HomeMy WebLinkAboutHARMONY CENTRE - Filed CS-COMMENT SHEETS - 2004-08-10PROJECT COMMENT SHEET City of Fort Collins Current Planning DATE: July 17, 1997 DEPT: Engineering. PROJECT: #6-96D Harmony Centre P.U.D. - Pad 1 Final (LDGS) PLANNER: Mike Ludwig All comments must be received no later than the staff review meeting: Wednesday, August 13, 1997 GENERAL COMMENTS AND CONCERNS: SEE PLAN SET FOR COMMENTS AND CONCERNS. Date: ' signature: ti CHECK HERE IF YOU WISH TO RECEIVE COPES OF REVISIONS ` x Plat Site _ Damage liepoit _ Ok _ Utility Reline Utility " Lmds* City of Fort Collins 11. The Colorado Department of Transportation offers the following comments: a. The State is reviewing the access permit for auxiliary lane improvements to existing Pavillion Lane. This will be finalized with the City of Fort Collins. b. A separate access permit must be obtained for access north of Pad #1, with auxiliary lane on College Avenue. 12. The Current Planning Department offers the following comments: a. The legal description on Sheet 1 of 4 should reference Pad Site 1 b. Please indicate the proposed use/tenant in the title block at the top of each page and in the title block at right hand side of each page. C. Please revise the index of drawings at to state that Sheet 2 is the overall site plan for the entire Harmony Centre; that Sheet 3 is Pad 1 Site Plan and Elevations; and that Sheet 4 is the Pad 1 Landscape Plan. d. The zoning districts indicated on the Vicinity map on Sheet 1 of 4 references zoning districts that no longer exist. Please revise the vicinity map to reference CityPlan zoning districts. e. General Note 4 on Sheet 1 references that all rooftop and ground mounted mechanical equipment will be fully screened. Please show how this will be accomplished on the building elevations and landscape plan. f. General Note 14 on Sheet 1 indicates that pedestrian plazas shall be provided with amenities such as benches, planters, decorative lighting, and other features. None of these features are shown on the perimeter of the building on Pad 1. Please add. g. Please delete General Notes 15, 16 and 17 on Sheet 1 as they are not relative to Pad 1. h. Please delete the Building I (Home Depot) consultant information from sheet 1. i. Please revise the title of the future land use plan for adjacent properties to state "Potential Future Land Use........" Commercial areas north of the Harmony Centre should be labeled as "potential commercial". The retail site (Circuit City) should be labeled as .'approved retail". The automotive (Schrader's) should be labeled as "existing automotive". j. Please revise the Site Data according to the attached format. k. Has the public street r-o-w square footage been revised to reflect the additional 2 feet added for turn -lanes? I. The building floor area listed for Pad 1 is different on each of the plan sheets(15,550 ... 15,000... 15,552... 15,000). Which is correct? Please revise all sheets accordingly. M. The maximum building height is listed as 40 feet on Sheet 1. However, the maximum building height is 30 feet according to the building elevations. Please revise Sheet 1. n. Pad 1 extends onto the Schrader property which is not a part of the Harmony Centre PUD. Please clarify on Sheets 2, 3 and 4. o. Has Sheet 2 been revised to reflect the additional 2 feet of r-o-w for the turn -lanes? P. Please dimension the widths of all sidewalks, setbacks, typical parking stalls, etc. on Sheet 3. q. The widths of sidewalks around the building on Sheets 3 and 4 are not the same. Please clarify. These walks should be at least 6 to 7 feet wide with a minimum 5.5 foot planting strip adjacent to the building for trees and shrubs. r. The setback of the south west corner of the building from the south property line is only 5 feet. It was 10 feet on the Preliminary PUD. S. The Legend on Sheet 3 does not include all lighting symbols. How tall are the light poles? The trash dumpster symbol should be labeled as "trash dumpster/enclosure." t. It appears that the light pole on the east side of the drive thru lanes impedes pedestrian traffic by being in the middle of the sidewalk. U. Is the sidewalk connection from the northwest corner of the building to College Avenue in compliance with City/ADA accessibility requirements? Circuit City had great difficulty in achieving this. V. Please indicate the color of the awnings on the building elevations and change the title in the color schedule to "fabric awnings". W. The south and east building elevations are