Sheet I:
`Existing conditions' mentioned on index is not included in this set.
Sheet 2 of 2 (Plat):
Two minor comments, see redlines.
Sheet 2:
Easement boundary was omitted.
Sheet 3:
Inlet 13 is not consistent with sheets 31, 33A, and A2; see redline for further comments.
Sheet 4:
Tract C is still labeled `Phase 1 % hasn't phasing been omitted?
Sheets 12 & 13:
Watch sign convention on slopes.
Sheet 31:
See redline for comments.
Sheet 33:
Section A -A of inlet 13 is incorrect
Sheet A2:
See redline for comments.
Date: / �' Signature:_���
PLEASE SEND COPIES OF MARKED REVISIONS: FLAT
(]' SITE
[� UTILITY
LANDSCAPE
Shenandoah Pud - final submittal plan review (page 3 of 4) November 12, 1996
14. A raised median needs to be provided in College Ave for the left turn into
Triangle Drive. This is needed due to the conflicts in the left turns and the
need to control the turns. A neighborhood meeting might need to be held
to let the Victoria Estates people know that their access will be limited to a
right -in right -out at this time. My calculations show that 140 feet of
storage , 485 feet of decel and 220 feet of taper is needed.
Triangle Drive
15. If a plainted median is desired additional Row needs to be dedicate to
accommodate it. The median needs to be within the row and not a
separate tract.
16. The south curb line needs to be moved over to accommodate east bound
double lefts and a right turn.
17. With the dedication of additional Row on College Ave the 2.0% for 125
feet from the intersecting Row will probably not be met with the current
design.
18. The state does not allow any additional water above historic to flow onto
the State Highway. And based on the existing topography no water was
flowing onto the highway and this needs to be maintain. Might not be
able to guarantee that without a sump condition at this intersection. This
needs to be looked at.
19. The maximum slope on any road is 8.0% . This is being exceeded here
the design needs to be reworked so this can be met.
20. There is also a sight distance problem at the intersection of Triangle Drive
and Strassburg Drive a stopping sight distance of 275 feet is not being
met. In talking with Transportation the stop control at this intersection will
be on Strassburg Drive and the private access drive.
21. The curves are not designed for the speed of a collector.
..._......___..____......._........... -..._.
Additional Comments on the Plans:
Plat-
22. The Ditch Co will need to sign the plat.
23. See comments on the Utility Plans regarding the ROW width of Triangle
Drive and Strassburg Drive.
24. The walk should be placed in the ROW along Hwy.. 287, therefor the
easements along 287 do not need to be pedestrian access and bicycle
easements. An easement is still needed on the North end where the walk
transitions from behind the wetlands to within the ROW.
25. Medians if they exist need to be within the ROW, but are to be maintained
by the Homeowners Association.
Site Plan - Take a look at utility plan comments to have an idea of areas that will
be affected.
(Continued on next page)
Shenandoah Pud - final submittal plan review (page 4 of 4) November 12, 1996
Utility Plans -
In general
26. Lots 58 thru 63 could be a part of Phase 1 if you would like since all the
street work and services will be provided with Phase 1. Showing them a
part of phase 1 does not mean that they have to be built with phase 1.
Cover Sheet
27. Correct General notes as indicated and add the following note: THE CITY
SHALL NOT BE RESPONSIBLE FOR ANY DAMAGES OR INJURIES SUSTAINED IN THIS
DEVELOPMENT AS A RESULT OF GROUNDWATER SEEPAGE, WHETHER RESULTING
FROM GROUNDWATER FLOODING, STRUCTURAL DAMAGE OR OTHER DAMAGE UNLESS
SUCH DAMAGE OR INJURIES ARE SUSTAINED AS A RESULT OF THE CITY'S FAILURE
TO PROPERLY MAINTAIN ITS WATER, WASTEWATER AND/OR STORM DRAINAGE
FACILITIES IN THE DEVELOPMENT.
