HomeMy WebLinkAboutMINI MART PUD - Filed CS-COMMENT SHEETS - 2004-08-17CONCEP', UAL REVIEW
STAFF COMMENTS
MEETING DATE: �)anua,v 30. 1984
IT E M : Mini Mart
APPLICANT: John Dengler, Dengler Associates, 141 South College, #E10,
Fort Collins, Colorado, 80524
LAND USE DATA:
4800 square feet mini. —mart, gas pumps and retail uses on 1 acre
COMMENTS:
1.
Stacking spaces for each pump will be required. The amount
of stack —up
will be a function of the amount of traffic. Motorcycle, handicapped
and
bicycle parking will be required.
2.
The site plan should indicate all existing and proposed curb cuts
on adjacent
properties.
3.
Joint vehicular access between properties is encouraged.
4•
The curb cuts as shown are too close to the intersection. A
minimum of
200 feet is required. Some temporary solutions may be possible.
5.
It will be very difficult to provide for the access needs of
a mini —mart
at this location.
6.
A minimum of 50 feet of ROW along Willox Drive and 60 feet
on College
Avenue will be required. The streets should be shown to their
full future
width.
7.
A traffic impact analysis will be required.
8.
Additional landscape buffering along property lines will be required.
9.
A minimum of 10 feet clearance from overhead power lines should be
maintained.
10.
The stacking area at entrance will be dependent upon traffic
generation.
Fiftv foot setback may be insufficient.
11. There are drainage problems at the intersection that need to be resolved.
12. State approval will be required of curb cuts. The access plan as shown
will not meet these requirements.
13. There may be additional fire requirements for underground tanks. Check
Uniform Fire Codes for information.
14. Sewer extensions will be required from an existing line in Willow Lane.
Ms. Julie Thomas
From: Cathy Chianese
March 21, 1984
Page Two
13. Clearly designate how use of the gas pumps is to occur. Indicate where
adequate stacking space for gas pumps is provided. What is purpose of
"additional access lane"?
14. Landscaping in front of the building should be provided.
15. Is fencing provided along west property line?
16. Indicate where fuel unloading will occur.
17. Indicate nearest existing fire hydrants.
Revised site and landscape plans addressing the above comments are to be
submitted by Wednesday, April 4, 1984. By Monday, April 16, 1984, 8z"xll"
reductions and colored renderings of the plans are to be submitted. Ten (10)
24"x36" site and landscape plans are to be submitted by Monday, April 16,
1984.
If you have any questions regarding the above comments, please do not hesitate
to contact me.
Sincerely,
Cathy Chianese
Senior City Planner
CC:ro
cc: Bonnie Tripoli, Development Coordinator
Mauri Rupel„ Development Center Director
4 MAY 1984
DATE DEPARTMEN F
ITEM:
MINI -MART PUD FINAL #18-84A
4 MAY 1984
DATE DEPARTMEN'
----
ITEM
MINI -MART PUD FINAL
#18-84A
c
dv /W.7 C41V CL�
TO: Bob Smith, Assistant City Engineer - Drainage
FROM: Bonnie Tripoli, Development Coordinator
RE: Subdiv" Utiu�y�k�r��
DATE:
Submitted fer,y1our revie rid coma nt a"/ i plans for
Please respond by
- t
{ gar
i
/•�,tiik,, .,:l,C.c-•u��
cl
6''qG,l �i {�!.c
i f
0
CITY OF= FC�r-�T COLLINS
OFFICE OF PLANNING AND DEVELOPMENT
May 25, 1984
Julie Thomas
John Dengler & Associates
760 Whalers Way, Bldg E, Suite 200
Fort Collins, CC 80525
Dear Julie:
Staff has reviewed the Mini -Mart PUD, Final, and has the following comments:
1. Developer required to participate in an improvement district for Willox
Lane or to improve the street when deemed necessary by the City.
2. Dimension walk in front of store.
3. Sidewalk to be detached one foot from property line where detached.
4. Loading zone to measure 500 square feet.
5. The PMT reduction and colored rendering submitted for the Preliminary
PUD can be used for final presentations.
6. Ten copies of the landscape and site plans are to be submitted on June
18, 1984.
If you have any questions regarding the above comments please feel free to
call.
Sincerely,
Cathy Chianese
Senior City Planner
cc: Bonnie Tripoli, Development Coordinator
CC/ga
a
[JJD i_jFVH O�3MI N r
PROJECT
COMMENT SHEET
Current Planning
DATE: March 25, 1999 DEPT: Water & Wastewater
PROJECT: #Mini -Mart
All comments must be received by Tim Blandford no later than:
April 15, 1999
➢ Provide manhole adjustment detail with next submittal.
