Loading...
HomeMy WebLinkAboutFREY STREET COTTAGES - Filed CS-COMMENT SHEETS - 2008-02-25VL1;- 06i11, Selected Issues Report City of Port Collins Date: 2/7/2008 FREY STREET COTTAGES SUBDIVISION PDP - TYPE I AND FINAL PLANS SELECTION CRITERIA: Status = All ISSUES: Department: Engineering Issue Contact: Randy Maizland Number:62 Created:9/13/2006 Resolved [9/13/06] The Acess, Utility and Drainage easement along the southerly border crosses through Lots 4 & 5. This easement will need to be developed such that the utilities can be maintained without interference from permanent structures. Please note on the Utility and Site Plans that no structures may be constructed within the easement that will interfere with maintenance of the utilities or obstruct the surface drainage such as walls or fences. Topic: Engineering Number:81 Created:1/8/2007 Resolved [1/8/07] Please update the date on the cover sheet to January 2007. Number:82 Created:1/8/2007 Resolved [1/8/07] Refer to the Plat: Please label the 9 foot and 15 foot easements adjacent to Frey and LaPorte as Utility Easements. Remove drainage from the label. Indicate on the Plat who will own and maintain Tract A. Number:83 Created:1/8/2007 Resolved [1/8/07] Refer to the Overall Utility Plan sheet: Please show and label the existing and proposed ROW on both Frey and LaPorte. Label items shown on the redlines. Number:84 Created:l/8/2007 Resolved [1/8/07] Street design: The drainage pan at the intersection of Frey & LaPorte will not drain properly with the proposed elevations being shown. A minimum of 0.5% flowline gradient needs to be maintained across the pan if LaPorte drainage is to be conveyed east to the canal. If LaPorte drainage is to be conveyed around the corner and down Frey Street to the new inlet, a minimum fall of 0.5% must be maintained around the corner for adequate drainage. If drainage is being conveyed to the Frey inlet, will a pan even be needed? Please analyze the drainage at the intersection and modify elevations as needed. Number:85 Created:1/8/2007 Pending [2/6/07] Drainage report does not address flows coming off of Laporte going into the new proposed inlet on Frey. [1/8/07] If Laporte drainage is intended to be conveyed to Frey and into the proposed inlet, have the inlets and storm drain been sized to carry these flows? Please provide hydrology calls to verify this. Number: 86 Created:l/8/2007 Pending Page 1 [2/6/07] Intersection has changed to a T intersection without a pan. Still need to show all spot elevations and dimensions per LCUASS 7-28. You can show this on the current plan or provide a separate intersection detail showing all of the required elevation, dimension and slope information. [1/8/07] Please provide radii and all spot elevations per LCUASS Figure 7-27 at the intersection of Frey & LaPorte. Number:87 Created:1/812007 Resolved [1/81071 For the off -site street design of Frey Street to the south, no single point grade breaks of greater than 0.4% are allowed. Please show design point grade brakes and provide vertical curve data if necessary. Number:88 Created:l/8/2007 Pending [2/6/07] Repeat comment. [1/8/07] Show and label the approximate limits of street cut to construct Frey where it ties into Laporte. Please add the City standard street cut note to the Frey Street Plan. Note is attached to the redlines. Number:89 Created:118/2007 Resolved [1/8/07] Please label the vertical curve distances on the profiles. Number:90 Created:2/5/2007 Pending [2/5/07] Please refer to sheet 6, street design for Frey Street - The City has determined that the elevations on Laporte will be slightly lower when the street is reconstructed in the near future. A design elevation of 5047.79 was provided to you prior to the last submittal which is the future elevation at the westerly PC on the southwest corner. You will need to design and build to that future elevation for the drainage to work properly once Laporte is reconstructed by the City. Please revise the plan to show this elevation and how the new curb and gutter will tie back into the existing curb and gutter on Laporte. Number:91 Created:2/6/2007 Pending [216/07] Please call out the new proposed H.C. ramps with LCUASS standard drawing 1606 on the street plan for Frey Street. Number:92 Created:2/6/2007 Pending [2/6/07] Please remove the intersection detail LCUASS drawing no. 708 and replace with Figure 7-28 detail. Number:93 Created:2/6/2007 Pending [2/6/07] Need to add a type II barricade at the end of the sidewalk on Frey. Topic: General Number:7 Created:7/17/2006 Resolved [7/17/06] Please complete and return the Development Agreement Information Sheet with your next submittal for purposes of preparing a development agreement for this project. Number:53 