Loading...
HomeMy WebLinkAboutHARRISONS ADDITION BLOCK 95 318 WEST MYRTLE TOWNHOMES - Filed GC-GENERAL CORRESPONDENCE - 2010-06-03Plannina Obiectives 318 W. Myrtle Town homes The 318 West Myrtle Townhome project consists of the redevelopment of a large, underutilized site containing an historic single family home and an existing non -historic small single family home. The existing historic single family home will be refurbished, (not formally included in this proposal), and a non historic home will be remodeled and four new townhomes will be constructed on the site. Foremost, this project meets City Plan Policies and Principles in the following ways. The redevelopment and improvements made to this underdeveloped site will meet overall city objectives to encourage well -designed in -fill development in keeping with the existing neighborhood. The site is within the Transit Oriented Development Overlay Zone, (TOD). The close proximity of this site to the TOD makes it an ideal project to help further the city's goal to encourage different modes of transportation reducing vehicle miles of travel (VMT). This renovation and expansion project has the added attractive feature of being an integral part of a walk able community to activity centers such as Downtown Fort Collins and Colorado State University. This infill development also meets the planning objective of encouraging compact development and has been designed to provide connectivity through walkways, courtyards, patios and porches in keeping with the character of the existing neighborhood. The site design contributes to the public realm, yet creates privacy for the residents. The alley is no longer featured as the major pedestrian walk -way between a large scale office building to the east and the existing site. Rather, the concept of connectivity guides residents and visitors through an appropriately human —scaled walk -way featuring landscaped areas and well proportioned buildings in keeping with the existing historic vernacular. The proposed remodeled facade on Myrtle Street emphasizes a traditional wrap -around porch addressing the varied streetscape to create balance with the existing more historic building. The rationale behind the assumptions made in the preliminary design of this project includes our continued focus as owners and developers towards re -development and infill opportunities in unique and positive neighborhood environments. City Structure Plan encourages designing and developing in dynamic and creative ways which respect the character of the neighborhood. This objective is met by the emphasis upon creative configuration and placement of the individual townhome units to highlight compatible massing, (limited spans), balance of major elements, overall form of the buildings (offsets), line (roof slopes), texture and pattern (siding and window proportions). The proposed eaves are lower than contemporary residential plate heights; again, emphasizing relationships to the height and scale of the existing architectural vernacular. The selection of materials and construction techniques focus upon the issues of sustainability including slab -on- grade stained concrete floors providing mass for passive solar benefits of southern oriented living spaces. Open beams ceilings feature re -cycled wood to create a loft -like interior feel. Energy conservation is important in the overall approach to specific construction techniques and materials utilized in this project. This property has been owned by the same family for the better part of the last sixty-five years and has been deserving of added attention and investment. As the new owners, intend to maintain the property and to help to restore and respect its potential contribution to the neighborhood. STAFF PROJECT REVIEW City of Fort Collins Bruce M. Froseth & Susan Kreul/Froseth Date: 2/24/2009 524 Spring Canyon Court Fort Collins, CO 80525 Staff has reviewed your submittal for 318 WEST MYRTLE TOWNHOMES, PROJECT DEVELOPMENT PLAN (PDP) - TYPE 1, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Steve Olt Topic: Electric Utility Number: 18 Created: 2/24/2009 [2/24/09] Justin Fields of Light & Power (224-6150) indicated that each dwelling unit must be individually metered. Department: Current Planning Topic: Fire Number: 13 [2/20/09] No comments. Department: Current Planning Topic: General Issue Contact: Dana Leavitt Created: 2/20/2009 Issue Contact: Steve Olt Number: 17 Created: 2/24/2009 [2/24/09] Comcast Cable TV indicated that they need a 5' wide utility easement outside of the alley right-of-way. The developer will need to provide a 1" conduit from each home to the Comcast facility. Number: 19 Created: 2/24/2009 [2/24/09] Dana Leavitt, the City's Environmental Planner, indicated that the applicant should minimize materials going to the landfill during demolition. Number: 20 Created: 2/24/2009 [2/24/09] The request for Modifications of Standards for the front yard and side yard setbacks do apply because the applicant is adding a second story to the existing structure at 318 West Myrtle Street. Number: 21 