➢ See utility plans for other comments.
Date: Signature:
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
PLAT _RED _DRAIN DRAINAGE REPORT -OTHER
II X TI LITY X REDLINEUTILITY -LANDSCAPE
City of Fort Collins
DATE: March 31, 1999 DEPT: ENGINEERING
PROJECT: Mini -Mart Street Improvements
All comments (must be received by Tim Blandford no later than the staff
review meeting;:
Wednesday, April 21, 1999
MAJOR COMMENTS FROM THE UTILITY PLANS
X Modify the General Notes.
X Please provide a redirect taper from the proposed improvements to the existing street.
X You will need an offsite construction easement for the portion of the curb return outside of
the ROW.
X You will need to acquire a State Highway Access Permit for the work within the State
ROW.
• X Please modify the curb return radii as indicated.
X Show the lane striping east and west of College Avenue along West Willox Lane.
X� It is the City's policy to underground overhead utilities. Please check with the appropriate
Utilities about doing this.
0I think it would be a good idea to meet with the Traffic department regarding their
comments and the comments from the Engineering department.
WX Show the cross sections provided by R & R Engineering and include the proposed
1 elevations along the north flowline. Do they match?
X The slope of cross pans need to be a minimum of %60% per standards.
X Benchmarks are now referenced from the new ve al control. The City no longer uses
the Black Bolt Survey. i
DV
(ol,j &
Date: 5. tP `i9 Signature
Please send copies _Plat _Site
of marked revisions ✓Utility _Landscape
❑ NO COMMENTS — SUBMIT MYLARS
City of Fort Collins
REVISION
COMMENT SHEET
DATE: March 31, 1999 TO: Traffic Operation
PROJECT: S2H-Fox7-Meadows AparAn-rer}ts==P-UD -
Prehininarq-- (+DGS)
All comments must be received by-Te4:ShepaFt-no later than the staff
review meeting:
Wednesday, April 21, 1999
No Comment
FIProblems or Concerns (see below or attached)
I
/
J
Date: `/,�� �, _Signature:
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat 0 Site _ Drainage Report _ Other
Utility _ Redline Utility _ Landscape
00000
0001
PROJECT
City of Fort Collins COMMENT SHEET
Current Planning
DATE: April 8, 1999 DEPT: Stormwater
PROJECT: Mini -Mart Street Improvements
Please provide a drainage report (or letter) that describes the stormwater facilities at
the site. The :letter should refer to the approved Willox Crossing and Mini -Mart
reports and describe how they tie-in with this project. The letter should be signed and
stamped by a professional engineer.
RESPONSE:
2. Please explain how the inlet was sized (i.e., how much flow is coming to the inlet)?
If applicable, please refer to previous reports. Please submit information on the
contributing area to the inlet with calculations that show the flow rates to the inlet.
RESPONSE:
Please provide a profile of the storm sewer that includes the 100-year HGL. The
drainage report should include any calculations.
RESPONSE:
MiniMart-l.doc
Date: l Signature:
Cc i;m.31 �d
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
PLAT _SITE. DRAINAGE REPORT _OTHER
UTILITY _REDLINE UTILITY _LANDSCAPE
REVISION
COMMENT SHEET
DATE: December 17, 1999 DEPT: Stormwater
PROJECT: Minimart Street Improvements
All comments must be received by Dave stringer no later than:
Friday December 17, 1999
Please revise all the storm sewer lines that are shown per the Willox Crossing improvements
to reflect their latest plans dated 12/13/1999
2. Please tie in the existing 4-foot curb inlet in Willox court into the new storm sewer system
proposed by the Willox Crossing project. Please check for potential conflicts with the
existing sanitary sewer line in Willox Lane. Is there a possibility of increasing cover on the
line proposed by Willox crossing on the north side of Willox ? This existing inlet may need
to be improved or replaced in order to tie it into the system in willox lane and disconnected
from where it currently drains.
Make the existing sanitary sewer line in Willox Lane more visible on the plan view. Check
for all conflicts between any proposed storm drain lines and all existing utilities.
The plan view calls for a proposed 5-foot inlet on Willox while the detail is for a 4 foot curb
inlet. Please reconcile.
