Loading...
HomeMy WebLinkAboutHOME STATE BANK - Filed SP-SITE/LANDSCAPE PLAN - 2005-10-24M I1 I 1 � I I 1 1 II EXISTING VETERINARY CLINIC I I I = II I I NGRESS AND EGRESS J L t ARED WITH VET CLINIC - I I I 1 ___ I i 1 1 ----�——— — — — — —J I l i � 1 I w ------------ PA S 89` 46' 11 W 188.27' P PERTY NE u 1 J w 1 wI DRIVE THROUGH LANES DETENTION AREA 23'-9" I wh PA w I N TXIST1f ULDERS z OI v v 30" RETAINING WALL (PLACE AROUND OUTLET) LANDSCAP 1 1 Q VI _ _ —__ SCREEN FOR w O I V ¢ .. _ _ _ _. ___ _.._ _ _ _ _. __.. DRIVE THROUGH oa I I 1 O 1 I 1 w1 v.O DETENTION AREA 9„ Q,- , o I Z j —.. _ PA -EXISTING ARKING LOT / VEGETATION TO — — — LIGHTING, TYP. 28'-8" REMAIN, TYP. XPANSION JOINT, TYP. \ TRASH ENCLOSURE / / / ICYCLE RACK � I � I I ----------- /— — — — — — — — — — — — — — — — — — — — — — — — — — I PA \ HTSEWA _ULDICA \ \ \IN 8Y7 4 208. ' EXISI \ ENTRANCETO \ \ SENIOR CENTER VICINITY MAP SCALE V=500' ISM N�J � I _ NORTH 1 wW Z o, OWNERSHIP CERTIFICATION J UrPA PA wO OTHE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE THE LAWFUL OWNERS OF REAL PROPERTY DESCRIBED ON THIS 9zzSITE PLAN AND D EREBY CERTIFY THAT I/WE ACCEPT THE CONDITIONS AND RESTRICTIONS SET FORTH ON SAID SITE PLAN. i� � SQ HOME STATE B / % y 30" RETAINING WALL OVER RUCTURE w I ; L —1 19, FOR DRIVE THROUGH BY: / / - --- - 1 - ATM DRIVE THROUGH O I EVE FOBES, SENIOR VICE-PRESIDENT CNPA 1 � / / I al w THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS fLt DAY OF �05 BY ,Sf eve Fo(2Es EXISTNG LANDSCAPE TO REMAIN N PA LU PA MY MY COMMISSION EXPIRES: `%v17, a oo 9 o Ln z I �/ \� 4 "° I N WITNESS MY HAND AND OFFICIAL SEAF o 10 0, I \° TYP. C) NOTARY PUBLIC VERHEAD STRUCTURE I PA ` � I J W `XJ�ps•� C/�/ EXISTING SENIOR CENTER ADD SS PARKING LOT PARKING AREA I I MAIN ENTRANCE I I I 1 1 1 1 1 (WALK UP ATM INSIDE) EXISTING LIGHT POLE I I I PROPOSED L-1 J1 a Z j / FF-SI IIE ACCESS EASEMkNT 1 i / NGRESS AND EGRESS LEGAL DESCRIPTION A portion of Tract F of Raintree, a Planned Unit Development and a parcel of land conveyed and described in a deed recorded March 31, 2000 as Reception No. 2000020903 of the Records of Lorimer County, located in the Southeast Quarter (SE1/4) of Section Twenty-two (22), Township Seven North (T.7N.), Range Sixty-nine West (R.69W.), Sixth Principal Meridian (6th P.M.), City of Fort Collins, County of Lorimer, State of Colorado, more particularly described by metes and bounds as follows: BUILDING PATIO AREA - PROPOSED UTILITY .... W-1 T a PA SIDEWALK TO REMAIN DW FENCE -EXISTING PROPERTY LINE RAI NTRE E DRIVE LAND USE DATA PA Z • EXISTING ZONING NEIGHBORHOOD COMMERCIAL (NC) • PROPOSED LAND USE FINANCIAL SERVICE, CLINICS, RETAIL ESTABLISHMENTS, STANDARD RESTAURANTS, OFFICES, FAST FOOD RESTAURANTS, PERSONAL AND BUSINESS SERVICE SHOPS, ARTISAN AND PHOTOGRAPHY STUDIOS AND GALLERIES, CHILD CARE CENTERS, PRINT SHOPS AND FOOD CATERING OR SMALL FOOD PREPARATION CITY MANAGER APPROVED BY THE CIT MANAGER OF THE CITY OF FORT COLLINS, C�rOLgRADO �� ��� , ON THISs�q DAY OF r A.D., 20bs t I i t CITY MANAGER tE} I DIRECTOR OF PLANNING APPROVED BY THE DIRECTOR OF PLANNING OFT CITY OF FORT COLLINS, COLORADO T DAY OF610AONIIA.D., 20�T. DIRECT R OF PLANNING PROPERTY OWNER SHEET INDEX I HOME STATE BANK 1. SITE PLAN 303 E. MOUNTAIN AVENUE 2. PLANTING PLAN FORT COLLINS, CO 80524 3. ARCHITECTURAL ELEVATIONS 4. LIGHTING PLAN GENERAL NOTES 1 . Refer to Utility Plan for location of utilities and drainage facilities. 