Created:9/7/2006 Resolved [9/7/06] 2nd round comments may be resolved at final compliance stage. OK with Engineering to schedule for a hearing. Page 2 Topic: Site Plan Number:8 Created:7/17/2006 Resolved [7/171061 The existing attached sidewalk along Laporte will need to be removed and replaced with new detached sidewalk, 5 feet in width. Please show a proposed 5 foot wide detached sidewalk on Laporte which transitions to the attached sidewalk crossing the bridge over the Larimer County Canal No. 2. The southerly side of Laporte shall be designed as a 2 lane collector per LCUASS standards. This requirement was provided at the conceptual review meeting by Transportation Planning. Number:9 Created: 7/1712006 Resolved [7/17/06] Show a new directional handicap ramp at the southeast corner of Laporte and Frey. Topic: Technical Services Number:36 Created: 7/2612006 Resolved [7/26/06] The road connecting Mountain and Laporte was dedicated as Frey Street by previous plat. The City street maps show Frey Avenue which is incorrect. Unless it can be shown that the name change was recorded as avenue, the street name and project name should be changed to Frey Street. Number:98 Created:2/14/2007 Pending [2/14/071 Please add a reference note to the Plat regarding allowable uses within the wildlife buffer zone. See redlines for note language and code reference. Topic: Technical Services Number:61 Created:9/13/2006 Resolved [9/13/06] The northwest corner of Lot 9 is labeled incorrectly on the Plat. Please indicate on the Plat who owns Tract A and who will be responsible for maintenance of this Tract. Topic: Utility Plans Number:10 Created:7/17/2006 Resolved [7/17/06] Please title the plan set and Utility Plans "Frey Street Cottages". Number:11 Created:7/17/2006 Resolved [9/7/06] The LCUASS figures provided on the cover sheet and detail sheet are to small to read the text. Please remove the text completely and enlarge the street section information. [7117/06] Provide typical street cross sections for both Frey and Laporte on the cover sheet. Number:12 Created:7/17/2006 Resolved [7/17/061 Add a signature block to the cover sheet and all other applicable sheets for the ditch company, Larimer County Canal No. 2. Number:13 Created:7/17/2006 Resolved [7/17/061 Refer to sheet 4, Overall Utility Plan: Show new proposed detached sidewalk and directional curb ramps along Laporte. Consult with Doug Moore with Natural Resources for acceptable type of rip -rap design. Provide rip -rap details on sheets 7 and 8. Number:14 Created:7/17/2006 Resolved [7/17/061 Refer to sheet 5, Grading Plan: Add the City standard approval signature block to the lower right hand corner. Show detached sidewalk and direction curb ramps along Laporte. Page 3 Number:15 Created:7/17/2006 Resolved [7/17/06] Please provide a plan and profile for the proposed storm sewer pipe which extends from Frey to the canal along the southerly boundary of the site. You will only need to provide this plan and profile for the section within the right-of-way. Please show existing and proposed ground surfaces over the pipe in the profile. Number:16 Created:7/17/2006 Resolved [7/17/06] Refer to sheet 6, Street Plan: Add City standard approval signature block to the lower right hand corner of the sheet. Number:17 Created:7/17/2006 Resolved [7/17/06] Provide details for the proposed inlets shown on Frey Street. Why are area drain inlets being used rather than side opening flowline inlets on Frey? Number:18 Created:7/17/2006 Resolved [7/17106] Please dimension the Frey Street right-of-way (travel lane, parkway, sidewalk). Number:19 Created:7/17/2006 Resolved [7/17/06] Please show detached sidewalk and directional curb ramps at the southeast corner of Frey and Laporte. Provide ramp details. Number:20 Created:7/17/2006 Resolved [9/7/06] Still need to provide corner radii information and additional flow line elevations on the corners and along the pan at the intersection. See red line comments. [7/17/061 Provide curb return radii and flow line elevations at both corners of Frey and Laporte. Number:21 Created:7/17/2006 Resolved [917/06] Site obstructions are off -site and will require code enforcement action by the City to resolve. [7/17106] Please field check and address sight distance to the west at the intersection of Frey and Laporte. This is an off -site problem but may be able to be taken care of through coordination and cooperation with the adjacent property owner on the southwest corner. Number: 22 Created:7/17/2006 Resolved [9/7/06] [7/17/06) See redline prints for additional comments and clarification. Department: Transportation Planning Issue Contact: David Averill Topic: Water/WW Number:58 Created:9/12/2006 Unresolved [9/12/06] no comments Page 4