HomeMy WebLinkAboutBANKCENTER SQUARE LOT 1 - Filed MA-MINOR AMENDMENT - 2010-03-11 (2)NITY MAP
GENERAL NOTES
WNE
TIFICATE
1 SITE SURVEY LEG
Q
POST
OT
TELEPHONE PEDESTAL
Q
CLEANOUT
'Cf
FIRE HYDRANT
IRRIGATION TIMER
U4�3
ELECTRIC BOX
0
GAS METER
Q
SANITARY MANHOLE
®
ELECTRIC VAULT
®
GAS METER
HANDICAP PARKING
OO
FOUND CORNER AS DESCRIBED
(E
INLET GRATE
O
STORM MANHOLE
SET 44 REBAR LS 14823
0
DECIDUOUS TREE
CONIFEROUS TREE
v.�
l I
WATER VALVE
EASEMENT LINE
G GAS LINE
-E ELECTRIC LINE
FLOWLINE
- EDGE OF ASPHALT
X FENCE LINE
u Prospect Road
c a6 (n
t Balsam L io o c
Juniper Ln Boy Or o In o
10
-- arke
Birky PI
3
Sheely Or U)
E o Alpert
226ura Dr or
Edge
interberry
J risen Dr
c
Sprin a k
Or
�v
Ar
Rd
ad
r
3d et
r
D�O
Dart
Rutgers Av
Qa
S I
0
>
c
0
N'�
0Q0
`o
a
4
c
1in9tOn
a)
Y
0
Wa
�
Pie
0
v
3
Cr
Den, tre
m
r
o
0
0
a
Princ
Prin
etdon
a Ba
Drake Road
n
R3
~
Dr
El i cker
0
Winche
s
ter Da
Ln.
LEGAL
LOT 1, BANKCENTER SQUARE FIRST FILING, LOCATED IN THE NE 1/4 OF SECTION
23, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT
COLLINS, COUNTY OF LARIMEH, STATE OF COLORADO.
\ SPRING COURT SUBDIVISION
-------- --
I , -_ARTHUR DRIVE
S 84° i " E
3313 E
FOUND #4 REBAR I11
(NO CAP) 15' UTILITY EASEMENT III 243.9g9,
FOUND REBAR
(BENT-- NO CAP) �'
OTCONCRETE WALL
RIP I /__�WPIPE /^. v��"��".BARRICADE;' GUARDRAIL
SIGNS\ -FENCE
4" GAS PIPE
TREES
- , \ 0.T CONCRETE WALL
co' I II O GUARDRAIL ENCE - - -- _ --- -
.-1 i I II I i
` N
\ �I ASPHALT
LOT 1
,, ASPHALT
MIII ,ZII PARKING PARKING
z v Y- M � 68,067 sq tL
w I 0 h 1-563 acres a
LOT Wia�l
a it mLLI , w
�oplw 11 + Z
F t01
o M
9 Ir ti'I -
W of wI
°�' (Ii ZowmIil IWU O0'
m0ZI1l
0 to
G
MIzZpQIj..'.�
36.9'
�W
W¢ ATAZ FWto
w a
Z I o_ POSTS
I' Q >
35' INGRESS & EGRESS I O W <
ROAD RIGHT-OF-WAY 1 STORY STUCCO U
W/BASEMENT N " LU O
N O
FOUND#4 REBAR AREA OF SITE CHANGES OJ 2
w1cAP ILLEGIBLE U
Iff I - -- -_- - 1
6 108.1' '1jI
IN89°21'13" p a6 34_3'
FOUND NAIL 35.00'
r N
I
of
ASPHALT
RR J PARKING (n II
- -- - - - r - -107.7's
� �f )° L C
QbICBETE)A 40' EASEMENT FOR WATER PIPE 0 v �l
AND SEPTIC LEACH LINE CD
2.5' PVC 0
AND INCIDENTAL PURPOSES Z oq io ASPHALT 35' INGRESS & EGRESS 1
BOOK 991 PAGE 437 ZII ROAD RIGHT-OF-WAY �Q
/ 6' UTILITY EASEMENT
- - - I Nr9°21'13" W 200.03' - -
FOUND PK NAIL I FOUND PK NAIL FOUND PK NAIL
FOUND PK NAIL O.T CONCRETE WALL
I
0.T WOOD WALL
NONEXrLUSRIGHT-CF-WAY LOT 2
BOOK 1646 PAGE 208
I I
1rSISURVEY / EXISTING CONDITIONS
1- ALL PORTIONS OF THE EXTERIOR WALLS OF THE FIRST STORY OF ALL BUILDINGS WILL BE
LOCATED WITHIN 150' OF AN ACCESS ROADWAY IN WHICH EMERGENCY FIRE EQUIPMENT CAN BE
MANEUVERED OR THE BUILDINGS WILL BE PROVIDED WITH AN APPROVED FIRE EXTINGUISHING
SYSTEM.