28. The street x-sections should be revised as needed.
Overall Utility Plan
29, Access Drives off of Triangle Drive - a radius entrance will be allowed with a
maximum 15 foot radius and concrete to the property line.
30 All the frontage along a lot needs to be built in order for the lot to acquire a
building; permit. The current phasing does not reflect this for lot 94.
31. In what phase does the pond out along College Ave get built?
32 Show the temporary turnaround at the end of Triangle Drive.
Grading and Erosion Control Plan
33. We do not want a swale between the walk and the curb along College. If the
swale is needed it should be placed behind the walk. Street trees should be placed
between the walk and the curb.
Triangle Drive Plan and Profile
34 All the access drives need to show concrete to the property line and the radii
should be a maximum of 15 feet.
35. Need to provide a temporary turn around easement at the end of Triangle Drive.
This can be done on the Plat or can be done by separate document. Where this
road goes also needs to be addressed (as was mention before). It now appears to
be running into a future detention pond. A off -site grading easement also appears
to be needed. Provide information on how the temporary turnaround is to be built.
Is curb and gutter to be built now or after the turnaround is removed?
Egyptian Drive Plan and Profile
36. Minimum slope on cross pans is 6.0%. The two across Egyptian are not this.
Plan and Profile - General
3T There are some extreme grade breaks at the intersections in the curb returns.
38. Spot elevations need to be provide along the medians, if they are provided.
Details
39. Make changes as shown on the plans to the details.
40. Provide a midblock detached walk pedestrian ramp detail. We do not have a
standard one at this time so you will need to create one.
DATE:
PROJECT
COMMENTSHEET
DEPARTMENT:
PROJECT:
Pud - Preliminary
following are some general comments on the Shenandoah preliminary Pud:
A median can be provided on Triangle Drive at the intersection with Egyptian Drive, but the
: shown appears to be quite large, larger than we would allow.
Twenty Three (23) feet of pavement (flowline to flowline) needs to be provided on the east
of the median in Triangle Drive. This will provide a 16 foot lane for fire and 7 foot parking
e for lot 106_ Twenty Four (24) feet of pavement (flowline to flowline) needs to be provided
the west side of the median in Triangle Drive. This will allow for a right turn lane and a left
n lane, Sixteen (1.6) feet would be allowed if the traffic study indicates that a right and left lane
not needed at this intersection_
The site plan indicates that there is the potential for a `future private drive extension to retail'
ectly across from Triangle Drive. That is okay but the lanes must line up. That means that a
than must be provided in that drive of the same width as the one in Triangle Drive. I don't
)w that that is what was desired since that size of an access point would take up a lot of
An updated traffic study with numbers for the projected traffic numbers at the intersection of
yptian Drive and College Ave. The updated study is needed for the future processing of the
to Highway Access Permit and to determine what improvements to the roadway system are
Date- Signature: < ' /
DEVEt-OPMENT SERVICES 28A. NORTH COLLEGE P.O.BOX 580 FORT COLLINS, COLORADO 80522-0580
PLANNING DEPARTMENT M31221-6750
PROJECT
COMMENT SHEET
City of Fort Collins
Current Planning
DATE: I 1 !'i DEPARTMENT: E��<
PROJECT:
PLANNER
All comments must be received by:
❑ No Problems
Problems or Concerns (see below or attached)
SHENANDOAH PUD - SITE PLAN REVIEW •JANUARY 18, 199S
SITE PLAN
• THE THROUGH LANES ON VICTORIA DRIVE AND COUNTY RD 32 NEED TO LINE UP ON
BOTH SIDES. A MEDIAN MAY NOT BE FEASIBLE IN VICTORIA.
• AVONDALE ROAD HAS BEEN SHOWN AS A COLLECTOR. THE LOTS ALONG IT CAN NOT
ACCESS DIRECTLY OFF OF THE ROAD, A CIRCLE DRIVE SERVING THE LOTS NEEDS TO BE
PROVIDED.
