HomeMy WebLinkAboutNEW BELGIUM BREWERY FOURTH LIQUID CENTER ADDITION - Filed CS-COMMENT SHEETS - 2016-05-18Crail
rt ins
October 27, 2015
Paul Mills
RUSSEL + MILLS STUDIOS
141 S COLLEGE AVENUE
Fort Collins, CO 80524
Community Developmentand
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6760
970.224.6134 - fax
fcgov. com/developmentrevie w
RE: New Belgium Brewing Liquid Center Expansion, MA150091, Round Number 1
Please see the following summary of comments from City staff and outside reviewing agencies for
your submittal of the above referenced project. If you have questions about any comments, you may
contact the individual commenter or direct your questions through the Project Planner, Ali van
Deutekom, at 970-416-2743 or avandeutekom@fcgov.com.
Department: Planning Services
Contact: Ted Shepard, 970-221-6343, tthgpard0ffegov.com_
Topic: General
Comment Number: 1. Comment Originated: 10/21/2015
10/21/2015: Has the tree mitigation on sheet LD 101 been approved by the City
Forester? Has it been determined that the Ginnala Maple needs zero mitigation?
And, for the. White Ash, the mitigation does not specify the size of the mitigation tree.
Given the issues with the Emerald Ash Borer, what is the species of the mitigation
tree?
- The tree mitigation chart was approved during the Office Expansion minor
amendment. We inventoried all of the trees during the same appointment. There are
no mitigation trees required. LD101 sheet title has been changed to "Tree Protection
and Removal Plan". The Ginnala Maple is in "fair —" condition, so we determined that
it does not require any mitigation trees. The White Ash is to remain, so we are not
specifying a mitigation tree.
Comment Number: 2. Comment Originated: 10/21/2015
10/21/2015: On sheet LD 101, the tree mitigation chart is confusing. For trees that
are to be protected, there is a column that indicates a mitigation amount.
- The tree mitigation chart is organized the same way as the Office Expansion minor
amendment was. Tim still stated the amount of tree mitigation during our inventory,
even if that specific tree is to be remained, for reference.
Comment Number: 3. . Comment Originated: 10/21/2015
10/21/2015: On Sheet LP 001, the Landscape Schedule does not indicatewhich
trees are the mitigation trees.
- There are no trees to be mitigated. LD101 sheet title has been changed to "Tree Protection
and Removal Plan".
Page 1 of 4
Re uired Action Maintenance Objective Frequency of Action
Inspect the downspout and basin to
ensure the system functions as it was Routine
Inspections designed. Repair or replace damaged
downspouts as needed.
Routine -just before annual storm seasons (i.e.,
Sediment, Debris Remove debris and litter from the basin. April/May); at the end of storm season after leaves
and Litter removal Remove sediment from the sump. have fallen; and following significant rainfall events.
Perforated Subdrain Maintenance Plan
The perforated subdrain system storm drain outfall at the bottom of the Modular Block Paver (MBP) system is critical
to the overall function of the paver subbase. As such, special maintenance has been identified to ensure these
perforated drain systems perform as they were designed.
Perforated subdrains leading away from the MBP system is designed to provide faster release of water when
accumulation occurs under the MBP system. Outflow should be seen into downstream storm boxes. if not seen it is
recommended that the system is inspected using a video camera to verify no clogging has occurred.
Perforated subdrains leading toward the MBP system are designed to provide an opportunity for infiltration. These
subdrains often lead to a drywell where additional infiltration capacity is available to reduce runoff per the stated LID
goals adopted by the City.
Routine Maintenance Table
Required Action Maintenance Objective Frequency of Acaon
Use a video camera to inspect the
condition of the perforated drain pipes.
Inspection Cleanout pipes as needed. If the integrity Every two to five years.
of the pipe is compromised, then repair
the damaged section(s)
Where accessible, expose inlet and/or
Inspection outlet of perforated pipe and watch for Minimum Annually
water inflow and/or outflow.
11
Storm Dr^in Linec Maintenance Plan
The storm drain lines are located in proximity to trees. The situation is unavoidable; therefore, special maintenance has
been identified to ensure these storm drain systems perform as they were designed.
Routine Maintenance Table
Required Action Maintenance Objective Frequency of Action
Use a video camera to inspect the
condition of the storm drain pipes.
Inspection Cleanout pipes as needed. If the integrity Every two to five years.
of the pipe is compromised, then repair
the damaged sections .
Dry Extended Detention Basin Routine Maintenance Table (Summary from Table EDB-1, Chapter 6 of UDFCD)
Required Action Maintenance Objective Frequency of Action
Occasional mowing to limit unwanted
Lawn mowing and vegetation. Maintain irrigated turf grass as Routine - Depending on aesthetic requirements.
Lawn care 2 to 4 inches tall and non -irrigated native
turf grasses at 4 to 6 inches.
12
Sediment, Debris
and Litter removal
Remove sediment, debris and litter from
the entire pond to minimize outlet
clogging and improve aesthetics.