2. REFER TO SITE SURVEY /EXISTING CONDITIONS (THIS SHEET) FOR LOCATION OF UTILITIES AND
DRAINAGE.
3. SIDEWALKS AND RAMPS WILL CONFORM TO CITY STANDARDS-
4. CONSTRUCTION IS SCHEDULED TO BEGIN AND COMPLETED SPRING 2010.
5. BUILDING -MOUNTED FIXTURES WILL FEATURE DOWN -DIRECTIONAL AND SHARP CUTOFF
LUMINAIRES-
6. ALL ROOFTOP MOUNTED MECHANICAL EQUIPMENT IS TO BE FULLY SCREENED FROM PUBLIC
VIEW WITH ROOFTOP PARAPET WALLS.
7. ALL SIGNAGE TO COMPLY WITH LOCAL SIGN CODE.
8. BIKE RACKS ARE TO BE PERMANENTLY ANCHORED TO CONCRETE-
9. ALL HANDICAP PARKING SPACES, AND RAMPS ARE TO BE VERIFIED WITH CIVIL ENGINEER FOR
GRADING, DRAINAGE, AND ACCESSIBLE ROUTE CONSIDERATIONS. HANDICAP PARKING SPACES
SHOULD SLOPE NO MORE II IAN 1.48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES SHOULD SLOPE
NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND NO MORE THAN 1-48 CROSS SLOPE.
10. THE CONTRACTOR SHALL BI COME FAMILAR WITH THE EXISTING SITE CONDITIONS PRIOR TO
COMMENCING WORK. CONCERNS, DESCREPANCIES AND UNUSUAL FINDINGS ARE TO BE
COMMUNICATED IN WRITING TO THE OWNER AND ARCHITECT-
11. MINIMIZE DISTURBANCE OUTSIDE LIMIT OF WORK
12- CONTRACTOR SHALL REPAIR ANY DAMAGE INCURRED DURING CONSTRUCTION OUTSIDE LIMIT OF
WORK TO ORIGINAL CONDITION.
13. ALL CONNECTIONS TO EXIST ING WALKS, CURBS, DRIVES, AND OTHER SITE FEATURES SHALL BE
CLEAN AND SMOOTH AND MATCH, ELEVATION OF ADJACENT SURFACES.
14. CONTRACTOR TO COORDINATE FINAL LOCATION OF FURNITURE IN FIELD WITH LANDSCAPE
ARCHITECT PRIOR TO INSTALLATION.
15. ALL PAVEMENT ON SITE TO BE STANDARD GREY CONCRETE UNLESS OTHERWISE SPECIFIED.
I
i
1
I
I
I
NEW CONIC. WALK
■
ABBREVIATI
6" CURB
P.B. �___ _ P.B. TRUNCATED
DOMES
k 6.33'J i---EXISTING WALK
THE UNDERSIGNED
DOES/DO HEREBY
CERTIFY THAT I/WE ARE
THE LAWFUL OWNERS
OF THE REAL PROPERTY
DI SCRIBED
ON THIS SITE FLAN AND
DO HEREBY CERTIFY THAT
I/WE ACCEPT THE
CONDITIONS AND
RESTRICTIONS SET FORTH
ON SAID SITE PLAN.
