DATE: October 30, 2003 TO: Technical Services
PROJECT: #k35-03 HECKART SUBDIVISION —TYPE I (LUC)
REC,.p
All comments must be received by Steve Olt no later than the staff
review meeting:
November 26, 2003
Note -PJ EASE identify your redlines for future reference
111L ;-III,- " s I p i " -
Wr-A7- 14 /ja,T %H(s- ///E/eG,'2 t)iTcN '147
-`i-jC N- f= , S I n C GoL- L,, 1
Tb
A CITILIT,7
C IL, Lit-
1 Tc;
::��nv,c
—
` 0 T
Z ?
Tim l exi ���s /L1V7 �lCcT /ry SC.�}
J
Name (please print)
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
l Plat _Site _Drainage Report Other
_Utility _Redline Utility _Landscape
Number: 28 Created: 11/26/2003
[11/26/031 Provide a flowline profile for the design and
construction of this development's frontage along LaPorte Avenue.
Number: 29 Created: 11/26/2003
[11/26/031 Remove and replace the area inlet shown in LaPorte
Avenue with a Type 3 inlet. Provide the appropriate details and
approximate street cut. Provide the street cut note:
Limits of street cut are approximate. Final limits are to be
determined in the field by the City Engineering Inspector. All
repairs to be in accordance with City street repair standards.
Number: 30 Created: 11/26/2003
[11/26/031 Show where the existing yard hydrant is being relocated
to.
Number: 31 Created: 11/26/2003
[11/26/031 Correct the easement labels to read:
20' Emergency Access Easement
24' Emergency Access and Utility Easement
10' Drainage and Utility Easement
Number: 32 Created: 11/26/2003
(11/26/031 what's happening with the sewer clean -out shown on Sheet
3? Does it tie into something? Is it being removed? Abandoned?
Number: 34 Created: 11/26/2003
[11/26/031 Detail Sheet - Remove detail 706 and replace with 707.
Change the design in accordance with 707.
Number: 35 Created: 11/26/2003
[11/26/031 Place the Construction Notes on Sheet 6 behind the
General Notes - in other words, Sheet 6 should be Sheet 2.
Number: 37 Created: 11/26/2003
[11/26/031 Provide erosion control for Lot 2 and show on the
Drainage & Erosion Control Sheets.
Number: 40 Created: 11/26/2003
[11/26/031 Contact PFA as soon as possible. Lot 2 may be out of
service and must be sprinklered. Lot 2 may not meet the 150'
accessibility requirement.
Department: Natural Resources
Topic: General
Number: 44
(11/28/031 No Issues.
Page 4
Issue Contact: Doug Moore
Created: 11/28/2003
Department: Police
Topic: General
Number: 6
[11/24/031 How will lot be addressed
emergency vehicles.
Issue Contact: Joseph Gerdom
Created: 11/24/2003
concern about directing
Department: Stormwater Utility Issue Contact: Wes Lamarque
Topic: Drainage
Number: 41 Created: 11/26/2003
The inlet and storm sewer need to be improved with this PDP. A 5-
foot Type-R inlet with a 15-inch diameter outlet pipe is required to
replace the existing inlet and pipe. Please call Wes Lamarque at
416-2418 if you have nay questions.
Number: 43 Created: 11/26/2003
Please revise the benchmark on the cover sheet. See redlined plan.
Topic: Erosion/Sediment Control
Number: 42 Created: 11/26/2003
There should be some text in the report and some proposed erosion
control measures shown on the plans for this site even though the
site is small. There are some imprcvements to be made on both lots.
Please call Bob Zakely at 221-6700 for information regarding what is
to be required.
Department: Transfort
Topic: General
Number: 7
[11/24/03] No comments
Department: Transportation Planning
Topic: Transportation
Number: 38
[11/26/031 No comments
Issue Contact: Garold Smith
Created: 11/24/2003
Issue Contact: Tom Reiff
Created: 11/26/2003
Department: Water Wastewater Issue Contact: Jeff Hill
Topic: General
Number: 2 Created: 11/24/2003
[11/24/031 Meter pit and curb stop may not be located with in public
right of way. Place curb stop 1 foot from rear of utility easement
and meter pit no more than 2 feet beyond that. Provide utility
easement for meter pit for Lot 2 on Lot 1. Label proposed 24 foot
wide access easement as access and utility. Maintain 10 feet of
separation on both sides of water and sewer lines to utility
easement.
Number: 3 Created: 11/24/2003
[11/24/031 Has 27-inch water main been pot holed? Pothole the
existing water main now, to determine if this area is in a lowered
section for the ditch crossing. The eater service may not be located
in lowered section of water main.
Paec 5
Number: 4 Created: 11/24/2003
[11/24/031 Provide existing sewer inverts in the existing manhole.
Our records indicated that an existing 8-inch stub and a sewer
service already, exist in the existing sanitary sewer manhole (see
print out attached to utility plans). Remove the existing 8-inch
stub and install new service in this existing location. Include note
to grout opening closed with non -shrink grout.
Number: 5 - Created: 11/24/2003
[11/24/031 See site, landscape and utility plans for other
comments.
Department: Zoning Issue Contact: Jenny Nuckols
Topic: Zoning
Number: 1 Created: 11/4/2003
[11/4/03] On Lot 2, there is no need to show the location of the
proposed house on the site and landscape plans. It may change when
it comes time to actually build. Its location will be reviewed when
the permit is applied for to be sure that it complies with setbacks,
etc.
The following comments were expressed at staff review on November
26`":
Engineering:
1. The design and construction for necessary improvements to
LaPorte Avenue associated with this development request must be
done at this time.
2. See Appendix 6 for scanability requirements.
3. Easements to Lot 2 are needed.
4. The curb returns must have a radius.
5. A building envelope, rather than a building, should be shown on
the Site Plan.
6. Tie the proposed sidewalk along LaPorte Avenue into the existing
walk.
7. An easement for the New Mercer Ditch, and a signature block for
the Ditch Company, must be added to the subdivision plat.
8. Erosion control for Lot 2 must be provided.
9. There is a little off -site aradina needed for this development
that requires an easement from than property owner.
Paee 6
Water/Wastewater:
1. There is water and sanitary sewer in the LaPorte Avenue right-
of-way.
2. There is an existing 8" sanitary sewer service stub into the
property.
3. Where is the fire hydrant for Poudre Fire Authority service?
Stormwater:
1. Type 'R' - 151, pipe must be used.
Light & Power:
1. Electric service is from LaPorte Avenue.
2. Please contact Rob Irish, at 224-6167, if you have electric
service -related questions.
This development proposal is in a condition to be able to be
scheduled for an administrative public hearing. Please contact me to
schedule a date and time for the hearine, which must be held in the
evening because the property for proposed development is in a
residential neighborhood. We must have the required notification
letter out to all Affected Property Owners at least 14 days prior to
the date of the public hearing.
The comments contained in this letter may be addressed with a re -
submittal prior to public hearing or with a final plan check after
the hearing. Please be sure and return all of your red -lined plans
when you re -submit documents.
If you have any questions regarding these issues or any other issues
related to this; project, please feel free to call me at 221-6341.
Yours �pTruly,
ul�
/,ur
Steve Olt
City Planner
cc: Susan Joy, City Engineering
Frank Heckart
Current Planning File #35-03
Page 7
6 STAFF PROJECT REVIEW
�t<,•„a�- 1 Ass_r__ates Lute: 12/3/_003
Ja,:,k 15ia'L:e
103 South Meldrum Street
-rt Collins, C^. 80521
has ;'iewe ! surmittal fog- H3CKA T Sli BL?I`IISION - TYPE
s
a^ We c "er --e f::ilo��ng comments:
ISSUES:
Department: Current Planning Issue Contact: Steve Olt
Topic: Landscape
Number: 50 Created: 12/3/2003
[1^i3/(!'; Please see red -=fined Landsraoe Plan _'or Current P1anr,_..
mments.
S&A Response: Revised per red -lined plan.
Number: SI Created: 12/3/2003
11 _ proposed Autumn Purple Ash trees to be used as
ret_ tr -s a'_ena-aP,--te Avenue are not on the City's Aopreved
Etree� Tree L:_st. P-_ease make another selection from t�:e list.
S&A Response: Revised
Topic: Plat
Ni::n"er: 4r Create:;: 1-/3/2C:-,
i12/3/C31 Len Hilderbrand of Xcel Energy offered the following
csmin er:ts
a. The nropcsed 5' utility easements are not adequate. If the
owner yequests natural g_s then the 5' easements would need to
.S&AResponse: See "(".
.-. DIo fences, trees, or bushes can obstruct the installation of
- ..'_nes.
.S'&A Response: Gas line to he in access drive.
