HomeMy WebLinkAboutHELLENIC PLAZA - Filed CS-COMMENT SHEETS - 2009-11-30Selected Issues Report
ramie Date: 11 /23/20 9
C: tvof fort C:ollix'ts
HELLENIC PLAZA PDP (635 S. SHIELDS ST.) - TYPE I and Final
Plans
SELECTION CRITERIA: Department = Engineering; Status = All
ISSUES:
Department: Engineering Issue Contact: Randy Maizland
Topic: Engineering
Number:34 Created:3/13/2007 Resolved
[3/13/07] Utility Plan Cover Sheet: Please revise the cover sheet per the redline comments
(date, vicinity map, sheet index, geotech info) Remove the typical street section from the
cover sheet. Please add the plat to the Utility Plan set for reference as sheet 3.
Number:35 Created:3/13/2007 Unresolved
[4/26/07] Carry over comment. Design looks good, please prepare and submit local portion
cost estimate for review.
[3/13107] You will need to submit a construction cost estimate for the Coy Street ultimate
design for the frontage obligation. This cost will be collected as a cash in lieu payment and
provided in the development agreement.
Number:36 Created:3/13/2007 Resolved
[3/13/07] Please submit a formal variance request for driveway seperation as listed on
General Note 48. Both variance requests have been discussed prior to the submittal and will
be approved.
Number:37 Created:3/13/2007 Resolved
[3/13/071 Grading Plan General: It has been mentioned that the building layout and
detention areas may change to provide additional detention and water quality. Please revise
the Grading Plan per the preliminary review comments provided on the redlines. Label all
proposed new walks with dimensioning. Call out all new access ramps and curb drains in
the ROW with details.
Number:38 Created:3/13/2007 Unresolved
[3/13/07] For the access on Shields, please provide additional flow line spot elevations and
a cross section on the Grading Plan sheet. Show that a minimum 0.5 percent gradient is
maintained across the access. Please provide typical construction details for all on -site
drainage improvements such as infall and outfall curb and gutter, pans, drains etc....
Number:39 Created:3/13/2007 Resolved
[3/13/07] Please coordinate with stormwater to determine if a drainage easement needs to
be didicated for any detention areas or drainage improvements.
Number:40 Created:3/13/2007 Resolved
[3/13/07] Please clearly show and label the limits of ROW on the Utility Plan sheet.
Number:41 Created:3/13/2007 Resolved
[3/13/07] Please label and dimension new proposed sidewalks on the Utility Plan Sheet.
Page 1
Number:42 Created:3/13/2007 Resolved
[3/13/07] Call out all proposed ramps and all drainage structures within the ROW with
standard details.
Number:43 Created:3/13/2007 Resolved
[3/13/07] Please provide proposed signing and striping for the Shields controlled access on
the utility Plan sheet.
Number:44 Created:3/13/2007 Resolved
[3/13/07] The proposed sidewalk on Shields should tie back into the existing attached walk
to the north. Please show this on all applicable plan sheets.
Number:45 Created:3/13/2007 Resolved
[3/13/07] The sidewalk connection from Coy Street to Birch Street should be constructed
within a public access easement. Please dedicate this easement on the Plat and show and
label the easement on the Utility Plan sheet.
Number:46 Created:3/13/2007 Resolved
[3/13/07] The 90 degree intersection bulbs on Coy Street shall be designed per LCUASS
standard 7-24. If this standard design as a significant negative impact on the Hellenic Plaza
site, we may be flexible with parkway and sidewalk locations/dimensions to make it fit well.
Number:47 Created:3/13/2007 Resolved
[3/13/07] Please provide North and South flowline profiles In your preliminary design. See
additional redline comments regarding profile slope at the sag curve and inlet location.
Number:48 Created:3/13/2007 Resolved
[3/13/07] Please clearly show existing and prposed limits of ROW on the Coy Street design.