OWNER (SIGNED) DATE
THE FOREGOING INSTRUMENL WAS ACKNOWLEDGED BEFORE ME
THIS DAY OF A D., 20
(PRINT NAME)
AS
MY COMMISSION EXPIRES: -
WITNESS MY HAND AND OFFICIAL SEA[
Ra7�T:;7�1:3Q�
1 PARKING CALCULATIONS
PARKING RATIO -RETAIL
4 SPACES PER_1000 SF
BUILDING SQ. FT-
7,776
SF
MAXIMUM PARKING REQUIRED
31
SPACES
PARKING PROVIDED
STANDARD SPACES
29
SPACES_
STANDARD ACCESSIBLE SPACES
_
1
SPACE
VAN ACCESSIBLE SPACES
_ _
1
SPACE
TOTAL PARKING SPACES
31
SPACES
SHOW ROOM
.,
B BOULDER
P.B. PLANTING BED
R RAMP
NEW COLOR
CONCRETE PATIO
FOUR KE BOLLARDS
(GUST ER PARKING)
ENTRANCES
/ 09.0� ,
12!- D8.78
�RAMP
08.72� II
L--�
1% SLOPE
NEW J A P. B.
�CONC. r-
SAWCUT m
L _ _ _ 42\8.34 Ct .15 /
8.1
YP.H.C.8' 5
VAN 19SLOP
NEW 6' CURB
3LTf__t I
4 4 4\
mj -
WE
1
Y
J
Q I
3 I
C9
Z
F-
(n
X
W
MONUMENT SIGN
SAWCUT _
0 .10
° 12'
4'X4' TYP.
P.B.
EXISTING
CURB
TWO 6" -- -
RISERS &
ONE 24' +07.81
TREAD
TWO 36" DIA. NEW 6" CURB
CONIC. PLANTERS
TWO 60" BENCHES
P.B.
P.B.
i
P.B. P.B.
ENTRANCE DRIVE
1 SITE IMPROVMEN
� 1' .Ai F-
2101 S.
COLLEGE
RETAIL
FORT COLLINS, COLORADO
■ architecture ■ land planning
■ landscape architecture ■ interior design
401 West Mountain Avenue Suite 200 Fort Collins, CO 80521
fax 9701224.1662 phone 9701224.1191 www.vfrdesignfnc.com
IN ASSOCIATION WITH:
APPLICANT
IMAGO ENTERPRISES, INC.
LES KAPLAN
140 PALMER DRIVE
FORT COLLINS, COLORADO
PHONE: 970.226.6819
FAX: 970207.9256
CONTRACTOR
DOHN CONSTRUCTION
BRIAN BLAKE
2642 MIDPOINT DRIVE
FORT COLLINS, CO 80525
PHONE: 970.490-1855
STRUCTURAL ENGINEER
LARSEN STRUCTURAL DESIGN
BLAKE LARSEN
10820 PRIMA DRIVE
FORT COLLINS, COLORADO 80526
PHONE: 970,568.3355
ISSUED
No. DESCRIPTION DATE
1 IMINORAMENDMENT 2/115/2010
REVISIONS
MINOR AMENDMENT
SEAL:
PROJECT No= 2009-70
DRAWN BY- DJ
REVIEWED BY: JDJ
ARCHITECTURAL SITE PLAN
DRAWING NUMBER:
AS,01
SYSTEM NOTES_
ROOFS
PREFINISHED METAL 5TANDING SEAM ROOFING SYSTEM
R1 -
(BERRID(5E CURVED AND TAPERED TEE PANEL) - COLOR
SELECTED FROM MANUFACTURERS STANDARD RANGE BY
ARCH. OVER
- #30 FELT PAPER OVER
- 1/2" PLYWOOD 5HEATHING SUBSTRATE OVER
- STEEL TUBE FRAMING AND 8" C-STUD PERLIN5
PREFINISHED METAL 5TANDING SEAM ROOFING SYSTEM
R2 -
(BERRIDGE TEE PANEL) - COLOR
SELECTED FROM MANUFACTURER'S STANDARD RANGE BY
ARCH. OVER
- #50 FELT PAPER OVER
- 1/2" PLYWOOD SHEATHING SUBSTRATE OVER
- STEEL TUBE FRAMING AND 6" C-STUD PERLINS
EXISTING BUILT-UP GRAVELED ROOF SYSTEM. TO BE PATCHED
R3 AND REPAIRED AS NEEDED.