Is it possible to make the access drive a utility easement?
S&A Response: Access drive made a utility easement forgas service also.
Number: 47 Crewed: 12/3/2003
�12/3/C3] Rot Irish of City Light S Power offered the following
;purer--s :
a. Power fc_ this property wi11 come from LaPorte Avenue.
S&A Response: Acknou leda ed.
Page I
1-1
caner w_11 -d to dinate the a'_.-ctri_ meter
w i Light F Pow__.
S&A Response: Acknoivlerl,ed
�. .✓_; T i ti. s or rela-sting el . t-=
...-.�-r,._.__:.._ wil.i Co a- ..'::e -, owner'_ e.: r%ense.
S&A Response: Acknowledged
d. The property owne- will be -e sonsible for residentia-
cieveloprr;ent charges.
,V&A Response: Acknowledged
Number: 4p Created: 12/3/2003
^i3/C?] There appears to be an error in the east procert_i lines
of I-t 1 and the road ryar_t-�`_ .w Tee two distan(es of 319.9s' +
4- )'.' v_ ct add u_e c_.00 The wculd ecua1 36'_.98'.
S&A Response: Reviser!.
Topic: Site
Plumber: 49 Created: 12/3/2003
[12/3/03] Please see red -lined Site Plan for Current Planning
corr4nents .
.V&A Response: Revised per Red -lines.
Department: Engineering Issue Contact: Susan Joy
Topic: General
TV1lnber: _-- Crewed: 11/26/23C3
;1!/_-:/C'3; This devel--pme.n.t _s responsible for the design and
;:'m;txu of L- 'orte a1-ng their frontage. Pleas_ revise
a_1 olan =-t_s t.o _r.ci�,.de this req-._iroment.
S&A Response: Per our meeting the owner can escrow for LaPorte Avenue. Language to be in the
development agreement.
C;.:rriber: 1? Created: 11/26/2003
See Apoendi ter, for Ica.^.abi'_i'y xeci,..irernents. Tr,.e
current plan. sets do not meet t._� City's .scanning standards.
S&A Response: OK
Nur�oer: 14 Created: 11/26/2003
Please re^ise all plaa sets to pro -,-_de drivewa_Y access
t-> J��iP-rte Avenue in accordance with detail 707.
S&A Response: Please reviov this again. We are not a high use driveway.
Number: 15 Created: 11/26/2003
Provide ut_-=tv ea=cements to Lot _.
S&A Response: Dome
Number: 16 Created: 11/26/2003
[11/26/03] Do not show the actual building but provide a building
envei;:i�e instead.
S&A Response: Have taken building off Sheet 3.
Page 2
^i�:ctrac i? Created: 11/26/2003
/ ��_• _: c pr s-'J __S.c:va_^ Snc,,^n a—On3 LaFC- e
Inca._-
S&A Response: Revised as shown.
Dicmber: _, .._eated: 11%26/2CC3
;11/20/03 the L_t h C,^r:oanv's easement on all plan sets a -I
pr ,_ae Nod Mercer S'gua_u_2 beck_ on the serious plan sets.
S&A Response: Revised.
i4cmbe-: 23 Created: 111'2F12903
C:2rdir.ata _ e =-..ents am —a -he oar�ous plan sets e_
i -he_ all E.r ide - same. infa.rm, Ic n.
S& A Response: Reviser.
Dlurr�er: 36 Created: 11/26/2003
[1'/2r/:73] IS the pl.a_emenc ,f t_ice Emerg-ncv Access dr5.ve
,:,:eptable tc PFA? The currer:- confrgtlraticn etas the fire truck
st aqiscr anrnr a.ima-e,1 5 3 ' away f-om. the building. -hat leaves only
=0:" tee oac} the tr._, _t part the building in order r-
In_ b•iiId_ as event -cal r. _a�emen _ gcing mee-
need to be ar+- i,te5
L i'A f
S&A Response: Driveway OK as revised Actually Lill' distance ! believe is the norm
Topic: Landscape
Nurn'cer: 39 Crea-ed: _ /26/20u3
i 1/26%':;3; .�..ow all utilities _., the --andscane Dian.
S&A Response: OK, will no.
Topic: Plat
Number: c .-reated: 11/26/20,G3
/'b/53; rom'''--.----_. al Ser.�,�s: D-undary and renal :-lcse.
S&A Response: Good
Nambe.r: 9 Created: 11/26/2003
�11/26/031 From Technical Services: What about the New Mercer
Ditch at tn^ NE earner c_` Lot 1? You need to show the Ditch
e-_em.ent and r -,T:de a siana`ure beck `or them to Sian
S&A Response: Added easement and signature block.
Number: 1G Created: 11/26/2003
From Ie _ni1 Ser -_ces: There needs to be a utili-,
ec-me:_-nc. rasz I .._ 1 servi_r -ct _.
S&A Response: Done
Number: 11 Created: 11/26/2003
[11/26/03] From Technical Services: The text does not meet City
scanning standards.
Page 3
S&A Response: Reviser.
r" 6/C31 radial ,_urb _ _.�_r� re^..grad atr entran:;es.
S&A Response: Please review this comment main. 6i'e are Tjpe L or H.
Dumber: 'S 11/26/200..
1i 3; ePlerga: c P 5 s Bas Cme.^:t re C'ul r e s =5 _nsi Je
ru—ning radii.
S&A Response: Revised.
NImber.-: _
r _ro-�'Jeeas�menrs
.S'&A Response: Dome.
Dumber: 45 Created: 12/2/2003
[12/:-:/03] Pro:ide the Notice z_` Dccurr,ents, see attached.
S&A Response: Dore.
Topic: Site
"r]um'rer: 19 Crea'.ed: 11/26/2CC:3
:11 _6/'i3; Remc _on-.,urs ar.. uriLties.
S&A Response: OKRevised.
N.Amber: 20 Created: 11/26/2003
[11/"h/03] Spell out all' UE and DE labers to read "Utility
F,asernant" and "Drainage Easement".
S&A Response: Added note instead.
Plurnl:>er: Creare:-1:
_11i'J/C3 =_amp _ �Y!e "E_�rsti^g _C' Gracel Dr;veway" Labe- and
_ei.iace with a 24' Em:rlency :cess >and Utility casement" label.
S&A Response: Revised
Topic: Utility
Dumher: 27 Created: 11/26/2CC3
[11/26/C3 Shee`_ 3 - Provide a curve table and dimensions for t_ne
>il-,calk a'_;ng LaPorte venue s., that they can lay this out in the
-field.
S&A Response: Done and added.
^Pami;er: _E, Created: I1/26/ 20n3
[11/26/03] Provide a flow -fine profile fer the design and
:,_)nstruction of this develonment's fror.-age along LaPorte Avenue.
S&A Response: Added to Sheet No. d.
Dumber: 29 Created: 11/26/2CC3
11L/26/03; Remove and replace the area inlet shown in LaPorte
Avenue with a Type 3 inlet. Provide the appropriate details and
apE-:ro:;i:nate street cat. Provide the s`_reet cut rote:
S&A Response: Revised to 7_ppe R. Added to details.
Page 4
.r-`_s of cut �nnr- mat.. Fi na _imi:_ . ara rc be
9� --mine __ _�_, r, C E:.., .^ee-in"
. -,a-r.; a �.:r:7 r—, W' Lena i _ and_. is.
S&A Response: Revised
Number: 30 Crewed: 11126120C3
1/ 25/'7? Stt ;w where he _c; . 3 -! 1:_;-Irant is 'being _oval=
.S&A Response: (hvner will relocate where he decides.
Number: 31 Created: 1'/26/2003
031 rxe,,t th- ease:ne*:` -abels nn read:
-SEnroraen:,v A.�*cess Eases,en`
_ : Emerger.cr,� Access and Gti11t-y Easement
10' Drainage and L'ti__ty Easement
S&A Response: Reused .See notes.
�i 1 imbe_ . 3_
[11/;,_b/031 What's ::^.apnenInq with
D,3 it tie something?
S&A Response: Revised to V1H now.
Created: 1/26/2CO3
the sewer ..lean -out show.. on Snee`
Is __ being removed.' Aba nd.ned:
Ni.zmber: 34 Created: 11/26/2003
11/26/031 Det�.y� Sheet - Remoae detail 7C6 and replace with 70?.
change the Jerrign in ,scordance with 707.
S&A Response: Please review again.
Dlumber: 35 Created: 1/26/20G3
li
__/ G.' =1-. _ _ t:'1e C atr'1_ __r N tes _>n She,` o c'h1r.:7
Derr, --ai N _ - in -rhe. _rds, Sheet 6 shcr.yd be Sheet_ _.
S&A Response: Done.