Number:49 Created:3/13/2007 Resolved
[3/13/07] The typical street section shown with rollover curb and gutter requires a total ROW
dedication of 53 feet per the LCUASS standard. Please dedicate additional ROW to
accommodate rollover C&G or use vertical C&G.
Number:50 Created:3/13/2007 Resolved
[3/13/07] Please call out the proposed concrete pan and sidewalk inlet with details on the
street design. Label and dimension sidewalks, parkway and curb to curb pavement on plan
view
Number:51 Created:3/13/2007 Resolved
[3/13/07] Some of the text on the typical/standard details is difficult to read. Will not copy or
scan well.
Number:54 Created:3/13/2007 Unresolved
[4/26/07] Please pay with final plan review $1,081.75. Thank you.
[3/13/07] The PDP submittal review fee was not calculated correctly. An additional $81.75 is
due. Please submit this payment prior going to hearing.
Number:64 Created:3/13/2007 Unresolved
[4/26/07] Field meeting resulted in approval of 6 foot wide attached walk along Birch ...
matches sidewalk on south side of street.
Page 2
[3/13/071 The sidewalk on Birch does not meet LCUASS standards for local residential
streets. Minimum 6 foot parkway and 4.5 foot detached sidewalk.
Number:65 Created:3/13/2007 Unresolved
[4/26/07] Please show cross slope at cross walk on Shields Street access and provide a
cross section or adequate elevation data on the plan to verify that a monolithic pan will be
poured to carry flows south along Shields with a minimum of 0.5 percent fall.
[3/13/07] Please calculate and show the cross slope on the access to Shields at the cross
walk. 2% is the maximum cross slope allowed under ADA guidelines.
Number:81 Created:4/26/2007 Unresolved
[4/26/07] The Plat is showing an existing 10 foot wide ditch easement running east -west
from Shields Street. If you wish to vacate this easement by the Plat, the ditch owner will
need to sign the final plat and a standard vacation note must be added to the plat. You may
also record a termination of easement by separate document signed by the ditch owner.
Either way, the City will need at a minimum, a letter of intent from the ditch owner stating
that the ditch easement is no longer needed or desired. This must be resolved prior to
scheduling a hearing for the project.
Number:82 Created:4/26/2007 Unresolved
[4/26/071 Please provide addition spot - flowline elevation data at the Shields access to
show drainage being conveyed at 0.5 percent min. in a monolithicly poured pan. You can
also provide a simple cross section at this location to show how this is to be constructed.
Number:83 Created:4/26/2007 Unresolved
[4/26/07] Please extend arrows from standard street cut note to all areas in the ROW with
propoed street cuts (access points)
Number:84 Created:4/26/2007 Unresolved
[4/26/07] The north and south flow line sag curves for the Coy Street design do not meet
LCUASS standards. Minimum K values must be 30 or greater. Lengthening the vertical
curve should solve the problem. See LCUASS Table 7-3.
Number:85 Created:4/26/2007 Unresolved
[4/26/07] Please submit a revised plan for any scheduled hearings. Thank you.
Number:98 Created:12/11/2007 Resolved
[12/11/07] The Sheet Index on the Utility Plan set indicates a Plat will be included for
reference but it is not in the plan set. Please insert the final plat with your next submittal.
Number:99 Created:12/11/2007 Resolved
[12/11/07] Update the date/year on the cover sheet of the Utility Plan.
Number:100 Created:12/11/2007 Resolved
[12/11/07] The plotter seems to be having some problems. Unwanted lines though text
etc... Please correct for any final plan submittals & mylar plotting.
Number:101 Created:12/11/2007 Resolved
[12/11/07] The driveway cross section A-3 on the Grading sheet is not entirely clear.
Please show the profile cross section and dimensions only where the section is taken. Do
not include background information.
Page 3
Number:102 Created:12/11/2007 Resolved
[12/11/07] Please clearly show label and dimension the limits of R.O.W. and Utility
Easements on all of the utility Plan sheets (TYP). See redlines.
