/04/2012: Why is this property being replatted? Department: Technical Services Contact: Jeff County, 970.221.6588, jcounty@fcgov.com Topic: Site Plan Comment Number: 16 Comment Originated: 12/04/2012 12/04/2012: The project name does not match the Subdivision Plat. We are suggesting that the Subdivision Plat name change, so this may need to change. Comment Number: 17 Comment Originated: 12/04/2012 12/04/2012: There are line over text issues. Comment Number: 18 Comment Originated: 12/04/2012 12/04/2012: The Owner's Certification of Approval shows Elizabeth And City Park Corner LLC as the owner. is this correct? Department: Water -Wastewater Engineering Contact: Roger Buffington, 970.221-6854, rbuffinaton �fcgov.com Topic: Construction Drawings Comment Number: 1 Comment Originated: 12/04/2012 12/04/2012: Add the curb stop and meter pit at the front of the lot preferably between the curb and sidewalk. Get locates on gas and electric in that area and show on plans. Comment Number: 2 Comment Originated: 12/04/2012 12/04/2012: Revise note on tapping saddle as shown on the redlined plans. Comment Number: 3 Comment Originated: 12/04/2012 12/04/2012: Show a minimum of 3 feet between the domestic service and the fire line. Department: Zoning Contact: Peter Barnes, 970.416.2355, abarnes aOfcaov.com Topic: Building Elevations Comment Number: 5 Comment Originated: 11/26/2012 11/26/2012: The wall height of the stair enclosure on the south side appears to be 21.5'. This requires a side setback of 7' per 4.9(D)(6)(d). The setback distance isn't shown on the site plan, but it scales to less than 7'. Comment Number: 6 Comment Originated: 11/26/2012 11/26/2012: label the finished grade line on the elevations. Topic: Site Plan Comment Number: 1 Comment Originated: 11/26/2012 11/26/2012: General note #13 on the site plan needs to be removed. It doesn't apply to this project. Comment Number: 2 Comment Originated: 11/26/2012 11/26/2012: The applicant's conceptual review response letter indicates that the 14' front building setback matches the existing contextual setback. Documentation will be needed verifying the front setback of one or both of the buildings on abutting lots. Department: Zoning Contact: Peter Barnes, 970.416.2355, Rbarnes a@fcgov.com Topic: Site Plan Comment Number: 3 Comment Originated: 11/26/2012 11/26/2012: The parking stall depth for residential parking needs to be a minimum of 18'. This distance can be reduced to 16' if the space overhangs a minimum 6' wide landscape area (Sec. 3.2.2(L)(4)). The site plan shows 16' deep stalls, but doesn't dimension the width of the landscape setback. Putting a scale on the drawing, the setback is less than 6% meaning the stalls would need to be Win depth. Comment Number: 4 Comment Originated: 11/26/2012 11/26/2012: Label the surface material of the parking lot (asphalt or concrete). Comment Number: 7 Comment Originated: 11/26/2012 11/26/2012: New 6' privacy fence is labeled along north lot line. A similar fence is required along the south lot line for the parking area. A fence appears to be shown on the plan. Please label the height of the fence and whether its new or existing. ~. the back portion of the site will receive water quality through an extended detention area. 4. The Arthur Irrigation Ditch crosses the property. All improvements must be 10 feet away from both sides of the ditch. If you have questions concerning the ditch contact the President, Mark Taylor at 416-2494 or mtaylor@fcgov.com. He must approve the construction plans prior to Stormwater approval of the plans. Response: An easement has been created for the Arthur Irrigation Ditch. 5. The city wide Stormwater development fee (PIF) is $6,390.00/acre ($0.1467/sq.ft.) for new impervious area over 350 sq.-ft., and there is a $1,045.00/acre ($0.024/sq.ft.) review fee. No fee is charged for existing impervious area. These fees are to be paid at the time each building permit is issued. Information on fees can be found on the City's web site at http://www.fcgov.com/utilities/business/builders-and-developers/plant-investment-development-fees or contact Jean Pakech at 221- 6375 for questions on fees. There is also an erosion control escrow required before the Development Construction permit is issued. The amount of the escrow is determined by the design engineer, and is based on the site disturbance area or a minimum amount in accordance with the Fort Collins Stormwater Design Criteria. Response: Acknowledged 6. The design of this site must conform to the drainage basin design