Routine - Including just before annual storm
seasons (that is, April and May), end of storm
season after leaves have fallen, and following
significant rainfall events.
Non -routine - Performed when sediment
accumulation occupies 20 percent of the WQCV.
Major Pond
Remove accumulated sediment from the
This may vary considerably, but expect to do this
Sediment removal
bottom of the basin.
every 10 to 20 years, as necessary per inspection
if no construction activities take place in the
tributary watershed. More often if they do.
Inspect basins to insure that the basin
continues to function as initially intended.
Routine - Annual inspection of hydraulic and
Examine the outlet for clogging, erosion,
structural facilities. Also check for obvious
Inspections
slumping, excessive sedimentation levels,
problems during routine maintenance visits,
overgrowth, embankment and spillway
especially for plugging of outlets.
integrity, and damage to any structural
element.
Bioretention/Bioswale Routine Maintenance Table (Summary from Chapter 6 of UDFCD)
Required Action Maintenance Objective
Frequency of Action
Occasional mowing of grasses and weed
Lawn mowing and removal to limit unwanted vegetation.
Routine - Depending on aesthetic requirements,
vegetative care Maintain irrigated turf grass as 2 to 4
planting scheme and cover. Weeds should be
inches tall and non -irrigated native turf
removed before they flower.
grasses at 4 to 6 inches.
Remove debris and litter from
bioretention area and upstream concrete
forebay to minimize clogging of the sand
media. Remove debris and litter from the
pond area and outlet orifice plate to
Routine - Including just before annual storm
Debris and litter
minimize clogging. Remove debris and
seasons and after snow season (April or May), end
removal and snow
litter from curb channel and sidewalk
of storm season after leaves have fallen, and
stockpiling
chase outlets adjacent to pond if
following significant rainfall events.
applicable to minimize clogging. Avoid
stockpiling snow in the bioretention area
to minimize clogging from sediment
accumulation.
Inspect detention area to determine if the
sand media is allowing acceptable
infiltration. If standing water persists for
Routine - Biannual inspection of the hydraulic
Inspections
more than 24 hours after storm runoff has
performance.
ceased, clogging should be further
investigated and remedied.
13
Non -routine - Performed when clogging is due to
the migration of sediments deep into the pore
Growing media Restore infiltration capacity of spaces of the media. The frequency of
replacement bioretention facilities. replacement will depend on site -specific pollutant
loading characteristics.
14
FOURTH AMENDMENT TO JUNE 16, 2006, DEVELOPMENT AGREEMENT BETWEEN
THE CITY OF FORT COLLINS AND NEW BELGIUM BREWING COMPANY INC
THIS AMENDMENT AGREEMENT, made and entered into this day of October,
2015, by and between the CITY OF FORT COLLINS, COLORADO, a Municipal Corporation,
hereinafter referred to as the "City"; and NEW BELGIUM BREWING COMPANY INC., a
Colorado Corporation, hereinafter referred to as the "Developer."
WITNESSETH;
WHEREAS, the City entered into a Development Agreement with the Developer on June
16, 2006, the terms of which govern the development activities of the Developer pertaining to
that certain real property situated in the County of Larimer, State of Colorado, (hereafter referred
to as the "Property") and legally described as follows, to wit:
Lot 1 of New Belgium Brewery Fourth Filing, City of Fort Collins, County of Larimer,
State of Colorado.
WHEREAS, the Development Agreement was amended by Amendment Agreement No.
1 on December 24, 2008, by Amendment Agreement No. 2 on January 2, 2012, and by
Amendment Agreement No. 3 on June 27, 2012.
WHEREAS, the parties presently desire to again modify the Development Agreement by
this Amendment Agreement No. 4;
NOW, THEREFORE, in consideration of the promises of the parties hereto and other
good and valuable consideration, the receipt and adequacy of which are hereby acknowledged,
the parties hereto agree to amend the terms and conditions of the Development Agreement as
follows:
A. Subheading II (Special Conditions) Paragraph C. L(c) shall be added as follows:
(c) All on -site and off -site storm drainage improvements associated with the Office
Addition for this Development, as shown on the Final Development Plan Documents, shall
be completed by the Developer in accordance with said Final Development Plan Documents
prior to the issuance any certificate of occupancy. Completion of improvements shall include
the certification by a professional engineer licensed in Colorado that the drainage facilities
which serve this Development have been constructed in conformance with said Final
Development Plan Documents. Said certification shall be submitted to the City at least two
weeks prior to the issuance of any certificate of occupancy in this Development.
B. Subheading II (Special Conditions) Paragraph C.2 shall be replaced in its entirety as
follows:
2. The Developer shall be responsible for maintaining the structural integrity and
operational function of all drainage facilities constructed as part of this Development
including, but not limited to, all drainage facilities and water quality features, extended
detention water quality basins, bioretention facilities and/or permeable pavement systems.