Number:103 Created:12/11/2007 Resolved
[12/11/07] The sidewalk on Birch Street does not fit entirely in the R.O.W. therefore, you will
need to either dedicate additional R.O.W. or dedicate the easement behind the R.O.W. as
Utility and Access to include the sidewalk. The Plat, Utility Plans and Site Plan should all
reflect this consistently. See redlines for clarification.
Number:104 Created:12/11/2007 Resolved
[12/11/07] The proposed sidewalk on Shields is not shown in the correct location. The
sidewalk should be shown in the ultimate location with the back of sidewalk at the R.O.W.
limits. If the street is widened to the ultimate condition (constrained arterial 102" wide) the
sidewalk will not need to be reconstructed in the future. The ramp on the south side of the
Shields access should be lined up with the cross walk and ultimate sidewalk rather than
skewed into the site. The directional ramp at the Shields/Birch intersection should be
relocated to line up with the ultimate sidewalk.
Number:105 Created:12/11/2007 Resolved
[12/11/07] Please remove any landscape layers from the Utility Plan set. This can all be
shown on the Landscape Plan and adds clutter to an already busy plan.
Number:106 Created:12/11/2007 Resolved
[12/11/07] The stop bar on the Shields egress access should be shown more perpendicular
to the path of travel. It will not work well as shown and should be rotated at the north end.
Number:107 Created:12/11/2007 Resolved
[12/11/07] Construction sequencing information is not required on the Utility Plan set.
Please remove.
Number:108 Created:12/11/2007 Resolved
[12/11/07] Please clearly label & dimension the Coy Street R.O.W. and U.E. on the
Grading, Utility and Street Design sheets (TYP).
Number:109 Created:12/11/2007 Resolved
[12/11/07] There are a couple walls shown on the northerly boundary. Please label them
consistently throughout the plans and indicate if they are retaining at all. If retaining, we will
want a cross section and elevations TW/BW shown and a note that any retaining walls over
30" require a separate building permit.
Number:110 Created:12/11/2007 Pending
[2/19/08] The Conduit note was completely removed on the current plan ? Please explain
why the 4" conduit was removed from the reduced 3 foot utility easement behind the ROW.
[12/11/07] The Utility Plan sheet (sheet 4) shows a note to provide two 4 inch conduits.
You will need to show the exact location of these conduits more clearly and where they
extend to.
Page 4
Number:111 Created:12/11/2007 Resolved
[12/11/07] The south flowline profile shows a single point grade break that exceeds the max
allowable of 0.4 percent. Please provide a series of grade breaks or vertical curve.
Number:112 Created:12/11/2007 Resolved
[12/11/07] Please fix all line over text conflicts in the Coy Street design profile. Mask text if
needed. (TYP)
Number:113 Created:12/11/2007 Resolved
[12/11/07] Please clearly show, label and dimension the Coy Street R.O.W. and U.E. on the
Coy design plan view.
Number:114 Created:12/11/2007 Resolved
[12/11/07] The information shown on the Coy Street design centerline profile at the pan is
not clear to me. You are showing it coming in at .05 percent and also 3.5 percent on both
sides. Show only the proposed slopes at the centerline.
Number:115 Created:12/11/2007 Resolved
[12/11/07] Please fix the text on the LCUASS details on sheet 7. The text is too heavy and
will not scan or copy well.
Number:116 Created:12/11/2007 Pending
[2/19/08] The Site plan is not consistent with the Utility Plan set with regards to the ramp
alignment and Stop Bar location at the right -out only access on Shields. Please revise the
Site Plan to match the Utility Plan prior to producing mylars.
[12/11/071 Please see redline comments on the Plat and Site plan and verify that all of the
plans are consistent with each other.
Number:117 Created:12/11/2007 Pending
[2/19/08] Still under review by Street Oversizing. Please contact Matt Baker for status of
review. I will need to his review completed before I can finalize the development agreement.