2. Developer shall ensure that the Landscape Plan is coordinated with the plans done by other consultants so that the proposed grading, storm drainage, or other construction does not conflict nor preclude installation and maintenance of landscape elements. COMMENCING at the Southeast Corner of said Section 22 and assuming the East line of the SE1/4 of said Section 22 to bear North 00°02'57" West, a grid bearing of the Colorado • MAX. BUILDING HEIGHT PERMITTED 70' (5 STORIES) State Plane Coordinate System, North Zone, North American Datum 1983/92, a distance of 2649.35 feet with all other bearings herein relative thereto; • MAX. BUILDING HEIGHT PROPOSED 34'-6" (1 STORY) 3. The building will be equipped with an automatic fire extinguishing system meeting • GROSS SITE AREA 41,124 S.F. (0.944 ACRES) the requirements of the Poudre Fire Authority. THENCE North 00°02'57" West along the East line of the SET /4 of said Section 22 a distance of 1244.94 feet (record distance 1244.72 feet); • ESTIMATED FLOOR AREA FINANCIAL SERVICE - 3,500 S.F. 4. Sidewalks and ramps shall be constructed in compliance with the Americans With THENCE South 89°46'1 1" West a distance of 50.00 feet to the Westerly Right of Way (ROW) line of Shields Street as dedicated in Book 1686, Page 540 of the Records of Lorimer REAIL USE - 3,000 S.F. Disabilities Act. Handicap accessible routes shall slope no more than 1:20 in direction County and the POINT OF BEGINNING; • FLOOR AREA RATIO 0.16 of travel and no more than 1:48 cross slope. THENCE South 89°46'1 V West along the South line of Tract F of the Raintree PUD recorded May 29, 1981 as Reception No. 413446 of the Records of Lorimer County, a distance of • PUBLIC ROW: 2,127 SE (0.049 ACRES) 193.12 feet to the East line of Tract "A" of the Fort Collins Senior Center P.U.D. as recorded September 15, 1993 as Reception No. 93067048 of the Records of Lorimer County; • NET SITE AREA 38 997 S.F. (0.895 ACRES) 5. Rooftop and ground -mounted mechanical equipment shall be totally screened from THENCE South 00°02'57" East along the East line of said Tract 'A" a distance of 204.06 feet to the Northerly ROW line of Raintree Drive as dedicated April 2, 1985 as Reception No. public view from sidewalks and abutting streets. 8501 5147 of the Records of Lorimer County and to the beginning point of a Curve to the East; • SITE COVERAGE AREA PERCENT THENCE along the said Northerly ROW line of Raintree Drive and along the arc of a Curve concave to the South a distance of 15.52 feet, said curve has a Radius of 274.00 feet, a BUILDING COVERAGE 6,500 S.F. 16% 6. Building -mounted and pole -mounted light fixtures shall feature sharp cut-off, Delta of 03°14'42", and is subtended by a Chord bearing North 88'19'42" East a distance of 15.52 feet to a Point of Tangency; DRIVES AND PARKING 19,756 S.F. 48% down- directional luminaries. The light source shall be 150 watt high pressure sodium. THENCE North 8905703" East continuing