• ALONG TRIANGLE DRIVE ALONG TRACT F A SIDEWALK SHOULD BE PROVIDED ALONG THE
STREET.
• THERE ARE EASEMENTS SHOWN ALONG HWY 267, BUT NO THE TYPICAL I S GENERAL
UTILITY EASEMENT IS NOT SHOWN.
• BUILDING 15 OF THE APARTMENT COMPLEX IS IN THE EASEMENTS ALONG HWY 267
• IT IS POSSIBLE THAT A RIGHT HAND TURN LANE WILL BE NEEDED AT VICTORIA AND CR
32_ IF THEY ARE NEEDED AN ADDITIONAL 1 2 FEET OF ROW WILL NEED TO BE
DEDICATE[) FOR THE TURN LANE. THIS IS CURRENTLY BEING EVALUATED.
(CONTINUED ON NEXT PAGE)
Date: '' Signature--
CHECK IF YOU WISH TO RECEIVE ❑ PLAT
COPIES OF REVISIONS ❑ SITE
❑ LANDSCAPE
❑ UTILITY
PROJECT
COMMENT SHEET
City of Fort Collins
Current Plannint
DATE: / 00'/ DEPT: Engineering
PROJECT:.
PLANNER:
ENGINEER: ��/ A�;CL4
No Problems
'Problems or Concerns (see below or attached)
Shenandoah Pud
Site Plan
No site plan was submitted for review
Plat
April 27, 1997
1 The plat says that all rear lot easements are to be utility and drainage except where
adjacent to open spaces. There are no open spaces defined on the plat and the utility plans
call these easement just utility easements.
2. Indicate who is to own and maintain tracts D and E.
3 Is the home owners association really going to maintain tract F7
4. Label the easements on sheet 2 also.
5 See additional comments on the plat.
Utility Plans
6. The parking, lot set back from a collector is 50 feet from the travel lane and 40 feet from
the connector/local. The current design of the parking lots do not meet this criteria.
(Continued on next page)
Date: Signature:
PLEASE SEND COPIES OF MARKED REVISIONS: PLAT
SITE
UTILITY
LANDSCAPE
Shenandoah Pud (page 2 of 3) April 27, 1997
Cover Sheet
7. The residential streets only need to have a 4 foot walk. The developer will not be
reimbursed f6r a 5 foot walk on the residential and connector streets.
8. Please provide a 5 foot walk on the Triangle Drive cross section, where it is a collector.
9. The flowline to flowline width on two of the cross sections is shown incorrectly.
Overall utility Plans
10 The walk on Strasburg in Ridgewood Hills is attached on the south side of the street. This
walk should be transitioned to a detached walk on the Shenandoah Property. Use a 60
foot radius.
I I The plat calls the rear lot easements utility and drainage easements.
12. The phasing is no longer shown on these plans. Is the project no longer being phased?
13. If there is phasing in what phase does the pond out along College Ave get built?
14. The median in Triangle Drive needs to be labeled as "median/ future left turn lane"
15. Do not provide ramps across from the driveways into the commercial area. We do not
want to encourage crossing of Triangle at these points.
Drainage Plan
16 Provide an inlet on the east side of Strasburg Drive before Triangle Drive.
17. An inlet is also needed at the nose of the median to collect the flow.
Triangle Drive Plan and Profile
18 Provide information on how the temporary turnaround is to be built. Is curb and gutter to
be built now or after the turnaround is removed?
Strasburg Drive Plan and Profile
19_ Need to indicate where the crown is and its transitions as it goes west of the median.
20. The walk is attached on the south side of Strasburg Drive in Ridgewood Hills. It needs to
transition to detached on the Shenandoah Property. Use a 60 foot radius.