Number: 37 Created: 11/26/20C3
r11/'6/03' P—vide eros`_or: control for =ot _ and show en the
Er;,s_ rI ,-sntrol Sheets.
.S&A Response: Revised.
Number: 4n Created: 11/26/2003
,11_/2 /031 Ccn-a. t PFA as _n as rxossible. Le-� 2 may be out �f
x_c ar.l Lot may meet the - ,.1
.S&A Response: Will meet PFA required fire hydrant or etc.
Department: Natural Resources Issue Contact: Doug Moore
Topic: General
t1,1mber: Created: 11/2P/ %003
1!33/C3] Nc lss'ces.
S&A Response: Acknowledged
Page 5
Department: Police
Topic: General
Number:
/34/L'31 a wl-_ icz 'oe
�meraencv ,ehi�__es.
S&A Response: Numbered by the City
Issue Contact: Joseph Gerdom
Cleated:-1/'-4/-'/'—;3
ad,._esseci - coccern about directing
Department: Stormwater Utility Issue Contact: Wes Lamarque
Topic: Drainage
Dumber: __ Created: 11/26/20C-,
:d . a sew,_ need be ,mnroued wi-n this PDP.
� -7 ' nle* w t,- a 'iiam cer .,u`lat plc �s r :ir--i t'-
in.t a-- pipe. P case ca_'_ Vves Larrar_iie ac
_- voa .:a_ques-.i rs.
S&A Response: Revised.
iJumber: 4? �_eated: 11/25/2003
-r, the c,e- sheet. See red_ined c=a^
S&A Response: Done. Thanks.
Topic: Erosion/Sediment Control
N(imber_: 42 Created: 11/26/2003
the a'rr.Ld be t_o= in the report and some proposed erosion
Lr. = cr .:.crew `.-"a^. -n the 1- _ns �h-s site even trough t} e
sma11. T/ , � m, _;rr,=,emen-s to be madam cn
for ...__rTa`--.P, ,.33rdin, _E
tc t_-euuired.
S&A Response: Added silt fence asshown on Sheet 4
Department: Transfort
Topic: General
Miiinber: 7
[11/24/03] No ccminents
.S&: t Response: Acknowledged
Department: Transportation Planning
Topic: Transportation
Ne r : 3 �,
11L/26/03[ No com_*aents
S&A Response: Acknowled,ed
Department: Water Wastewater
Topic: General
Nuriber : ..
Issue Contact: Garold Smith
Created: 11/24/2003
Issue Contact: Tom Reiff
*ed: 11/26/2003
Issue Contact: Jeff Hill
Created: 11/24/2003
[11/24/03; Mates pit_ and curb stop may not be located with in public
right of way. Place curb stop 1 foot from rear of utility easement
cal m,�ter pit no more tnan 2 fce-_ bev=d that. Prov-de utility
c,,cct,nt t meter oi- for Lot _ cn L,ot t. Label proposed 24 foot.
N .,cce easement as arc�ss and utility. Maintain 10 f.et of
sep,iration on both sides of water and sewer lines to utility
easement.
Page 6
Project Comments Sheet
"I Selected Departments
City of Fort Collins
Department: Stormwater Utility
Date: November 26, 2003
Project: HECKART SUBDIVISION - TYPE I (LUC)
All comments must be received by Steve Olt in Current Planning, no later than the
staff review meeting:
November 26, 2003
Note - Please identify your redlines for future reference
Issue Contact: Wes Lamarque
Topic: Drainage
Number: 41 Created: 11 /26/2003
The inlet and storm sewer need to be improved with this PDP. A 5-foot Type-R inlet
with a 15-inch diameter outlet pipe is required to replace the existing inlet and pipe.
Please call Wes Lamarque at 416-2418 if you have nay questions.
Number: 43 Created: 11 /26/2003
Please revise the benchmark on the cover sheet. See redlined plan.
Topic: Erosion/Sediment Control
Number: 42 Created: 11 /26/2003
There should be some text in the report and some proposed erosion control measures
shown on the plans for this site even though the site is small. There are some
improvements to be made on both lots. Please call Bob Zakely at 221-6700 for
information regarding what is to be required.
Signature
it lb-O 3
Date
CHECK ]HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
✓ Plat _ Site / Drainage Report Other_
- y,' Utility _yam Redline Utility Landscape
Page 1
Cc-. Sieve DL-
S-5011 Sc
�cwa�'�Qs
S&A Response: Revised water line service and meter pit Locations.
r,ii.Y/'i _sl Ha 1 mate_ .a-r: baen pOt nJ_ed: P. _��_e `ne
-_^g •Nestor ^�.__ n_w, det._mine ifthis area is in a we-ed
tt.e d. t Sing. water e�-"c� m-net or �. _=✓.
wa-_.r ma
S&A Response: A"o. ;tiloved tie into 27" main.
,d..a,ber: 4 C�ea..ad: ii/24/20C3
�11/'4./n3; Pr:-a'_de ._::istir.a sewer inserts in the e:+isting ma.^.nole.
*_hat an -sting 6 inch stub and a sower
a a r__ i .. e ring .an -tar_✓ sewor msnhr _ _—
._ nd -_a1L .'w location.
._ .�rcut nening _ sed l_n n shrirY: grout.
S&A Response: Ada'ed to plans.
C?•_(moer: Crea-ed: �l/24/20n3
[ll/24/03; See site, landscape ana ..tility plans fcr other
comments .
S&A Response: Revised per redlines.
Department: Zoning Issue Contact: Jenny Nuckols
Topic: Zoning
Number: -reated: 11/4/2003
rlL/4/03] ,.n Lot there is nc need t" show the location cf the
pr-,,nosed house :,n the site and landscape clans. T_ -ray change w e-.
imes times to actuail✓ buil:i. Lts wii1 be reviewed when
-h- saenlied for to be sure that itwith setba �b_s,
S&A Response: revised
The following comments were e:_pressed at staff review on November
Engineering:
1. The design and construction for necessary improvements to
La^orte Avenue associated with this development request must be
dene at this time.
_. See Appendia 6 for scanabiiity requirements.
3. Easements to Lot 2 are needed.
4. The curb returns must have a radius.
Page 7
5. .. ruilding _oGe, _t,_..er than a buildine, should be chow^. on
_11te Plan.
E. Tle the :_r _osed sijewa,P.ven.ue rnt< etrsting
walk.
7. n easementt �
_ New Mercer D_tch, and a signature block for
't. Di .. „crrE ,T .�_ re i i. c� tine subd_v'_s_on plat.
_. Erg_.:.. �tr.trc-foi Let _ must be provided.
There a l__tie f ,__e *ad-^? der' fer th's deve�pmer:_
-h,,` r (r .___-. a:: eas • e- fr.:m. tha_ property .-wner.
Water/Wastewater
There is water and sanitary sewer in the LaPorte Avenue right -
of -'day.
There is an e_cisting S." sanitary sewer service stub into the
PL,Dpert„
3. Where is tie fire hydrant for Poudre Fire Authority service?
Stormwater:
1.. pipe must be 'us
Light & Power:
E'.-_-ctric _�__.i ce is from LaPorte Avenue.
Please contact Rob Lrisr:, at 224-6167, __ you have elecr.ric.
service -related questions.
#i�X!+x-t<k<hkx�cxt kth.F<*xt%+#-kti-*<*X*'xx kzx%+max<**+rkxxx-2-kh ri tkzxz<—zt
This development proposal is in a condition to be able to be
scheduled for an administrative public hearing. Please ccntact me to
schedul=_ a elate and time f:-r th:e hearing, which, must be held in the
b cpus- -re property frr prcposed development is in
��,,uJentia] neijhbjrhooa. must have the required notificaticn
's t_r Want j r l I 2ror ert_i Owners a east la days prior
tk_r gate _ t:�2 .io-ic n-ng.
Th.- comments conta_ned in this ierter may be addressed with a re-
.,uomit_tal prior tc public hearing or with a final elan check after
'-h<_ hearing. Please be sure and return all of your red -lined plans
when you re -submit documents.
it you have any questions regarding these issues or any other issues
related to this project, please feel free to call me at 221-5341.
Page 8
Yours
Steve Flit
City Planner
-.7, Citp Engineer_ng
crank Heck:a----
Current Planning File #35—Q3
Page 9
REVISION
COMMENT SHEET
DATE: March 31, 2004 TO: Technical Services
PROJECT: #35-03 Heckart Subdivision PDP — Type I (LUC)
All comments must be received by Steve Olt no later than the staff
review meeting:
April 14, 2004
No Comment
❑ Problems or Concerns (see below or attached)
**PLEASE IDENTIFY YOUR REDLINES FOR FUTURE
REFERENCE** REC.� '84APR
CGO�-
Name (please print)
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat _Site _Drainage Report _Other
Utility _Redline Utility _Landscape
Date
Project Comments Sheet
Selected Departments
Department: Stormwater Utility
Date: April 12, 2004
Project: HIECKART SUBDIVISION - TYPE I (LUC)
All comments must be received by Steve Olt in Current Planning, no later than the
staff review meeting:
April 14, 2004
Note - Please identify your redlines for future reference
Issue Contact: Wes Lamarque
Topic: Drainage
Number: 41 Created: 11 /26/2003
[4/12/041 Please revise notes on utilty and drainage plans. See redlined plan.
