HomeMy WebLinkAboutMARKET AT HORSETOOTH COMMONS PUD - Filed GC-GENERAL CORRESPONDENCE - 2004-08-16REDPEAK ENGINEERING 771 S Wnchwo e— d (303)-980-0355 P.O. Box 566 • Windsor, CO 80550 • (303) 686-9717 April 7, 1987 Mr. Mike Hertzig, PE Development- Coordinator City of Fort Collins 300 LaPorte Avenue Furl- Collins, Co 80521 RE: Revised Preliminary Site, Utility & Drainage Plan for Williamsburg PUD Dear Mike: I have reviewed the proposed revised preliminary site, utility, and drainage plan for Williamsburg PUD. The revised preliminary plan is substantially the same in terms of drainage impact as the previously approved preliminary PUD and drainage study. We, therefore, do not believe it is necessary to modify the previously approved preliminary drainage plan at this time. If you have any questions, please give me a call. a�ncerely, John Barnet -t, ASLA Vice -President cc: 7.VFK Debbie Tamlin JC/jk CITY OF FORT COLLINS DEVELOPMENT SERVICES — ENGINEERING June 19th, 1987 Mike Beasecker c/o Circle K Corporation 1127 S. Tejon Street Denver, CO 80223 Dear Mike; The City of Fort Collins Engineering Services will release the Footing and Foundation Permit for the proposed convenient store on the northwest corner of Shields Street and Horsetooth Road without the completion of all the utilities, provided the Developer has met the three conditions as specified in the Development Agreement for The Market at Horsetooth Commons P.U.D., and is restated below: E. Footing and 'Foundation permit. Prior to the issuance of the footing and foundation permit for any buildings within this Development, the Developer agrees to the following: (i) No combustible material will be allowed on the site until the water system is installed by the Developer and approved by the City. (ii)To provide and maintain an adequate all-weather roadway access to any building under construction, to handle any emergency vehicles or equipment. Such access shall be at a minimum, 20 feet wide roadway of 4" base course material compacted according to City Standards, with a 40' radius turnaround at each building and dead end. (iii)The issuance of said footing and foundation permit is solely at the Developer's own risk and the Developer shall hold the City harmless in the event of any damages result- ing from the issuance of said permit prior to the comple- tion of the requirements in accordance with the Code of the 300 LaPcrte Ave. • PO. Box 580 • Fort Collins, Colorado 80522 • 003) 221 6605 Page 2 Engineering services agrees to release the building permit for said build- ing provided all required utilities have been completed by the Developer and accepted by Engineering Services. The required utilities are all util- ities as specified in Chapter 99-6. B. in the City Code serving such build- ing which is the subject of the Building Permit, and are shown on the approved utilities plans. If you have any questions concerning this matter please contact me at the Planning Department (303) 221-6750. S ncer ly; 1/ I mNewell / Civil Engineer cc: Dave Stringer, Chief Inspector Ted Shepard, Project Planner.