pretty blank and need some additional architectural detail. X. Is the monument sign a Harmony Centre monument sign or a Pad 1 monument sign? Y. Is there any wall signage proposed on the building elevations? Is it lighted? ... neon? Z. The handicap ramp at the southwest comer of the plan (along College Avenue) is not shown on the utility plans. Please coordinate. aa. Please label South College Avenue on Sheets 3 and 4. bb. Please show Pad 1 landscaping darker and show landscaping from Harmony Centre First Filing lighter on Sheet 4. Is the Landscape Plan the same as the approved First Filing Landscape Plan? cc. In general, the Plans submitted appear to be a CAD enlargement of the 100 scale site plan. Please make sure that light poles, landscaping, sidewalks, etc. are correctly located at this scale. Also, please coordinate the information provided on the Site, Landscape and Utility Plans. dd. Please provide a trash enclosure elevation on Sheet 3. 13. Redlined plans from the Engineering Department are attached. 14. Comments from the Stormwater Utility are attached. This completes the review comments at this time. Additional comments may be forthcoming as the various departments and reviewing agencies continue to review this request. Please provide a written response to each of the above stated comments with the submittal of plan revisions. A Planning and Zoning Board date will be assigned once all comments have been addressed and revisions have been reviewed. Please contact me at 221-6206 if you have any questions or concerns related to these comments. Sincerely, Michael Ludwig, AICP City Planner xc: Tim Blandford Stormwater Utility file/Project Planner Commi _ity Planning and Environmental ervices Current Planning City of Fort Collins August 20, 1997 Terry Rucker SEM Architects 7935 E. Prentice Avenue, #102 Englewood, CO 80111 Dear Terry: Staff has reviewed your plans for the Harmony Centre Pad Site 2 Final PUD that were submitted on July 16, 1997 and would like to offer the following comments: 1. The Water Conservation Specialist stated that the landscape plan must contain a note calling for the review and approval by the City of Fort Collins of any landscape irrigation system, prior to the issuance of a Building Permit. 2. The Advance Planning Department offers the following comments: a. There was no indication on the plans showing the location of any mechanical equipment. Please show how this equipment will be fully incorporated into the building's architecture. b. Bollards at the edge of the sidewalk on the north east corner of Pad 2 would help define the pedestrian and vehicular areas. 3. The Zoning Department offers the following comments: a. One additional handicap stall is needed as a total of 3 handicapped parking spaces are required. b. Please dimension the distances of the building from the lot lines. C. Please dimension the overall building height on the building elevations. d. Please indicate the proposed/permitted land use(s) for the building within the building envelope on Sheets 2 and 3. 4. The Building Inspection Department offers the following comments: a. Please clearly show the property lines and proximity of property lines to the proposed building on the site plans submitted with the application for building permit. b. The site shall be accessible to persons with disabilities in accordance with Uniform Building Code Section 3103 and UBC Appendix Section -t;l .XUIIII G)II ,' Aacnuc • P.O. Boy �RL' • Port Collins, I:AA (970) 221-(,3:5 • I DLJ (97U) 3=4-6n02 3106. A designated and marked "accessible route of travel' among all the buildings on the site and building exits and entrances and the public way (public sidewalk) is shown. Accessible routes shall comply with ANSI A117.1-1992 with running slopes no greater than 1:20 and cross slopes no steeper than 1:50. Where routes cross lanes for vehicle traffic, they shall be designated and marked as a cross walk. Provide parking and signs per Appendix Section 3107. Parking and access aisles shall comply with ANSI Al17.1-1992 with slopes no greater than 1:50 in any direction. C. Buildings shall be designed to comply with the Fort Collins Nonresidential Energy Code (ASHRAE 90.1 with local amendments) or residential energy code (MEC 1995 with local amendments) whichever is applicable. Section 504 of the 1991 edition of the Uniform Building Code as adopted by the City of Fort Collins requires that exterior walls of building 1 located closer within distances, based on use and construction type, to a property line be of fire -resistive construction. Openings are restricted or prohibited in such exterior walls. A parapet extending 30-inches above the roof surface may be required by UBC Section 1710. Projections, such as cornices, eave overhangs or exterior balconies shall not extend over the property line and must comply with UBC Sections 1710 and 504. 