Loading...
HomeMy WebLinkAboutHARMONY SCHOOL SHOPS SIXTH - Filed CS-COMMENT SHEETS - 2007-11-26STAFF PROJECT REVIEW Citvof Fort Collins Jeff Hosea 1136 E Stuart St. Bldg 2, Ste 2040 Date: 01/03/2007 Ft. Collins, CO 80525 970472-8954 Staff has reviewed your submittal for HARMONY SCHOOL SHOPS PRELIMINARY DESIGN REVIEW, and we offer the following comments: ISSUES: Department: Advance Planning Issue Contact: Clark Mapes Topic: Transportation Planning Number: 16 Created: 12/19/2006 (12/19/06] There is little synergy between the buildings. They are separated about as far as possible from each other. I would like to discuss this at the meeting. On the layout as shown, the neighborhood connection should be given special attention with special sidewalks, and crosswalks, and the walkway along the west side of the building. Every effort has been made to address this comment in a thoughtful and beneficial design solution. The two separate pads are now only separated from the main building by a drive at each end of that main building. On the west, a large public plaza and gathering space will now make the small 2000 square foot building seem a part of the main building. East to west traffic flow has been disconnected at the southwest corner of the main building in order to facilitate this providing a very wide, landscaped plaza area. The 6000 square foot building at the east end is now only 65' from the main building with a walk connecting to another smaller public plaza and gathering space at that corner of the main building. The neighborhood connection to the north is being facilitates by an extra wide walk on the south side of the entry drive. This walk enters a large landscape island with a 10x10' gazebo and then crosses the drive to the main building. This amenity will help add height to the parking lot, provide a nice structure to help separate the main building from the street and neighborhood and become the secondary focal point after the main public plaza. Providing a walk on the north side of the entry drive became unfeasible with the detention pond, entry sign and planting beds. Also, we feared that providing access on the north might cause the gazebo to become too far removed for daily use. The west side of the building has been dressed up considerably from the first architectural elevations and footprint that were shown during the PDR. With columns, building articulation, multiple roof planes, large expanses of tinted glass and landscape beds separating the drive from the pedestrian walk, we have provided a nice urban environment for neighbors to enter the project and have made it easily adaptable to future uses should the need arise to split this building into multiple tenants. Department: Engineering Issue Contact: Marc Virata Topic: Engineering Number: 5 Created: 12/19/2006 [12/19/061 The area shown on the site plan comprises of at least two different plats, Harmony School Shops 4th and Harmony School Shops 5th Filing. A third plat may also be Page 1 involved for the 2,000 sq. ft. building shown towards the southwest corner of the site that appears to straddle a property boundary. Is it intended that a replat will occur to bring about the site plan under one plat and rectify existing easement delineations that may no longer be applicable with this revised design? Since the land area still appears to be area comprised of the 4th Filing, any replat that occurs we would prefer having a note added reflecting that the development agreement for the 4th Filing should apply to this project. Completed by JR Engineering Number: 6 Created: 12/19/2006 [12/19/061 An update to the T.I.S. for Harmony School Shops 4th Filing will likely be needed with this project. Contact Eric Bracke, City Traffic Engineer for verification. With less traffic being generated by less intensive uses, less square footage of leasable building and less tenants, the approved 4'" Filing T.I. S. should still be valid per Ted Shepard. Number: 7 Created: 12/19/2006 (12/19/061 As the project is a departure from the design the previous 4th Filing, the construction drawings will need to be updated. We will need to work through with your consulting engineer how the changes will be documented, either by revisions to the 4th Filing plan set, a new plan set submittal, or both. Completed by JR Engineering Number: 8 Created: 12/19/2006 [12/19/061 The site plan seems a little unclear as to whether certain improvements (such as sidewalk along Harmony Road and the Walgreen's site) are existing or to be redone with this project. Completed with prior Phases of development, not with this Major Amendment. Department: PFA Issue Contact: Carle Dann Topic: Fire Number: 17 Created: 12/20/2006 [12/20/06] REQUIRED ACCESS: A fire lane is required. This fire lane shall be visible by painting and signage, and maintained unobstructed at all times. A fire lane plan shall be submitted for approval prior to installation. In addition to the design criteria already contained in relevant