HomeMy WebLinkAboutBUCKING HORSE FILING TWO - Filed E-ELEVATION PLAN - 2013-01-14ti
m
t-
-
1 � ,.r -. -� .� _-. �:: 2 _ _ ,-. ,Fr -.. �« - F�*I .k`' ,..,F a.s,-_ -_- - - __ — m:" �•='tl.... .mow=.,•..�y,_'a.,a.e..;_, r. _-
------- 77U�
IF
TIII III III III III
- III1-IIIIII1 _ IIIIII1111-III IIIIIIIIIIIIIII11III1-III
ii=lii iii iii iii ii i..i iii-jam_ =ili iii �.�i ii.I ii iii li.i iil ili iii i,ii iii---iii lik
BARN -NORTH ELEVATION - EXISTING n BARN - EAST ELEVATION - EXISTING n BARN - SOUTH ELEVATION - EXISTING BARN - WEST ELEVATION - EXISTING
�`J " _ " - U 3/32" = 1'-0" �'J 3/32"
3/32" = 1'-0" 3/32 - 1-0
BARN - NORTH ELEVATION - PROPOSED
5 3/32" = V-0"
-------------
10 VIEW -FROM NW
BARN - EAST ELEVATION - PROPOSED
3/32" = V-0"
BARN - SOUTH ELEVATION - PROPOSED
3/32" = V-0"
III���III���IIII��
n BARN - WEST ELEVATION - PROPOSED
3/32" = V-W
KEYNOTES
HATE
DESCRIPTION
Al
(E) WD. FRAME WINDOW TO BE REHABILITATED OR REPLACED W/ IN -KIND MATERIALS TO MATCH (E), PAINT
A2
(E) DOOR AND HARDWARE TO BE REHABILITATED OR REPLACED W/ IN -KIND MATERIALS AND FIXED IN OPEN POSITION, PAINT. OPENING TO BE INFILLED W/ ALUM. STOREFRONT SYSTEM
A4
(E) SIDING AND WINDOW TRIM TO REMAIN, BROKEN/ MISSING PIECES TO BE REPLACED W/ IN -KIND MATERIAL, PAINT
A5
(E) TAPER -SAWN SHINGLE ROOFING TO BE REMOVED, ORIGINAL SKIP SHEATHING TO REMAIN BROKEN/ MISSING PIECES TO BE REPLACED W/ IN -KIND MATERIAL. INSTALL NEW 1 /2" PLYWOOD, BREATHABLE
UNDERLAYMENT AND NEW TAPER -SAWN SHINGLE ROOFING OR WEATHERED WOOD ARCHITECTURAL SHINGLE
A6
NEW ALUMINUM CLAD DIVIDED LIGHT WD. WINDOW W DBL. INSULATED GLAZING IN NEW OPENING
A7
(E) HOIST BEAM AND HARDWARD TO BE REHABILITATED, PAINT
A8
NEW ALUMINUM CLAD DIVIDED LIGHT WD. WINDOW W DBL. INSULATED GLAZING IN ORIGINAL OPENING
A9
(E) DOOR AND HARDWARE TO BE REHABILITATED OR REPLACED W/ IN -KIND MATERIALS, PAINT
A10
(E) WD. LOUVERS AND HARDWARE TO BE REHABILITATED OR REPLACED W/ IN -KIND MATERIALS, PAINT
A13
(E) EXPOSED RAFTER TAILS TO BE REHABILITATED OR REPLACED WITH IN -KIND MATERIAL, PAINT
A16
NEW ALUM CLAD WD. DIVIDED LIGHT DBL. GLAZED WINDOW TO BE PLACED IN NEW OPENING
A17
NEW ALUM CLAD FULL GLASS WOOD DOOR W/ DIVIDED LITES
A23
(E) C.I.P CONCRETE FOUNDATION TO BE PAINTED
A25
(E) GRAIN SHUTE AND HARDWARE TO BE REHABILITATED OR REPLACED W/ IN -KIND MATERIAL
A26
NEW WD. DECK AND RAILING W/ ANGLED WD. SUPPORT BRACKETS, PAINT
11I11I11I1-III III III
--------------
_ _
- - - u-Irlr-w-�-ZU-Ib- _,_ _ _
u 1]— —
-------- -
11Iw = _
NUII
9 VIEW - FROM SE
O
130
c!) w
Z~
J O
_p J
LL(L O
WW Vi
O .,
C!) (a) c�
z'
0 J
OJ
M20
—v
v)
J
ZJ oc!
_w O
elm u.
V
D
m
ALLER • LINGLE • MASSEY
ARCHITECTS
P.C.
712 WHALERS WAY SUITE, B-100
FORT COLLINS, CO 80525
(970)223-1820
www.aller-lingle-massey.com
OFFICE BLDG. 1
0
N
W PROJECT 1140
y DATE 12/11/12
Q
� DRAWN MDN
J
z
_J FDP1
a
O
E-97 2651
Ln
•o
h!