along the said Northerly ROW line of Raintree Drive a distance of 177.61 feet to the Westerly ROW line of Shields Street as shown on the plat PUBLIC R.O.W. 2,127 S.F. 5% 12,741 S.F. 31% Pole height and color shall match the existing poles in the center. of Raintree, a Planned Unit Development recorded May 29, 1981 as Reception No. 413446 of the Records of Larimer County; OPEN SPACE ACTIVE RECREATIONAL USE AREA 0 S.F. 0% 7. Trash sfrromtpublicrash ovewactors, pallet racks, and miscellaneous objects shall be THENCE North 00°02'57" West along said Westerly ROW line of Shields Street a distance of 7.18 feet to the South line of that parcel of land as described in a Warranty Deed recorded TOTAL 41,124 S.F. 100% totally screened March 31, 2000 as Reception No. 2000020903 of the Records of Larimer County THENCE North 89146'11" East along the South line of said parcel of land a distance of 20.00 feet to the Westerly ROW line of Shields Street, said line being parallel with and 30.00 AUTOMOBILE PARKING 8. Signage to comply with City of Fort Collins Sign Code. feet Westerly of, as measured at a right angle to the East line of the SE /4 of said Section 22; ALLOWED PER USE H RETTAILAIL UUSE SERVICE SE Iz 12 THENCE North 00002'57" West along said Westerly ROW line of said Shields Street a distance of 57.04 feet to the Southeast corner of said parcel of land dedicated as Shields Street SHARED SENIOR CENTER PARKING 8 9. Electrical transformers shall not be located along S. Shields Street unless totally ROW in Book 1686, Page 540; STANDARD SPACES 30 screened from view from the public right-of-way by a solid enclosure that matches the THENCE North 1 W29'57'' West along the Southwesterly ROW line of said Shields Street as dedicated in Book 1686, Page 540 a distance of 63.20 feet; HANDICAP SPACES 2 predominant building material of the closest building. For all other locations, electrical THENCE North 00°02'57" West along the Westerly ROW line of said Shields Street as dedicated in Book 1686, Page 540 (said ROW line being parallel with and 50.00 feet Westerly of, TOTAL PARKING SPACES 32 transformers shall be screened from view from public or private streets by a solid enclosure, landscape materials, building facades or any combination thereof. as measured at a right angle to the East line of the SE 1 /4 of said Section 22), a distance of 80.00 feet to the South line of said Tract F and the POINT OF BEGINNING. • BICYCLE PARKING Said parcel of land contains 41,125 sq. ft. or 0.944 acre, more or less (-), and is subject to any rights -of -way or other easements of record or as now existing on said described parcel BICYCLE RACKS 1 10. There shall be no outdoor placement of illuminated vending machines. of land. TOTAL BICYCLE PARKING 2 F SCALE: V" 20' N O R T H 0 10' 20' 40' ■ � OEM MrftftM FINAL COMPLIANCE PLAN HOME STATE BANK S. SHIELDS STREET & RAINTREE DRIVE FORT COLLI"S, COLORADO BI IA DFSIGN, INC. • 4803 INNOVATION DRIVE FT. COLLINS, CO 80525 • 1E1. (9/0) 223 - 7577 S F--1 E ET l of 4 SEPTEMBER 1 2, 2005 H — 123 243 CI T -- --- _ _ ——\\\\ REPRESENTATIVE PLANT LIST o f�� �- -- -- --- -- - Key Botanical name Common Name Size at Root Spacing Qty. Notes { Nr