HomeMy WebLinkAboutNEW BEGINNINGS PHASE ONE OF REDWOOD VILLAGE COMMONS - Filed CS-COMMENT SHEETS - 2004-08-23CONCFF . UAL REVIEW STAFF COMMENTS MEETING DATE: ,lure 3, 1985 IT E M : New Beginnings Treatment Center APPLICANT: Bob Sutter, Sutter Architects, 420 South Howes, Fort Collins, CC 80521 LAND USE DATA: Drug and alcohol rehabilitation center and high density residential (16-26 DU/ac) on 10 acres COMMENTS: 1. This project is to be submitted as a planned unit development. 2. The nearby substation operated by the Western Area Power Administration has certain clearance requirements which must be maintained at all times. 3. Please consider fire sprinklering of both the treatment center and the multi -family residential buildings. 4. This site is immediately north of the proposed expressway running from I-25 to the northwest. Check with Bonnie Tripoli and Rick Ensdorff for exact alignment of this right-of-way and the associated frontage street system. Any development on this site must effectively buffer noise impacts from the expressway. 5. College and Lemay are the only access points for the expressway in this area. There will be no access at Redwood. 6. There is a potential delay in approving this project due to the state highway department being involved in reviewing this development. The Planning and Zoning Board cannot approve a preliminary plan without the approval of the state highway department. 7. Storm drainage is a problem in this area. The site must effectively handle on -site storm water. Also, substantial off -site drainage improvements may be required. 8. Any curb, gutter, and sidewalk that is damaged must be replaced by the developer. 9. Please look into the possibility of master planning the larger area surrounding this site. If this land is to be developed over a period of time, the Staff and the Planning and Zoning Board would want to see a coherent, well -planned development using a master plan. 21. Previous plans have shown fencing on the site; if this is still to be part of the site plan, it must be shown. 22. The submittal documents refer more than once to the landscape/visual amenity of the power line easement. Is there any specific plan for this area beyond what is shown on the landscape plan? 23. Concerning Point Chart E - Business Services: a. No points are allowed for this project being a part of a center. b. The intent of the mixed use criterion is probably not being met. You may want to provide additional justification for taking this credit. c. The energy conservation techniques being proposed are beyond City Code in some cases but staff is unwilling to give credit for a job "very well done." If full credit is desired please submit additional documentation. 24. There may be further comments from the traffic engineer. 25. The phasing of the landscape plan is questionable to staff and would probably not be acceptable to the Planning and Zoning Board. Staff suggests that the plan not be phased and a landscape bond arrangement be made with the City. At a very minimum, landscaping needs to be provided which accents and/or shields the building from the south and southwest. The landscaping provided in the first phase could benefit from additional foundation plantings along the south elevation and parts of the north elevation. Staff would also wish to see better integration of the landscaping with the master planned area to the north at this time rather than waiting for the residential phase. The 75 foot easement will have constraints which should be noted on the landscape plan and addressed at this time. 26. Please add to the building elevations the materials and proposed colors. 27. Concerning the density chart submitted for the residential area to the north: a. Points are allowed for (a) North College Plaza; (d) Aztlan Community Center; (g) day care center; and (j) contiguity. b. Bonus points for (m) are variable, but 15% active open area seems reasonable. C. For (t) structured parking, 9 points means 75% or more of the parking in a structure - that is underground, within the building, or in an elevated structure as an accessory use. d. For (u), points would be granted at the time of submittal of the plans after an agreement with the fire authority had been reached. The residential aspect of the plan required to score at least 35 bonus of over 10 dwelling units per acre. scores 65 base points and would be points in order to propose a density Revisions addressing the above comments are due in this office on September 4, 1986 at noon. PMTs, colored renderings and 10 copies of the site, landscape, building elevations and any other applicable documents are due on September 16, 1985 by noon. If you have any questions concerning the above comments please contact me. Sincerely, SkUa �Vbr Steve Ryder City Planner CC: Linda Hopkins, Acting Community Development Director Bonnie Tripoli, Development Coordinator 10. A traffic impact study is required for this project. The study will help to reveal any major improvements the developer would be responsible for completing. 11. Security will be an issue for surrounding residents. The security system will be reviewed by the police department upon formal submittal. 12. Before proceeding with submittal, further conceptual review is required for conceptual site plans. 13. A neighborhood meeting is required. All landowners within 500 feet and all residences within 1000 feet shall be notified (see attached map). A list of affected property owners must be submitted to this office at least three weeks before a scheduled meeting. The meeting must be held before formal submittal. CONCEFUAL REVIEW STAFF CCNIMENTS m MEETING DATE: ITEM : i;ew Beginnings Treatment Center - Master Plan and Phase One APPLICANT: Bob Sutter, Sutter Architects, 420 S. Howes -107, Fort Collins, CO 80521 LAND USE DATA: A 10-12 acre site with proposed uses being the New Beginnings Treatment Center (4 acres), multi -family residential (4 acres), and business/industrial (2 acres). COMMENTS: 1. Please maintain adequate easements between buildings and adequate clearance from power lines during construction (Light and Power). 