The inlet and storm sewer need to be improved with this PDP. A 5-foot Type-R inlet
with a 15-inch diameter outlet pipe is required to replace the existing inlet and pipe.
Please call Wes Lamarque at 416-2418 if you have nay questions.
Topic: Erosion/Sediment Control
Number: 55 Created: 4/12/2004
Please add in text that the minimum $1,000 erosion control escrow will be provided.
Date
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat Site /Drainage Report Other_
✓ Utility _ / Redline Utility Landscape
Page 1
Cl_ She e oL-
Project Comments Sheet
Selected Departments
City of Fort Collins
M
Department: Engineering
Date: April 15, 2004
Project: HE,CKART SUBDIVISION - TYPE I (LUC)
All comments must be received by Steve Olt in Current Planning, no later than the
staff review meeting:
April 14, 2004
Note - Please identify your redlines for future reference
Issue Contact: Susan Joy
Topic: General
Number: 13 Created: 11/26/2003
[4/12/041 Repeat comment.
[11126/031 See Appendix E6 for scanability requirements. The current plan sets do not meet the City's scanning
standards.
Number: 14 Created: 11/26/2003
[4/12/041 In answer to your question of "Why 707 and not 706?", please see table 7-3 and 8-2 in LCUASS. All arterial
streets require radial curb returns with 20' radii on all driveway entrances. Concrete to back of right of way. Please call
if you have questions in the: future, it will save you a round of review.
[11/261031 Please revise all plan sets to provide driveway access to Laporte in accordance with detail 707.
Number: 16 Created: 11/26/2003
[4/12/041 Repeat comment. Show building envelope, all sheets, all plan sets.
(11/26/031 Do not show the actual building but provide a building envelope instead.
Number: 21 Created: 11/26/2003
[4/12/04) The emergency access easement is only shown for the for the western entrance and needs to be carried all
the way around through the eastern entrance as well.
[11/26/031 Remove the "EKisting 20' Gravel Driveway" label and replace with a "24' Emergency Access and Utility
Easement" label.
Number: 23 Created: 11/26/2003
[4/12/04) This comment applies to this round of review as well.
[11/26/03] Coordinate the comments among the various plan sets so that they all provide the same information.
ature
/ Datd
1 CHECK -KEG E IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat _ / Site Drainage Report / Other
Utility _� Redline Utility --/ _ Landscape
Page 1
Number: 24 Created: 11/26/2003
(4/12/04] Repeat comment.
[11/261031 Radial curb returns required at drive entrances.
Number: 25 Created: 11/26/2003
[4/12/041 The emergency access easement has changed since the first submittal. Please provide 25' inside and 50'
outside turning radii.
[11/26/031 The emergency access easement requires 25' inside turning radii.
Topic: Plat
Number: 8
[4/121041
Created: 11/26/2003
[11/26103] From Technical Services: Boundary and legal close.
Topic: Utility
Number: 18 Created: 11/26/2003
14/12/041 Repeat comment. Ditch signature block was only added to plat.
[11/26/031 Show the Ditch Company's easement on all plan sets and provide a New Mercer Signature block on the
various plan sets.
Number: 28 Created: 11/26/2003
[4/121041 LCUASS requires a 1000' of preliminary design on either side of the project boundaries, however, you can
give me just enough spot elevations along the flowline profile for me to verify the design. 25' on either side should do it.
[11/26/031 Provide a flowline profile for the design and construction of this development's frontage along Laporte.
Number: 30 Created: 11/26/2003
[4/121041 Repeat comment.
[11/26/03] Show where the existing yard hydrant is being relocated to.
Number: 31 Created: 11/26/2003
[4112/041 Repeat comment. Easements are still not shown correctly and they are not shown consistently between the
various plan sets.
[11/26/031 Correct the easement labels to read:
20' Emergency Access Easement
24' Emergency Access and Utility Easement
10' Drainage and Utility Easement
Number: 34
[4/12/041 Repeat comment.
Created: 11/26/2003
111/26/031 Detail Sheet - Remove detail 706 and replace with 707. Change the design in accordance with 707.
Number: 37
[4/12/041 Repeat comment.
Created: 11/26/2003
[11126/031 Provide erosion control for Lot 2 and show on the Drainage & Erosion Control Sheets.
Number: 40 Created: 11/26/2003
[4/12/04] Repeat comment. Please show the building envelope on the plans and coordinate with PFA.
Page 2
[11126/031 Contact PFA as soon as possible. Lot 2 may be out of service and must be sprinklered. Lot 2 may not meet
the 150' accessibility requirement.
Number: 56 Created: 4/12/2004
[4/12/041 Cover Sheet - Correction required to General Notes #41.
Number: 57 Created: 4/12/2004
14/12/041 Sheet 4 and 5 - Is the ditch company requiring rip rap for the end of 8" drain pipe or anything else or are they
ok with what's shown? I strongly suggest that you coordinate with the Ditch Co ASAP so that this doesn't become a
problem for you later on. The Ditch Cc will be required to sign the mylars before I can route them for City signatures.
Number: 58 Created: 4/12/2004
[4/12/041 Sheet 4 and 5 - spelling errors.
Number: 59 Created: 4/12/2004
14/12/041 Dimension the utility easement shown on the west side of the east driveway entrance.
Number: 60 Created: 4/15/2004
[4/15/041 Complete Appendix E4 and submit with the next rounds of review. Any applicable items from E4 not shown
in the plans will become a new comment.
Page 3
Project Comments Sheet
L� Selected Departments
itv' of Port Collins
Department: Engineering
Date: April 15, 2004
Project: HECKART SUBDIVISION - TYPE I (LUC)
All comments must be received by Steve Olt in Current Planning, no later than the
staff review meeting:
April 14, 2004
Note - Please identify your redlines for future reference
Issue Contact: Susan Joy
Topic: General
Number: 13
[4/12/041 Repeat comment.
Created: 11 /26/2003
[11/26/031 See Appendix E6 for scanability requirements. The current plan sets do not meet the City's scanning
standards.
Number: 14 Created: 11 /26/2003
[4/12/041 In answer to your question of "Why 707 and not 706o", please see table 7-3 and 8-2 in LCUASS. All arterial
streets require radial curb returns with 20' radii on all driveway entrances. Concrete to back of right of way. Please call
If you have questions in the future, it will save you a round of review.
[11/2(,,/03] Please revise all plan sets to provide driveway access to Laporte in accordance with detail 707
Number: 16 Created: 11 /26/2003
14/12/04] Repeat comment. Show building envelope, all sheets, all plan sets.
[11/26/03] Do not show the actual building but provide a building envelope instead.
Number: 21 Created: 11 /26/2003
[4/12/04] The emergency access easement is only shown for the for the western entrance and needs to be carried all
the way around through the eastern entrance as well.
[11/26/03] Remove the "Existing 20' Gravel Driveway" label and replace with a "24' Emergency Access and Utility
Easement" label.
Number: 23 Created: 11/26/2003
l4/12/04] This comment applies to this round of review as well.
[11/26/031 Coordinate the comments among the various plan sets so that they all provide the same information.
L A G t—
Siguaiure 1 Datee�—
CIIECK 11i?�E IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat Site _� -
- Drainage Report / Other
Utility Redline Utility . Landscape
I'agc 1
Number: 24 Created: 11/26/2003
[4/12/04] Repeat comment.
[11126/03] Radial curb returns required at drive entrances.
Number: 25 Created: 11/26/2003
[4/12/04] The emergency access easement has changed since the first submittal. Please provide 25' inside and 50'
outside Wiring radii.
01/26/031 The emergency access easement requires 25' inside turning radii.
Topic: Plat
Number: 8
[4/12/04]
Created: 11/26/2003
[11/26103] From Technical Services: Boundary and legal close.
Topic: Utility
Number: 18 Created: 11/26/2003
[4112104] Repeat comment. Ditch signature block was only added to plat.
[11/26/03] Show the Ditch Company's easement on all plan sets and provide a New Mercer Signature block on the
various plan sets.
Number. 28 Created: 11/26/2003
(4/12/041 LCUASS requires a 1000' of preliminary design on either side of the project boundaries, however, you can
give ire just enough spot elevations along the flowline profile for me to verify the design. 25' on either side should do it.
