HomeMy WebLinkAboutSUNSTONE TOWNHOMES PUD - Filed CS-COMMENT SHEETS - 2005-07-19PROJECT -
COMMENT SHEET
City of Fort Collins
Current Planning
DATE: March 19, 1996 DEPT: Engineering - Ping
PROJECT: #57-86N Sunstone Townhomes PUD Preli-Final
PLANNER: Mike Ludwig
All comments must be received by: March 29, 1996
❑ No Problems We,,04 Try ` s
Problems or Concerns (see below or attached) or
• FINAL PLAT, SITE and LANDSCAPE PLANS 4-4 G r fa �^� •
1. Add sight distance easement and criteria notes.
2. The 30' street width w/ on -street parking requires all units to be fire sprinklered.
3. The 24' street is too narrow for this project due to the quantity of on -street
parking vs. # of units. We believe parking will take place in the 24' area affecting
safety and access.
4. Legal and Plat map do not agree.
5. Driveway curb cuts do not meet city standards, see city detail D-9.
• UTILITY PLANS
1. See all comments above.
2. Include the Plat w/ the utility plan set.
3. Slope of the land adjacent to the sides of the sidewalk to be <= 2% for min. 12"
width.
4. Check slope + / - labeling on the street profile.
5. Need a curb ramp across the street from the northwest ramp.
6. Address other minor comments throughout plan set.
Date: Signature: j
C VE
COPIES OF REVISIONS Q SITE
Cfi ANDSCAPE
U UTII,ITY