5. The Transportation Planning Department offers the following comments: a. Please move the bike rack from the southeast corner of the building to the northeast corner of the building (closer to the building entrance). b. Please show the sidewalk connection and enhanced crossings requested on the south side of Pad 1 from College Avenue to the east side of the drive thru lanes. The Fort Collins -Loveland Water District and the South Fort Collins Sanitation District have reviewed the above mentioned submittal and have no objections provided all District requirements are satisfied. 7. The Natural Resources Department stated that the trash enclosure must be large enough to accommodate trash and recycling dumpsters. 8. U S WEST offers the following comments: a. Review of these plans should not be construed as a commitment that telephone facilities sufficient to serve this project are presently available. U S WEST will provide telephone service in accordance with the rates and tariffs on file with the Colorado Public Utilities Commission. b. The owner is responsible for provision of all conduit, ditch crossings, and street crossings for telephone facilities within the project. The owner also provides terminal room space (usually 8' x 4') and power for the telephone terminal, generally in a utility room. Contact the U S West engineer for conduit specifications for the telephone entrance cable. C. Any relocation of existing telephone facilities required by these plans will be paid for by the developer. 9. The Poudre Fire Authority offers the following comments: a. Fire hydrants are required with a maximum spacing of 600 feet along and "approved roadway'. Each hydrant must be capable of delivering one -thousand (1,000) gallons of water per minute at a residual pressure of twenty (20) pounds. No building can be greater than 300 feet from a fire hydrant as measured from the building to the hydrant along the approved roadway. b. A table found in the 1991 Uniform Building Code Appendix III-B relates construction and area to required fire flows. C. Proposed building (Pad 2) exceeds 5000 square feet and must be fire contained or equipped with an automated fire suppression system. (Local Amendment to Table 38B UBC). d. If building is equipped with a fire sprinkler or fire alarm system, a "knox box is required. 10. The Colorado Department of Transportation offers the following comments: a. CDOT must review detailed plans for auxiliary lanes and accesses to SH68, and issue access permits in/when changes in deeded access control line are approved through CDOT's ROW Section, not before. b. CDOT has not made detailed review of auxiliary lane and access designs or reviewed issuance of access permits. The plan sets do not offer adequate detail for that level of review. 11. The Current Planning Department offers the following comments: a. The legal description on Sheet 1 of 4 should reference Pad Site 2. b. Please indicate the proposed use/tenant in the title block at the top of each page and in the title block at right hand side of each page. C. Please revise the index of drawings at to state that Sheet 2 is the cverall site plan for the entire Harmony Centre; that Sheet 3 is Pad 2 Site Plan and Elevations; and that Sheet 4 is the Pad 2 Landscape Plan. d. The zoning districts indicated on the Vicinity map on Sheet 1 of 4 references zoning districts that no longer exist. Please revise the vicinity map to reference CityPlan zoning districts. e. General Note 4 on Sheet 1 references that all rooftop and ground mounted mechanical equipment will be fully screened. Please show how this will be accomplished on the building elevations and landscape plan. f. General Note 14 on Sheet 1 indicates that pedestrian plazas shall be provided with amenities such as benches, planters, decorative lighting, and other features. None of these features are shown on the perimeter of the building on Pad 2. Please add. g. Please delete General Notes 15, 16 and 17 on Sheet 1 as they are not relative to Pad 2. h. Please delete the Building I (Home Depot) consultant information from sheet 1. i. Please revise the title of the future