These drainage facilities and/or features must be maintained in their original operational
integrity throughout the build -out of this Development, following the completion of the
construction of said facilities and features, and after acceptance of said facilities and features
as certified to the City. If at any time following construction and certification (as required
pursuant to Paragraph II.C.1 above) or during the construction of additional structures and/or
lots within this Development, the City determines that said drainage facilities and features no
longer comply with the Final Development Plan Documents, the City must give written
notice to the Developer of all items that do not comply with the Final Development Plan
Documents and request the restoration of the drainage facilities and features back to the
function, standards and specifications designed and specified in the Final Development Plan
Documents. Failure to maintain the structural integrity and operational function of said
drainage facilities and features following certification will result in the withholding of the
issuance of additional building permits and/or certificates of occupancy and, in addition, the
City may avail itself of any other legal remedy that may be provided in the City Code, the
Land Use Code and/or this Development Agreement until said drainage facilities and water
quality features are repaired and restored to the physical characteristics, operational function
and structural integrity originally specified in the Final Development Plan Documents
approved by the City for this Development.
C. Subheading II (Special Conditions) Paragraph C.4 shall be replaced in its entirety with
the following:
4. It is important that all lots be graded to drain in the configuration shown on the Final
Development Plan Documents. For this reason the following requirements shall be followed
for all buildings/structures on all lots:
Prior to the issuance of a certificate of occupancy for any lot or building the Developer shall
provide the City with certification that the lot and/or the building has been graded correctly.
This grading certification shall demonstrate that the lot or building finish floor elevation has
been built in accordance with the elevation specified on the Final Development Plan
Documents. The certification shall also show that the minimum floor elevation or minimum
opening elevation for any building constructed is in compliance with the minimum elevation
as required on the Final Development Plan Documents. The certification shall demonstrate
as well that any minor swales adjacent to the building or on the lot have been graded
correctly and in accordance with the grades shown on the Final Development Plan
Documents. The certification shall also show that the elevations of all corners of the lot are in
accordance with the elevations shown on the Final Development Plan Documents. Said
certification shall be completed by a Colorado licensed professional engineer and shall be
submitted to the City at least two weeks prior to the requested date of issuance of the
applicable certificate of occupancy.
101
D. Subheading II (Special Conditions) Paragraphs C.6 and 7 shall be replaced in their
entirety as follows:
6. The Developer shall be responsible for maintenance of all storm drainage facilities
that are constructed outside of the public right-of-way per the Standard Operating Procedures
(SOPs) contained in Exhibit E.
7. The drainage design for this Development provides for the evacuation of storm
drainage runoff in a reasonable amount of time through a bioretention facility and into the
drainage outfall system. The facility has been designed to discharge stormwater runoff from
frequent storms over a 12-hour period. Under the intended operation of the facility, there
will not be standing water in the pond more than 24 hours after the end of a rainfall event. If
after construction and acceptance of the facility associated with this Development, surfacing
or standing water conditions persist; and if such conditions are beyond what can be expected
in accordance with the approved stormwater design, the Developer shall promptly, upon such
discovery, take appropriate action in order to return the facility to the designed operation per
the Final Development Plan Documents.
E. Subheading II (Special Conditions) Paragraphs C. 9 and 10 shall be added as follows:
9. The Developer agrees to provide and maintain erosion and sediment control
improvements for the Office Addition as shown on the Final Development Plan Documents
until all disturbed areas in and adjacent to this Development's construction activities are
stabilized. The Developer shall also be required to post a security deposit in the amount of
$9,870.75 (nine thousand eight hundred and seventy dollars and seventy-five cents) prior to
beginning construction to guarantee the proper installation and maintenance and, upon
completion, removal of the erosion and sediment control measures shown on the Final
Development Plan Documents. Said security deposit(s) shall be made in accordance with
the criteria set forth in the City's Storm Drainage Design Criteria and Construction Standards
("Criteria"). If, at any time, the Developer fails to abide by the erosion control provisions of
the Final Development Plan Documents or the erosion control provisions of the Criteria after
receiving notice of the same or an emergency situation exists which would reasonably
require immediate mitigation measures, then, in either event, and notwithstanding any
provisions contained in Paragraph III.J to the contrary, the City may enter upon the Property
for the purpose of making such improvements and undertaking such activities as may be
necessary to ensure that the provisions of said plans and the Criteria are properly enforced.
The City may apply such portion of the security deposit(s) as may be necessary to pay all
costs incurred by the City in undertaking the administration, construction, and/or installation
of the erosion control measures required by said plans and the Criteria. In addition, the City
shall have the option to withhold building permits and certificates of occupancy, as stated in
Paragraph III.D of this Agreement, as it deems necessary in order to ensure that the
Developer installs, maintains, and ultimately removes the erosion and sediment control
measures throughout the build -out of this Development. Upon stabilization of the disturbed
areas, and upon the request of the Developer, the City will confirm that the site is stabilized
3
from potential erosion and sediment control issues from the construction activities and that
all temporary erosion and sediment control measures used by the Developer are removed. In
confirmation that the site is stabilized by the City any remaining portions of the security
deposit shall be returned.