2. Staff recommends fire sprinklering of all buildings. This is a requirement for residential structures over three stories (Poudre Fire Authority). 3. Adequate storm drainage is to be provided. Redwood is to be paved and a turnaround for emergency access is required. Please provide a sidewalk along Redwood. A Traffic Impact Study is required - please contact Rick Ensdorff for specifics (Engineering). 4. Please provide motorcycle and bicycle parking (Zoning). PLANNING COMMENTS 5. Please consider alternatives to perimeter fencing such as berming and landscaping of surroundings (power sub -station), streets, and the parking area. 6. If you are planning to submit both preliminary and final plans, full elevations with materials, colors, etc., and a final landscape plan are submittal requirements. 7. Please submit a density chart which justifies the proposed 24 DU/AC density for the multi -family phase. A copy of the base points is attached to these comments. 8. Staff and ultimately the Planning and Zoning Board will be concerned about the treatment of the 75 foot power line easement. Alternatives should be explored for making this area more than a minimally landscaped strip while also not interfering with the right-of-way. 9. The inclusion of the out -parcel along Conifer would add significantly to the coherence of the master plan. departmentO date: , I 77�71 ITEM: COMMENTS: -7. a 1 "0. is rim ITEM: h=c� wcx�c� CkQ� �J tk Y l 1i� un ck COMMENTS rj 4 a >< 0 1 a , l 7 7 j �f � (fah •^;-'C^.41��F -�� �rJ ��,J�� . Cc3ylC4,� < [ A vN Yre �n yc j t C� y s ._, l A IREGEWF-D AUG j 2 A5 PLANNONC- DEPAR WENT John St John Light & Power TO: M E M O R A N D U M FROM: Bonnie Tripoli, Development Coordinator RE: Subdivision Utility Plans DATE: Submitted for your review and comment are utility plans for: L_ Please respond >by: /ll i .ter F �EGEIvc-� AUG 16 jSa)- MEMORANDO;`M PLANT t+;; OWrAR7i�CNT Virgil Taylor Parks Superintendent TO: FROM: Bonnie Tripoli, Development Coordinator RE: Subdivision Utility Plans DATE: Submitted for your re iew and comment are utility plans for: Please respond by: �� E_E r t CITY OF FORT COLLINS COMMUNITY DEVELOPMENT DEPARTMENT, PLANNING DIVISION August 20, 1985 Jay Kee Jacobson Recovery Centers of America C/O Bob Sutter Sutter Architects/Planners 420 South Howes, #107 Fort Collins, Colorado 80521 RE: REDWOOD VILLAGE COMMONS MASTER PLAN (CASE # 59-85) AND NEW BEGINNINGS POD - PRELIMINARY AND FINAL PLAN (CASE #59-85A) Dear Bob: City staff has reviewed the above referenced projects and has the following comments: Redwood Village Commons Master Plan 1. A 36" water line is to be installed in the power line easement. This will require a 75 foot temporary construction easement and a 20 foot permanent utility easement. The estimated date of construction is early 1986. Improvements in the easement area should be delayed until after construction is completed. 2. An eight inch water line must be installed within the vehicle access route shown on the plan. 3. The 15 foot easement on all streets should read "utility easement" not REA easement. If the REA easement is necessary, the 15 foot easement will also need to be dedicated. 4. The master plan should have the following revisions made: a. The building and parking area should be removed. Just the land use, acreage and proposed square footage is needed along with building height. b. Phasing beyond the phase one treatment center should be provided on the plan. y OFFICE OF COMMUNITY 19 300 LaPorte A✓e. • P.O- Box 580 • Fort Collins. Colorado 80522 • (303)221-6750 DEVELOPMENT. PLANNING DIVISION c. The vehicle access shown is to be in the form of public streets. There may be some question as to the buildable area for the office/warehouse/showroom/retail area when a public street and the drainage easement are considered. 5. If you have any questions concerning drainage, please contact Tom Gathmann or Bonnie Tripoli. New Beginninys PUD - Preliminary and Final 6. The phase one building exceeds the 150 foot fire access requirement. If alternative access is not provided, full fire sprinkler protection is to be provided. 7. Please show water line sizes and fire hydrants. 8. The final plat will need to show dedication of an eight foot minimum width utility easement adjoining the west right -of -way line of Redwood Street. 9. The user of the concrete ditch to be removed must sign off on the plans if different from the current owner. 10. Redwood Street is to be completed adjacent to the project. 11. The sidewalk needs to be designed to City standards. 12. Pedestrian access ramps need to be provided interior to the site and at intersections. 13. Please provide drainage/grading plan attached to or enclosed with the drainage report. 14. The design of the off -site flow swale concept has some problems -- please contact Tom Gathmann for specifics. 15. Please indicate building height on the site plan. 16. Curbing is to be provided around landscaped areas. 17. Please further dimension the building envelope. 18. The 25 foot drainage easement adjoining the west right-of-way line of Redwood Street needs to be designated as a 25 foot drainage and utility easement. 19. The building use must be reviewed to conform with NFPA life safety code if classified as a health care facility. 20. On the landscape plan, the standard volleyball court dimension is 40 by 80 feet; minimum basketball court is 50 by 84 feet (outside perimeter).