r� Planting DECIDUOUS GIedANOP ca TREES mermis 'Skyline' Cal. BB See Plan 4 l-r------- y Skyline Honeylocust 3" i j' / r-� ' � FIR AM Fraxinus americana'Autumn Purple Autumn Purple Ash 3' Cal. BB See Plan 4 /i oa 1 I I FIR PE Fraxinus pennsylvanica'Summit' Summit Ash 2" Cal. BB See Plan 4 ii CrN " ORNAMENTAL TREES MA RA Malus'RadionP Radiant Crabapple 1 1/2' Cal. BB See Plan 1 MA SP Malus'Spring Snow' Spring Snow Crabapple 1 1/2" Cal. BB See Plan 1 1 I EVERGREEN TREES I 1 PI ED Pinus edulis Pinon Pine b' Height BB See Plan 4 DECIDUOUS SHRUBS & GROUNDCOVERS CE MO Cercocarpus montanus Mountain Mahogany 5 Gal. Cont. See Plan 13 EU CL Euonymus fortunei'Coloratus' Purpleleaf Wintercreeper 5 Gal. Cont. See Plan b i !, �--- I'li EU FO Euonymusfortunei'EmeraldnGold' Emerald'n' Gold Euonymus 5 Gal. Cont. See Plan 9 = I — (— i — - J= —�I _ — — _ — — _ — — _ — I ll PE AT Perovskia sseatryi icawn Russian Sage 5 Gal. Cont. See Plan 18 I — — — — — — — PR BE Prunus Besse i 'Pawnee Buttes' Creeping Western Sandcherry 5 Gal. Cont. See Plan 10 l -- _ I t __ J---------Il ---y-- RO A Rosa woodsn Native Pink Rose 5 Gal. Cont. See Plan 12 I I SP JA Spiraea laponica'Froebelii Froebel Spirea 5 Gal. Cont. See Plan 10 ;---- SY PA Syringa patula 'Miss Kim' Miss Kim Dwarf Lilac 5 Gal. Cont. See Plan 16 vulga SYVU Syringa vulgaris'Charles Joy' Double Red French Lilac 5 Gal. Cont. See Plan 12 ll I ��. 1 FIR l' 9 PE AT EVERGREEN SHRUBS ( 9 MI SI 9 PE AT 9 MI SI l I i i I _ JU HO Juniperus horizontalis'Wiltonii' Wilton Carpet Juniper 5 Gal. Cont. See Plan 36 28 CA AC — IRRIGATE �� � 4 PI ED Spa I i i r I i JU SA Juniperus sabina'Broadmoor Broadmoor Juniper 5 Gal. Cont. See Plan 14 10 HE SE I :. li I l I Calamagrostis acutiflora Feather Reed Grass 1 Gal. Cont. See Plan 49 � � i GRASSES & PERENNIALS �...— _ ... ...—...—.. °� 12 CA AC Ili I CA AC I 6 SY VU dP� I I o DHEOHE I WH DHed arhelPectabilis Old Fashioned Bleeding Heart 1 Gal. Cont. See Plan 4 "R R VEL NCH BED I s I p'Alba' White Bleeding Heart 1 Gal. Cont. See Plan 8 — I J I i I i�.i l HE P Hemeroebold aaalsEPin ' English Ivy 1 Gal. Cont. See Plan 16 Train up structure — — —.. — — ._—.___.__. .—..—..—... g Pink Daylily 1 Gal. Cont. See Plan 45 t� I I I❑ Il s Blue Avena Grass 1 Gal. Cont. See Plan 40 ►"4 i i i l HE SE Helictotrichon sem erviren — O S Blue Giant Plaintain Lily 1 Gal. Cont. See Plan 7 J HO FO Hosto x fortunei 'Patriot' Patriot Hosta 1 Gal. Cont. See Plan 8 MI SI Miscanthus smensis'Strictus' Porcupine Grass 1 Gal. Cont. See Plan 27 3 SY VU I ST TE Stipa tenuissima Mexican Feather Grass 1 Gal. Cont. See Plan 15 9 CA AC I I I I I I b EU CL / A GRAVEL MULCH BED I LiI o ;i IRRIGATED SOD MIX (THIS AREA) I to 1 FIR PE l z"i 60% Eldorado, Silverado and Monarch Turf Type Tall Fescues / / L — I b 1U HO 3 JU HO 3 CE MO 4 CE MO I' ' I ii 30% Manchor Smooth Brame o 1 CE MO 9 EU FO I.IRRIG D SO q MA jZq it 10% Bluegrass Mix (Drought tolerant) a 1 FIR PE 5 CE MO2JU HO PLANTING NOTES ---- w N / � � I � — �• ` l W 1 . Landscape materials shall be in accordance with AAN specifications for Number One Grade. / I o —.. .. —..