RE: Alley Pavement Design
Fort Collins, Colorado
Project No. 85-4494-A
Dear Mr. Sutter:
July 23, 1985
at the Redwood Village Shopping Center,
Per your request, we have completed the pavement design for the
alley located at the Redwood Village Shopping Center in Fort Collins,
Colorado. The design is based on a Hveem value of less than five (5),
per Kruback Engineering Associates Report No. 85-4494-A dated May 31,
1985. Mr. Francis Todey of the City of Fort Collins Engineering De-
partment supplied the design Daily Traffic Number (DTN) of 65. Based
on these parameters, the following pavement thicknesses are recommend-
ed.
Alternative 1
Alternative 2
Asphalt 4" Asphalt 4"
Base Course 5" Base Course 7"
Subbase Course 13" Subbase Course 11"
If you have any questions, please feel free to contact us.
Sincerely,
Catherine A. Kuchta
Staff Engineer
CAK/jh
Viewed by: �aQ.��1•"�.�,
Duane H. Smith, 4E S►
903 Cleveland Avenue
Loveland, CO 80537
(303) 667-8010
1305 Duff Drive
Ft. Collins, CO 80524
(303) 493-8010
August 1, 1985
Ms. Bonnie Tripoli
Development Coordinator
("anunity Development Department
Pfanni ny; Division
City of Port Collins
P,O, &)t 580
NO Collins, Colorado 80532
Subject: Redwood Village Center - Time delay of.
Door h'onnic:
This Letter will verify our agreement to extend the final review
of Redwood Vil!ago Center 30 days. We understand that this time
in required to allow for the additional review of sewer profiles
and drn,✓ings and to runnlva drainage conflicts with the North
College Plaza I.H.D.I
I ❑m in receipt of your 26 .July I.etLer which explains the
idditirnal information yen will require. As per our discussion,
I r-cqurst that we be .allowed .a bit longer than 6 August to complete
this addi_ional information. I would propose. h Au,,ust.
The City is stiLl reviowiun potential solutions to the drainage
remlli,ts and so it will t::ke us a hit longer ha complete grading
and drama},/dintOnLion drawings. 1 ❑m also enclosing; a copy
ail Kruhuck kngineering's de;inn for the alley pavement. 1 ask
I hat ya:a review thin in linht of the real. traffic JUL will take
place in this alley. This dehiju appears a bit strong,.
I rapprrciatr your help in these matters and thank you for your
Ittonliun.
Cordially,
t
Robert A. Sutter, A.I.A.
President
WAS/ kI
cc: Jav Kee Jacobson
Mary Hnusch
"TA
I1.0. 1 „x 11, -�
Gra 1 y c oloi:,d P ': ,.,2
August 27, l�J S;S
) ,s,� y ��
larimor Co., Off-
Systems
New Beginnings P.U.D.
NW of Redwood St.
and
Conifer St. (Ft.
Collins)
Planning Dcpirtu:,st
City or Ft. Collins
DOh File 45100
P.O. Boa 5&0
Ft, Collins, CO 80522
Dear Sir or Madam:
We have reviewed the New Beginnings R.U.D. and have the following
Comments:
This V.U.D.
is Located just
to the north
of where the Ft. Coll -ins
Expressway in to
he constructed.
Although the
right o` way for this
highway will not
directly affect
this property,
highway traffic noise
woui d affect the
soothcrn portion
of the site,
including the outdoor
play area and proposed
building.
tin Ord- to minimize the potential future impact of
this traffic
nois-,
we recucw, nd
that noise abatement measures be provided.
These
could
includ^ noi.p,
insulation of the building and an earth
berm and/or
nnign
wall- along the
south side of the property. To he
effective
for
rcise ab.aVvm0nt
this wall shcald he eight -feat high
with no openings
to allow
noise penetration.
Thank you for the opportunity to review this Y.U.D. Please contact_
Wally Jacobson at this office if you have any questions.
very truly yours,
ALBPRT CHOTVACS
DISTRICT IiNG.T,NEEP
r --- -'_� John K. r .
Cric-
District Planning/Environmental Mv!iger
JKC:WJ:mhc
cc:: A. Chotvacs
Tile: Crier -Jacobson
September 4, 1985
Mr. Bob Sutter
Sutter Architects/Planners
420 S. Howes, Suite 107
Ft. Collins, CO 80524 85-4635-G
RE: . . New Beginnings, pipe protection
Dear Bob:
At your request we have conducted resistivity testing of the New Be-
ginnings Project site for use in determining the protection requirements
for buried cast iron or ductile iron pipe. The results of the tests are
as follows:
Resistivity,
Location Probe Spacing, Ft. ohm - cm
TH-2 4 1516
12 2573
Based on the resistivity test results we recommend the buried pipe be
bedded and surrounded with six inches (6") of sand backfill. No plastic
sleeve is required around the pipe but is recommended for all applications
by some pipe manufacturers to promote longer life of the pipe.
If you have any questions, please do not hesitate to call.
JFD/em
903 Cleveland Avenue
Loveland, CO 80537
(303) 667-8010
Sincerely,
COS ENGINEERING CORPORATION
ohn F. Donnelly, P.E.
Director of Technical Services
1305 Duff Drive
Ft Collins, CO 80524
(303) 493-8010
rh�o1 l✓l f e ,r I n y (!/r� f rot/
J.,.;OB FAMILY SERi ICL= i
Front Range Regional Services
Jacob Center North Jacob Center East Jacob Center South
633 Remington 1116 9th Street 1338 Oswego
Fort Collins, CO 80524 Greeley, CO 80631 Colorado Springs, CO 80904
(303) 484-8427 (303) 352-2852 (719) 635-3362
Fax: 482-8713
August 2, 1993
Mr. Glen Schlueter
Stormwater Utility
235 Mathews
Fort Collins, CO 80524
Dear Mr. Schlueter:
STORMWATER REVIEW COPY
Final Amroved ReoW
I am writing you in response to a written comment from Kirsten Whetstone
regarding our application for development approval on The Jacob Center for 50 Youth
at 1225 Redwood Road (formerly New Beginnings of Fort Collins).
Our plans include no further development of the site, no change in impervious
surface area and no stormwater flow alteration.
If you have any questions regarding this aspect of our application, please feel free
to contact me at the number listed above. Thank you for your time in this matter.
Sincerely,
N(-Xt-
John J. Carlson
Executive Director
JJC/lar
Dina Appfovu�' RepOrt