10. The drainage design for this Development provides for the evacuation of storm
drainage runoff in a reasonable amount of time out of the water quality and detention
facilities and into the drainage outfall system. The water quality and detention facilities have
been designed to discharge stormwater runoff from frequent storms over a 40-hour period
through a small diameter outlet. Under the intended operation of the water quality and
detention pond, there will not be standing water in the pond more than 48 hours after the end
of a rainfall event. If after construction and acceptance of the detention facilities associated
with this Development, surfacing or standing water conditions persist in these facilities; and
if such conditions are beyond what can be expected in accordance with the approved
stormwater design, the Developer shall promptly, upon such discovery, install an adequate
de -watering system in the detention facilities. Such a system shall be reviewed and approved
by the City prior to installation.
F. Subheading II (Special Conditions) Paragraphs D.2.a — 2.e shall be replaced in their
entirety with the following:
2.
a. In accordance with Section 24-95 of the City Code the Developer is responsible
for constructing the portion of Buckingham Street adjacent to the site prior to the
issuance of the first building permit. Notwithstanding the foregoing, the City and the
Developer had agreed to delay the construction of these improvements (Phase 2
Improvements) provided that a letter of credit was provided to the City to guarantee the
completion of these improvements. A non -expiring letter of credit for $631,574.00
(issuance date of December 23, 2011) was provided to and is being held by the City
available to cover the cost necessary to relocate or remove the John G. Coy Ditch ("Coy
Ditch") outside of Buckingham Street; and to design and construct the Buckingham
Street improvements, and the utility and storm drainage facilities made necessary by the
improvements to the Development; and any outstanding design and permitting costs
necessary to complete full approval needed in order to commence construction of Phase 2
improvements. This amount is further described and detailed on Exhibit "C".
b. The dates in which the Developer has to complete the design, obtain approval by
the owners of interest in the Coy Ditch and the City, and construct said Phase 2
improvements as identified in Amendment Agreement No. 3 have passed and shall be
extended as identified below. The City has purchased an undivided 50% interest in the
water right decreed to the Coy Ditch by the Larimer County District Court in Civil
Action 320, decree dated April 11, 1882, with an appropriation date of April 10, 1865
("Coy Ditch Water Right"). East Larimer County Water District (" BLCO") claims
ownership of the other 50% of the Coy Ditch Water Right. The City has no plans to
4
transmit water within the Coy Ditch on the Property and is working with the Developer
and ELCO regarding the abandonment and/ or removal of the ditch on the Property.
C. The Developer shall have until December 31, 2015 to complete the design, obtain
approval by the City, and construct said Phase 2 improvements.
d. Should the Developer be unable to complete the Phase 2 Improvements by
December 31, 2015 the City reserves the right to call the letter of credit on file with the
City in order to have the improvements constructed.
e. If the City calls the letter of credit, the improvements may then be constructed by
the City or a third party utilizing the proceeds of the letter of credit. If the Phase 2
Improvements are constructed by the City or a third party, neither the City nor the third
party shall be bound to complete the Phase 2 improvements by December 31, 2015.
G. Subheading II (Special Conditions) Paragraph E shall be replaced in its entirety with the
following:
E. Natural Resources
1. The Developer agrees that, in order to comply with Section 3.4.1 of the Land Use
Code, it must establish at least 0.32 acres of upland habitat in order to mitigate the loss of
0.16 acres of wetlands located in the project site. To meet this requirement, the Developer
will provide the location on -site for the 2:1 wetland mitigation, a landscaping plan, an
itemized budget, and a project timeline.
2. The Developer shall ensure that all landscaping with the 0.32 acres of upland
habitat is properly maintained for a three (3) year period following construction thereof to
ensure that the vegetation is fully established and has met the success criteria. The mitigation
will be considered successful when:
a. 0.32 acres of upland have been created and enhanced
b. 80% of planted trees and shrubs are alive after three years
c. It is dominated by desirable plant species
d. It has a vegetation cover of at least 80% as determined by methods in number
5 below.
e. No Colorado noxious weeds on List A maintained by the Colorado
Department of Agriculture are present
3. The status and effectiveness of the vegetation shall be evaluated and the results
reported to the City of Fort Collins Environmental Planner, Current Planning Department
semi-annually for review. The first report each year shall include an update on weed
management, planting and seeding schedules, and other site -specific conditions, and the
second report shall include an overview of vegetative cover and composition, tree and shrub
establishment, and other specific management issues or concerns. The first report is due
between March 1 and June 1 of each year and the second report is due between October 1
and December 31 of each year.
4. The Developer shall provide to the City prior to the issuance of any Certificate of
Occupancy an acceptable form of security (cash, letter of credit, etc.) to guarantee
completion of the upland habitat landscape improvements. The Developer shall submit an
estimate for such improvements for review and approval by the City. Said estimates of
landscape improvements shall constitute plant material, labor costs, and irrigation system
improvements. The required security shall be in an amount equal to 75% of the total amount
of the approved estimate to be held until said landscape improvements are constructed,
established, and accepted by the City. The City shall return the security to the Developer
upon the Developer's installation of the landscape improvements and the City's acceptance
thereof. If the upland habitat has not been established in accordance with the Final
Development Plan Documents after the third year of monitoring, then the Developer shall
promptly take such steps as are necessary with a written proposal of plans and timing to bring
the upland habitat into conformance with the approved plans. If the Developer does not take
action to bring the upland into conformance with the approved plans, the City shall use the
security provided by the Developer to install said plans and improvements and the Developer
forfeits any right to the security.