—.. � b HE HE 2. Turf areas shall be irrigated with an automatic pop-up irrigation system. Shrub beds and trees to be irrigated with an automatic drip / 9 JU HO - -- — 3 HO SI b JU SA I8 HE HE 4 MI SI ( (trickle) irrigation system. The irrigation plan shall be reviewed and approved by the City of Ft. Collins prior to the issuance of a building 1 FIR AM 1 FIR PE I permit. 4 RO WO I 2 PR BE 1 �`.� \ it 3. Trees to be balled and burlapped, unless otherwise noted. W l'i i I 2 PR BE it _ 4. Perennial beds to be mulched with 2" depth cedar mulch. No weed barrier shall be placed in perennial beds. 1 FIR WO I 3 PR BE = I 5. Shrub beds shall be mulched with a 3" y f 1/2" to 1" rock mulch over non woven polypropylene weed barrier such as Typor or Mirafi. RO 22 HE S �� layer o I AM 4 RO WO I I 6. Edging between turf and shrubs shall be 1/8' X 4 steel edging. in Ed m shall be coned at 10' intervals at a minimum, and a 1" opening I 10 JU HO ----J 9 9 9 9 Edging P — — I "—"' r....... �—. ❑ 4 HDO SI I OFDGER l l shall be provided at low points and 30' intervals to allow for drainage. Edging shall also be provided between perennial beds and shrub II 11 I �..—. 4 DI WH Ff 3 PR BE d'G beds. Edging abutting sod or grass shall be set flush with the finished surface. 4DIW .. 4 HO FO : P N Y P p prune 4 HO FO 2 MI SI I of .i I: 7. A Free permit must be obtained from the City Forester before an trees or shrubs as noted on this Ian are lanted,d, or removed in the public Right of Way. 2HEHE 1 FIR AM 8 HE SE I 'i 8. Landscaping must be installed or secured with on irrevocable letter of credit, Performance Bond, or escrow account for 125% of the valuation of the REPLACE BARKING 4JUSA r / I materials prior to issuance of a Certificate of Occupancy. / 3 i Ili l� — — 1 FIR AM SEE NOTE BELOW FOR TREE 3 MI SI ^ I 9. Landscaping shall be maintained by the property owner. WITH TUR I � — — — — — — — � — — — — — — j— \ 14 SY PA-1,10 SP JA ( REPLACEMENT SCHEDULE 4 JU SA o is 10 Parking II be screened from c streets T...—. —_—.. rking shall om public is by plants, fencing, and/or berming. 0l1 b 1U HO Zl I 11. Soil in landscape areas shall be amended with 3 cy/1,000 sf well composted manure. I3 SY VU % i r r r 12. The following separations shall be provided between trees/shrubs and utilities: L.—...�...—... ... - I MA SP, 1 40 feet between canopy trees and street lights 15 feet between ornamental trees and streetlights i 10 feet between trees and public water and sanitary and storm sewer lines IRRIGATED SO I$$LGA ._� �Y �- p ry - -,-' ' 4 ST TE 1 1 ST TE - - \�' 4 feet between trees and public water and sanitary and storm sewer lines - / 4 feet between trees an g lines Field locate utilitiesprior tplanting. -- 37 HE H - -- -- - - -- _ -__ — -- _ _ 13. To the maximum extent feasible, topsoil that is removed during construction activity shall be conserved for later use on areas requireing revegetation $ HE�-iP � -- - - --'- --�- � - --- - -- ---- --- - --- --- and landscaping. 