Date:� Signature:
cc.17a�$r'
CIIF.CK nF.RF. IF YOU WISH TO RECEIVE COPIES OF REVISIONS -;
_ Plat Site Drainage Report _Other cc , KOf,
_Utility _RedlineUtility —Landscape
City of Fort Collins
'DATE 3-5-84 DEPARTMEN
J�
ITE Ni'IA2 M)*-MPIIZ-T
COM, NICENTS
ccw�x
Aid v. C.J.cnp-c-
(,,tvJe:r, C44&1-44
PROJECT '—
City of Fort C.='"=' COMMENT SHEET
ENGINEERING
DATE: May 8,2001 DEPT: Engineering
PROJECT: Mini -Mart — Willox Street Improvement Plans
ENGINEER: Dave Stringer
Dave Stringer must receive all comments no later than:
MAY 29 2001
1. Need to show detail of how existing area inlet is to be plugged
2. Show existing type R inlet on College
3. Widen sidewalk at radius to fit
4. Provide profile of storm sewer extension- minimum size of City maintained storm sewer
pipe is 15 inch
5. Address all Comments, for Stormwater comments, work directly with them, then submit
Mylar plans for City approval
Date: Signature:
PLEASE. SEND COPIES OF MARKED REVISIONS: n PLAT SITE
rl UTILITY
n LANDSCAPE
t REVISION
�' •'tCOMAW-AT SHEET
DATE: May 8, 2001 DEPT: StorniNvaler
PROJECT: Minnnart Street Improvements
All comments must be received by Dave stringer no later than:
Wednesday May 2, 2001
1. Please provide it drainage report (or letter) that describes the storniNvater facilities at the site.
The letter should refer to the approved Willox Crossing and Mini -Mart reports and describe
how they tic -in with this project. The letter should he signed and stamped by a professional
eneurccr.
RESPONSE:
2. Please explain how the inlet was sized (i.e., how much flow is coming to the inlet)? If
applicable, please refer to previous reports. Please submit information on the contributing
area to the inlet with calculations that show the flow rates to the inlet.
RESPONSE:
3. Plcasc provide a profile of the stornn sewer on the plan that includes the 100-year NGL. The
drainage report should include any calculations.
RESPONSL:
4. please show the existing gas line in Willox Lane on the plan.
RESPONSE:
5. Plcase distinguish more clearly what is existing and what is being built with this project.
RESPONSE.:
G. Please provide a manhole or junction box with access at the pipe transition from 12 to 24-
inch.
RESPONSE:
7. If anything lareer than a 12-inch storm sewer will not fit with the required cover, than please
provide an elliptical 11 x 18-inch sewer pipe for stretch of 12-inch RCP.
RESPONSE:
Pl(ase refer to the redlined report and plans for additional review comments.
Date: fz Y D,/ Simlaturc:
(lnA1 1117tt: tr)oJ vvI SHIO Nr(lavP( OPIES On HEN ISI01S
_ flat _Site _ Drainage Report Other
X I tilih �' Redline l'tilit) _ Landscape
Citv of }ort Collins
-DATZ", DEPAPMNIIE\�,,j j-
............
m A I
IT ENIA Lj� -
PI-T Z-T
CLOM" MENTS
DATE 3- 5-8D PATj'V,] j ,`A
COMMENTS
TO: Bob Smith, Assistant City Engineer - Drainage
FROM: Bonnie Tripoli, Development Coordinator
RE: Subdivision Utility Plans
DATE: 3— 6 -- �—"z
Submitted for your review and comment are utility plans for
Please respond by 3 — 3 — 7"
STATE OF COLORADO
DIVISION OF HIGHWAYS
EN OF
P.O. Box 850
Greeley, Colorado 80632-0850
(303) 353-1232
March 16, 1984
RECEIVED
MAR 19 1984
Planning Department Pts,>-"10+ �
City of Fort Collins DFPAEMIT
P. 0. Box 580
Fort Collins, Colorado 80522
Gentlemen:
We have reviewed the Mini -Mart P.U.D. and have the following comments.
Larimer County
SH 287
Mini -Mart PUD
NW Corner of
Willox Lane & 287
(Ft. Collins)
DOH FILE 45100
1. The 60-foot right of way west of the State Highway 287 centerline is con-
sistent with the City's recommended total right-of-way width. Our records
indicate that the existing width west of the highway centerline is 40
feet. Therefore, the additional 20 feet should be dedicated by the
developer. If this is done, the "existing sign" would need to be moved
onto private property.
2. The right -turn -only access on S.H. 287 is acceptable in this particular
case for thiree reasons. First, this property has had access to the highway
during its use as a restaurant. Second, this P.U.D. is a continuation
of a commercial -type use. Third, we do not foresee that this P.U.D. will
result in enough of a significant increase in traffic to restrict direct
access to the highway.