land use plan for adjacent properties to state "Potential Future Land Use........" Commercial areas north of the Harmony Centre should be labeled as "potential commercial". The retail site (Circuit City) should be labeled as "approved retail". The automotive (Schrader's) should be labeled as "existing automotive". j. Please revise the Site Data according to the attached format. k. Has the public street r-o-w square footage been revised to reflect the additional 2 feet added for turn -lanes? I. The building floor area listed for Pad 2 is different on Sheet 4 than each of the plan sheets. Please revise Sheet 4 accordingly. M. The maximum building height is listed as 40 feet on Sheet 1. However, the maximum building height is 25 feet according to the building elevations. Please revise Sheet 1. n. Have Sheets 2, 3 and 4 been revised to reflect the additional 2 feet of r-o-w for the turn -lanes? o. Please dimension the widths of all sidewalks, setbacks, typical parking stalls, etc. on Sheet 3. P. The Legend on Sheet 3 does not include all lighting symbols. How tall are the light poles? The trash dumpster symbol should be labeled as "trash dumpster/enclosure." q. Please indicate the color of the awnings on the building elevations and change the title in the color schedule to "fabric awnings". r. The south building elevation needs some additional architectural detail (stucco in middle, upper two panels?). S. Is there any wall signage proposed on the building elevations? Is it lighted? ... neon? t. Please label Harmony Road on Sheets 3 and 4. U. Please show Pad 2 landscaping darker and show landscaping from Harmony Centre First Filing lighter on Sheet 4. Is the Landscape Plan the same as the approved First Filing Landscape Plan? V. A minimum 5.5 foot wide planting strip for foundation plantings and trees is needed on the east side of the Pad 2 building. W. Please provide a trash enclosure elevation on Sheet 3. X. Some landscaping work is being proposed on the Schrader property, outside of the Harmony Center PUD. Have easements been obtained and submitted? Y. A Colorado Blue Spruce should be added on the south side of the building. Z. What does the dark dashed line south of Pad 2 building represent? aa. In general, the Plans submitted appear to be a CAD enlargement of the 100 scale site plan. Please make sure that light poles, landscaping, sidewalks, etc. are correctly located at this scale. Also, please coordinate the information provided on the Site, Landscape and Utility Plans. 12. Redlined plans from the Engineering Department are attached. 13. Comments from the Stormwater Utility are attached. This completes the review comments at this time. Additional comments may be forthcoming as the various departments and reviewing agencies continue to review this request. Please provide a written response to each of the above stated comments with the submittal of plan revisions. A Planning and Zoning Board date will be assigned once all comments have been addressed and revisions have been reviewed. Please contact me at 221-6206 if you have any questions or concerns related to these comments. Sincerely, Michael Ludwig, All P City Planner xc: Tim Blandford Stormwater Utility file/Project Planner Comm —pity Planning and Environmenta, ,iervices Current Planning City of Fort Collins August 20, 1997 Terry Rucker SEM Architects 7935 E. Prentice Avenue, #102 Englewood, CO 80111 Dear Terry: Staff has reviewed your plans for the Harmony Centre Pad Site 3 Final PUD that were submitted on July 16, 1997 and would like to offer the following comments: 1. The Traffic Operations Department stated that although this pad site does not include large vehicle trip generators, the developer will be held to the SH68 (Harmony Road), SH287 (College Avenue), and JFK improvements. 2. The Water Conservation Specialist stated that the landscape plan must contain a note calling for the review and approval by the City of Fort Collins of any landscape irrigation system, prior to the issuance of a Building Permit. 3. The Light and Power Utility stated that the transformer location requested by the developer will need to be changed. The transformer must be accessible from the parking lot. 4. The Advance Planning Department offers the following comments: a. There was no indication on the plans showing the location of any mechanical equipment. Please show how this equipment will be fully incorporated into the building's architecture. b. The northeast corner of the building needs an entrance and plaza to relate to the main buildings of the center. This is a prime corner. 