5. The areas of the Development that are planned to be seeded, shall be inspected
jointly by the Developer and the City at least once per year for three (3) growing seasons or
until determined by the City to be well established in accordance with the coverage
specifications of this paragraph, whichever occurs first. Areas seeded in the Spring shall be
inspected for required coverage each immediately subsequent Autumn not later than October
1 st. Areas seeded at any other time shall be inspected each immediately subsequent summer
not later than August 1st. The required coverage for the first inspection shall be ten (10)
viable live seedlings of the specified species per one square foot, or fifty percent (50%)
coverage of the specified foliage as measured from five feet (5') directly overhead, with no
bare spots larger than 1 square foot. At the time of the second growing season inspection,
there shall be seventy-five percent (75%) foliage cover of the specified species planted as
measured from five feet (5') directly overhead, and no bare spots large than one-half a square
foot. No more than ten percent (10%) of the species noted on the site may be weed species
as defined by Chapter 20, Article IV, Section 20-41 of the Code of the City. The Developer
shall be responsible for weed and erosion control at all times. Determination of required
coverage will be visual assessments and as needed, based on random transects each ten
meters in length, randomly placed in representative portions of the seeded areas, with plant
species or bare ground/rock/litter being noted every ten (10) centimeters along each transect.
The Developer shall rework and reseed per original specifications any areas that are dead,
diseased, contain too many weedy species, or fail to meet the coverage requirement at no
additional cost to the City.
6. Fueling facilities shall be located at least one hundred (100) feet from natural
body of water, wetland, natural drainage way or manmade drainage way. The fuel tanks and
fueling area must be set in a containment area that will not allow a fuel spill to directly flow,
seep, run off, or be washed into a body of water, wetland or drainage way.
G
Comment Number: 4. Comment Originated: 10/21/2015
t 10/21/2015: On Sheet LP 100, the Overall Planting Plan does not indicate which
trees are the mitigation trees.
- There are no trees to be mitigated. 1-13101 sheet title has been changed to "Tree Protection
and Removal Plan".
Comment Number: 5. Comment Originated: 10/21/2015
10/21/2015: For the re -submittal, all I need are sheets L 100 and L 101. Or, an
electronic review would suffice as long as there is a detailed narrative or phonecall
that responds to the comments.
- Noted.
Department: Engineering Development Review
Contact: Sheri Langenberger, 970-221-6573, yJanLganbefAprM_aov--om
Topic: General
Page 2 of 4
7. The Developer shall delineate the Development's property boundary adjacent to
all Limits of Development as defined by Article V, Section 5.1.2 of the Land Use Code,
including the upland habitat mitigation area and the boundaries around existing trees that are
to be undisturbed with orange construction fence prior to any type of construction, including
overlot grading.
H. All other terms and conditions of the Development Agreement (as amended by
Amendment Agreement No. 1, Amendment Agreement No. 2, and Amendment Agreement
No. 3) shall remain unchanged and in full force and effect, except as expressly amended in
this Amendment Agreement No. 4.
IN WITNESS WHEREOF, the parties hereto have executed this Fourth Amendment the
day and year first above written.
ATTEST:
CITY CLERK
APPROVED AS TO CONTENT:
City Engineer
APPROVED AS TO FORM:
Deputy City Attorney
THE CITY OF FORT COLLINS, COLORADO,
a Municipal Corporation
By:
Darin Atteberry, City Manager
7
DEVELOPER:
NEW BELGIUM BREWING COMPANY, INC., a
Colorado Corporation
By:
Christine Perich, Chief Executive Officer
ATTEST:
Danielle McLarnon, Chief Financial Officer
STATE OF COLORADO )
) ss.
COUNTY OF LARIMER )
The foregoing instrument was acknowledged before me this day of
2014, by NEW BELGIUM BREWING COMPANY, INC. by Christine Perich as Chief
Executive Officer and by Danielle McLarnon as Chief Financial Officer.
Notary Public
My Commission Expires:
MA150091 New Belgium - liquid center expansion October 20, 2015
Engineering Comments
Standard note #19 is missing from the General notes.
Based on the submitted drawings a DCP will not be needed (DCP determination is based on the value of
the public infrastructure improvements), but an excavation permit along with the street cut fee will
need to be obtained prior to installation of the sewer service and issuance of the building permit.
Utility plan mylars and any amendment to the DA (if needed) will need to be completed before the
minor amendment can be approved.
