Loading...
HomeMy WebLinkAboutFORT COLLINS RETAIL CENTER PUD - Filed CS-COMMENT SHEETS - 2015-09-22AA - 0002921 January 14, 2015 To: City of Fort Collins 2324 Hampton Ave. St. Louis, MO 63139 Re: Mattress Firm (OA #14-120) 4312 S. College Ave. Fort Collins, CO 80525 Reference: Tracking No. MA140120 To Whom It May Concern: I am writing this letter in response to your Building Plan Review Comments for the above referenced project. Planning Services — Jason Holland 970-224-6126 (12/03/14) Comment 1: Existing trees on the site must remain and be protected in accordance with the land use code, and any pruning must be done according to city standards. Please remove the note Reference #3 on the site plan, and add the following notes to the site plan. CITY OF FORT COLLINS TREE PROTECTION NOTES: (1)WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR -INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. (2)ALL TREE PRUNING MUST BE PERFORMED BY A BUSINESS HOLDING A CURRENT ARBORIST LICENSE AND ALL PRUNING MUST BE IN ACCORDANCE WITH THE CITY OF FORT COLLINS FORESTRY STANDARDS. (3)PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANCE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE- HALF (1/2) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. (4)DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. (5)NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. Response 1: Note #3 has been removed as requested and the above notes have been added to the Site Plan, Drawing AS1 as requested. Page 1 of 5 32707 US Hwy. 19 - Palm Harbor, FL 34684 - Phone 727 - 781 - 7525 - Fax 727 - 781 - 6623 - E-mail info@oliveriarchitects.com - www.oliveriarchitects.com - Comment 2: 1) LIGHTING: FIXTURE ILLUMINATION LEVELS PROVED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND WITH CITY OF FOR COLLINS LIGHT AND POWER UTILITY REQUIREMENTS. ALL LIGHTING FIXTURES PROVIDED WITH THE PROJECT SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE AND SHALL FEATURE SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP -LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 2)SIGNAGE IS NOT PERMITTED WITH THESE FINAL PLANS AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. Response 2: The above notes have been added to the Site Plan, Drawing AS1 as requested. Comment 3: At least one of the accessible parking spaces provided must be van accessible, with a Minimum 8' wide stall adjoining a minimum 8' wide striped access isle, with the isle Located on the passenger side where car doors are typically located. Response 3: A van accessible space has been designated on the Site Plan, Drawing AS1 as requested. Encmeerinp Development Review — Marc Ranasa 970-221-6603 (12/031141 Comment 1: 1. Please add the standard sidewalk repair note to the site plan: "Any damaged curb, gutter and sidewalk existing prior to construction, as well as Streets, sidewalks, curbs and gutters, destroyed, damaged, or removed due to Construction of this project, shall be replaced or restored to City of Fort Collins Standards at the developer's expense prior to the acceptance of completed Improvements and/or prior to the issuance of the first certificate of occupancy. Response 1: The above note has been added to the Site Plan, Drawing AS1 as requested. Comment 2: There are three tripping hazards that need to be repaired in the sidewalk along the Property frontage. These areas have been marked by our chief construction inspector. Please make the necessary repairs to the sidewalk prior to the issuance of the certificate of occupancy. An excavation permit will be required prior to starting these repairs. Response 2: The three existing tripping hazards at the sidewalk at the front of the property do not occur on our site plan extents. The contractor will confirm the location of these areas and be made aware that the repair of these areas will be required prior to issuance of the certificate of occupancy. Comment 3: A 120' x 12' section of right of way will need to be dedicated with this development. A Portion in the northwest corner of the parcel will need to be dedicated for the Implementation of the City of Fort Collins' Midtown Plan. Please see a ling to the plan Detailing the location of the future sidewalk (Sheet 2): http:www.fcgov.com/planning/pdf/appendix_a_10_perecent_plansheets.pdf Please call to discuss exact location that needs to be dedicated. Page 2 of 5 Response 3: The dedicated right of way for this development is outside of our scope and will be coordinated and resolved by the landlord of the property. Stormwater Enuineerina — Glen Schlueter, 970-224-6065 (12/02/14) Topic: Floodplain Comment 2: This site is not in a jurisdictional floodplain. No floodplain requirements apply. Response 2: N/A Topic: General Comment 3: Documentation of new impervious area is