[12/11/07] The Coy Street local portion cost estimate is currently still under review by Street
Oversizing. This will be completed prior to final compliance and development agreement
preparation.
Number:128 Created:2/19/2008 Pending
[2/19/08] The cross section to the north shows that proposed grading will be done off -site
on private property, north of the 6" curb. If off -site grading is proposed or needed then an
easement will need to be obtained prior to plan approval. Please revise the plans to show
no off -site grading or provide a signed deed of dedication from the property owner.
Number:129 Created:2/19/2008 Pending
[2/19/08] There are some labeling errors. Please see the redlines for clarification.
Number:130 Created:2/19/2008 Pending
[2/19/08] If all issues can be addressed I am OK with going to mylar at this point. Please
see comments from other departments to determine if they are also ready for mylar. Make
sure to submit ALL redlines with any mylar prints.
Page 5
Topic: Tech. Services
Number:89 Created:5/2/2007 Unresolved
[5/2/07] Many line over text conflicts on the Site and Landscape Plans. Please see redlines
for clarification and correct with final plan submittal.
Page 6
Selected Issues Report
Cite of T�r>xt C"c.�dliria
Date: 11 /23/2009
HELLENIC PLAZA PDP (635 S. SHIELDS ST.) - TYPE I and Final
Plans
SELECTION CRITERIA: Department = Transportation Planning; Status = All
ISSUES:
Department: Transportation Planning Issue Contact: David Averill
Topic: Engineering
Number:55 Created:3/13/2007 Unresolved
[3/13/07] The 4.5' attached walk on Birch will not be allowed. The LCUASS standard for a
residential local requires a 4.5' detached walk with a 6' parkway at a minimum.
Number:56 Created:3/13/2007 Unresolved
[5/4/07]
[3/13/07] 1 think the crossing of the drive aisle/exit might need to be slightly reconfigured for
pedestrian safety. We will need to discuss this at staff review.
Number:57 Created:3/13/2007 Unresolved
[3/13/07] The alternative modes analysis in the TIS is acceptable.
Page 1
== STAFF PROJECT REVIEW
City of Fort Collins
Don Brookshire Date: 03/19/2007
Eastpoint Studio, LLC Corrected.
552 Kinnikinnik Ct.
Windsor, CO 80550
Staff has reviewed your submittal for HELLENIC PLAZA PDP (635 S. SHIELDS ST.)
- TYPE I, and we offer the following comments:
ISSUES:
Department: Current Planning Issue Contact: Shelby Sommer
Topic: Building Elevations
Number: 32 Created: 3/8/2007
[3/8/07] The building elevations show 2 west elevations but no east elevation.
Please correct. Corrected.
Topic: General
Number: 1 Created: 2/27/2007
[2/27/07] The following departments have indicated that they have no concerns with
this proposal: Park Planning, Water Conservation, Comcast, GIS, Neighborhood
Services, ROW Planning. So noted.
Number: 6 Created: 3/1/2007
[3/1/07] Rick Lee (Building Department): Please see attached codes and standards
we will enforce. Please schedule the required pre -submittal meeting with the
Building Department as noted on the attachment. Meeting held.
Number: 17 Created: 3/7/2007
[3/7/07] Bonnie Ham (US Postal Service): Mailboxes located on the southeast
corner of the buildings looks good. So noted.
Number: 33 Created: 3/8/2007
[3/8/07] General comment for all plans (site, landscape, utility, lighting) - page
numbering is inconsistent. Architectural plans re -numbered.
Topic: Landscape plan
Number: 19 Created: 3/8/2007
[3/8/07] Please identify existing trees and intent to remove, protect or transplant.
Completed, refer to plan
Number: 20 Created: 3/8/2007
[3/8/07] Please separate the proposed trees into the following categories in the
plant legend: canopy shade trees, ornamental trees and evergreen trees.
Completed, refer to plan
Page 1