-L Farnsworth
GROUP
October 26, 2015
City of Fort Collins
Community Development and Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
1612 Specht Point Road, Suite 105
Fort Collins, CO 80525
p 970.484.7477 f 970.484.7488
www.f-w.com I www.greennavigation.com
RE: New Belgium Brewery Liquid Center Expansion, MA150091, Round 1 Comment Reply
To City staff:
Please review our responses (in blue) to the City provided comments for the New Belgium Brewery Liquid
Center Expansion first submittal.
Department: Engineering Development Review
Contact: Sheri Langenberger, 970-221-6573, slangenberger@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 10/20/2015
10/20/2015: Standard note #19 is missing from the General notes. Standard Note #19 has been
added to the General Notes.
Comment Number: 2 Comment Originated: 10/20/2015
10/20/2015: Based on the submitted drawings a DCP will not be needed (DCP determination is
based on the value of the public infrastructure improvements), but an excavation permit along with
the street cut fee will need to be obtained prior to installation of the sewer service and issuance of
the building permit. Noted.
Comment Number: 3 Comment Originated: 10/20/2015
10/20/2015: Utility plan mylars and any amendment to the DA (if needed) will need to be completed
before the minor amendment can be approved. Noted.
Department: Stormwater Engineering
Contact: Dan Mogen, dmogen@fcgov.com
Topic: Construction Drawings
Comment Number: 4 Comment Originated: 10/27/2015
10/27/2015: It appears there are conflicting notes on sheets C4 & C7 regarding the area inlets in
the area around the rolle bolle game. Please clarify inlet capping and replacing with pedestrian inlet
grates. The notes have been changed for clarity. The inlet changes identified on the plans are
correct.
Comment Number: 5
10/27/2015: A "subdrain detail" is referenced in note 2 on sheets C7 & C8; however, this detail
cannot be found on sheet CD1 as stated. "D1" has been added to the note and detail to improve
clarity. The note references the "Subdrain Detail", within detail D1, on sheet CD1.
ENGINEERS I ARCHITECTS I SURVEYORS I SCIENTISTS
Comment Number: 6
10/27/2015: Please add the finished floor elevation for the addition to the grading plan, sheet C6.
Finished floor elevations have been added to the grading plan.
Comment Number: 7
10/27/2015: Sheet C9.1 shows the storm water pipes to remain at 86' while the drainage report
has indicated upsizing is required in some areas. Please review and update. The storm sewer has
been increased to 12" on the plans.
Topic: Drainage Report
Comment Number: 3
10/27/2015: The net decrease in impervious area is noted to be 496sf. Please update the table in
Appendix B to clarify the change in impervious area and what is shown in the table. The table has
been color coded to clarify the changes in impervious area to the corresponding project.
Contact: Jesse Schlam, 970-218-2932, jschlam@fcgov.com
Topic: Erosion Control
Comment Number: 1 Comment Originated: 10/13/2015
10/13/2015: The site disturbs more than 10,000 sq-ft, therefore Erosion and Sediment Control
Materials need to be submitted for FDP. The erosion control requirements are in the Stormwater
Design Criteria under the Amendments of Volume 3 Chapter 7 Section 1.3.3. Current Erosion
Control Materials Submitted do not meet requirements. Please submit; Erosion Control Plan (Has a
minor redline to be addressed please see returned material), Erosion Control Report (I am ok with a
letter outlining the changes from MA150059 office expansion/Beer Garden's Report as it is the
same material just slightly amended with reguards to the location), and an Escrow / Security
Calculation. If you need clarification concerning the erosion control section, or if there are any
questions please contact Jesse Schlam 970-218-2932 or email @ jschlam@fcgov.com. A full
erosion control plan for the LC has been completed and provided as part of the final drainage
report.
Department: Technical Services
Contact: Jeff County, 970-221-6588, jcountv(cr-fcaov.com
Topic: Building Elevations
Comment Number: 1 Comment Originated: 10/21/2015
10/21/2015: There are line over text issues. See redlines. Line over text issues have been resolved.
Topic: Construction Drawings
Comment Number: 3 Comment Originated: 10/21/2015
10/21/2015: There are line over text issues. See redlines. Line over text issues have been resolved.
If you have any questions or concerns regarding these responses, please contact me at 970-484-
7477 or sturner@f-w.com.
Sincerely,
Scott Turner
ENGINEERS I ARCHITECTS I SURVEYORS I SCIENTISTS
Comment Number: 1 Comment Originated: 10/20/2015
?' 10/20/2015: Standard note #19 is missing from the General notes.
-Standard Note #19 has been added to the General Notes.
Comment Number: 2 Comment Originated: 10/20/2015
10/20/2015: Based on the submitted drawings a DCP will not be needed (DCP
determination is based on the value of the public infrastructure improvements), but
an excavation permit along with the street cut fee will need to be obtained prior to
installation of the sewer service and issuance of the building permit.
-Noted.
Comment Number: 3 Comment Originated: 10/20/2015
10/20/2015: Utility plan mylars and any amendment to the DA (if needed) will need
to be completed before the minor amendment can be approved.
-Noted.
