Loading...
HomeMy WebLinkAboutSUNSTONE TOWNHOMES PUD - Filed GC-GENERAL CORRESPONDENCE - 2005-07-19July 30, 1996 Project No: 1516-01-90 Ward Stanford City of Fort Collins Engineering Department P.O. Box 580 Ft. Collins, Colorado 80522 Re: Variance Request; Sunstone Townhomes P.U.D.; Ft. Collins, Colorado Dear Ward, This letter serves as our formal request for a variance from the "City of Fort Collins Design Criteria and Standards for Streets", dated July, 1986 for the above referenced project. More specifically, this is a request for the approval of the common driveways for the proposed townhotes located on Gemstone Lane. The width of the common driveways exceeds the maximum width for multi -family units as noted in the current design standards for streets. The driveway width also exceeds 50% of the lot frontage in several instances. The townhomes are to be constructed as 4-plex and 6-plex units. The driveways are grouped in pairs in order to access the townhomes more effectively. The depressed portion of the drive along Gemstone Lane typically extends across the front of two driveways. This was done as a matter of practicality considering the location and layout of the garages for the units. The actual driveways are typically separated by four feet (4'). * Driveway widths (variance_ requested) Item 1.02.12-b.-(1) in Section 1.02.12 on Page 18 of the "City of Fort Collins Design Criteria and Standards for Streets" indicates that multi -dwelling unit (3 or more units) driveways are acceptable in a PUD if the minimum width of a drive is twenty four feet (24') when 90 degree parking or garages are opposite each other. The New Driveway Approach Detail with Vertical Curb and Gutter (Detail D-15) indicates a maximum driveway width of twenty five feet (25') for multi -family residential. The actual driveway width considers a 16individual driveway width for each unit and a four foot (4') separation between the mair-- driveway structure. Transitioning from a depressed curb to a full height vertical curb and then back down to a depressed section in four feet (4') was deemed impractical and a potential nuisance to any driver entering or backing out of the driveway. It also would not meet City standards for driveway transition widths of six feet (6'). The total width of each driveway cut is therefore, 36' (16'+4'+16'=36'). * Driveway setback from nearest -right-of-way line _ (variance _ not requested) The Curb -Cut Standards detail for residential lots (Detail D-9) indicates a minimum setback of twenty feet (20') from the nearest lot corner or right-of-way line to the edge of driveway. This detail also indicates a maximum driveway width of 25' for multi -family residential. Lot 21 has the closest driveway to the street right-of-way. This driveway is 24' from the right-of- way line for Sunnmerstone Drive, so no variance request is made for this item. An exhibit is attached which represents Lots 21-24, Sunstone Townhomes P.U.D. for reference. The scale is 1"=20'. 4836 S. College, Suite 12 Ft. Collins, CO 80525 (970) 226-5334 FAX (970) 282-031 1 PAGE 2 Project No: 1516-01-96 July 29, 1996 Re: Variance Request; Sunstone Townhomes P.U.D.; Ft. Collins, Colorado * Driveway frontage _ (variance requested) Item 1.02.12-a.-(1) in Section 1.02.12 on Page 18 of the "City of Fort Collins Design Criteria and Standards for Streets" does not allow a driveway width to exceed 50% of the frontage of a lot, except in the case of a cul-de-sac or a flag lot. The driveways for the Sunstone Townhomes are sixteen feet (16') wide. The center two (2) Lots in the 4-plex configuration and the center four (4) units in the 6-plex configuration, have frontages of 28.1'. The driveway to lot frontage ratio is 56.94% which slightly exceeds the 50% maximum allowable frontage. A majority of all end units to both 4-plex and 6-plex configurations have greater frontages resulting in driveway to frontage ratios of less than 50%. The summary of lot frontage, drive width and drive to frontage ratio is as follows: Lot lot frontage drive width ratio 1 34.10' 16, 46.92% 2 28.10' 16' 56.94% 3 28.10' 16' 56.94% 4 36.10' 16' 44.32% 5 36.10' 16' 44.32% 6 28.10' 16' 56.94% 7 28.10' 16' 56.94% 8 28.10' 16' 56.94% 9 28.10' 16' 56.94% 10 36.10' 16' 44.32% 11 36.10' 16' 44.32% 12 28.10' 16' 56.94% 13 28.10' 16' 56.94% 14 28.10' 16' 56.94% 15 28.10' 16' 56.94% 16 36.10' 16' 44.32% 17 36.10' 16' 44.32% 18 28.10' 16, 56.94% 19 28.10' 16' 56.94% 20 31.10 16' 51.45 % 21 27.11 16' 59.02% 22 28.10' 16' 56.94% 23 28.10' 16' 56.94% 24 35.10 16' 45.58% 25 35.10 16' 45.58% 26 28.10' 16' 56.94% 27 28.10' 16' 56.94% 28 28.10' 16' 56.94% 29 28.10' 16' 56.94% 30 35.10 16' 45.58% 31 35.10 16' 45.58% 32 28.10' 16' 56.94% 33 28.10' 16' 56.94% 34 35.10 16' 45.58% PAGE 3 Project No: 1516-01-96 July 29, 1996 Re: Variance Request; Sunstone Townhomes P.U.D.; Ft. Collins, Colorado This variance request to approve 36' wide driveway cuts along Gemstone Lane has no potential damaging effects on the safety and welfare of the residents of the Sunstone Townhomes P.U.D. project, the City of Fort Collins, or the general public. If you have any questions, please call at 226-5334. Brian W. Shear, P. Shear Engineering BW S / meo attachments cc: Aletha Langham-Godwin; Mark Twain Homes Inc. Eldon Ward; Cityscape Mike Ludwig; City Planning Mike Herzig; City Engineering Transportation Services Engineering Department City of Fort Collins Brian W. Shear, P.E. Shear Engineering Corporation 4836 S. College Ave., Suite 12 Ft. Collins, CO. 80525 Re: Variance Request, Sunstone Townhomes P.U.D.; dated July 30, 1996 Dear Brian, This letter serves as a formal response to your request for variance from the "City of Fort Collins Design Criteria and Standards for Streets" manual, dated July, 1986 for the above referenced project. Each of the three variances: Driveway widths, Driveway setback from ROW, and Driveway frontage have been reviewed and are acceptable based on the overall acceptance of the project layout, as shown on the approved Site plans, by the Engineering Department management. Therefore a variance to the stated standards is formally granted for each of the three (3) variance requests stated above. Ward Stanford Civil Engineer i a.