of the Old Town Master Drainage Plan as well the City's Stormwater Criteria Manual. Response: Acknowledged 7. At the conceptual review meeting a new drawing was shown that proposed parking over the Arthur irrigation ditch which is a concern for the ditch company. Also during a site visit it was noted that there is a concrete slab crossing diagonally across the property. That is the top of the ditch so it is easy to locate. The concern is that the ditch is not structurally sound enough to carry continuous automobile or especially truck traffic loads. Either the ditch will need to be replaced with a box culvert or a structural engineer needs to certify that it is structurally sound to take the loads. It is the experience of the Ditch Company that the ditch section cannot take the traffic loads which is why many street crossings of the ditch have been and are being replaced. Response: The parking lot over the ditch section has been removed. 8. Also during the site visit I noticed that the storm drain in the alley that discharges into the Arthur Ditch is taking flow from an inlet to the south at the alley intersection and even though the pipe flow is to the north, the surface of the alley flows to the south. I don't think this storm drain will be useful to this project even if it was allowed since the alley it the high side of the development site. (Discharges of runoff into irrigation ditches has not been allowed since 1984) Response: Through conversation with Mark Taylor, he has allowed us to discharge continuated runoff from the on -site detention pond to the existing inlet structure. Department: Park Planning Contact: Craig Foreman, 970-221-6618, cforeman@fcgov.com 1. 1.9/28/12: No comments Department: Historical Preservation Contact: Josh Weinberg, 970-221-6206, jweinberg(Mcgov.com 1. In May 2012, this property was reviewed for its eligibility for Landmark designation by the CDNS Director and LPC Chair, per Municipal Code Section 14-72. The property was not found to be eligible for �Afflq Department: Engineering Development Review Contact: Tyler Siegmund, 970.221.6501, tsiegmundCcilfcgov.com 1. Ladmer County Road Impact Fees and Street Oversizing Fees are due at the time of building permit. Please contact Matt Baker at 224-6108 if you have any questions. Response: Acknowledged. 2. The City's Transportation Development Review Fee (TDRF) is due at the time of submittal. For additional information on these fees, please see: hftp://www.fcqov.com/engineering/dev-review.pho Response: Acknowledged. 3. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets, sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of this project, shall be replaced or restored to City of Fort Collins standards at the Developer's expense prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. Response: Acknowledged. 4. Please contact the City's Traffic Engineer, Joe Olson (224-6062) to schedule a scoping meeting and determine if a traffic study is needed for this project. In addition, please contact Transportation Planning for their requirements as well. Response: Ward Stanford was contacted and a traffic study will not be required for this project. 5. Any public improvements must be designed and built in accordance with the Larimer County Urban Area Street Standards (LCUASS). They are available online at: hfti)://www.ladmer.org/engineedng/GMARdStds/UrbanSt.htm Response: Acknowledged. 6. This project is responsible for dedicating additional right-of-way and easements that are necessary for this project. Response: No Additional ROW is required along Meldrum 7. Construction plans will be required. Response: Acknowledged. 8. A Development Agreement is required and will be recorded once the project is finalized with recordation costs paid for by the applicant. Response: Acknowledged. Department: Engineering Development Review Contact: Tyler Siegmund, 970.221-6501, tsiegmund(Mcgov.com 9. A Development Construction Permit (DCP) will need to be obtained prior to starting any work on the site. Response: Acknowledged. 10. Depending on the existing condition of the alley behind and adjacent to the property, alley improvements may be required with the project. A site meeting can be scheduled to determine if alley improvement will apply. Response: Acknowledged. 11. LCUASS parking setbacks (Figure 19-6) may apply depending on the design of the parking in the rear of the lot off of the alley. Contact me for more information Response: The building is 2 stories 9. All exterior walls of a building that are greater than six (6) feet in length shall be constructed parallel to or at right angles to the side lot lines of the lot whenever the lot is rectilinear in shape. Response: Acknowledged. 