Created: 2/24/2009 [2/24/09] The proposed new front yard setback (I F-9") for the existing structure at 318 West Myrtle Street must be shown on the Site Plan. Page 1 Number: 22 Created: 2/24/2009 [2/24/09] City staff had indicated at staff review on Wednesday, February 18th that the project did not have to go through another round of review before scheduling the administrative public hearing; however, several departments (Engineering, Water/Wastewater, Stormwater, Historic Preservation, and Zoning) had comments that need to be addressed before scheduling the hearing. Peter Barnes' Zoning comments are the most significant and must be addressed to his satisfaction prior to scheduling the hearing. Department: Engineering Issue Contact: Marc Virata Topic: Engineering Number: 8 Created: 2/17/2009 [2/17/09] Is the overhead utility line along the east side of the property proposing to remain or be removed? The drawings don't appear to show the existing overhead, which seems to imply it is to be removed. If this is the case, please indicate this on the plan set. If it is proposed to remain, please show it on the plans and provide conduit for future undergrounding. Number: 9 Created: 2/17/2009 [2/17/09] The drawings seem to imply that the alley is of a consistent pavement width along the frontage, though the pavement width is not consistent along the east side of the property. Will the alley remain untouched or will some work occur (in conjunction with any potential undergrounding of the overhead)? The drawings should reflect the condition on the width of the alley upon completion of the project. Number: 10 Created: 2/17/2009 [2/17/09] The level of detail on the utility drawing set is less than a typical utility plan set. I will defer to Stormwater and Water/Wastewater as to whether the information provided is sufficient, with the exception of the following concerns: - The utility plan set will need to be a separate set from the site plan. - The utility plan set will need to have City signature blocks added to all sheets. - Please add a detail for the curb and gutter (Larimer County Urban Area Street Standards detail #701). - Should other departments require that the utility plan set be prepared by a professional engineer, more information will need to be added. - The owner's certification and director of planning signature blocks should be removed from the utility plan set. They belong on the Site Plan. - Ideally the utility plan set should be showing the existing water line on Myrtle to show the approximate extent of the patching on Myrtle that's needed. Page 2 Please add two vertical control benchmarks in accordance with City benchmark datum to help in verifying the elevations on the plan set. Please add a note on the plan set indicating that all existing substandard curb, gutter and sidewalk as well as curb, gutter and sidewalk damaged during the course of construction are required to be replaced in accordance with City standards. Number: 14 Created: 2/20/2009 [2/20/09] The developer requested a contact person for Qwest. Bill Johnson at 970 377- 6401 (bpjohn2@qwest.com) has been the contact we've regularly used. Number: 15 Created: 2/20/2009 [2/20/09] I just noticed on the landscape plan that the trash enclosure detail shows swinging doors which would swing out into the right-of-way and would not be permitted. Please use either a sliding door system or (if possible) reorient the trash enclosure in a manner that prevents swinging doors from entering the right-of-way. Number: 16 Created: 2/20/2009 [2/20/09] Upon verification on revised drawings for ID #8 and #15, the project would be ready fro a hearing from Engineering's perspective. The remaining comments can be addressed at the time of final plan review. Department: Light & Power Issue Contact: Doug Martine Topic: Electric Utility Number: 1 Created: 2/2/2009 [2/2/09] It is assumed that the house at 320 W. Myrtle will remain a single family residence. It is also assumed that the 318 West Myrtle Townhomes will each have an electric service not to exceed 125 amps, and will NOT use electric space heating. The developer will then need to provide an off -site easement across the rear of the property at 516 Meldrum. If these assumptions are not correct, a new electric transformer will be required near the corner of the alley and Myrtle. Normal electric development and system modification charges will apply, as well as costs to obtain the off -site easement. Please coordinate power requirements with Light & Power Engineering at 221-6700. Department: PFA Issue Contact: Carie Dann Topic: Fire Number: 12 Created: 2/19/2009 Thank you for responding to the Conceptual Review comments. PFA has no additional comments or concerns at this time. Page 3 Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque Topic: Stormwater Number: 11 Created: 2/19/2009 [2/19/09] A more detailed grading plan needs to be submitted for review to determine if the site will drain properly and without negatively affecting neighboring properties. The datum used needs to be clarified on the plans. If the datum is not an official City of Fort Collins datum, than please provide a note stating such. Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: Water/Wastewater Number: 6 Created: 2/17/2009 [2/17/09] Is the sewer service shown extending to 318 the existing service? If yes, will it be re -used for the 5-plex? Number: 7 Created: 2/17/2009 [2/17/09] Provide information on fire sprinkler system so that determination can be made regarding fire line/domestic water service requirements. Add notes regarding the abandonment on the existing 3/4-inch water service. The service must be abandoned at the main. If coordinated with the new 1-inch service, this work can be done at the same time that the new 1-inch service tap is installed. Department: Zoning Issue Contact: Peter Barnes Topic: Zoning Number: 2 Created: 2/6/2009 [2/6/09] The drive aisle width in the parking lot needs to be 24' per Section 3.2.2(L). Number: 3 Created: 2/6/2009 [2/6/09] Need one deciduous tree per every 40' lineal feet of the parking lot perimeter landscape strip. Also need a 6' tall privacy fence along the north and west lot lines abutting the parking lot (Sec. 3.2.1(E)(4)). Number: 4 Created: 2/6/2009 [2/6/09] Please show all the cantilevers on the Site Plan. Number: 5 Created: 2/6/2009 [2/6/09] Please show the building footprint dimensions on the Site Plan. A "formal" re -submittal of the PDP documentation is not needed prior to the required administrative public hearing. However, there are several issues that must be addressed with the appropriate City department before the hearing can be scheduled. Be sure and return all red -lined plans when you submit the required Final Plan documentation for staff review after the public hearing is held. Page 4 If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at 221-6341. Yours Truly, h)e� Steve Olt City Planner cc: Marc Virata Current Planning file #5-09 Page 5 Transportation Development Review Fee Date Received/ Paid V Total Amount Paid aead iiA Citvof Fort Collins Project Name: 318 U) . HY�',_7TA" ��1 Project Location: R3 - , . - _i-tom S= - Date: • Z •�9 Type of Submittal Please indicate the type of application submitted by checking the box preceding the appropriate request(s). Fee structure amount due ❑ Overall Developnient Plan (ODP) $500 each ❑ Final Development Plan (FDP) This fee includes 2 rounds of review $1000 each ❑ Additional round of review $ 500 each ❑ Annexation $20 x acres = + $250 = ❑ Minor Amendment $250 each ❑ Major Amendment $2,500 each ❑ Re -zone $200 each ❑ Modification to Land Use Code $200 each ❑ Wireless Telecommunication Equipment (WTE) $65 each ❑ Road Projects acres (of roadway) X $250 = ❑ Vacation of Easement(s) ** * # of vacations _ X $400 = ❑ Vacation of Right(s)-of--Way *** # of vacations _ X $800 = ❑ Dedication ofEasement(s) and/or Right(s)-of--Way *** # of dedications X $250 = *** This fee does not include the cost of filing fees. Filing fees shall be determined at the time of final document submittal and will be required prior to filing. ❑ Project Development Plan (PDP) or Basic Development Review Project requiring Transportation Services Review and/or utility plan review. This fee includes 3 rounds of review. Detached Single Family $160 per unit # of units X $160 = Multifamily or other residential units $115 per unit # of units X $115 = Commercial, Industrial, Retail, and/or Non residential building square footage $0.25 per square foot sgftX$0.25= Size of the development (area being platted or if not being platted size of parcel accompanying all development improvements) $250 per acre acres X $ 250 = Project fee $2,000 each Total of above amounts If this fee amount exceeds $30,000 then the fee amount shall be adjusted with the following formula: $30,000 +'h (the amount over 30,000 ) _ The maximum fee for any residential ONLY project shall be $500 per residential unit. This check should be used to verify the fee amount (does not apply to mixed -use developments). PDP fee shall be the lesser of this amount or the ve calculated amount. �j�#of residential units X $500 = 20� Reduction for affordable housing — a copy of the City letter certifying/ authorizing the affordable housing shall be provided with this application. Amount of reduction to be applied Total owed for PDP $ Land Use Information: Total number of single family detached units: Total number of multifamily/other residential units: Total number of certified affordable dwelling units (a copy of the letter/ authorization is required): (_ Non residential building square footage: �_ sq ft Gross Acreage: . 33 acres General Information: Owners Name(s): .6 Sul ,A Street address: City/State/Zip: &- GALL/4) S . CO 1��r7 Telephone: Fax: Applicants/ Consultants Firm Name: L Contact: Street address: City/State/ Zip: O Telephone: Fax: Certification: By signing this permit I acknowledge that I am acting with the knowledge, consent, and authority of the owners of the property (including all owners having legal or equitable interest in the real property, as defined in Section 1-2 of the City Code; and including common areas legally connected to or associated with the property which is the subject of this application) without whose consent and authority the requested action could not lawfully be accomplished. Pursuant to said authority, I hereby permit City officials to enter upon the property for purposes of inspection. Name (ple print).. 