[11/26/03] Provide a flowline profile for the design and construction of this development's frontage along Laporte.
Number: 30 Created: 11/26/2003
[4/12/04] Repeat comment.
[11/26/031 Show where the existing yard hydrant is being relocated to.
Number: 31 Created: 11/26/2003
[4112104] Repeat comment. Easements are still not shown correctly and they are not shown consistently between the
various plan sets.
[11/26/031 Correct the easement labels to read.
20' Emergency Access Easement
24' Emergency Access and Utility Easement
10' Drainage and Utility Easement
Number. 34
(4112/041 Repeat comment.
Created: 11/26/2003
[11/26/031 Detail Sheet- Remove detail 706 and replace with 707. Change the design in accordance with 707.
Number: 37
[41121041 Repeat comment.
Created. 11/26/2003
[11/26/031 Provide erosion control for Lot 2 and show on the Drainage & Erosion Control Sheets.
Number: 40 Created: 11/26/2003
[4/12/04] Repeat comment. Please show the building envelope on the plans and coordinate with PFA.
Page 2
Fro j ect Comments Sheet
Selected Departments
w f;i Fort Collins
Department: Water Wastewater
Date: November 26, 2003
Project: HIECKART SUBDIVISION -TYPE I (LUC)
All comments must be received Jy Steve Olt in Current Planning, no later than the
staff review meeting:
November 26, 2003
Note - Please identify your redlines for future reference
Issue Contact: Jeff Hill
Topic: General
Number: 2 Created: 11/24/2003
[11/24/03] Meter pit and curb stop may not be located with in public right of way. Place curb
stop 1 foot from rear of utility easerr=mt and meter pit no more than 2 feet beyond that.
Provide utility easernent for meter cit for lot 2 on lot 1. Label proposed 24 foot wide access
easement as access and utility. Mz;ntain 10 feet of separation on both sides of water and
sewer lines to utility easement.
Number: 3 Created: 11/24/2003
[11/24/03] Has 27-inch water main been pot holed? Pothole the existing water main now,
to determine if this area is in a lowered section for the ditch crossing. The water service may
not be located in lowered section of water main.
Number: 4 Created: 11/24/2003
[11/24/031 Provide existing sewer inverts in the existing manhole. Our records indicated that
an existing 8-inch stub and a sewer service already exist in the existing sanitary sewer
manhole (see print out attached to utility plans). Remove the existing 8-inch stub and install
new service in this existing location. Include note to grout opening closed with non -shrink
grout.
Number: 5 Created: 11/24/2003
[11/24/03] See site, landscape and utility plans for other comments.
Signature
Date
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat _ Site Drainage Report Other_
Utility _ Redline Utility Landscape
Page 1
[11/26/03] Contact PFA as soon as possible. Lot 2 may be out of service and must be sprinklered. Lot 2 may not meet
the 150' accessibility requirement.
Number: 56 Created: 4/12/2004
[4/12/041 Cover Sheet - Correction required to General Notes #41.
Number: 57 Created: 4/12/2004
14/12/041 Sheet 4 and 5 - Is the ditch company requiring rip rap for the end of 8" drain pipe or anything else or are they
ok with what's shown? I strongly suggest that you coordinate with the Ditch Co ASAP so that this doesn't become a
problem for you later on. The Ditch Co will be required to sign the mylars before I can route them for City signatures.
Number. 58 Created: 411212004
[4/12/041 Sheet 4 and 5 - spelling errors.
Number: 59 Created: 4/12/2004
[4/12/041 Dimension the utility easement shown on the west side of the east driveway entrance.
Number. 60 Created: 4/15/2004
[4/15/041 Complete Appendix E4 and submit with the next rounds of review. Any applicable items from E4 not shown
in the plans will become a new comment.
Page 3
iaProject Comments Sheet
Selected Departments
Citv of Fort Collins
Department: Water Wastewater
Date: April 16, 2004
Project: HECKART SUBDIVISION - TYPE I (LUC)
All comments must be received by Steve Olt in Current Planning, no later than the
staff review meeting:
April 14, 2004
Note - Please identify your redlines for future reference
Issue Contact: Jeff Hill
Topic: General
Number: 3
[4/16/04]
Created: 11 /24/2003
[11/24/03] Has 27-inch water main been pot holed? Pothole the existing water main
now, to determine if this area is in a lowered section for the ditch crossing. The water
service may not be located in lowered section of water main. There is an existing
14-inch ELCO water main in this area. Field locate and show on the utility plans.
Number: 4
[4/16/04]
Created: 11 /24/2003
[11/4/03] On lot 2, there is no need to show the location of the proposed house on
the site and landscape plans. It may change when it comes time to actually build.
Its location will be reviewed when the permit is applied for to be sure that it complies
with setbacks etc.
Number: 5 Created: 11 /24/2003
[4/16/04] Call out all clean outs in traffic areas as traffic rated and include a traffic
rated clean out detail.
[11/24/031 See site, landscape and utility plans for other comments.
Signature
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat _ Site Drainage Report Other_
Utility _ ��"Redline Utility Landscape
t% -/6 -O 4,
Date
Page t
STAFF PROJECT REVIEW
Ci h n( Kurt ('nllin�
Stewart & Associates Date: 04/20/2004
c,o Sack Blake
103 South Meldrum Street
Fort Collins, CO. 80526
Staff has reviewed your submittal for SECKART SUBDIVISION - TYPE I
(LU('), and we offer the following comments:
ISSUES:
Department: Current Planning Issue Contact: Steve Olt
Topic: Drainage
Number: 62 Created: 4/20/2004
[4/20/04] Gone Fischer of the New Mercer Ditch Company indicated
that this deve]opment request was previously reviewed by them.
Unless there is some substantial change to the plans the previously
given approval remains uchanged.
Topic: General
Nu_i:ber: 63 Created: 4/20/2004
[4/20/0V] Current Planning does not necessarily have to see a
building envelope on Lot 2 on the Site Plan. There are the necessary
easements on the lot along the west and south lines and any
scrzcturos will have to meet the regc_red building setbacks from
property iines. Planning strorgly recc:r_-r.ends that a building
e_:.'C ope not be shown on the subdivis-on plat because any future
change in the envelope v.,ould then require a replat of the lot.
Topic: Landscape
Number: 68 Created: 4/20/2004
[4/20/04] There are 2 lines shown near the northeast corner of the
property that are noz: labeled on the scan. What are they? Please see
the red lined plan.
Number: 69 Created: 4/20/2004
[4/20/04] Please remove the reference to the sewer cleanout from
the plan.
Number: 70 Created: 4/20/2004
[4/20/04] Seedless is misspelled in the Plant List on the plan.
Topic: Site
Numher: 64 Created: 4/20/2004
[4/20/04] There is a discrepancy on the size of Lot 2 between the
reference on the lot (12,690 s.f.) and in the Site Data (12,650
s.f.).
Number: 65 Created: 4/20/2004
[4/20/04] Are bore any existing drive-»ays in either of the access
easements?
Paee I
Number: 66 Created: 4/20/2004
[4/20/041 The reference to a sewer cleanout at the southeast side
of the existing house should be removed from the plan.
Number: 67 Created: 4/20/2004
[4/20/04] In the Site Data there is a reference to Existing Zoning
being LMN. That: is fine. There is also a reference to Proposed
Zoning being LMN. This should be removed from the plan. The existing
zoning is LMN and there is no reques:: to change the zoning;
therefore, only the Existing Zoning reference is sufficient.
Topic: Utility
Number: 61 Created: 4/20/2004
[4/20/04] Rob _Trish of Light & Power offered the following
comments:
a. The 5' wide utility & drainage easement on the west side of
the property is adequate only for Light & Power facilities. If
gas is going in this same easement then there will not be
enough separation between services. If this is the case then
the easement would need to be wider.
b. Please coordinate the meter location with Light & Power.
C. The property owner is responsible for electric development
charges and any necessary syste_n modification charges.
d. A pocket easement may be required from the property owner to
set a pad -mounted transformer to feed the additional electric
load. This transformer would need to be located within 10' of
a paved or truck accessible surface.
Department: Engineering
Topic: General
Number: 13
[4/12/04] Repeat comment.
Issue Contact: Susan Joy
Created: 11/26/2003
111/26/031 See Appendix E6 for scanability requirements. The
current plan sets do not meet the City's scanning standards.
Number: 14 Created: 11/26/2003
[4/12/04] In answer to your question of "Why 707 and not 706?
please see table 7-3 and 8-2 in LCJASS. All arterial streets
require radial curb returns with 20' radii on all driveway
entrances. Concrete to back of right of way. Please call if you
have questions in the future, it will save you a round of review.
