Loading...
HomeMy WebLinkAboutWINDTRAIL TOWNHOMES PUD - Filed GC-GENERAL CORRESPONDENCE - 2005-09-02Trans rtation Services Engineering Department City of Fort Collins March 13, 1997 John McCoy The Prudential 3665 John F. Kennedy Parkway Ft. Collins, CO 80525 Dear John: This letter is being sent as a follow-up to our meeting at the Windtrail Townhomes site on Tuesday March 11 with Basil Harridan of the Stormwater Utility and Kathleen Reavis of Transportation Planning. As we discussed, attached is a sketch of the improvements to the emergency access/bike and pedestrian path that are needed. Also included are the sample specifications for concrete bollards I obtained from the Parks Department. As we agreed, you are responsible for installing two bollards at each end of the emergency accessway in the locations shown on the sketch. Bollards are typically required to restrict the general public from using emergency accessways for vehicular access while still allowing pedestrians, bicycles, and emergency vehicles to use the accessway. Since your original plan called for a portion of the width of the accessway to be constructed out of grass-crete and instead it was constructed entirely in concrete, the accessway now conflicts with an inlet on Shadowmere Court. The bollards at that end are to be placed closer to the left side to direct pedestrians and bicycles to the right. After the bollards are installed, please contact Kathleen Reavis at 221-6140 and she will issue a work order for City crews to do some striping of the path to also direct users to the right of the inlet. Since the accessway serves the development and is not part of the City's right-of-way nor bikeway system, the costs of this initial striping will be billed to you. Future maintenance of the striping and bollards shall be the responsibility of the Homeowner's Association. Please notify the appropriate representatives of the Association of this future obligation. Again, the City is not obligated for maintenance of the striping nor bollards since the accessway is not part of the City's right-of-way nor is it part of the City's formal trail system. "'I North College AVenuC • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6605 Lastly, since the sidewalk and pedestrian ramp at the north and of the accessway must be replaced due to da. ge, it was agreed that the ramp sh A be replaced in the center of the accessway (instead of aligning it directly with the ramp at the cul-de-sac on the north side) 'to facilitate the bicycle and pedestrian use of the connection from this development to the Spring Creek Trail. Thank you for your cooperation in attending to this matter as soon as possible. Please feel free to contact me at 221-6750 or Kathleen at 221-6140 with any questions. Sincerely, 040, C � Kerrie Ashbeck Civil Engineer II, Development Review cc: File Basil Harridan, Stormwater Utility Kathleen Reavis, Transportation Planning Lance Newlin, Engineering - Inspection Bob Prochnow, Windtrail Townhomes Homeowners iOLJOUS SNRUHS �� Odl hy.,,od R.dbly 'e oAu tl I IIiI � i I P �'� 7'-FIdG 0• 7-BCE3 / / . TURF _ 2{0 r AS Scmoc ECvtl.al ....... - iy EUU C Ym%. Wnnotlun P v i,L 4 ALP C t. AIPIn• 4 f/ kaor s� YOwN�P�i'. ru i, - APT RLN�UI ALS i 1 y zo0o0 s dd� Orayod . Blood '�'i ' 130 BDG AJ vqP. Ovyl• .vS E Colorado YIn4r Cr ..p.j . l'L. Y' GRAS ES t 13 I Gou, Wldm L4m Aw �1VAL IN � i `— l' CONO TE PAT" IN 70' FI LANE - (GRA88 P VERB APPROVED E=AL) TO CCI N : TO Pgd LLAjZD9 GILGALAD W R \ WINDTRAIL CN sPRiw, i `fit CREEK NF D. TO BE MAINTAINED BY ,,CC T (A)'''' PLANT NOTES (B) 1. ALL PLANT MATERIALS 5PALL BE IN ACCCRDANCE WIT" AAN _ 2 �� 9PEGIFIGdTIGN9 FOR NUMBER ONE GRADE. 2. ALL TURF A REA9 814ALL DE IRRIGATED WII" AN AUTOMATIC _-F'OF-'JP IRRIGATIGN STBTEM. J31 �-8GB 3. ALL TREES TO BE BALLED . BURLAPIxD 4. ALL 5"T e BEDS EXCEPT THOSE. NOTED 6 T"E PLAN >S '• _. -. �U/ TO BE!IT" 11,1,11 j 0nn