standards and policies, any new fire lane must meet the following general requirements: C Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire apparatus weights. Compacted road base shall be used only for temporary fire lanes or at construction sites. E Have appropriate maintenance agreements that are legally binding and enforceable. E Be designated on the plat as an Emergency Access Easement. E Maintain the required minimum width of 20 feet throughout the length of the fire lane. 07UFC 901.2.2.1:901.3; 901.4.2; 902.2.1 Completed. Page 2 Number: 18 Created: 12/20/2006 112/20/061 AUTOMATIC FIRE SPRINKLERS: Any proposed building exceeding 5,000 square feet for type V construction shall be fire contained or fire sprinklered. The proposed buildings larger than 6,000 SF shall be equipped with approved automatic fire sprinklers; the Proposed 6,000 SF building may be fire contained or have automatic fire sprinklers. 97USC Table 9-B (City of Fort Collins Amendment) Completed. Number: 19 Created: 12/20/2006 [12/20/061 FIRE DEPARTMENT CONNECTION: Fire department connections shall be installed remote from the buildings, and located on the street or fire lane side of buildings, fully visible and recognizable from the street or nearest point of fire department vehicle access or as otherwise approved by the fire code official. 2006 International Fire Code 912.2.1 and PFA Bureau Policy Completed Number: 20 Created: 12/20/2006 [12/20/061 FIRE LINE: The fire lines for the automatic sprinklers shall be a minimum of 6 inches in diameter, unless hydraulic calculations show that smaller lines will provide adequate fire flow. Completed Number: 21 Created: 12/20/2006 [12/20/06] KNOX BOX REQUIRED: Poudre Fire Authority requires a "Knox Box" to be mounted on the front of every new building equipped with a required fire sprinkler system or fire alarm system. 97UFC902.4; PFA BUREAU POLICY 88-20 Completed Number: 22 Created: 12/20/2006 [12/20/06] WATER SUPPLY: Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Spacing and flow requirements include: Commercial, 1,500 g.p.m. at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter. 97UFC 901.2.2.2 Completed Number: 23 Created: 12/20/2006 [12/20106) TURNING RADII: Minimum turning radii is 25 feet inside, 50 feet outside, through all drive cuts, private drives, drive aisles, etc. Number: 24 Created: 12/20/2006 [12/201061 ADDRESS NUMERALS: Address numerals shall be visible from the street fronting the property, and posted with a minimum of six-inch (6) numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). Some of the proposed structures may require address numerals mounted on more than one side of the building, to more easily identify the location. 97UFC 901.4.4 To Be Determined Page 3 Department: Transportation Planning Issue Contact: David Averill Topic: Transportation Planning Number: 9 Created: 12/19/2006 [12/19/061 All walkways that are adjacent to head -in parking must be 6' in width unless wheel stops are to be provided. Several locations where this situation occurs need to be verified or corrected. See redlines site plan. Completed Number: 10 Created: 12/19/2006 (12/19/061 Proposed bike rack locations need to be shown on site and utility plans. These racks need to be located near the store entrances and well -distributed around the center. Completed- 7 Racks in total have been provided. Number: 11 Created: 12/19/2006 [12/19/061 Several walkways are missing where needed. See redlines. Completed- Pedestrian connectivity has been addressed extensively. Number: 12 Created: 12/19/2006 [12/19/06] All sidewalk access ramps must be radial vs. directional. Completed- accept where crossing on a tangent of an island Number: 13 Created: 12/19/2006 [12/19/06] Need a wider walkway (6' if attached) and access ramps leading along drive aisle from Milestone to 36k sq. ft. building. Completed Number: 14 Created: 12/19/2006 [12/19/06] Make sure to verify the cross access connection to the east with the alignment shown with the Pads at Harmony project. This includes providing a consistent alignment for all walkways as well as the drive aisle. Completed Department: Stormwater-Water-Wastewater Issue Contact: Was Lamarque Topic: Stormwater Number: 25 Created: 12/22/2006 (12/22/06] The Site's new impervious area needs to be compared to the already approved Harmony School Shops 4th Filing impervious area to ensure the detention pond has the required volume for this new site plan. Completed by JR Engineering Number: 26 Created: 12/22/2006 [12/22/061 The detention pond for the 4th Filing needs to provide water quality for all basins draining into it. Completed by JP Engineering Page 4 fins Current Planning DATE: March 1, 2007 TO: Engineering PROJECT COMMENT SHEET PROJECT PLANNER: Ted Shepard # 42-89L HARMONY SCHOOL SHOPS, 6TH FILING REPLAT, MAJOR AMENDMENT — TYPE II Please return all comments to the project planner no later than the staff review meeting: March 21, 2007 Note -_Please identify your redlines for future reference ❑ No Problems ❑ Problems or Concerns (see below, attached, or DMS) Name (please print) CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS _Plat _Site _Drainage Report _Other _Utility _Redline Utility _Landscape City of FortCollins PROJECT C:i7 of Dort CollinCOMMENT SHEET ;un-or[P annk:- DATE: March 1, 2007 TO: Technical Services PROJECT PLANNER: Ted Shepard # 42-89L HARMONY SCHOOL SHOPS, CH FILING REPLAT, MAJOR AMENDMENT — TYPE II Please return all comments to the project planner no later than the staff review meeting: - r March 7-1, 2007 Note Please identify Your redlines for future reference /. yip Zi wlDN �'-`� (r'GC.ib,j. ❑ No Problems ❑ Proble s or Concern (see below, attached, or DM 3_ yu.