� 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6605 May 14, 1996 Project No: 1516-01-90 Ward Stanford City of Fort Collins Engineering Department P.O. Box 580 Ft. Collins, Colorado 80522 Re: Sunstone Townhomes P.U.D.; Ft. Collins, Colorado Dear Ward, The following represents our response to several utility plan review comments. Generally, this response will discuss revisions made to each utility plan sheet according to the comments made by the Engineering Department, the Stormwater Utility and Water and Sewer. A separate response letter has also been addressed to the Stormwater Utility and is attached for your reference. Sheet 1 - Cover Sheet * The General notes have been revised. The following General Note has been added: 19. The City shall not be responsible for any damage or injuries sustained in this development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage, or other damage unless such damage or injuries are sustained as a result of the City's failure to properly maintain its water, wastewater and / or storm drainage facilities in the development. * The East-West street typical section has been revised to provide a 28' wide street in a 52' right-of-way. * The final plat is being revised and will be included in the plan set. PLAT * The plat revisions had not been completed at the time of preparation of this response. We will forward the required number of copies of the plat immediately upon completion by Landstar Surveying. The plat should be available this week. The plat will be incorporated into the Final Utility Plans. Sheet 2 - Master Utility Plan * Individual unit water services have been replaced with a single water service for each building. * The stop boxes and meter vaults have been relocated behind the detached walk. The stop box is 12" inside the easement line and the meter vault is on private property. A detail has been added to Sheet 8 to define these locations. * The Master Utility Plan General Notes have been revised to not polywrap with DIP water line. * An additional gate valve has been added near the fire hydrant at the center of the North -South portion of Gemstone Lane. 4836 S. College, Suite 12 Ft. Collins, CO 80525 (970) 226-5334 FAX (970) 282-0311 PAGE 2 May 14, 1996 Project No: 1516-01-96 Re: Sunstone Townhomes P.U.D.; Ft. Collins, Colorado Sheet 2 -Master Utility Plan * Sewer service stationing has not been provided for Lots 35-41. These lots will have single family residences which may not be situated exactly as shown. Sewer and water services are expected to be installed at locations which are compatible to the final site plan for each lot. * A note concerning the adjustment of existing manhole MH # 7 was not added to this sheet. The direction for adjustment of existing manhole MH # 7 was provided on Sheet 3 with the sanitary sewer plan and profile. Sheet 3 - Sanitary and Storm Sewer Plan and Profile * The Sewer Line Plan and Profile Construction notes have been revised to indicate 60" diameter manholes. * Water line crossings have been indicated on the profile. * Concrete encasement of the storm sewer above the water line has been specified. This is for the storm sewer at the East-West portion of Gemstone Lane. * A watertight cover has been specify for proposed manhole MH A-1. * The construction note concerning the adjustment of existing manhole MH # 7 was expanded. Sheet 4 - Master Improvements Plan * The valley pan in Tract C has been deleted in its entirety. * A midblock access ramp has been added along the north side of the East-West portion of Gemstone Lane. Sheet 5 -Street Plan and Profile * All positive and negative slope designations have been reviewed and made consistent with profile design standards. * The East-West portion of Gemstone Lane has been widened to 28' with a 52' right-of-way. * A midblock access ramp has been added along the north side of the East-West portion of Gemstone Lane. * Curb return profiles have been added. Sheet 6 -Master Grading Plan * All Stormwater Utility comment have been addressed. See attache response to the Stormwater Utility. PAGE 3 May 14, 1996 Project No: 1516-01-96 Re: Sunstone Townhomes P.U.D.; Ft. Collins, Colorado Sheet 7 -Master Drainage and Erosion Control Plan * All Stormwatet Utility comment have been addressed. See attache response to the Stormwater Utility. Sheet 8 -Detail Sheet * The sewer service detail with underdrain has been replaced with a sewer service detail without underdrain. * A plan view utility coordination detail has been added. * The drop manhole detail has been updated to show the top of the sewer service equaling the top of the existing 27" sewer main. * Individual 3/4" multi -unit water services have been replaced with a single 1 1/2" water service for each building. A 1 1/2" and 2" water service detail has been added. Sheet 9 - Detail Sheet * The detail for the metal sidewalk culvert for detached walk has been revised to extend metal grate 12" either side of the detached walk. Miscellaneous * Eric Brakke has determined that an updated traffic study is not required. * This is a P.U.D. with 28' wide lots and attached townhome units. All common drivecuts have a common depressed curb. However, actual driveways are only 18' wide. No revisions to the drivecut intent have been made. Except for the final plat, this completes our response of the comments for engineering related items for Sunstone Townhomes P.U.D. If you have questions, or require further information on any item, please call at 226-5334. Sincerely, r Brian W. Shear, P.E. Shear Engineering Corporation BWS/mb cc: Aletha Langham-Godwin; Mark Twain Homes Inc. Eldon Ward; Cityscape Mike Ludwig; City Planning Roger Buffington; City water and sewer Basil Harndan; City Stormwater Utility