4 GL TR 14. Where necessary, existing trees shall be pruned to City Forester medium prune standards. RAINTREE DRIVE r 15. A free permit must be obtained from the City Forester before any trees or shrubs as noted on this plan are planted pruned or removed in the public right-of-way. This includes all areas between the sidewalk and curb and street medians. This permit shall approve the location and species to be planted. ;.. _. Failure to obtain this permit may result in replacing or relocating trees and a hold on certificate of occupancy. V 16. The developer shall contact the City Forester to inspect all street tree plantings at completion. All trees need to have been installed as shown on the landscape plan. Approval of street tree planting is required before final approval. Failure to obtain approval by the City Forester for street tree planting / - _ �-mm � I � shall result in a hold on certificate of occupancy. LEGEND TREE PROTECTION NOTES WATER USE TABLE 1 . Within the drip line of any protected existing tree, there shall be no cut of fill over four -inch depth unless a _ WATER USE / \\ qualified arborist or forester has evaluated and approved the disturbance. LANDSCAPE CATEGORIES LOW MEDIUM HIGH DECIDUOUS CANOPY TREE a DECIDUOUS ORNAMENTAL TREE EVERGREEN TREE O% + + SHRUB PLANTINGS ° o PERENNIALS AND GRASSES IRRIGATED SOD 2. All protected existing trees shall be pruned to the City of Fort Collins Forestry standards. 3. Prior to and during construction, barriers shall be erected around all protected existing trees with such barriers to be of orange fencing a minimum of four feet in height, secured with metal T-posts, no closer than six feet from the trunk or one-half of the drip line, whichever is greater. There shall be no storage or movement of equipment, materiel, debris or fill within the fenced tree protection zone. 4. During construction stage of development, the applicant shall prevent the cleaning of equipment or material or the storage and disposal of waste material such as paints, oils, solvents, asphalt, concrete, motor oil or any other material harmful to the life of a tree within the drip line of any protected tree or group of trees. 5. No damaging attachment, wires, signs or permits may be fastened to any protected tree. 6. The installation of utilities, irrigation lines or any underground fixture requiring excavation deeper than six inches shall be accomplished by boring under the root system of protected existing trees at a minimum depth of twenty-four (24) inches IRRIGATED TURF SHRUB AREAS GENERAL NOTE 0 SF 4,639 SF 0 SF 7,027 SF 481 SF 0 SF AFTER AN ON -SITE MEETING WITH TIM BUCHANAN ON MAY 1 1, IT WAS DETERMINED THAT TWO SIGNFICIANT TREES SHALL BE MITIGATED FOR WITH THE LANDSCAPE PLAN. MR. BUCHANAN DETERMINED SEVEN (7) THREE-INCH (3") CALIPER TREES SHALL BE PLANTED ON -SITE TO MITIGATE THE LOSS OF THE SIGNIFI(-ANT TREES. THE THREE-INCH CALIPER TREES ARE SHOWN ON THE LANDSCAPE PLAN. 2. THE TWO HACKBERRY TREES LABELED TO BE TRANSPLANTED SHALL BE RELOCATED ON THE SENIOR CENTER PROPERTY. CALL UTILITY NOTIFICATION CENTER OF COLORADO 1-8W-922-1987 IN OR 534-67W ENVERRO CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES 77 SCALE: 1"20' N O R T H 0 10' 20' 40' PL.ANTI N G PLAN FINAL COMPLIANCE PLAN HOME STATE BANK S_ SHIELDS STREET & RAINTREE DRIVE FORT COLLI NSA COLORADO BHA DFSIGN, INC. • 48W INNOVATION DRIVE FT. coLLINS, CO 80S2S • If L. (9/0) 223 - 7577 SHEET 2 of 4 TRANSPLANTED TREES SEPTENABER 12, 2005 H -123 2439 \1-