3� M FIZZ 1/215z"' • Signature Telephone: 62EO -% cc: Christie White, Engineering Development Review Engineering .... - _ ......... ._ ._ Marc Viratata 318 w myrtle townhome Page 1 From: Ward Stanford To: Dev Rev Date: 1/30/2009 5:07:16 PM Subject: 318 w myrtle townhome The motorized vehicle portion of the TIS has been waived. Page 1 of 2 Steve Olt - public hearing From: BRUCE M FROSETH <brucefroseth@msn.com> To: steve Olt <solt@fcgov.com> Date: 3/9/2009 1:44 PM Subject: public hearing Steve, I have met with or had conversation with most of the departments citing some concerns about the project. I have listed the departments and the action below: Engineering Number: 8 I have met with Bill Johnson w/ Qwest and we have a plan for undergrounding the existing overhead lines. They will be shown on the final submittal. Number: 9- I had Intermill Land Surveying locate all property corners and their city of Fort Collins bench marks for each corner. Alley widths will be show on the final submittal. Number: 10-Plans will be separated for the final submittal. All information required will be added or deleted per Engineering's request. Number: 15- The trash enclosure will be redesign to take the door swings out of the right -a -way. Water/Waste Water Number: 6- The building will use the existing 318 sewer service for the new building. Number: 7- I was provided with water flows by the fire department after the conceptual review. I have given this data to Front Range Fire Protection and they have designed a NFPA 13R system for the project. Their calculations show a 1 1/2" water line will handle the project. Front Range is now installing a similar system for Spanger construction on 700-800 E. Myrtle. On E. Myrtle they used one tap for the sprinkler and domestic water. If the design needs to be approved I can supply this information with the final submittal. Stormwater Number: 11- I met with Wes Lamarque and showed him how the proposed drainage would work. I had to raise the finish floor elevation on the four new units by 6" in order to achieve acceptable drainage. Historic Preservation Sue and I met with Karen McWilliams to discuss the plans. We agreed to add some detail to the west elevation of unit 5. Karen was supportive of not having a fence on our west property line and I will take that up with Peter Barnes before our final submittal. Zonin4 Number: 2- The drive aisle will be 24'. Peter acknowledged that the on line version of the LUC is not current since this change was made over two years ago. We will comply with the newer version. Number: 3- landscaping requirements will be shown on the final submittal. I need to have one more conversation with Peter on the fence issue but if required I will provide the fence. Number : 4,5 Site plan dimensions and cantilevers will be shown on the final submittal. If you know of something or know a department which still has concerns please let me know. Thanks brucefroseth file://C:\Documents and Settings\solt\Local Settings\Temp\GW}00001.HTM 3/9/2009 City Of CONCEPTUAL REVIEW Fort Collins STAFF COMMENTS ITEM: Proposed remodel of the dwelling unit at 318 W. Myrtle plus addition of three attached dwelling units on the lot at 318 and 320 W. Myrtle St.. * New proposal contains an additional attached unit. MEETING DATE: July 28, 2008 APPLICANT: Bruce Froseth Susan Kreul-Froseth 524 Spring Canyon Ct. Fort Collins, CO 80525 brucefroseth(a)-msn.com archfro(aD-earthlink. net LAND USE DATA: The property is located on north side of West Myrtle Street between South Meldrum Street and South Howes Street, adjacent to the north - south alley. There are two dwelling units on the property and a garage that is proposed to be demolished. COMMENTS: The following departmental agencies have offered comments for this proposal based on a sketch plan and project narrative which were presented to the review team: ZONING Contact Info: Peter Barnes, 416-2356, pbarnes(a fcgov.com 1. The property is located in the NCB — Neighborhood Conservation Buffer zone district. Information about this zone district can be found online at: hftp://www.colocode.com/ftcollins/landuse/article4.htm#div4d9. 2. Multi -family dwelling units located within a street -fronting principal building are permitted residential uses in this zone, subject to Administrative (Type 1) review and public hearing approval. The proposed three new dwelling units need to be attached to the existing dwelling unit at 318 W. Myrtle in order to comply with the "street - fronting principal building" requirement. *The new dwellings are attached 3. This property is also located in the Transit Oriented Development (TOD) Overlay zone district. Information about this district can be found online at: hftp://www.colocode.com/ftcollins/landuse/article3.htm#div3dl 0. 