Construction of this limited access will require an "Access Permit."
Application for this permit is made to the City of Fort Collins. Due
to the projected traffic at this access, a right -turn deceleration lane
is warrante-d and should be built in conjunction with this access. However,
due to the limited right of way and existing development north of this
property, it may not be possible to construct this lane. If this is the
case, a "Variance" to the State Highway Access Code will need to be
included with the Access Permit.
3. There is highway widening shown along this property which should be designed
to be consistent with the City's proposed typical section for North College
Avenue. Since there are only two existing southbound travel lanes, addi-
tional width should be provided to accommodate the future design. We
encourage coordination with this office prior to the Access Permit review
process to ensure compatibility with our design standards.
4. Development: of this property should take into account the impact on surface
runoff. We, ask that on -site detention be provided to ensure that the
historical runoff rate will not be exceeded. This would prevent any adverse
impact on the highway drainage system.
March i6, 1984
Planning Departrnmant
City of Fort Collins
P. 0. Box 580
Fort Collins, Colorado C0522
Gentlemen:
We have reviewed the Hini-Nowt P.U.D. and have the following coramsents.
Larimer County
SH 287
Mini -Mart PUD
NW Corner of
Willox Lane 3 287
(Ft. Collins)
DOH FILE 451DO
1. The 60-foot right of way west of the State Highway 287 centerline is con-
sistent with the City's recommended total right-of-way width. Our records
indicate that the existing width west of the highway centerline is 40
feet. Therefore, the additional 20 feet should be dedicated by the
developer. If this is done, the "existing sign" would need to be moved
onto private property.
2. The right -turn -only access on S.H. 287 is acceptable in this particular
case for three reasons. First, this property has had access to the highway
during its use as a restaurant. Second, this P.U.D. is a continuation
of a commercial -type use. Third, we do not foresee that this P.U.D. will
result in enough of a significant increase in traffic to restrict direct
access to the highway.
Construction of this limited access will require an °Access Permit."
Application -for this permit is made to the City of Fort Collins. Due
to the projected traffic at this access, a right -turn deceleration lane
is warranted and should be built in conjunction with this access. However,
due to the limited right of way and existing development north of this
property, it may not be possible to construct this lane. If this is the
case, a "Variance" to the State Highway Access Code will need to be
included with the Access Permit.
3. There is highway widening shown along this property which should be designed
to be consistent with the City's proposed typical section for North College
Avenue. Since there are only two existing southbound travel lanes, addi-
tional width should be provided to accomraodate the future design. We
encourage coordination with this office prior to the Access Permit review
process to ensure compatibility with our design standards.
4. Development of this property should take into account the impact on surface
runoff. We ask that on -site detention be provided to ensure that the
historical runoff rate will not be exceeded. This would prevent any adverse
Impact on the highway drainage system.
FT. COLLINS PLANNING DEPT.
March 16, 19£A
Page Two
Thank you for the opportunity to review this P.U.D.
Very truly yours,
ALBERT CHOTVACS
DISTRICT ENGINEER
Mini -Mart PUD
DOH FILE 45100
GU
e1s c &.
District Preconstruction Ennineer
WFR:da(66Z)
cc: A. Chotvacs
D. Yost
Area Foreman
File: Crier -Jacobson
— w/enct.
CITY OF- FORT COLLINS
OFFICE OF PLANNING AND DEVELOPMENT
March 21, 1984
Ms. Julie Thomas
DENGLER & ASSOCIATES
Building E, Suite 200
760 Whalers Way
Fort Collins, Colorado 80525
Dear Julie:
Staff has reviewed the Mini -Mart PUD, preliminary and has the following com-
ments:
1. Applicant needs to apply for "access permit" from the City on the right-
in/out curb cut proposed on North College Avenue.
2. Sidewalk on College Avenue to be 7 feet; 7 feet on Willox where it is
adjacent to street.
3. The curb cut on College needs to be redesigned to City standards and
dimensioned.
4. Tire stops are to be installed on parking stalls adjacent to building.
5. Dimension the walk adjacent to building.
6. Show all handicapped ramps. Handicapped parking space needs to be only 12
feet.
7. Dimension travel lanes on College Avenue.
8. Drainage report requires signature and seal.
9. Indicate 500 foot loading space.
10. Designate motorcycle parking.
11. Indicate typical width of parking spaces.
12. All signs ust comply with City sign code.
U F'f;I f A [,I MJN'NG ''00 L�,Por ❑ Aae. . P U Hox tiEEC Fort. Coln Colorado H"522 . (3031 221-H750