ORIGINAL HOUSE - NORTH ELEVATION
EXISTING
3/16" = V-0"
----------------- -
,
I_-+.....
- - -
_______________
.._._........ ........---
-----------
VIEW - FROM SE
ORIGINAL HOUSE - EAST ELEVATION
EXISTING
3/16" = V-0"
ORIGINAL HOUSE - EAST ELEVATION
PROPOSED
3/16" = 1'-0"
ORIGINAL HOUSE - SOUTH ELEVATION
«EXISTING
3n s" = 1'-0"
ORIGINAL HOUSE - SOUTH ELEVATION
7 PROPOSED
3/16" = V-0"
KEYNOTES
NOTE DESCRIPTION
Al
(E) WD. FRAME WINDOW TO BE REHABILITATED OR REPLACED W/ IN -KIND MATERIALS TO MATCH (E), PAINT
A4
(E) SIDING AND WINDOW TRIM TO REMAIN, BROKEN/ MISSING PIECES TO BE REPLACED W/ IN -KIND MATERIAL, PAINT
A8
NEW ALUMINUM CLAD DIVIDED LIGHT WD. WINDOW W DBL. INSULATED GLAZING IN ORIGINAL OPENING
A9
(E) DOOR AND HARDWARE TO BE REHABILITATED OR REPLACED W/ IN -KIND MATERIALS, PAINT
A13
(E) EXPOSED RAFTER TAILS TO BE REHABILITATED OR REPLACED WITH IN -KIND MATERIAL, PAINT
A21
NEW ALUM. CLAD WD DOOR W/ HALF LITE
A23
(E) C.I.P CONCRETE FOUNDATION TO BE PAINTED
A27
(E) TAPER -SAWN SHINGLE ROOFING TO BE REMOVED, ORIGINAL SKIP SHEATHING TO REMAIN BROKEN/ MISSING PIECES TO BE REPLACED.
INSTALL NEW 1/2" PLYWOOD, ROOFING FELT AND NEW TAPER -SAWN SHINGLE ROOFING
A28
NEW 6'-0" X 10'-0" PATIO/ ROOF. 2X10 WD. ROOF BEAMS SUPPORTED BY 6X6 WD COLUMNS W/ 2X6 WD RAFTERS, 1/2" PLYWOOD, ROOFING
FELT AND NEW TAPER -SAWN SHINGLE ROOFING. 2X2 WD RAILING. ALL EXPOSED STRUCTURE/ RAILING/ PLYWOOD TO BE PAINTED
ORIGINAL HOUSE - WEST ELEVATION
EXISTING
3/16" = V-0"
ORIGINAL HOUSE - WEST ELEVATION
PROPOSED
3/16" = V-0"
------- -- --
f.
C]
10 VIEW - FROM NW
0
w
fn
cn
J
0
z
J
w
J
J
a
ALLER • LINGLE • MASSEY
ARCHITECTS
P.C.
712 WHALERS WAY SUITE, B-100
FORT COLLINS, CO 80525
(970)223-1820
www.aller-lingle-massey.com
OFFICE BLDG. 2
PROJECT 1140
DATE 12JI1/12
DRAWN MDN
FDP2
J \'7/I
@- 97
2651
a
N
MAIN HOUSE - NORTH ELEVATION
EXISTING
1/8" = 1'-0"
MAIN HOUSE - EAST ELEVATION
1�1 1X18T=ING
�1/V" 1'-0
w
MAIN HOUSE - SOUTH ELEVATION
EXISTING
1/8" = 1'-0"
MAIN HOUSE - WEST ELEVATION
EXISTING
MAIN HOUSE - NORTH ELEVATION
MAIN HOUSE - EAST ELEVATION
MAIN HOUSE - SOUTH ELEVATION
MAIN HOUSE - WEST ELEVATION
PROPOSED
6 PROPOSED
PROPOSED
8 PROPOSED
5 1 /8" = 1'-0"
1 /8 = 1 -0
7 1 /8" = 1'-0"
1 /8 = 1-0
- 1m
9 VIEW - FROM SE
KEYNOTES
NOTE DESCRIPTION
A4
(E) SIDING AND WINDOW TRIM TO REMAIN, BROKEN/ MISSING PIECES TO BE REPLACED W/ IN -KIND MATERIAL, PAINT
A5
(E) TAPER -SAWN SHINGLE ROOFING TO BE REMOVED, ORIGINAL SKIP SHEATHING TO REMAIN BROKEN/ MISSING PIECES TO BE REPLACED W/
IN -KIND MATERIAL. INSTALL NEW 1/2" PLYWOOD, BREATHABLE UNDERLAYMENT AND NEW TAPER -SAWN SHINGLE ROOFING OR WEATHERED
WOOD ARCHITECTURAL SHINGLE
A6
NEW ALUMINUM CLAD DIVIDED LIGHT WD. WINDOW W DBL. INSULATED GLAZING IN NEW OPENING
A8
NEW ALUMINUM CLAD DIVIDED LIGHT WD. WINDOW W DBL. INSULATED GLAZING IN ORIGINAL OPENING
A17
NEW ALUM CLAD FULL GLASS WOOD DOOR W/ DIVIDED LITES
A21
NEW ALUM. CLAD WD DOOR W/ HALF LITE
A27
(E) TAPER -SAWN SHINGLE ROOFING TO BE REMOVED, ORIGINAL SKIP SHEATHING TO REMAIN BROKEN/ MISSING PIECES TO BE REPLACED.