[11/26/03] Please revise all plan sets to provide driveway access
to Laporte in accordance with detail 707.
Page 2
Number: 16 Created: 11/26/2003
[4/12/041 Repeat comment. Show building envelope, all sheets, all
plan sets.
[11/26/031 Do not show the actual building but provide a building
envelope instead.
Number: 21 Created: 11/26/2003
[4/12/041 The emergency access easement is only shown for the for
the western entrance and needs to be carried all the way around
through the eastern entrance as well.
111/26/031 Remove the "Existing 20' Gravel Driveway" label and
replace with a "24' Emergency Access and Utility Easement" label.
Number: 23 Created: 11/26/2003
14/12/041 This comment applies to this round of review as well.
111/26/031 Coordinate the comments a-.ong the various plan sets so
that they all. provide the same inforr;ation.
Number: 24 Created: 11/26/2003
14/12/041 Repeat comment.
[11/26/031 Radial curb returns r_eau'_red at drive entrances.
Number: 25 Created: 11/26/2003
[4/12/0,1] The emergency access easement has changed since the first
submittal. Please provide 25' inside and 50' outside turning radii.
[11/26/031 The emergency access easeent requires 25' inside
turning radii_
Topic: Plat
Number: 8 Created: 11/26/2003
[4/12/04]
[11/26/031 From Technical Services: Boundary and legal close.
Topic: Utility
Number: 18 Created: 11/26/2003
[4/12/04] Repeat comment. Ditch signature block was only added to
Plat.
[11/26/03] Show the Ditch Company's easement on all plan sets and
Provide a NewIo rcer Signature block on the various plan sets.
Number: 28 Created: 11/26/2003
[d/12/041 LCUASS requires a 1000, of preliminary design on either
side of Lho project boundaries, however, you can give me just enough
spot elevations along the flowline profile for me to verify the
design. 25' on either side should do it.
Page 3
[11/26/031 Provide a flowline profile for the design and
construction of this development's frontage along Laporte.
Number: 30 Created: 11/26/2003
(4/12/041 Repeat comment.
[11/26/031 Show where the existing yard hydrant is being relocated
to.
Number: 31 Created: 11/26/2003
[4/12/041 Repeat comment. Easements are still not shown correctly
and they are not shown consistently between the various plan sets.
[11/26/031 Correct the easement labels to read:
20' Emergency Access Easement
24' Emergency Access and Utility Easement
10' Drainage and Utility Easement
Number: 34 Created: 11/26/2003
[4/12/041 Repeat comment.
[11/26/03] Detail Sheet - Remove detail 706 and replace with 707.
Change the design in accordance with 707.
Number: 37 Created: 11/26/2003
[4/12/041 Repeat comment.
[11/26/031 Provide erosion control for Lot 2 and show on the
Drainage & Eros -ion Control Sheets.
Number: 40 Created: 11/26/2003
[4/12/041 Repeat comment. Please show the building envelope on the
plans and coordinate with Poudre Fire Authority (PFA).
[11/26/031 Contract PFA as soon as possible. Lot 2 may be out of
service and, if so, must be sprirklered. Lot 2 may not meet the
150' accessibility requirement.
Number: 56 Created: 4/12/2004
[4/12/041 Cover Sheet - Correction required to General Notes #41.
Number: 57 Created: 4/12/2004
[4/i.2/04] Sheet. 4 and 5 - Is the ditch company requiring rip rap
for the end of 8" drain pipe or anyth'_ng else or are they ok with
what's shown? I strongly suggest that you coordinate with the Ditch
Cc ASF;P so that this doesn't become a problem for you later on. The
Ditch Cc will be required to sign the mylars before I can route them
for City signatures.
Number: 58 Created: 4/12/2004
(4/12/041 Sheet 4 and 5 - spelling errors.
Paoe 4
Number: 59 Created: 4/12/2004
[4/12/04] Dimension the utility easement shown on the west side of
the east driveway entrance.
Numbcr: 60 Created: 4/15/2004
[4/15/04] Complete Appendix E4 and submit with the next rounds of
review. Any applicable items from F.4 not shown in the plans will
become a new comment.
Department: St:ormwater Utility Issue Contact: Wes Lamarque
Topic: Drainage
Numbcr: 41 Created: 11/26/2003
[4/12/04] Please revise notes on utility and drainage plans. See
rodlined plan.
The inlet and storm sewer need to be improved with this PIP. A 5-
foot Type-R inlet with a 15-inch diameter outlet pipe is required to
replace the existing inlet and pipe. Please call G1es Lamarque at
416-2418 if you have nay questions.
Topic: Erosion/Sediment Control
Number: 55 Created: 4/12/2004
Please add in text that the min -mum 51,000 erosion control escrow
will be provided.
Department: Water Wastewater
Topic: General
Number: 3
[4/16/04]
Issue Contact: Jeff Hill
Created: 11/24/2003
111/24/031 Has 27-inch water main been pot holed? Pothole the
existing water main now, to determine i_` this area is in a lowered
sect i_o❑ for the dirt-- crossing. The water service may not be located
.in Icv:ered sect_on of water mai^,. There is an existing 14-inch ELCO
water main in this area. Filed locate and show on the utility
plans.
Number: 4
[4/16/04]
Created: 11/24/2003
111/4/031 On lot 2, there is no need to show the location of the
proposed house on the site and landscape plans. It may change when
it comes time to actually build. Its location will be reviewed when
the permit is applied for to be sure that it complies with setbacks
etc.
Number: 5 Created: 11/24/2003
14/1.6/041 Call out all clean outs in traffic areas as traffic rated
and include a traffic rated clean out detail_.
111/24/031 See site, landscape and utility plans for other
comments.
Page 5
The following comments were expressed at staff review on April 14,
2004:
Engineering:
1. The driveway curb cuts onto Laporte Avenue must be radial cuts.
2. The New Mercer Ditch Company must sign the subdivision plat and
utility plans.
3. Where is the existing hydrant going to be relocated?
4. Rip -rap may be needed at the end of the drainage pipe where it
outlets into the New Mercer Ditch. Will the ditch company allow
this?
5. A building envelope must be shown on the utility plans for Lot
2.
Water/Wastewater:
1. Services must go all the way to a manhole. No 8" main can be in
the drive.
Stormwater:
1. There is an erosion control escrow fee of $1,000 that must be
paid.
2. The New Mercer Ditch Company must approve the rip -rap that is
needed at the outlet end of the drainage pipe.
3. There are inconsistencies in notes on the plans that must be
revised.
This completes staff (and outside reviewing agencies) review and
comments at this time. Additional corm.ents and red -lined plans may
be forthcoming. Another round of staff review is determined to be
necessary be -'ore mylars can be subm__ted. This proposal is subject
to the 90-day revision re -submittal requirement (from the date of
this comment letter, being April 20, 2004) as set forth in Section
2.2.11(A) of the Land Use Code. Be sure and return all of your red -
lined plans when you re -submit. The num.�-.er of copses of each
document to re -submit is shcom on the attached Revisions Routing
Sheet.
Pave 6
If you have any questions regarding these issues or any other issues
related to this project, please feel free to call me at (970) 221-
6750.
You s Truly,
Steve Olt
City Planner
cc: Susan Joy
Frank Heckart
Current Planning File #35-03
Page 7
REVISION
REM '84MAY
COMMENT SHEET
DATE: May 5, 2004 TO: Technical Services
PROJECT: #35-03 Heckart Subdivision PDP - Type I (LUC)
All comments must be received by Steve Olt no later than the staff
review meeting:
May 19, 2004
No Comment
Problems or Concerns (see below or attached)
**PLEASE IDENTIFY YOUR REDLINES FOR FUTURE
REFERENCE**
Name (please print) Date
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat Site Drainage Report _Other
Utility _Redline Utility Landscape
Project Comments Sheet
�u01 Port Collins
Selected Departments
Department: Engineering
Date: December 2, 2003
Project: HECKART SUBDIVISION - TYPE I (LUC)
All comments must be received by Steve in Current Planning, no later than the
staff review meeting:
November 26, 2003
Note - Please identify your redlines for future reference
Issue Contact: Susan Joy
Topic: General
Number: 12 Created: 11/26/2003
[11/26/03] This development is responsible for the design and construction of Laporte along their frontage. Please
revise all plan sets to include this requirement.
Number: 13 Created: 11/26/2003
[11/26/031 See Appendix 1-6 for scanability requirements. The current plan sets do not meet the City's scanning
standards.
Number: 14 Created: 11/26/2003
[11/26/031 Please revise all plan sets to provide driveway access to Laporte in accordance with detail 707.
Number: 15
(11/26/031 Provide utility easements to Lot 2.
Created: 11/26/2003
Number: 16 Created: 11/26/2003
[11/26/03] Do not show the actual building but provide a building envelope instead.