Department: Environmental Planning
Contact: Kelly Kimple, , imnle0fcgov.co_m
Topic: General
Comment Number:
Comment Originated: 10/22/2015
10/22/2015: Mark Fischer, Angela Milewski, Rick Bachand, Jennifer Roberts, and
Kelly Kimple met on Wednesday, August 26th to discuss 0.16 acres of wetland
mitigation required for the office expansion and improvements along Buckingham. At
this meeting, we had discussed having NBB take the next steps to draft a plan for
mitigation of the 0.16 acres of wetland, on -site, with at least a 2:1 ratio of upland
habitat to include fruit -bearing trees and shrubs, as well as flowering plants. Once
drafted, we talked about then reviewing the landscaping plan and budget to see how
we could tie the design into Nature in the City and/or an Audubon Habitat Hero
garden.
- This has been settled in the New Belgium Office and Beer Garden Expansion Minor
Amendment. Attached are the associated documents.
Comment Number: 2
Comment Originated: 10/22/2015
10/22/2015: Environmental planning will need to receive the mitigation proposal for
the 0.16 acres of wetlands onsite, as mitigation and monitoring plans are included
with final plans and are the basis for comparison with the development agreement
requirements.
- This has been settled in the New Belgium Office and Beer Garden Expansion Minor
Amendment. Attached are the associated documents.
Department: PFA
Contact: Jim Lynxwiler, 970-416-2869, jjynx_�.po�dre-fire.orn
Topic: General
Comment Number: 1
Comment Originated: 10/23/2015
10/23/2015: PATH OF EGRESS
The proposed pergola on the north side of the planned addition appears to cover the
path of egress. Options are to construct the arbor of non-combustible materials
along the path of egress, sprinkle a wood arbor along the path of egress, or remove
the arbor along the path of egress.
-Noted.
Comment Number: 2
10/23/2015: EXIT GATE
Comment Originated: 10/23/2015
Page 3 of 4
- Since the building's construction type is Type VB - we propose the pergola
structure to remain constructed out of wood to match the balance of the structural
system. To address the egress path protection, we propose the trellis be
constructed of fire retardant treated lumber.
Comment Number: 2 Comment Originated: 10/23/2015
10/23/2015: EXIT GATE
The man -gate exiting from the outdoor area is shown as swinging in. If the occupant
load is to exceed 49 persons, the gate will be required to swing out and be equipped
with appropriate exithardware.
-The gate has been updated on the site and landscape plans.
Comment Number: 3 Comment Originated: 10/23/2015
10/23/2015: FIRE PITS
Fire pits fueled by natural gas are allowed. Wood burning or smoke producing fire
pits are prohibited. The plans indicate no wood products are planned on being
burned.
-Noted.
Page 4 of 4
Department: Stormwater Engineering
Contact: Dan Mogen, , dnignp S,gov_ c_
Topic: Construction Drawings
Comment Originated: 10/27/2015
Comment Number: 4
10/27/2015: It appears there are conflicting notes on sheets C4 & C7 regarding the
area inlets in the area around the rolle bolle game. Please clarify inlet capping and
replacing with pedestrian inletgrates.
-The notes have been changed for clarity. The inlet changes identified on the plans are
correct.
Comment Number: 5 Comment Originated: 10/27/2015
10/27/2015: A "subdrain detail" is referenced in note 2 on sheets C7 & C8; however,
this detail cannot be found on sheet CD1 as stated.
-"D1" has been added to the note and detail to improve clarity. The note references
the "Subdrain Detail", within detail D1, on sheet CD1.
Comment Number: 6
Comment Originated: 10/27/2015
10/27/2015: Please add the finished floor elevation for the addition to the grading
plan, sheet C6.
-Finished floor elevations have been added to the grading plan.
Comment Number: 7 Comment Originated: 10/27/2015
10/27/2015: Sheet C9.1 shows the storm water pipes to remain at 86" while the
drainage report has indicated upsizing is required in some areas. Please review
and update.
-The storm sewer has been increased to 12" on the plans.
Topic: Drainage Report
Comment Number: 3
Comment Originated: 10/27/2015
10/27/2015: The net decrease in impervious area is noted to be 496sf. Please
update the table in Appendix B to clarify the change in impervious area and what is
shown in the table.
-The table has been color coded to clarify the changes in impervious area to the
corresponding project.
Topic: Landscape Plans
Comment Number: 2
Comment Originated: 10/27/2015
10/27/2015: Please expand Landscape Note 1 on LP001 to include separation
requirements. No trees shall be planted with 10' of water and sewer mains or within
6' of service lines. No shrubs shall be planted within 4' of water and sewer mains or
service lines.
- The plans have been updated.