10. The primary entrance to a dwelling shall be located along the front wall of the building, unless otherwise required for handicap access. Such entrance shall include an architectural feature such as a porch, landing or portico. Response: All units have recessed entries with 1-story porch roof elements. 11. Accessory buildings and attached garages shall have a front yard setback that is at least ten (10) feet greater than the front setback of the principal building that is located on the front portion of the lot. Response: Acknowledged. 12. A second floor shall not overhang the lower front or side exterior walls of anew or existing building. Response: Acknowledged. 13. Front porches shall be limited to one (1) story, and the front facades of all single- and two-family dwellings shall be no higher than two (2) stories, except for carriage houses and accessory buildings containing habitable space, which shall be limited to one and one-half (1'/2) stories. Response: All units have recessed entries with 1-story porch roof elements. 14. The minimum pitch of the roof of any building shall be 2:12 and the maximum pitch of the roof of any building shall be 12:12. Additionally, the roof pitch of a dormer, turret or similar architectural feature may not exceed 24:12 and the roof pitch of a covered porch may be flat whenever the roof of such a porch is also considered to be the floor of a second -story deck. Response: Minimum roof slope on project is 3:12 pitch. 15. The exterior eave height of an eave along a side lot line shall not exceed thirteen (13) feet from grade for a dwelling unit located at the rear of the lot or an accessory building with habitable space. Response: Does not apply to this project. 16. If a second story has an exterior wall that is set back from the lower story's exterior wall, the eave height shall be the point of an imaginary line at which the upper story's roofline (if extended horizontally) would intersect with the lower story's exterior wall (if extended vertically). (See illustration contained in Division 4.7.) Response: Does not apply to this project. 17. A maximum of forty (40) percent of the front yard of a lot may be covered with inorganic material such as asphalt or cement concrete, paving stone, flagstone, rock or gravel. Response: Acknowledged. 18. In the N-C-B Neighborhood Conservation Buffer District, permanent open off-street parking areas shall not be located any closer to a public street right-of-way than the distance by which the principal building is set back from the street right-of-way. This provision shall not be construed to preclude temporary parking in driveways. Response: Acknowledged. Does not apply to this project. 19. Whenever a lot has frontage along an alley, any new off-street parking area located on such lot must obtain access from such adjoining alley; provided, however, that such alley access shall not be required when a new detached garage is proposed to be accessed from an existing driveway that has a curbcut along a public street, or when alley access is determined by the City Engineer to be a hazard to persons or vehicles. Response: Acknowledged. We don't have this condition. ram - Response: Acknowledged. 31. When you are ready to submit your formal plans, please make an appointment with Community Development and Neighborhood Services at (970)221-6750. Response: Acknowledged. Pre -Submittal Meetings for Building Permits Pre -Submittal meetings are offered to assist the designer/builder by assuring, early on in the design, that the new commercial or multi -family proiects are on track to complying with all of the adopted City codes and Standards listed below. The proposed project should be in the early to mid -design stage for this meeting to be effective and is typically scheduled after the Current Planning conceptual review meeting. Applicants of new commercial or multi -family projects are advised to call 416-2341 to schedule a pre -submittal meeting. Applicants should be prepared to present site plans, floor plans, and elevations and be able to discuss code issues of occupancy, square footage and type of construction being proposed. Construction shall comply with the following adopted codes as amended: 2009 International Building Code (IBC) 2009 International Residential Code (IRC) 2009 International Energy Conservation Code (IECC) 2009 International Mechanical Code (1MC) 2009 International Fuel Gas Code (IFGC) 2009 International Plumbing Code (IPC) as amended by the State of Colorado 2011 National Electrical Code (NEC) as amended by the State of Colorado Accessibility: State Law CRS 9-5 & ICC/ANSI Al 17.1-2003. Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF. Frost Depth: 30 inches. Wind Load:100- MPH 3 Second Gust Exposure B. Seismic Design: Category B. Climate Zone: Zone 5 Energy Code Use 1. Single Family; Duplex; Townhomes: 2009 IRC Chapter 11 or 2009 IECC Chapter 4 2. Multi -family and Condominiums 3 stories max: 2009 IECC Chapter 4. 3. Commercial and Multi -family 4 stories and taller: 2009 IECC Chapter 5. Fort Collins Green Code Amendments effective starting 1-1-2012. A copy of these requirements can be obtained at the Building Office or contact the above phone number. City of Fort Collins Building Services City of 'Oev December 05, 2012 Cathy Mathis The Birdsall Group Berthoud, CO 80513 RE: Big Deal Four Plex, PDP120030, Round Number 1 Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6760 970.224.6134 - fax fcgo v. com/developmentreview Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Jason Holland, at 970-224-6126 or jholiand@fcgov.com. Comment Summary: Department: Current Planning Contact: Jason Holland, 970-224.6126, jhollandbfcgov.com Topic: Building Elevations Comment Number: 1 Comment Originated: 12/04/2012 12/04/2012: You may want to consider further emphasizing the entrance porches, possibly by changing the roof material to metal to make these areas more distinct. Topic: General Comment Number: 1 Comment Originated: 12/04/2012 The drive isle appears to be 23 feet wide, 24 feet is the standard dimension. Topic: Landscape Plans Comment Number: 1 Comment Originated: 12/04/2012 12/04/2012: You may want to consider plant choices along the front sidewalk in addition to Avena Grass, such as Bouteloua gracilis'Blonde Ambition' or a muhly grass. Possibly two Joint Fir flanking the entrance at the street sidewalk could be interesting. Department: Engineering Development Review Contact: Tyler Siegmund, 970.221.6501, ti2gmund _fcgov.com Topic: General Comment Number: 6 Comment Originated: 12/04/2012 12/04/2012: 3. The cross -sections provided on sheet C3 are both labeled A -A but the plan references cross-section B-B. Also, please show the property lines in relation to the proposed retaining walls to clarify that the walls do not encroach on the properties to the north and south. Department: Engineering Development Review Contact: Tyler Siegmund, 970.221.6501, tsieamund fcgov.com Topic: General Comment Number: 7 Comment Originated: 12/04/2012 12/04/2012: A temporary construction easementlagreement from the adjacent property owners will be required for the concrete retaining wall construction on the north and south property lines. Comment Number: 8 Comment Originated: 12/04/2012 12/04/2012: Arthur Ditch representatives will need to review and sign the utility plans Comment Number: 9 Comment Originated: 12/04/2012 12/04/2012: The existing sidewalk along the frontage of the property does not currently meet our minimum sidewalk width requirements for a residential local street. If 50 percent or more of the existing sidewalk is removed or damaged as part of the construction of this project then a new 4.5 foot wide sidewalk will be required with the developer responsible for the costs associated. Please add a note referencing this to the plans. Comment Number: 10 Comment Originated: 12/04/2012 12/04/2012: There are concerns about the proposed roof drain on the south side of the property that extends into the right-of-way and daylights into the curb and gutter. Please provide more information about the proposed depth of this roof drain in the right-of-way or redesign to terminate the drain at the back of sidewalk and run the water through a sidewalk chase and channel to the curb and gutter Comment Number: 11 Comment Originated: 12/04/2012 12/04/2012: You are showing approximate asphalt patching limits on sheet C1, please add our street cut note to all sheets that show approximate patching limits. Comment Number: 12 Comment Originated: 12/04/2012 12/04/2012: Please update General Note #5 Comment Number: 13 Comment Originated: 12104/2012 12/04/2012: Please revise General Note #34 to reference the City of Fort Collins Comment Number: 14 Comment Originated: 12/04/2012 12/04/2012: Construction details were not included with this submittal Comment Number: 15 Comment Originated: 12/04/2012 12/04/2012: Proposed utility plan and profiles were not included with this submittal. Topic: Plat Comment Number: 1 Comment Originated: 12/04/2012 12/04/2012: Please add our Site Distance Easement Restrictions language to the plat- contact me for an updated copy of this language. Comment Number: 2 Comment Originated: 12/04/2012 12/04/2012: Easements dedicated on the plat need to be locatable. The site distance easement dimensions are not clear. Comment Number: 3 Comment Originated: 12/04/2012 12/04/2012: Arthur Ditch representatives will need to sign the plat. Department: Engineering Development Review Contact: Tyler Siegmund, 970.221.6501, tsiggmundAfcgov-com Topic: Plat Comment Number: 4 Comment Originated: 12/04/2012 12/04/2012: The current standard for utility easements along alleys are 8 feet wide. See LUCASS figure 7-11 F. Comment Number: 5 Comment Originated: 1210412012 12/04/2012: Please add our standard note to the plat -"There shall be no private conditions, covenants or restrictions that prohibit or limit the installation of resource conserving equipment or landscaping that are allowed by Sections 12-120—12-122 of the City Code." Department: Environmental Planning Contact: Lindsay Ex, 970.224.6143, lex ,,fcaov.com Topic: General Comment Number: 1 Comment Originated: 11/30/2012 11/30/2012: No comments. Department: PFA Contact: Jim Lynxwiler, 970-416.2869, ilynxwiler _aoudre-fire.ora Topic: General Comment Number: 01 Comment Originated: 12/04/2012 12/04/2012: PREMISE IDENTIFICATION Address numbers shall be visible from the street fronting the property, plainly visible, and posted with a minimum of six-inch numerals on a contrasting background. 2006 International Fire Code 505.1 Comment Number: 02 Comment Originated: 12/04/2012 12/04/2012: BALCONIES AND DECKS Sprinkler protection shall be provided for exterior balconies, decks, and ground floor patios of dwelling units where the building is of Type V construction. 2006 International Fire Code 903.3.1.2.1 Comment Number: 03 Comment Originated: 12/04/2012 12/04/2012: KEY BOXES REQUIRED Poudre Fire Authority requires at least one key box ("Knox Box") to be mounted in approved location(s) on every new building equipped with a required fire sprinkler or fire alarm system. The top shall not be higher than 6 feet above finished floor. 2006 International Fire Code 506.1 and Poudre Fire Authority Bureau Policy 88-20 Department: Stormwater Engineering Contact: Wes Lamarque, 970.416.2418, wlamaraueffcgov.com Topic: General Comment Number: 1 Comment Originated: 12/04/2012 12/04/2012: Is the piping that drains the roof sized for the 100-yr storm. i Department: Stormwater Engineering Contact: Wes Lamarque, 970.416.2418, wlamarque@fcgov.com Topic: General Comment Number: 2 Comment Originated: 12/04/2012 12/04/2012: The retaining walls look toy be in conflict with existing trees that are located on adjacent properties and may compromise the health of these. Comment Number: 3 Comment Originated: 12/04/2012 12/04/2012: A pld with an underdrain may be the best treatment for the water quality pond. Department: Technical Services Contact: Jeff County, 970.221.6588, jcountypfcgov.com Topic: Building Elevations Comment Number: 22 Comment Originated: 12/05/2012 12/05/2012: We are suggesting that the Subdivision Plat name change, so this may need to change. Topic: Construction Drawings Comment Number: 24 Comment Originated: 12/05/2012 12/05/2012: We are suggesting that the Subdivision Plat name change, so this may need to change. Comment Number: 25 Comment Originated: 12/05/2012 12/05/2012: The sub -title should match the Subdivision Plat. Comment Number: 26 Comment Originated: 12/05/2012 12/05/2012: The descriptions of benchmark CSU2 on sheets C0.00 & C0.01 do not match the published City of Fort Collins Vertical Control Network description. Comment Number: 27 Comment Originated: 12/05/2012 12/05/2012: There are line over text issues on sheets C1.00, C2.00 & C3.00. Topic: Landscape Plans Comment Number: 19 Comment Originated: 12/04/2012 12/04/2012: The project name does not match the Subdivision Plat. We are suggesting that the Subdivision Plat name change, so this may need to change. Comment Number: 20 Comment Originated: 12/05/2012 12/05/2012: There are line over text issues. Comment Number: 21 Comment Originated: 12/05/2012 12/05/2012: There is a text over text issues. Topic: Lighting Plan Comment Number: 23 Comment Originated: 12/05/2012 12/05/2012: We are suggesting that the Subdivision Plat name change, so this may need to change. Topic: Plat