2 City Of CONCEPTUAL REVIEW Fort Collins STAFF COMMENTS Off-street parking or residential uses is not required in the TOD Overlay zone district; however, off-street parking is highly recommended in this area. *There are eight off street parking spaces which includes a hadicaped space. 5. Minimum lot area shall be equivalent to the total floor area of the building(s), but not less than five thousand (5,000) square feet for each principal building. *Lot area is 14,250 square feet and finished square footage of new and existing buildings total 6,310 square feet. 6. Lots are subject to a maximum FAR of thirty-three hundredths (0.33) on the rear fifty (50) percent of the lot. * rear of lot allows 2,375 S.F. proposed is 2,156 7. Minimum lot width shall be forty (40) feet for each single-family and two-family dwelling and fifty (50) feet for each other use. If more than one (1) principal building is proposed to be constructed side -by -side on the same lot, then each such principal building must have at least forty (40) feet of street frontage for single-family and two-family dwellings, and at least fifty (50) feet of street frontage for each other use. *The lot has 95 feet of frontage and 90 feet is required 8. Minimum front yard setback shall be fifteen (15) feet * The existing principal building is 7'-9" off of property line. The .remodel of 318 W. Myrtle will add another 4'-0" of set back. 9. Minimum rear yard setback shall be five (5) feet from existing alley and fifteen (15) feet in all other conditions. *The proposal meets requirements 10. Minimum side yard width shall be five (5) feet for all interior side yards. Whenever any portion of a wall or building exceeds eighteen (18) feet in height, such portion of the wall or building shall be set back from the interior side lot line an additional one (1) foot, beyond the minimum required, for each two (2) feet or fraction thereof of wall or building height that exceeds eighteen (18) feet in height. *The existing principal building is 1.5 feet off side setback. All new construction conforms to side setbacks and height restrictions. A modification to standards is submitted. 11. Maximum building height shall be three (3) stories. *meets requirements, low eave heights are planned and are less than a typical two story eave height. 12. A modification to the minimum side yard width standard will need to be requested if the remodeled dwelling unit at 318 W. Myrtle does not comply with minimum side yard requirements. * Modification is submitted within. 13. Parking lot perimeter and interior landscaping will be required per Section 3.2.2 of the Land Use Code. * See landscape drawing 3 City of CONCEPTUAL REVIEW Fort Collins STAFF COMMENTS ATER UTILITY Contact Info: Glen Schlueter, 224-6065, gschlueter(&-fcgov.com 1. The amount of new impervious area will affect the Stormwater "new development fee" and the submittal requirements for redevelopment. The existing impervious areas are grandfathered; therefore, documentation is needed with a site plan showing existing and proposed impervious areas along with a table listing each area and showing the final amount of new imperviousness. *Table is included on drawings and as a separate submittal item 2. In the Old Town drainage basin, a drainage and erosion control report and construction plans are required if there is an increase in imperviousness greater than 5000 square feet. These must be prepared by a Professional Engineer registered in Colorado. *The new impervious area is less than 5000 S.F. 3. If there is an increase in imperviousness greater than 5000 square feet, onsite detention is required with a 2 year historic release rate for water quantity. Parking lot detention for water quantity is allowed as long as it is not deeper than one foot. Water quality treatment is encouraged as described in the Urban Storm Drainage Criteria Manual, Volume 3 — Best Management Practices (BMPs). However, this site does drain to the Udall Natural Area which does treat the runoff so there is not a requirement for onsite wfater quality treatment. If there are less than 5000 but more than 350 square feet of new imperviousness, a site grading plan is all that is required. *New grading plan is part of site plan 4. There is a storm sewer in Myrtle should there be a need for a deeper outlet than the street or alley. 5. The design of this site must conform to the drainage basin design of the Old Town Master Drainage Plan as well the City's Design Criteria and Construction standards. 6. The city wide development fee is $4,420/acre ($0.1015/sq.ft.) for new impervious area over 350 sq.ft. No fee is charged for existing impervious area. This fee is to be paid at the time each building permit is issued. WATER & WASTEWATER Contact Info: Roger Buffington, 221-6854, rbuffingtonCEMcgov.com 1. Existing mains: 4-inch water main in Myrtle; 8-inch sanitary sewer in alley east of site. *The sanitary service for 318 W. Mytle will service the additional units. 