Storm Sewer Plans and Profile
21. Indicate the irrigation line crossing in storm sewer line 3 profile. Where does it cross, how
deep is it and is it concrete or dirt?
Drainage Details
22. The Typical Deflector Inlet - If these are to be used they can not be considered a part of
the bikelanes. This means that the street would need to be two feet wider at the
intersection to accommodate the bike lane without use of the gutter.
23. Provide a concrete sidewalk, the grates are not acceptable for the sidewalk area. It should
be one foot wider on each side (total of 7 feet) just as a normal sidewalk culvert is.
24. Indicate what is the high water line in the irrigation channel?
25. Indicate the width of the sides of the box, is it 8 inches like the bottom?
26 Need to tall: to street maintenance about what needs to be done at the approaches to the
box to help prevent settling of the pavement next to the box. May require concrete for a
ways out from the box or maybe just a thickening of the pavement here. Will let you
know when I know anything.
General Details
27. Make changes as shown on the plans to the details.
(Continued on next page)
Shenandoah Pud (page 3 of 3) April 27, 1997
28. Provide a m:idblock detached walk pedestrian ramp detail. We do not have a standard one
at this time so you will need to create one.
State Highway Plan
29. The right turn lane should be 573 feet and then the taper.
30. The stationing goes up from 11+00 in both directions.
31. Need to show the striping for the accel lane, 960 feet plus a 220 ft taper.
32. Need to provide a cross sections of the road that shows the configuration of the lanes and
the width of the curb and gutter. For both the accel and decel lanes. Similar to what was
provide for :Fossil Creek Nursery.
PROJECT
COMMENT SHEET
City of Fort Collins
Current Planning
DATE: - -2 U- 1 l DEPT: ENGINEERING
PROJECT:��r��4� P,�1
PLANNER:t
All comments must be received by:
;R Pr Problems
Problems or Concerns (see below or attached)
Shenandoah Pud - final submittal plan review February 11, 1997
Site Plan
1. Show the raised median in College Ave - no landscaping will be in this median.
2 Indicate that the median in Triangle Drive is "median / future left turn lane" - this should
be indicated on the Landscape plan also..
3 The entire length of Triangle Drive should have detached walk.
4_ Strasburg Drive in Ridgewood Hills is a 28 foot street. Therefor Strasburg Drive on this
plan needs to be shown as a 28 foot street from the Ridgewood property line to the
intersection of Egyptian Drive.
Plat
5. Per your notes that state that the tracts are to be utility easements no buildings will be
allowed on these tracts. This is in conflict with what is being shown on the site plans.
& Indicate who is to own and maintain the tracts.
7 See comments on the plat.
Utility Plans
8. Provide a striping plan for College Ave (SH287) temporary conditions - right decel and
accel lane.
(Continued on next: page 99
Date: /i / Signature -
PLEASE SEND COPIES OF MARKED REVISIONS: PLA
UTILITY
LANDSCAPE
Shenandoah Pud - final submittal plan review (page 2 of 3) February 11, 1997
9. Provide a cross section through the medians for all three. College Ave, Triangle Drive
and Strasburg Drive. This will allow a better look at how the grades work.
Cover Sheet
10. Correct the General notes as indicated.
11. Strasburg only need to have a 4.5 foot walk. This should be the same cross section that is
used for the rest of Triangle Drive.
12. Please provide a 5 foot walk on the Triangle Drive cross section.
Overall utility Plans
13. Strasburg Drive is a 28 foot street in Ridgewood Hills, therefor Strasburg needs to be
shown as a 28 foot street from the Ridgewood Hills property line to the intersection of
Egyptian Drive. The walk on Strasburg in Ridgewood Hills is also attached on the south
side of the street. This was due to last minute conflicts with the storm sewer and light and
power. This walk should be transitioned to a detached walk on the Shenandoah Property.
14 Access Drives off of Triangle Drive - a radius entrance will be allowed with a maximum
15 foot radius and concrete to the property line.