INSTALL NEW 1/2" PLYWOOD, ROOFING FELT AND NEW TAPER -SAWN SHINGLE ROOFING
A29
REMOVE EXISTING WALLS AND ROOF STRUCTURE. INSTALL HALF -WALLS OF WOOD FRAMING SHEATHED WITH PLYWOOD AND AIR BARRIER
AND LAP SIDING W/ WD. WALL CAP OVER (E) FOUNDATION. INSTALL NEW 8X8 WD. COLUMNS AND 2X10 BEAMS WRAPPED IN 1X WD. TO
SUPPORT ROOF TRUSSES
A30
REMOVE EXISTING ROOF STRUCTURE. REPLACE ROOF WITH PRE-ENGINEERED ROOF TRUSSES TO CREATE A HIPPED ROF SHEATHED WITH
1/2" PLYWOOD, ROOFING FELT AND NEW TAPER -SAWN SHINGLE ROOFING
A31
REMOVE EXISTING ROOF AND VERTICAL SIDING AND SHEATHING. INSTALL NEW 1/2" PLYWOOD SHEATHING, AIR BARRIER AND DROP SIDING
TO MATCH HOUSE ON (E) FOUNDATION. REPLACE WITH PRE-ENGINEERED ROOF TRUSSES TO CREATE A HIPPED ROOF. SHEATH WITH 1/2"
PLYWOOD, ROOFING FELT AND TAPER -SAWN SHINGLE ROOFING
A33
REMOVE EXISTING PORCH WALLS AND REPLACE WITH 6" WD. COLUMNS WRAPPED WITH 16" X 16" X 42" DROP SIDING ON WD.STUD BASE W/ 2X
WD. CAP AND 1X6 WD. BASE. 2X2 WD. RAILING BETWEEN COLUMNS, PAINT. NEW CAST -IN -PLACE CONCRETE SLAB FLOOR.
n VIEW -FROM NW
0
(DW p
JgO
Li a p
WWv
t!i v v�
�zz
00
Fm
N V
Z.j w
em LL
O
(a)
m
ALLER • LINGLE • MASSEY
ARCHITECTS
P.C.
712 WHALERS WAY SUITE, B-1DO
FORT COLLINS, CO 80525
(970)223-1820
www.aller-lingle-massey.com
OFFICE BLDG. 3
PROJECT 11Q
DATE 12/11/12
DRAWN MDN
FDP3
o
8-97 2651
STONE VENEER - BUFF
WEST ELEVATION
SCALE: 3/16" = V-0" RE: 1 / A2.1
FIBERGLASS WINDOWS - WHITE
CORRUGATED METAL
SIDING - RUST
CEMEENT FIBER TRIM -
PAINT WHITE
ARCHITECTURAL PROFILE ASPHALT
SHINGLE - WEATHERED WOOD
CEMENT FIBER FASCIA BOARD -
PAINT WHITE
STONE VENEER - BUFF
SOUTH ELEVATION
SCALE: 3/16" = V-0" RE: 1 / Al.l
12"
Q 3"
NORTH ELEVATION
SCALE: 3/16" = V-0" RE: 1 / A2.1
FIBERGLASS WINDOWS - WHITE
ARCHITECTURAL PROFILE ASPHALT
SHINGLE -WEATHERED WOOD
CEMENT FIBER FASCIA BOARD
PAINT WHITE
CORRUGATED METAL
rn SIDING -RUST
ZD
^' CEMENT FIBER TRIM -
PAINT W HITE
STONE VENEER - BUFF
EAST ELEVATION
SCALE: 3/16" = V-0" RE: 1 / A1.1
STONE VENEER - BUFF
NOTE: ALL GAS AND ELECTRICAL METERS TO BE PAINTED TO MATCH BUILDING
0
w .f .. Z
Im ... ELLISIM0 RhKINGwm HORSE� a
END -TO -END REAL ESTATE DEVELOPMENT S INVESTMENT
Q
Z .O
j V V
Z
LL _ cn
• Z
W Q --
cc � O
O _ V
IMM
= W
m 0
Z
Y
V
m
ALLER * LINGLE. MASSEY
ARCHITECTS
P.C.
712 WHALERS WAY SUITE, B-100
FORT COLLINS, CO 80525
(970)223-1820
www.aller-lingle-massey.com
BUILDING ELEVATIONS
PROJECT
1217
DATE
12/11/12
DRAWN
CAK
ol_
B - 9 7
2651
F
F