Loading...
HomeMy WebLinkAboutREGENCY PARK PUD SECOND - Filed CS-COMMENT SHEETS - 2008-05-29En �qo DA i E: ITEM: 26 Sep 89 25_811 D=D Ll A i MEN REGENCY PARK PUD, 2nd Filing - Preiimirnay/Final No Problems Problems gQr Concerns (see below) Date �D/ '��� Signature 010 Services Planning Citv of Fort Collins October 18, 1989 Mr, Dan Herlihey Frederick Land Surveying 1528 North Lincoln Loveland, CO. 80537 Dear Mr. Herlihev: Staff has reviewed the request for Regency Park P.U.D., Second Filing, Prelimi- nary and Final, and offers the following co-- ffiMZ %-r I. The following comments pertain to the Storm Drainage Report: A. The drainage channel in Tract A needs to be addressed with this filing since the channel has no "outlet" east of the 42 inch culvert crossing. An easement may be needed on the cast side of Regency Drive to allow an outlet. B. The offsite regional pond was to have been completed with Regency Park First Filing. No work has yet been done. What is the status of this improvement? C. Please expand on the details of the offsite flows. D. The drainage of Harmony Road should be addressed. E. The utility plans should indicate drainage easements along all property lines that will be accepting drainage from upslope lots. F. The utility plans should show building envelopes and footing and foundation elevations. G. The utility plans should include a drainage table and an expanded legend. H. Drainage casements should be indicated on the grading plan. 1. Please address erosion control measures. Existing facilities need to be protected. This includes any regrading work to be done in the Tract A channel. J. A cross -sectional view of the Tract channel should be included showing the 100-year water surface elevation. Will the trees adjacent to the existing masonry fence interfere with the storm flows? Please verify. -uo LaPorte -Avenue • P0. Bciv ;80 • Fort Cullins, CO R052:-16DU • 13U3} _21-(, 70 n 140 2. Enclosed please find a standard format for requesting variances from the street design standards. Please prepare the variance request in confor- mance with this guideline. 3. A soils report with copies must be submitted. If the 1983 report is to be submitted, it must be updated to current standards. 4. Hilburn Drive must be overlayed due to the number of street cuts. 5. The street trees along Harmony Road should be located between the detached sidewalk and curb in the "parkway strip". The strip must be a minimum of 9.5 feet wide. This will create a pleasant pedestrian experi- ence by buffering the arterial street with trees. Also, the Stormwater Utility does not recommend trees in the drainage tract. 6. The final location of street trees must be coordinated with Light and Power underground vaults. Any tree in conflict with a vault must be shifted. 7. Any modifications to the existing electrical system will be at the developer's expense. 8. Water and sewer mains are existing in Hilburn Drive. Mains to serve the residences Voge and Zahn Courts must be connected to the utility mains in Hilburn. Any existing services along Hilburn must be either used or abandoned at the main. 9. There are two existing sewer mains which were built south from Hilburn as part of the previously proposed development. These mains do not align with either Voge or Zahn Courts, and must be abandoned at their point of connection in Hilburn. 10. The parking total should be revised to 32 rather than 64 since the Zoning Code does not recognize "tandem" spaces. 11. Please be cautioned that any building that exceeds 25 feet in height will be required to submit an administrative change. Many two story homes exceed 25 feet in height. 12. It will be confusing to have a Voge Court lining up directly with Hilburn Court. Voge Court should be renamed to Hilburn Court. The addressing sequence will resolve any confusion as to individual home location. 13. Please be aware that additional engineering comments are contained on the utility plans and will be forwarded under separate cover. This concludes staff comments at this time. In order to stay on schedule for the November 20, 1989 Planning and Zoning Board hearing, please note the following deadlines: %W v40 Plan revisions are due November 1, 1989, P.M.T.'s, 10 prints, and colored renderings are due November 13, 1989. Site and Landscape Covenants and mylars are due November 16, 1989. Please call if there are any questions or concerns or to set up a meeting. Sincerer 1-1 Ted Shepard, Project Planner