15. All the frontage along a lot needs to be built in order for the lot to acquire a building
permit. The; current phasing does not reflect this for lot 94. This was changed on later
sheet.
16<In what phase does the pond out along College Ave get built?
17 ! The median in Triangle Drive needs to be labeled as "median/ future left turn lane"
18_ Do not provide ramps across from the driveways into the commercial area. We do not
want to encourage crossing of Triangle at these points.
19. All of Triangle Drive should have detached walk, see comments on the cover sheet.
20. Show the temporary turnaround at the end of Triangle Drive.
Grading Plan
21. The street plans show it but the grading plans do not show the off site grading that is
necessary at the end of Triangle Drive.
Drainage Plan
22. With as steep as the intersection and curb return for Triangle Drive and Strasburg Drive
are I am nov sure that the water coming down Strasburg will make it around the corner
with out crossing over to the other side (south side) of Triangle Drive. Has this been
looked at? It may not be a problem with one or two year flows, but with any major storm
may cause a problem.
Triangle Drive
23. The state does not allow any additional water above historic to flow onto the State
Highway. And based on the existing topography no water was flowing onto the highway
and this needs to be maintain. Might not be able to guarantee that without a sump
condition at: this intersection This needs to be looked at.
Triangle Drive Plan and Profile
24. The nose of the median in Triangle Drive needs to be a minimum of 20 feet behind the
flowline.
(Continued on next: page)
Shenandoah Pud - final submittal plan review (page 3 of 3) February 11, 1997
25 Provide a cross section of the road through the median, for the median area to also work
as a future turn lane the cross section needs to be work with or without the median
without major redesign needed.
26 Since there its a lot going on in the intersection of Triangle and Strasburg it might be a
good idea to provide a separate detail that has the elevations in it.
27 All the access drives need to show concrete to the property line and the radii should be a
maximum of 15 feet These radii are not indicated any place that I can find.
28 Need to provide a temporary turn around easement at the end of Triangle Drive. This can
be done on the Plat or can be done by separate document. A off -site grading easement
also appears to be needed:,�Provide information on how the temporary turnaround is to be
built. Is curb and gutter to be built now or after the turnaround is removed?
Egyptian Drive Plan and Profile
29. There are a couple of elevation conflicts on this plan.
Strasburg Drive Plan and Profile
30. Haven't shown curb returns on either this profile or Triangle Dr.
31. The nose of the median needs to be a minimum of 20 feet behind the flowline. See
Section 1.02.03.10
32. Strasburg from the Ridgewood Hills property to the intersection of Egyptian drive should
be a 28 foot. street.�fhe walk is attached on the south side of Strasburg Drive in
Ridgewood Hills. It needs to transition to detached on the Shenandoah Property.
Plan and Profile - General
33. There are some extreme grade breaks at the intersections in the curb returns.
34. Spot elevations need to be provide along the medians.
Drainage Details
35. ; The Typical Deflector Inlet - We need to discuss this. If these are to be used they can not
'—' be considered a part of the bikelanes. This means that the bike lanes at the intersection
would need to be 8 feet and then could transition down to 6 feet once past the inlets. I
also need to talk to the State about this. Tess will be here at the end of the month and I
can discuss with her then as to if your design is acceptable to them.
General Details
36. Make changes as shown on the plans to the details.
Provide a midblock detached walk pedestrian ramp detail We do not have a standard one
at this time so you will need to create one.
State Highway Plan
38. The plans you have provided are fine for the future improvements. Need to provide a plan
that shows the striping for the right decel and accel lanes and the raised median.
39. As per our ;meeting the raised median should be. 140 feet of storage , 485 feet of decel
and 220 feet of taper. The median shall end at least 100 feet to the south of the southern
edge of Victoria Drive.