� �;_� �, � � y�,� ram• � � .... ate✓ G- i Z— /:Y•:.74. t,,F�,rr�b�,FT- �I,I,, f„ iY6T 1J f�4T�= 1-V/ Name (please print) CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS _Plat _Site _Drainage Report _Other _Utility _Redline Utility _Landscape City of Port Collins Current Planning DATE: March 1, 2007 PROJECT COMMENT SHEET TO: Engineering Pavement PROJECT PLANNER: Ted Shepard # 42-89L HARMONY SCHOOL SHOPS, 6TH FILING REPLAT, MAJOR AMENDMENT — TYPE II Please return all comments to the project planner no later than the staff review meeting: March 21, 2007 Note - Please identify Your redlines for future reference No Problems ❑ Problems or Concerns (see below, attached, or DMS) �-. LI, X , c- Name (please print) CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS _Plat _Site _Drainage Report _Other _Utility _Redline Utility _Landscape A Project Comments Sheet S City of Fort Collins Selected Departments Date: March 23, 2007 Project: HARMONY SCHOOL SHOPS, 6TH FILING - REPLAT -MAJOR AMENDMENT-TYPEII All comments must be received by Ted Shepard in Current Planning, no later than the staff review meeting: March 21, 2007 Note - Please identify your redlines for future reference Issue Contact: Marc Virata Topic: Construction Plans Number: 22 Created: 3/21/2007 [3/21/07] Please show street patching on the utility plan (in addition to the demo plan). Add the same note regarding street repair limits shown on the utility plan to the demo plan. Number: 24 Created: 3/21/2007 (3/21/071 Please show design information from the approved Pads at Harmony site as verification that the proposed development aligns with the Pads at Harmony design. Number: 25 Created: 3/21/2007 [3121/07] The original 4th Filing plans had an access ramp proposed shown on the north side of Milestone. This plan set shows the ramp in its old location which doesn't align with the new driveway location. Please revise this access ramp location and show an access ramp at the driveway crossing Milestone to line up. Topic: General Number: 14 Created: 3/20/2007 [3120/071 The site plan has the project titled "Major Amendment for Harmony School Shops 6th Filing", I believe this is technically incorrect as the 4th Filing is being amended via a major amendment. The title implies that the 6th Filing is being amended. I believe the title "Harmony School Shops 6th Filing" is appropriate, but a major amendment actually refers to the 4th Filing. .3 3 Date CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS Plat ✓ Site Drainage Report Other Utility Redline Utility Landscape Page 1 Number: 15 Created: 3/21/2007 [3/21/071 As was the case with the 5th Filing, I believe a development agreement specific to this 6th Filing project isn't necessary, provided a note on the plat for this project is in place specifying that all conditions of the 4th Filing DA will apply to this project. Number: 23 Created: 3/21/2007 [3/21/071 There needs to be a sidewalk connection to connect to the Pads at Harmony project. Topic: Plat Number: 20 Created: 3/21/2007 [3/22/071 The previous comment below was clarified after staff review. A letter of intent is not needed and the comment is no longer applicable. The note on the plat though should perhaps be tweaked to potentially avoid confusion in the future. [3/21/07] The plat shows an irrigation easement and notes that its depiction may be in conflict with the legal description. As it potentially does not represent the dedication, I believe the owner of the easement needs to sign the plat. In addition, as the plat seems to be realigning/rededicating the easement, again the owner should sign. The statement of dedication will need to be modified in some manner to reflect that the irrigation easement is not being dedicated to the City. Number: 21 Created: 3/21/2007 [3/21/07] It appears that additional emergency access easements are needed to coincide with Sheet 1 of the site plan depicting fire turning radii - presumably PFA needs these areas as firelanes with emergency access easements on the plat. Number: 35 Created: 3/23/2007 [3/23/071 Technical Services offers the following comments: 1. Boundary closes. 2. Subtitle of plat should include "Replat of ... " 3. How does Lot 8 HSS 4th get utility service? 5. Minor line over text issues. Page 2