HomeMy WebLinkAboutRIGDEN FARM ELEVENTH BROOKLYN PARK ROW HOUSES - Filed CS-COMMENT SHEETS - 2008-12-19R®
PROJECT
Citv of Fort Collins
COMMENT SHEET
Current Planning
DATE: April 6, 2005 TO: Technical Services
PROJECT: #56-98AD Rigden Farm 13th Filing, Brooklyn Park
Row Houses PDP, Type I
All comments must be received by Steve Olt no later than the staff
review meeting:
April 27, 2005
Note - Please identify your redlines for future reference
❑ No Problems
5Problems or Concerns (see below or attached)
/, f ",j1p,+kV C/-o5c5, GC-6AL I761E5 NOT /'[o,5E� Go ES n/ot /V/ Trc / 3",v i*� ",
LT Ta� 77e—rx--e/Y/iir��
A ze�-
/�'aTrr,n,c �c.s�. • _ ,c5o �� . ^ ���->S -\A `-{ �-�1=5 r�� -sf N��)
3 /✓tea Yd r<No J vt/�1A 7-Zac7— q L S-
s! ar —
s.
Name (please print)
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
=Piat _Site _Drainage Report _Other__
_Utility _Redline Utility _Landscape
Ii(�
City of Fort Collins
Project Comments Sheet
Selected Departments
City of Fort Collins
Department: Engineering
Date: April 29, 2005
Project:
RIGDEN FARM, 13TH FILING, BROOKLYN PARK ROW HOUSES PDP
All comments must be received by Steve Olt in Current Planning, no later than the
staff review meeting:
April 27, 2005
Note - Please identify your redlines for future reference
Issue Contact: Marc Virata
Topic: Construction Plans
Number: 21 Created: 4/27/2005
(4/27/051 On Sheet 4, show the patching notes along Iowa Drive to be half a parking lane
width not 1' and reference Note #7.
Number: 22 Created: 4/27/2005
[4/27/051 Given the notes 4-6 on Sheet 5 it would appear to be appropriate to have City
Light and Power added to the City's approval block and have individual approval blocks for
both Xcel and Qwest.
Number: 24 Created: 4/27/2005
(4/27/051 Please label the contour lines outside of the property boundaries to better verify
that grades are being tied into properly on -site.
Number: 25 Created: 4/2V2005
[4/271051 The silt fence and storm pipe information on Sheet 6 obscures the on -site contour
line information. Please revise to make this area clearer.
Number: 26 Created: 4/27/2005
[4/27/051 The longitudinal grades for the driveway entrances past the sidewalk along Iowa
Drive are in the 11% range which exceeds the criteria specified in LCUASS Figure 8-17
which requires no more than 4% grade for a distance of 65 from the flowline of Iowa Drive.
Number: 27 Created: 4/27/2005
[41271051 As a suggestion (not a requirement), the use of inverted crown asphalt drives,
(especially in areas�ch as these with tall structures surrounding) may be problematic with
Da e
(HECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat ✓' Site Drainage Report Other
r Utility /Redline Utility Landscape
Page 1
regards to winter months and potential freeze -thaw -freeze issues. With some slopes in the
1.3% range, water may not drain sufficiently along these grades with asphalt such that icing
conditions may occur. It may be worth looking into using concrete for these potential safety
and maintenance issues.
Number. 28 Created: 4/27/2005
(4/27105] The variance request regarding the driveway separation is acceptable. The
variance regarding depth to the first parking stall is likely acceptable, though I would like to
verify the resolution of ID 26 before committing to the approval of this variance request as
there seems to be some interrelation between the two.
Number: 31 Created: 4/27/2005
[4/27/051 It needs to be verified at this time how roof drainage will be directed. It needs to
be demonstrated that such drainage won't be directed over a public sidewalk (Custer or
Iowa).
Number: 41 Created: 4/29/2005
[4/29/05] The plans need to ensure that no above ground pedestals are located in between
any public sidewalk and curb and gutter of the associated public street.
Number: 42 Created: 4/2912005
[4/29/05] The plans need to ensure that any above ground structures are separated 2' from
any public sidewalk.
Topic: General
Number: 23 Created: 4/27/2005
[4/27/05] Given comments thus far, a utility coordination meeting may be beneficial.
page 2
Cityof Fort Collins
Current Planning
REVISION
COMMENT SHEET
DATE: June 16, 2005 TO: Technical Services
PROJECT: #56-98AD Rigden Farm 1 lth Filing, Brooklyn Park
Row Houses PDP
All comments must be received by Steve Olt no later than the staff
review meeting:
June 29, 2005
Note - Please identify vour redlines for future reference
❑ No Problems
Problems or Concerns (see below or attached)
1. i3&V tj P' l e'i j LEG,gL (Los,- .
2. NE PI; rR, 1NcoaeECT 23E,44e� je- one �/l1ERGL-n/GY /,ACCESS cASE,nF�T
3.01Ai,< iQe-c� ull� 77-fcL (5c/ic-U7k-� +\tVLrt.aPa
LIh S A SGC 1r� L-1N�
% /2Ac-r
/S T/2/acz A y7—/-//.✓
6/Z7Z9S—
�I(7y?-161-i - CIIVej
Name (please print)
CHECK IIERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
/Plat _Site _Drainage Report _Other
_Utility _Redline Utilitv _Landscape
6a
City of Fort Collins
Project Comments Sheet
(man Selected Departments
City of Fort Collins
Department: Engineering
Date: June 24, 2005
Project:
RIGDEN FARM, 13TH FILING, BROOKLYN PARK ROW HOUSES PDP
All comments must be received by Steve Olt in Current Planning, no later than the
staff review meeting:
June 29, 2005
Note - Please identify your redlines for future reference
Issue Contact: Marc Virata
Topic: Construction Plans
Number: 22 Created: 4/27/2005
[6/20/05] Please place the Qwest and Xcel approval blocks also on the cover sheet.
Ensure that Light and Power is added to the City approval block on each sheet.
[4/27105] Given the notes 4-6 on Sheet 5 it would appear to be appropriate to have City
Light and Power added to the City's approval block and have individual approval blocks for
both Xcel and Qwest.
Number: 26 Created: 4/27/2005
[6/21/05] The revised drawings at 5% helps address the issue. A variance request is still
required, however we've discussed internally in Transportation that the request can be
supported.
[4/27/051 The longitudinal grades for the driveway entrances past the sidewalk along Iowa
Drive are in the 11 % range which exceeds the criteria specified in LCUASS Figure 8-17
which requires no more than 4% grade for a distance of 65' from the flowline of Iowa Drive.
Number: 28 Created: 4/27/2005
[6/21/051 Carried over pending the receipt of the variance request.
14/27/051 The variance request regarding the driveway separation is acceptable. The
variance regarding depth to the first parking stall is likely acceptable, though I would like to
verify the resolution of ID 26 before commiting to the approval of this variance request as
there seems to be some interelation between the two.
Number: 41 Created: 4/29/2005
[6/201051 The utility/horizontal control plan shows telephone vaults between the sidewalk
and curb and gutterin the right-of-way..Do flush mounted telephone vaults exist? Both the
z
Signature
v� Dale
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat Site Drainage Report Other_
Utility _/ Redline Utility Landscape
Pace I