PROJECT
COMMENT SHEET
City of Fort Collins
mmg��
Current Planning
DATE: Aber 15, 1996 DEPT: Engineering
PROJECT: #47-95A Shenandoah PUD 1 st Filing Final
PLANNER: Steve Olt
All comments must be received by: Monday, November 11, 1996
Shenandoah Pud -final submittal plan review (page 1 of 4) November 12, 1996
The Following items need to be addressed/ provided and reviewed by City staff
for acceptability prior to this project proceeding to a Final P and Z hearing:
1. The Plat will needed to be updated to reflect the changes on the plans.
2. The Site Plan will need to be updated to reflect the changes on the plans.
3. Provide a signing and stripping plan for Triangle Drive and Strassburg.
4. A plan and profile of College Ave is needed. This should include the
design for the right turn lane and the left bay median. College needs to
be designed for three travel lanes and a right turn lane north of Triangle.
The City does not typically require an acceleration lane, but the state
sometimes does. I will be checking with the state to determine if an
acceleration lane is needed south of Triangle Drive, if so this will need to
be designed and additional row provided for this and built. The
construction of the right turn lane could probably be delayed. To do so
money would have to be put up by the developer for the construction of
these improvements in the future and plans would need to be provided
showing both phases of work, as a right turn lane would need to be
striped onto the existing shoulder and the placement and location of
ramps would probably change with the phases.
(Continued on next page)
r
Date: I/A Signaturer�, �
T /CHECK IF YOU WISH TO RECEIVE ❑ PLAT
COPIES OF REVISIONS ❑ SITE
❑ LANDSCAPE
❑ UTILITY
Shenandoah Pud - final submittal plan review (page 2 of 4) November 12, 1996
5. What happens to Triangle Drive when it goes onto the Ridgewood hills
properliy? There overall plan doesn't account for this it appears it just
goes into the detention pond. Will this be worked out? This is a good
connection and needed.
6. Twelve (12) feet of Row needs to be dedicated off -site to the North, a
distance adequate to accommodate the right turn lane requirements.
7. Seventy two (72) feet of half Row needs to be dedicated on College (287)
North of Triangle Drive ( this is the 60 foot half width plus 12 feet for right
turn lane).
8. Triangle Road should have a x-section that has 4 lanes (two lefts and a
right exiting the site and a lane entering), and bike lanes. If a median is
desired it can be provided additional Row will just need to be provided for
it. A double left should be designed at this intersection and one of the
lefts stripped out until it is needed. For the traffic volume 240 feet of
storage and 130 feet of taper is needed. May want to talk to
Transportation about this since this is an unopposed intersection.
9. Sidewalk needs to be placed along the back of the Row.
10. The OIDP shows Strassburg as a collector street. In conversations with
Mike Herzig and Eric Bracke Strassburg can be designed as a connector
street (new standards - 57 feet ROW and 36 feet pavement) IF: A
connector is also provided to the south to Avondale Road (ie. Triangle
Drive into Ridgewood Hills also at 57 feet row and 36 feet of pavement)
instead of a collector street(old standards - 68 feet ROW and 50 feet
pavement). Currently a connection is shown on the Shenandoah plans,
but is not accounted for on the Ridgewood Hills plans. Therefore the
Developers of Ridgewood Hills and Shenandoah need to work together to
determine the x-section and Row needed on Strassburg.
11. A raised median needs to be provided in College Ave for the left turn into
Triangle Drive. This is needed due to the conflicts in the left turns and the
need to control the turns. A neighborhood meeting might need to be held
to let the Victoria Estates people know that their access will be limited to a
right -in right -out at this time.
12. The Strassburg Triangle intersection additional pavement needs to be
provided on Strassburg. On the east side of the median a minimum of 24
feet is needed, this would provide for a right turn lane, and a left turn lane.
This may vary based on what the cross section of Strassburg ends up
being.
13. We want to see some sort of traffic #'s to verify the location of the day
cares driveway in relation to the intersection.
(Continued on next page)