Loading...
HomeMy WebLinkAboutWATERGLEN PUD - Filed GC-GENERAL CORRESPONDENCE - 2007-04-19Services Engineering Department City of Fort Collins November 2, 1998 Patricia Kroetch JR Engineering 2620 East Prospect Rd., Suite 190 Fort Collins, Co. 80524 RE: Waterglen P.U.D. Dear Patricia: This response is in regard to your letter dated September 25, 1998, in which you requested a modification to the City's Street Design Standards to allow for a narrower street width on Elgin Place, Glenbarr Court, and Cullen Court. As stated in your request the street width variance is to reduce the dimension of the streets into these cul-de-sacs from 36 feet in width to 28 feet in width. Based upon the short length of street and the few number of lots accessed from these streets, and with the traffic volumes being anticipated at less then 1000 vehicles per day, the 28 foot wide street does not appear to affect the service to these homes. Therefore, the variance request is approved with the following conditions. These streets shall be designed with a minimum width of 28 feet flow line to flow line, with a 7 foot parking lane on each side and a 14 foot travel lane width. All other conditions as required for the City of Fort Collins standards for a residential local street apply. Sincerely, David Stringer v Development Review Supervisor cc: Waterglen P.U.D. file 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6605 Services Engineering Department City of Fort Collins November 4, 1998 Patricia Kroetch 7R Engineering 2620 East Prospect Rd., Suite 190 Fort Collins, Co. 80524 RE: Waterglen P.U.D. Dear Patricia: This response is in regard to your letter dated November 3, 1998, in which you requested a modification to the City's Street Design Standards to allow for a narrower street width on the six (6) private drives in the multi -family portion of the Waterglen P.U.D.. As stated in your request the street width variance is to reduce the dimension of the streets intothe area from 36 feet in width to 24 feet in width. Based upon the short length of street and the type of lots accessed from these streets, and with the traffic volumes being anticipated at less then 1000 vehicles per day, the 24 foot wide street does not appear to affect the service to these homes. Therefore, the variance request is approved with the following conditions. These streets shall be designed with a minimum width of 24 feet flow line to flow line, with a 7 foot parking lane on each side if required and a 12 foot travel lane width. All other conditions as required for the City of Fort Collins standards for a residential local street apply. Sincerely, 7�1: David Stringer Development Review Supervisor cc: Waterglen P.U.D. file 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6605 Services Engineering Department City of Fort Collins November 4, 1998 Dale Stein The Sear/Brown Group 209 South Meldrum Fort Collins, Co. 80521 RE: 36 foot wide interim improvement to Vine Drive Dear Dale: The intent of this letter is to address your request to proceed with a design of the Vine Drive interim improvements using a 3:1 finished side slope instead of the 4:1 finished side slope normally required by the City. After reviewing the plans you have submitted to us, this steeper side slope will be allowed from approximately station 141+00 RT to station 146+00 RT. with the following condition: * All work shall be accomplished within the existing rights -of -way * The stormwater catch ditch will be of sufficient width and depth to catch the stormwater flows from the roadway section without causing injury to or creating more then the historic flow onto the adjacent properties. * The steeper slide slopes will be designed and shown on the Vine Drive Improvement utility plans. * If the catch ditch and other associated work cannot be accomplished within the existing rights - of -way then the Developer of Waterglen P.U.D. will be required to obtain the necessary slope and drainage easements. If you have any questions please contact me. V David Stringer Development Review Supervisor 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6605