MODIFIED BITUMEN ROOFING SYSTEM OVER EXISTING INSULATION.
R4 TIE INTO EXISTING BACK OF ROOF AT EDGES. REPLACE EXISTING
ROOF BD. AS NECESSARY
EXTERIOR WALLS
Wt E.I.F.S. SYSTEM: STO "EIF5 NEXT WITH GOLD
GUARD MOISTURE PROTECTION" OR 5ENERGY
"CHANNELED ADHESIVE DE516N W/ 5ENERFLEX
5ECON12ARY WEATHERBARRIER
-E.I.F.S. FINISH GOAT, BASE GOAT d REINFORCING
MESH OVER
-RIGID INSULATION BD. (THICKNESS VARIES
FROM 3/4" TO 1 1/2") OVER
-ADHESIVE APPLIED W/ NOTCHED TROWEL TO
CREATE VERTICAL DRAINAGE CHANNELS OVER
-FLUID APPLIED MOISTURE
PROTECTION/SECONDARY WEATHER BARRIER
(STO "GOLD GUARD" SYSTEM OR 5ENERGY
"5ENERFLEX") OVER
-1/2" EXT. GYPSUM SHEATHING OVER
-6" COLD ROLLED METAL STUDS o 16" O.G.
U.N.O. SEE 5TRUCT. FOR GUAGE s SPECIAL
SPACING CONDITIONS.
- PREFIN. METAL WALL PANEL SYSTEM INCL. ALL
W2 MFR'5 RECOMMENDED FLASHINGS, TRIM, TERMINATIONS, ETC,
(FIRESTONE UNA-GLAD PANEL 5ERIE5 1200). 2" VERTIGLE AND
HORIZONTAL JOINTS TYP.
COLOR: AS SELECTED BY ARCH. OVER
- TYVEK COMMERCIAL WRAP MOISTURE BARRIER. TAPE ALL
SEAMS AND JOINTS OVER
- 1/2" 05B SHEATHING PER 5TRUCT. OVER
- 6" COLD ROLLED METAL STUDS FRAMING PER STRUCT.
❑- PREFIN. METAL WALL PANEL SYSTEM INGL, ALL
W3 MFRS RECOMMENDED FLA5HIN65, TRIM, TERMINATIONS, ETC,
(FIRESTONE UNA-0LAD PANEL SERIES 1200). 2" VERTICLE AND
HORIZONTAL JOINTS TYP.
COLOR: A5 5ELECTED BY ARCH. OVER
- TYVEK COMMERCIAL ARAP MOISTURE BARRIER. TAPE ALL
SEAMS AND JOINTS
- 6" COLD ROLLED METAL STUDS FRAMING PER 5TRUCT. OVER
- EXISTING ALUM. STOREFRONT.
0
J 1- 3 GOAT, 3/4" PORTLAND CEMENT STUCCO SYSTEM W/
ACRYLIC FIN15H COAT:
QI -STUCCO ELA5TOMERIC FIN15H COAT OVER
Z -2 GOATS OF PORTLAND CEMENT BASE COAT OR MORE TO
LEVEL SURFACE OVER
-2.5 LB. GALV. MTL. LATH OVER
O - EXI5TIN6 PRECAST WALL PANELS WITH GRAVEL EMBEDED
ti
oFINISH
-STUCCO ELA5TOMERIC FINISH GOAT OVER
rya) - EXI5TIN6 E.F.I.5. WALL FINISH
SOFFITS
E51 - PREFIN. MTL. SOFFIT PANELS
(BERRIDGE FLUSH SEAM PANEL) OVER
- 1/2" OSB SHEATHING OVER
- STEEL FRAMING
m CEILINGS
>
0 Gt - EXPOSED ROOF DECK 4 STRUCTURE.
Cr
G2 - 5/8" GYPSUM BOARD (PAINTED)
p - METAL FRAMING OR METAL SUSPENSION 5Y5TEM
M
N
C'
ai INTERIOR PARTITIONS
U SEE 5HT. A10.0 FOR PARTITION TYPES d DETAILS.