2. The two existing residences on the property each have a 3/-inch water service. A 3/-inch service for a 4-plex may be marginal. Provide service sizing calculations. *There will be a new 1" service from Myrtle St. 4 City of CONCEPTUAL REVIEW Fort Collins STAFF COMMENTS 3. s and water rights will be due at building permit. More information about these fees can be found online at hfp://fcgov.com/utilities/rates-fees.php. POUDRE FIRE AUTHORITY Contact Info: Carle Dann, 416-2869, cdann(a-poudre-fire.org 1. ADDRESS NUMERALS Address numerals shall be visible from the street fronting the property, and posted with a minimum of 6 inch numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). An address kiosk would be helpful for non -street fronting dwelling units. 97UFC901.4.4 *Numerals will be six inches 2. WATER SUPPLY Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum requirements include: • Residential: 1,500 gpm (a flow test should be conducted to determine if the existing hydrant at Myrtle/Meldrum can adequately serve the property) These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. 97UFC 901.2.2.2 * Flows in the area are adequate for this type of development 3. AUTOMATIC FIRE SPRINLKERS Automatic Fire Sprinklers may be required with the adoption of a new Fire Code for any residential project with more than 2 dwelling units. Please contact Care for current code requirements and information about when the new code may be adopted. * Automatic fire sprinklers will be installed ENVIRONMENTAL PLANNING Contact Info: Dana Leavitt, 221-6143, dleavitt(&_fcgov.com 1. Please contact Tim Buchanan, City Forester, at 221-6361 for an evaluation of the trees on the property. Existing trees that are deemed significant will need to be protected or if they are removed, they will need to be replaced with mitigation trees. *A site visit with Tim Buchanan has occurred and all trees were considered insignificant and not worth saving. A large elm will remain at the entrance to the new parking area. An Existing Locust tree In the front will remain. 5 City of CONCEPTUAL REVIEW Fort Collins STAFF COMMENTS /0000��Trash enclosures should be designed to be compatible with the building architecture and should be large enough to accommodate recycling services. * A trash/recycling center will be provided adjacent to an existing trash area for the property north of this site 3. Please contact Dana for information about Green Building programs and services offered by the City. ELECTRIC UTILITY Contact Info: Bruce Vogel, 221-6700, utilitiesCc)-fcgov.com The existing transformer located at the corner of Myrtle and Meldrum Streets may be adequate to carry the load for this proposal. If not, a larger transformer will be required and the developer is responsible for the cost of replacement. Normal Development Fees and System Modification charges may apply and more information about these fees can be found online at http://fcgov.com/utilities/rates-fees.php. Please contact Doug Martine at 224-6152 to discuss development charges and service requirements. * An existing transformer across the alley @ the North East corner of the lot will service the sift . A utility easement will be required from the property directly north of this lot. ENGINEERING Contact Info: Randy Maitland, 221-6605, rmaizlanda-fcgov.com 1. Larimer County Road Impact Fees and Street Oversizing Fees for this project will apply and be due at the time of building permit. Please contact Matt Baker (970-224-6108) if you have questions about the Street Oversizing Fees. 2. Transportation Development Review Fees (TDRF) will apply to this project and are due at the time of submittal. For more information, visit http://fcgov.com/engineering/dev-review_php. 3. A Transportation Impact Study (TIS) may need to be submitted with this project. Please contact Traffic Operations (Joe Olson or Ward Stanford) at 221-6630 to discuss TIS requirements and/or to schedule a scoping meeting. 4. This project will need to prepare and submit utility plans. 5. The City will enter into a development agreement with the developer for this project. 9 City Of CONCEPTUAL REVIEW Fort Collins STAFF COMMENTS . of any utility or grading work on the site a 10000Development Construction Permit (DCP) may need to be issued. This permit is issued by Engineering. 7. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets, sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 8. The project shall be designed in accordance with the Larimer County Urban Area Street Standards (as applicable). The Larimer County Urban Area Street Standards can be found online at: http://www.larimer.org/engineering/GMARdStds/UrbanSt.htm. 9. The existing concrete driveway on Myrtle Street will need to be reconstructed or closed. *It will be closed to enhance the overall streetscape and add an additional five parking spaces to the street parking. 