needed. Keyed notes 15,21, 22 on sheet AS1 indicate new concrete. Please provide written documentation of the total new Impervious area. If it is less than 100 square feet all that is needed is a grading plan For the new concrete. That information could be added to sheet AS1 by showing the elevation of the finished floor as 100 or zero. Only sheet AS1 is needed to a resubmittal Or whichever sheet will show the grading. Response 3: The new concrete being added as part of this project scope is less than 100 SF. The slab floor elevations have been added to the walk and ramp details on Drawing AS1, as requested. Comment 4: Water quality treatment of the site runoff is required to the maximum extent practicable When there is a change of use. Please contact Basil Harridan at 224-6035 to work out the details. As a suggestion disconnection of impervious area is one method so if the Downspouts can drain into a landscape area or planter boxes that would qualify as water quality treatment. Since there is no work proposed in the parking lot installation of porous pavers will not be required as long as some water quality treatment is provided. Response 4: The existing roof currently drains into two downspouts at the rear of the building. One currently drains into a landscape area while the other that is located adjacent to the dumpster enclosure spills onto the existing concrete walk. A portion of this walk will be saw cut and removed to create a new landscape area to allow water to permeate into the ground, as suggested above. See Site Plan, AS1, Demolition Plan, D1 and the Floor Plan, Ala. Comment 5: This is just a heads up in case any improvements are ever considered in the parking Lot. The parking lots in the Fort Collins Retail Center PUD have depression areas with Inlets that serve as the runoff detention. So any modifications to it would have to maintain The detention volume provided. Response 5: Improvements to the existing parking lot are not a part of this project scope. Page 3 of 5 Jesse Schlam - 970-218-2932, (12/02114) Topic: Erosion Control Comment 1: No comment from Erosion Control. This Site, disturbs less than 10,000 sq-ft; is not In a sensitive area, and is not in a larger development under construction. Therefore, No submittal of erosion control material in needed. However, the site still must be swept And maintained to prevent dirt, saw cuttings, concrete wash, and other pollutants from Entering the storm sewer at all times or BMPs will be required of the site. If you need clarification concerning this, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @ ischlamCaD-fcgov.com Response 1: The future tenant will be notified of this requirement and the site will be maintained as outlined above. Technical Service — Jeff County, 970-221-6588 (12104/14) Topic: Building Elevations Comment 1: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Response 1: The construction drawings submitted for permit are prepared with a high degree of professionalism, are clearly legible and follow standard architectural drafting protocol. Several details included in this set of construction documents have been extracted directly from the building code and are drawn in the same manner. Code compliant issues have been addressed with the attached revisions. Comment 2: There are line over text issues. See redlines. Response 2: See response #1 above. Topic: General Comment 3: Floor Plan: There are line over text issues. See redlines. Response 3: See response #1 above. Comment 4: Floor Plan: There is text that needs to be masked. Mask all text in hatched areas. Response 4: See response #1 above. Page 4 of 5 a< - Topic: Site Plan Comment 5: Please add a legal description for the project property. Response 5: The legal description for the property has been added to the Site Plan, Drawing AS1, as requested. Comment 6: There are line over text issues. See Redlines. Response 6: See response #1 above Comment 7: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Response 7: See response #1 above Zoning — Ali Van Deutekom, 970-416-2743, (12/09/14) Topic: General Comment 1: The retail use requires a minimum of 4 bicycle parking space. One of these spaces would need to be enclosed. Response 1: Per our telephone conversation on 1113/15, there are currently four bicycle parking spaces at the front of the building North of the front entry doors. To satisfy the requirement for one enclosed space, we have designated a six (6) square foot area within the Files/ Records Rm. #103 adjacent to the rear door #103b. See the Site Plan, AS1 and the Floor Plan, Ala. Should you have any questions or concerns, please do not hesitate to contact me. ...._..L_ I . 2-Ai S EPH L. ; Joseph L. iveri, AIA, 4RB OUVERI President Stdt o ra o License No. ARC 004Q3 ' JLO/mh Page 5 of 5