.r- ALL INTERIOR PARTITIONS ARE TYPE P-1H UNLESS OTHERWISE NOTED
0«"
O
r�
to
11')
6
N
M
O
0
N
to
04
PANT EX
EXTEROF
FINISH WI'
ELASTON
r- FIN. FLOOR
100' - 0"
RELOCATE
EXTERIOR GAS
PIPE TO INTERIOR
NEW PREFINISHED METAL CANOPY
i
PAINT EXISTING
4i
EXTEROR STUCCO
FINISH WITH l
ELA5TOMERIC PAINT.
I � 1
I�
V9
' I
FIN. FLOOR
100, - 0" E rxca .. -
SOUTH ELEVATION
SCALE: 1/8" = 1'-0"
�
LEVEL 3
12,'-0"
f LEVEL 2
116 - O
FIN. FLOOR
114- 100' - 0"-
NORTH ELEVATION
SCALE: 1/6" = 1'-0"
WEST ELEVATION
SCALE: 1/8" = l'-O"
BEYOND
J
SAND , CAULK JOINTS
AND PAINT ALL
PRECAST PANEL TRIM
TYP.
NEW ENTRY
STOREFRONT
CJ
EXI5TING
6AS METER
SAND, CAULK JOINTS AND PAINT ALL
PRECAST PANEL TRIM
TYP.
M�M
NEW STOREFRONT TO
REPLACE EXISTING.
LEVEL 3 LEVEL_5
iol
124' - O" All,124' - O" -
LEVEL 2
F-IN. FLOOR_ r FIN. FLOOR
100' - O" 100' - O"
516NAGE SHOWN FOR
REFERENCE ONLY.
ACTUAL SIGNAGE
DESIGN BY OTHERS
NEW PREFIN15HED METAL CANOPY
- - LEVEL 3 y
- - -�
L 124' - O"
°mil- R1 Wt
. _-.'��
-_ 1d - - LEVEL 2
F-
I I
i !r - -- --- ICI
LIGHT FIXTURE -
SEE ELECT. TYP.
_-
---- -� I -- -- FIN. FLOOR �
i
100' - 0"
NEW STOREFRONT
NEE N WINDOW
516NAGE SHOWN FOR
REFERENCE ONLY.
ACTUAL 51GNAGE
DE516N BY OTHERS
W1
-�- IIIII j-I ���11
"11
L- —III Jf
} 'ry' I!
NEW OPENING WITH NEW
STOREFRONT.
EAST ELE\/ATION
NEW ENTRY
STOREFRONT
FIN. FLOOR go
100' - 01,
5GALE: VEY = 1'-0"
2101 S.
COLLEGE
RETAIL
FORT COLLINS, CO
architecture land planning
landscape architecture interior design
401 West Mountain Avenue Suite 200 Fort Collins, CO 805:11
fax 970/224 1662 phone 970224 1191 wvnv.vfrdesigninc ccm
In association with:
Owner:
Imago Enterprises Inc.
140 Palmer Drive
Fort Collins- Co 80525
ph. 970 / 2266819
f 970 / 207.9256
CONTACT: Les Kaplan
Contractor:
Dohn Construction Inc.
IXr�
,.I
2642 Midpoint Dave
Unit A
Fort Collins. CO. 80525
ph 970 / 490.1855
f 970 / 490.6093
CONTACT, Brian Blake
Structural E
LMSEN
Larsen Structural Design
ural D
STRUCTURAL DESIGN
10820 PRIMA DRIVE
FORT COLLINS, CO. 8052
ph. (970) 508-3355
f. vxx / xxx xxxx
CONTACTBlake Larsen
Issued
No. Description Date_
1 MINOR AMENDMENT 2.15.2010
Revisions
No. Description Date
SAND, CAULK JOINTS
AND PAINT ALL
PRECAST PANEL TRIM MINOR AMENDMENT
TYP.
Seal
—� W4 Y44
STUCCO FINISH
OVER EXI5TIN
PRECAST PAN
�
— LEVEL 2�
IIII�
u
j III II Project No.: 2009-70 Drawn by: LH
i
Reviewed by: GO
I Iya
p 9' FIN_. FLOOR_
100' - O"
ELEVATIONS
Scale Accordingly if Reduced
Drawing Number
AO. 1