10. If the alley needs to be significantly cut and trenched for new utility service connections, the alley may need to be fully reconstructed with an approved, engineered design that works with the alley to the north. *Power has existing sleeves under the alley. No disturbance is planned in the alley pavement. HISTORIC PRESERVATION Contact Info: Alyson McGee, 221-6597, amcgee@fcgov.com 1. In February 2007 it was determined that the dwelling unit located at 318 W. Myrtle St. is not individually eligible for historic landmark designation. The house located at 320 W. Myrtle St. was determined to be individually eligible for local landmark designation. A determination has not been made for the garage at 318 W. Myrtle St., so the applicant will need to submit photos of all 4 sides of the structure for a determination of eligibility before the structure can be demolished. *There are no physical changes planned at this time for 320 W. Myrtle. Photos of the garage are part of this submittal. 2. Section 3.4.7 of the Land Use Code calls for the development plan and building design to protect and enhance the historic and architectural value of any historic property adjacent to the site. Please work with Historic Preservation staff to design the new structures in a character that complements the existing historic structures. Financial assistance may be available for renovations if you choose to designate the house at 320 W. Myrtle St. *The new structures complement the existing structure @ 320 W. Myrtle in the following manner: 7 City of CONCEPTUAL REVIEW F6rt TAFF COMMENTS Collinsn -mag�to the existing house @320 Myrtle er to 1 '/2 story eave heights on new buildings -massing consistent W/ existing house -siding materials relates to existing material and textures -window proportions repeated/patterns matching existing PLANNING Contact Info: Shelby Sommer, 416-2138, ssommere-fcgov.com 1. For a step-by-step guide to the Development Review process, please visit the Development Review Guide online at: http://fcgov.com/drg. 2. You will be required to submit a Project Development Plan (PDP) for the City to review. This PDP will be evaluated through the Development Review Process. City of Fort Collins Departments along with other external agencies will have the opportunity to review and comment on your Project Development Plan. 3. A decision (approval, approval with conditions or denial) will be made by the City's Administrative Hearing Officer following an Administrative Public Hearing (Type One Review). If your Project Development Plan is approved at the Public Hearing, you will be required to submit Final Plans for review which will ultimately be recorded. 4. Please be aware that you will owe both the Transportation Development Review Fee (TDRF) and the Development Review Fee with your application submittal. You will follow the Small Project Fee schedule for your Development Review Fee, found on Page 2 of the Development Review Fee Schedule online at hftp://fcqov.com/currentplanning�/Ssubmiftals.php. A final development review fee of $1000 will be charged when final plans are submitted after the public hearing. A final Transportation Development Review Fee of $1000 will also be charged when final plans are submitted after the public hearing. 5. Your Project Development Plan will be evaluated per the standards set forth in the Land Use Code (LUC) and the Latimer County Urban Area Sheet Standards (LCUASS). 6. The entire Fort Collins Land Use Code is available for your review on the web at hftp://www.colocode.com/ftcollins/landuse/begin.htm. 7. The Latimer County Urban Area Street Standards are online at hftp://www.larimer.o[g/engineering/GMARdStds/UrbanSt.htm. I City of CONCEPTUAL REVIEW FortTAFF COMMENTS Collinsolu0ns his development proposal is subject to all applicable standards of the Fort Collins Land Use Code, specifically, but not limited to: • Section 3.2.1 - Landscaping and Tree Protection • Section 3.2.2 - Access, Circulation and Parking • Division 3.5 — Building Standards (including project compatibility) • Division 3.3 - Engineering Standards • Division 4.9 — Neighborhood Conservation Buffer District 9. Please pay particular attention to the parking lot layout and landscaping requirements. All parking stalls, drive aisles and setbacks will need to conform to the standards in Section 3.2.2 of the Land Use code. 10. A walkway will be required to connect the street sidewalk to all dwelling unit entrances. 11. Application forms and PDP submittal requirement checklists can be found online at http://fcqov.com/currentplanning/submiftals.php. 12. Please contact me if you have questions about speck submittal requirements. 13. Information about Utility Development Fees and Charges can be found online at hilp://fc-gov.com/utilities/rates-fees.php. 14. Information about Building Permit Fees and the Permitting Process can be found online at http://fcoov.com/nbs/?departments. 15. A neighborhood meeting is not required for Type 1 (Administrative) proposals. I suggest that you discuss your proposal with your immediate neighbors prior to submitting your development plan for review. If you would like to hold a neighborhood meeting please contact me to coordinate the meeting logistics. 16. When you are ready to submit your application to the City for review, please schedule a PDP submittal appointment at the Development Review Center at 221-6760. Q