Contact: Jesse Schlam, 970-218-2932, jggh1amQgov_
Topic: Erosion Control
Comment Number: 1
Comment Originated: 10/13/2015
10/13/2015: The site disturbs more than 10,000 sq-ft, therefore Erosion and
Sediment Control Materials need to be submitted for FDP. The erosion control
requirements are in the Stormwater Design Criteria under the Amendments of
Volume 3 Chapter 7 Section 1.3.3. Current Erosion Control Materials Submitted do
not meet requirements. Please submit; Erosion Control Plan (Has a minor redline to
be addressed please see returned material), Erosion Control Report (I am ok with a
letter outlining the changes from MA150059 office expansion/Beer Garden's Report
as it is the same material just slightly amended with reguards to the location), and
Page 5 of 4
an Escrow / Security Calculation. If you need clarification concerning the erosion
control section, or if there are any questions please contact Jesse Schlam
970-218-2932 or email @ jschlam@fcgov.com
-A full erosion control plan for the LC has been completed and provided as part of the
final drainage report.
Department: Technical Services
Contact: Jeff County, 970-221-6688, j�o� tvCa�f-aov.com
Topic: Building Elevations
Comment Originated: 10/21/2015
Comment Number: 1
10/21 /2015: There are line over text issues. See redlines.
- The plans have been updated.
Page 6 of 4
Comment Number: 2 Comment Originated: 10/21/2015
10/21/2015: There are text over text issues. See redlines.
-The plans have been updated.
Topic: Construction Drawings
Comment Number: 3 Comment Originated: 10/21/2015
10/21/2015: There are line over text issues. See redlines.
-The plans have been updated.
Topic: Landscape Plans
Comment Number: 4 Comment Originated: 10/21/2015
10/21/2015: No comments.
-Noted.
Topic: Site Plan
Comment Number: 5 Comment Originated: 10/21/2015
10/21/2015: Please make changes to the legal description as marked. See redlines.
- The plans have been updated.
Comment Number: 6 Comment Originated: 10/21/2015
10/21/2015: The titles in the sheet index do not match the titles on the noted sheets.
Please make changes as marked. See redlines.
- The plans have been updated.
Comment Number: 7 Comment Originated: 10/21/2015
10/21/2015: Please tie the coordinate values shown to the project boundary. We
would prefer that this be done by adding property corner values to each sheet, or
showing the property corner values on a horizontal control plan and adding a noteto
each sheet with coordinate values.
- The plans have been updated.
Comment Number: 8 Comment Originated: 10/21/2015
10/21/2015: There are line over text issues. See redlines.
- The plans have been updated.
Page 7 of 4
EXHIBIT E
STANDARD OPERATING PROCEDURES (SOPS)
A. Purpose
In order for physical stormwater Best Management Practices (BMPs) to be effective, proper maintenance is
essential. Maintenance includes both routinely scheduled activities, as well as non -routine repairs that may be
required after large storms, or as a result of other unforeseen problems. Standard Operating Procedures
(SOPS) should clearly identify BMP maintenance responsibility. BMP maintenance is typically the responsibility
of the entity owning the BMP.
Identifying who is responsible for maintenance of BMPs and ensuring that an adequate budget is allocated for
maintenance is critical to the long-term success of BMPs. Maintenance responsibility may be assigned either
publicly or privately. For this project, the privately owned BMPs shown in Section B below are to be maintained
by the property owner, Homeowners Association (HOA), or property manager.
B. Site-Spedflc SOPS
The following stormwater facilities contained within this development are subject to SOP requirements:
- Directly Connected Downspouts
- Perforated Subdrain
- Storm Drain Lines
- Dry Extended Detention
- Bioswale
- Bioretention
The location of said facilities can be found on the Utility Plans and Landscape Plans. Inspection and
maintenance procedures and frequencies, specific maintenance requirements and activities, as well as BMP-
specific constraints and considerations shall follow the guidelines outlined in Volume 3 of the Urban Drainage
and Flood Control District (UDFCD) Urban Storm Drainage Criteria Manual.
SOP Maintenance Summary Table
Stormwater Facility /
BMP
Ownership /
Responsibility
UDFCD Maintenance Reference
Directly Connected
Downspouts
Private
Follow guidelines for Roof Gutters and Downspouts
Perforated Subdrain
Private
Follow applicable guidelines for Perforated Subdrain
Storm Drain Lines
Private
Follow guidelines for Storm Drains and Tree Roots
Dry Extended Detention
Private
Follow guidelines for Extended Detention Basins
Bioswale
Private
Follow guidelines for Bioretention
Bioretention Private Follow guidelines for Bioretention
The complete UDFCD BMP maintenance references listed above, except for the roof gutters and downspouts,
can be found in Chapter 6 of Volume 3. Applicable BMP maintenance excerpts can be found at the end of this
document.
Directly Connected Downspouts
Many of the downspouts connect directly to the storm drain system. The following SOP generally applies to all direct
downspout connections, and more specifically to those which drain directly to the reservoir areas beneath the Modular
Block Pavers. At each of these connections, the downspout discharges to a perforated drain basin. The drain basins
discharge directly to the MBP reservoir. The drain basins are designed to prevent debris and sediment from entering
the MBP reservoir area. Debris and sediment compromise the functionality and effectiveness of the system.
Routine Maintenance Table for Directly Connected Downspouts