Number: 17 Created: 11/26/2003
[11/26/031 The proposed sidewalk shown along Laporte needs to tie into existing. Taper and terminate as shown on
the redlines.
Number: 18 Created: 11/26/2003
(11/26/03J Show the Ditch Company's easement on all plan sets and provide a New Mercer Signature block on the
various plan sets.
Number: 23 Created: 11/26/2003
[11/26/031 Coordinate the comments among the various plan sets so that they all provide the same information.
Number: 36
_ V/ , ;. Created: 11/26/2003
Sigaanme
Date
CHECK HERE IF -YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat _ Site Drainage Report Other_
_Utility _ Redline Utilitv I Landscape
Page 1
Project Comments Sheet
1r' l Selected Departments
Citv of Fort Collins
Department: Stormwater Utility
Date: May 20, 2004
Project: HECKART SUBDIVISION - TYPE I (LUC)
All comments must be received by Steve Olt in Current Planning, no later than the
staff review meeting:
May 19, 2004
Note - Please identify your redlines for future reference
Issue Contact: Wes Lamarque
Topic: Utility
Number: 79 Created: 5/20/2004
Please provide a signature block for the ditch company on the utility plans.
t —0-r
Date
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat _ Site Drainage Report Other
Utility _ Redline Utility Landscape
Page t
C)J
Se->o-. �Jlij
L ,.a
Project Comments Sheet
Selected Departments
City of Fort Collins
Department: Engineering
Date: May 24, 2004
Project: HECKART SUBDIVISION - TYPE I (LUC)
All comments must be received by Steve Olt in Current Planning, no later than the
staff review meeting:
May 19, 2004
Note - Please identify your redlines for future reference
Issue Contact: Susan Joy
Topic: General
Number: 16 Created: 11/26/2003
[5/12/041 Repeat comment. Show and label building envelope, all plan sets.
[4/12/041 Repeat comment. Show building envelope, all sheets, all plan sets.
[11/26/031 Do not show the actual building but provide a building envelope instead.
Number: 31 Created: 11/26/2003
[5/12/041 Repeat comment. Easements are not shown consistently between the various plan sets. The easements are
shown differently and labeled differently on the plat, utility, site, and landscape plans. All of them need to
match.
[4/12/041 Repeat comment. Easements are still not shown correctly and they are not shown consistently between the
various plan sets.
[11 /26/03] Correct the easement labels to read:
20' Emergency Access Easement
24' Emergency Access and Utility Easement
10' Drainage and Utility Easement
Topic: Plat
Number: 8 Created: 11/26/2003
[5/12/041 [4/121041 [11/26/03] From Technical Services: Boundary and legal close.
Topic: Utility
Number: 18 Created: 11/26/2003
[5/12/04) Repeat comment. Please provide a ditch company signature block on the utility sheets.
a letter of intent from the ditch company prior to being allowed to go to hearing.
(4112/041
signature block was only added to plat.
Will need to provide
2 q
Dat
IF YOU WISH TO RECEIVE COPIES OF REVISIONS
I Plat _ I Site Drainage Report
-Z Utility 5C Redline Utility I Landscape
Other
Page 1
[11/26/03] Show the Ditch Company's easement on all plan sets and provide a New Mercer Signature block on the
various plan sets.
Number: 40
[5/12/041 Repeat comment.
Created: 11 /26/2003
[4/12/041 Repeat comment. Please show the building envelope on the plans and coordinate with PFA.
[11/26/031 Contact PFA as soon as possible. Lot 2 may be out of service and must be sprinklered. Lot 2 may not meet
the 150' accessibility requirement.
Number: 71 Created: 5/1212004
[5/12/041 Sheet 4 - Please label the curb side of the ramps at the driveway entrances so that there is no confusion in
the field when this is constructed.
Number: 72 Created: 5/12/2004
[5/12104] Sheet 4 - Please hatch the street cut using a large diagonal for scanability.
Number: 73 Created: 5/12/2004
[5/121041 Sheet 5 - Label the building envelope. Remove the duplicated word in the rip rap label.
Number: 74 Created: 5/12/2004
[5/12/041 Please dimension the narrowest width of the emergency access drive aisle. Is it less than PFA's
requirement?
Page 2
" STAFF PROJECT REVIEW
(Wily al PortCollins
Stewart & Associales Date: 06/02/2004
c/o Jack RIake
103 South Meldrum Street
Fort Collins, CO. 80526
Staff has rcvic�wod your submittal for. HECKART SUBDIVISION - TYPE I
and we offer the following comments:
ISSUES:
Department: Engineering
Topic: General
Number: 16
[5/12/041 Repeat comment
plan sets.
4/12/041 Repeat comment
plan sets.
Issue Contact: Susan Joy
Created: 11/26/2003
Show and label building envelope, all
Show building envelope, allsheets, all
[II/26/03] Do not show the actual building but provide a building
envelope instca.d.
Number: 31 Created: 11/26/2003
[5/12/041 Repeat comment. Easements are not shown consistently
betwce: the various plan sets. The easements are shown
differently and labeled differently on the plat, utility,
silo, and landscape plans. All of them need to match.
[A/I2/C41 Repeat comment. Easements are still not shown correctly
and they are not shoum consistent-y between the various plan
sets.
[1l/26/031 Correct the easement labels to read:
20' Emergency Access Easement
2Q' ]!mergncy Access and Utility Easement
10' Prainngc and Utility Iasement
Topic: Plat
Numl)c:: 8 Created: 11/26/2003
[5/12/A4] [4/12/041 [11/26/03; From Technical Services: Boundary
and legal ctose.
Pagt I
Topic: Utility
Number: 18 Created: 11/26/2003
[5/12/041 Repeat continent. Please provide a ditch company signature
block on the uti].i.ty sheets. Willneed to provide a letter of
intent from the ditch company prior to being allowed to go to
h( aring.
[4/12/04] Repeat comment. Ditch signature block was only added to
plat.
111/26/031 Show the Ditch Company's easement on all plan sets and
provide a New Mercer Signature block on the various plan sets.
Number: 40
[5/12/04] Repeat comment.
Created: 11/26/2003
[4/12/041 Repeat comment. Please show the building envelope on the
plans and coordinate with PFA.
[11/26/03] Contact PFA as soon as possible. Lot 2 may be out of
service and must be sprinklered. Lot 2 may not meet the 150'
accessibility requirement.
Number: 71 Created: 5/12/2004
[5/,12/04] Sheet 4 - Please label the curb side of the ramps at the
driveway entrances so that there is no confusion in the field when
this is constructed.
Number: 72 Created: 5/12/2004
15/1.2/04] Sheet 4 - Please hatch the street cut using a large
diagonal for scanability.
Number: 73 Created: 5/12/2.004
[5/12/041 Sheet 5 - Label the building envelope. Remove the
duplicated word in the rip rap label_.
Number: 74 Created: 5/12/2004
[5/12/041 Please dimension the narrc:aest width of the emergency
access drive aisle. Is it less than PFA's requirement?
Department: Light & Power Issue Contact: Rob Irish
Topic: Utility
Number: '/5 Created: 5/17/2004
[5/17/041 The utility & drainago easement on the west side of
thy, property is only adequate for Light & Power facilities. If gas
or some other utility is going in this same casement there will not
be enoueh separation. The easement ,pill need to be wider.
Numbor: 76 Created: 5/17/2004
[5/17/04] Owne- will need to coordinate meter location with Light &
Power. Owner wil1. be responsible for electric development charges &
system modification charges if applicable.
Page 2
Number: 77 Created: 5/17/2004
[S/17104] Packet casement maybe required by owner to set pad -
mounted transformer to feed additional load. This transformer would
need to be -located within 10' of a paved or truck accessible
surface.
Department: Stormwater Utility Issue Contact: Wes Lamarque
Topic: Utility
Number: '79 Created: 5/20/2004
Please provide a signature block for the ditch company on the
utility plans.
Department: Water Wastewater Issue Contact: Jeff Hill
Topic: Utility
Number_: 78 Created: 5/18/2004
15/18/041 No comments
Be sure and return all of your redlined plans when you re -submit.
If you have any questions regarding these issues or any other issues
related to this project, please feel free to call me at 221-6341.
Yours Truly,
Steve Olt,
City Planner
Cc: usan Joy
Hob Irish
Prank Hecka-t
Page 3
[1 tlf3/03) Is the placement of the Emergency Access drive acceptable to PFA? The current cenE iuration has th^ fi,e
trucestaging approximately 50' away from the bu,, ding. -haT leaves only 100' to the back of the furthest part of the
building in order to meet fire code. Is the buildings eventuai : Iacement going to meet that requirement or does the
eme.:,ency arive need to be aciusted now?
Topic: Landscape
Number: A Created: 11/26/2003
[11/26/031 Show all utilities on the Landscape Plan,
Topic: Plat
Number: 8 Created: 11 /26/20C 3
[11/26/031 From Technical Services: Boundary and legal close.
Number: 9 Created: 11 /26/2003
[11/26/031 From Technical Services: What about the New Mercer Ditch at the NE corner cf Lot 1? You need to
show the Ditch Company's easment and provide a signature block for them to sign off on the plat.
Number: 10 Created: 11 /26/2003
[11/26/031 From Technical Services: There needs to be a utility easement across Lot 1 to :service Lot 2,
Number: 11 Created: 11 /26/2003
[11/26/031 From Technical Services: The text does not meet City scanning standards.
Number: 24 Created: 11 /26/2003
[11/26/03) Radial curb returns required at drive entrances.
Number: 25 Created: 11 /26/2003
[11/26/031 The emergency access easement requires 25' inside turning radii.
Number: 26 Created: 11 /26/2003
[11/26/03] Provide utility easements to Lot 2.
Number: 45 Created: 12/2/2003
[12/2/031 Provide the Notice of Other Documents, see attached.
Topic: Site
Number: 19 Created: 11 /26/2003
[11/26/031 Remove contou,s and utilities.
Number: 20 Created: 11 /26/2003
[11/26/03] Spell out all UE and DE labels to read "Utility Easement" and "Drainage Easement".
Number: 21 Created: 11 /26/2003
[l 1/26/03] Remove the "Existing 20' Gravel Driveway' label and replace with a "24' Emergency Access and Utility
Easement" label.
Topic: Utility
Number: 27 Created: 11 /26/2003
[11/26/031 Sheet 3 - Provide a curve table and dimensions for the sidewalk along Laporte so that they can lay this out
in the field.
Number: 28 Created: 11 /26/2003
[11/26/031 Provide a flowline profile for the design and construction of this development's frontage along Laporte.
Number: 29
Page 2
Created: 11 /26/2003
[11/26/031 Remove and replace the area inlet shown in Laporte with a Type 3 inlet. Provide the appropriate details and
approximate street cut. Provide the street cut note:
Limits of street cut are approximate. Final limits are to be determined in the field by the City Engineering Inspector. All
repairs to be in accordance with City street repair standards.
Number: 30 Created: 11/26/2003
[11/26/03) Show where the existing yard hydrant is being relocated to.
Number: 31 Created: 11/26/2003
[11/26/031 Correct the easement labels to read:
20' Emergency Access Easement
24' Emergency Access and Utility Easement
10' Drainage and Utility Easement
Number: 32 Created: 11/26/2003
[11/26/031 What's happening with the sewer cleanout shown on Sheet 3? Does it tie into something? Is it being
removed? Abandoned?
Number: 34 Created: 11/26/2003
[11/261031 Detail Sheet - Remove detail 706 and replace with 707. Change the design in accordance with 707.
Number: 35 Created: 11/26/2003
[11/26/031 Place the Construction Notes on Sheet 6 behind the General Notes - in other words, Sheet 6 should be
Sheet 2.
Number: 37 Created: 11/26/2003
[11/26/031 Provide erosion control for Lot 2 and show on the Drainage & Erosion Control Sheets.
Number: 40 Created: 11/26/2003
[111/26/031 Contact PFA as soon as possible. Lot 2 may be out of service and must be sprinklered. Lot 2 may not meet
the 150' accessibility requirement.
Page 3
6QSTAFF PROJECT REVIEW
Cilp ui Purt Collin+
Stewart & Associates Date: 12/3/2003
c/o Jack Blake
103 South Meld: -um Street
Fort Collins, CO. 80521
Staff has reviewed your submittal `or HECKART SUBDIVISION - TYPE I
(LUC), and we offer the following comments:
ISSUES:
Department: Current Planning Issue Contact: Steve Olt
Topic: Landscape
Number: 50 Created: 12/3/2003
[12/3/031 Please see red -lined Landscape Plan for Current Planning
comments.
Number: 51 Created: 12/3/2003
[12/3/03) The 2 proposed Autumn Purple Ash trees to be used as
street trees along LaPorte Avenue are not on the City's Approved
Street Tree List. Please make another selection from the list.
Topic: Plat
Number: 46 Created: 12/3/2003
[12/3/031 Len Hilderbrand of Xcel Energy offered the following
comments:
a. The proposed 5' utility easements are not adequate. If the
owner requests natural gas then the 5' easements would need to
be unencumbered.
b. No fences, trees, or bushes can obstruct the installation of
gas lines.
C. Is it possible to make the access drive a utility easement?
Number: 47 Created: 12/3/2003
[12/3/031 Rob Irish of City Light & Power offered the following
comments:
a. Power for this property will come from LaPorte Avenue.
b. The owner will need to coordinate the electric meter location
with Light & Power.
C. Any modifications or relocations of existing electric
facilities will be at the property owner's expense.
d. The property owner will be responsible for residential
development charges.
Page i
Number: 48 Created: 12/3/2003
[12/3/03] There appears to be an error in the east property lines
of Lot 1 and the road right-of-way. The two distances of 319.98, +
42.00' do not add up to 350.001. They would equal 361.981.
Topic: Site
Number: 49 Created: 12/3/2003
[12/3/03] Please see red -lined Site Plan for Current Planning
comments.
Department: Engineering Issue Contact: Susan Joy
Topic: General
Number: 12 Created: 11/26/2003
[11/26/031 This development is responsible for the design and
construction of LaPorte Avenue along their frontage. Please revise
all plan sets to include this requirement.
Number: 13 Created: 11/26/2003
[11/26/031 See Appendix E6 for scanability requirements. The
current plan sets do not meet the City's scanning standards.
Number: 14 Created: 11/26/2003
[11/26/031 Please revise all plan sets to provide driveway access
to LaPorte Avenue in accordance with detail 707.
Number: 15 Created: 11/26/2003
[11/26/031 Provide utility easements to Lot 2.
Number: 16 Created: 11/26/2003
[11/26/031 Do not show the actual building but provide a building
envelope instead.
Number: 17 Created: 11/26/2003
[11/26/031 The proposed sidewalk shown along LaPorte Avenue needs
to tie into existing. Taper and terminate as shown on the redlines.
Number: 18 Created: 11/26/2003
[11/26/031 Show the Ditch Company's easement on all plan sets and
provide a New Mercer Signature block on the various plan sets.
Number: 23 Created: 11/26/2003
[11/26/03] Coordinate the comments among the various plan sets so
that they all provide the same information.
Number: 36 Created: 11/26/2003
[11/26/031 Is the placement of the Emergency Access drive
acceptable to PFA? The current configuration has the fire truck
staging approximately 50' away from the building. That leaves only
100' to the back of the furthest part of the building in order to
meet fire code. Is the buildings eventual placement going to meet
that requirement: or does the emergency drive need to be adjusted
now?
Page 2
Topic: Landscape
Number: 39 Created: 11/26/2003
[11/26/031 Show all utilities on the Landscape Plan.
Topic: Plat
Number: 8 Created: 11/26/2003
[11/26/03] From Technical Services: Boundary and legal close.
Number: 9 Created: 11/26/2003
[11/26/031 From Technical Services: What about the New Mercer
Ditch at the NE corner of Lot 1? You need to show the Ditch
Company's easement and provide a signature block for them to sign
off on the plat.
Number: 10 Created: 11/26/2003
[11/26/03] From Technical Services: There needs to be a utility
easement across Lot 1 to service Lot 2.
Number: 11 Created: 11/26/2003
[11/26/031 From Technical Services: The text does not meet City
scanning standards.
Number: 24 Created: 11/26/2003
[11/26/03] Radial curb returns required at drive entrances.
Number: 25 Created: 11/26/2003
[11/26/031 The emergency access easement requires 25' inside
turning radii.
Number: 26 Created: 11/26/2003
(11/26/031 Provide utility easements to Lot 2.
Number: 45 Created: 12/2/2003
[12/2/03] Provide the Notice of Documents, see attached.
Topic: Site
Number: 19 Created: 11/26/2003
[11/26/031 Remove contours and utilities.
Number: 20 Created: 11/26/2003
[11/26/031 Spell out ail UE and DE labels to read "Utility
Easement" and "Drainage Easement".
Number: 21 Created: 11/26/2003
[11/26/031 Remove the "Existing 20' Gravel Driveway" label and
replace with a "24' Emergency Access and Utility Easement" label.
Topic: Utility
Number: 27 Created: 11/26/2003
[11/26/03] Sheet 3 - Provide a curve table and dimensions for the
sidewalk along LaPorte Avenue so that they can lay this out in the
field.
Page 3