5. The Zoning Department offers the following comments: a. Please dimension the distances of the building from the lot lines. b. Please dimension the overall building height on the building elevations. C. Please indicate the proposed/permitted land use(s) for the building within the building envelope on Sheets 2 and 3. 'RI North Colle,,C Av enue • PO. Coy 5S0 • Poi t Collins, CO 80a22-0 Il 1 7I1 2'1_�;-: n I A\ (970) 221-6378 • TDD (970) 24-600'- 6. The Building Inspection Department offers the following comments: a. Please clearly show the property lines and proximity of property lines to the proposed building on the site plans submitted with the application for building permit. b. The site shall be accessible to persons with disabilities in accordance with Uniform Building Code Section 3103 and UBC Appendix Section 3106. A designated and marked "accessible route of travel' among all the buildings on the site and building exits and entrances and the public way (public sidewalk) is shown. Accessible routes shall comply with ANSI A117.1-1992 with running slopes no greater than 1:20 and cross slopes no steeper than 1:50. Where routes cross lanes for vehicle traffic, they shall be designated and marked as a cross walk. Provide parking and signs per Appendix Section 3107. Parking and access aisles shall comply with ANSI A117.1-1992 with slopes no greater than 1:50 in any direction. C. Buildings shall be designed to comply with the Fort Collins Nonresidential Energy Code (ASHRAE 90.1 with local amendments) or residential energy code (MEC 1995 with local amendments) whichever is applicable. d. Section 504 of the 1991 edition of the Uniform Building Code as adopted by the City of Fort Collins requires that exterior walls of building 1 located closer within distances, based on use and construction type, to a property line be of fire -resistive construction. Openings are restricted or prohibited in such exterior walls. A parapet extending 30-inches above the roof surface may be required by UBC Section 1710. Projections, such as cornices, eave overhangs or exterior balconies shall not extend over the property line and must comply with UBC Sections 1710 and 504. 7. The Fort Collins -Loveland Water District and the South Fort Collins Sanitation District have reviewed the above mentioned submittal and have no objections provided all District requirements are satisfied. 8. The Natural Resources Department stated that the trash enclosure must be large enough to accommodate trash and recycling dumpsters. 9. U S WEST offers the following comments: a. Review of these plans should not be construed as a commitment that telephone facilities sufficient to serve this project are presently available. U S WEST will provide telephone service in accordance with the rates and tariffs on file with the Colorado Public Utilities Commission. b. The owner is responsible for provision of all conduit, ditch crossings, and street crossings for telephone facilities within the project. The PROJECT COMMENT SHEET City of Fort Collins Current Planning DATE: July 17, 1997 DEPT: Engineering. PROJECT: #6-96E Harmony Centre P.U.D. - Pad 2 Final (LDGS) PLANNER: Mike Ludwig All comments must be received no later than the staff review meeting: Wednesday, August 13, 1997 GENERAL COMMENTS AND CONCERNS: Date: SEE PLAN SET FOR COMMENTS AND CONCERNS. 2/12,19i Signature: CHECK IHE IF YOU WISH TO RECIIVE COPIES OF REVISIONS < PW r site Tip I""'1 _ Drainage Report _ Oler �J `— _ U�_e V_ City of Fort Collins owner also provides terminal room space (usually 8' x 4') and power for the telephone terminal, generally in a utility room. Contact the U S West engineer for conduit specifications for the telephone entrance cable. C. Any relocation of existing telephone facilities required by these plans will be paid for by the developer. 10. The Poudre Fire Authority offers the following comments: a. Fire hydrants are required with a maximum spacing of 600 feet along and "approved roadway'. Each hydrant must be capable of delivering one -thousand (1,000) gallons of water per minute at a residual pressure of twenty (20) pounds. No building can be greater than 300 feet from a fire hydrant as measured from the building to the hydrant along the approved roadway. b. A table found in the 1991 Uniform Building Code Appendix III-B relates construction and area to required fire flows. C. Proposed building (Pad 3) exceeds 5000 square feet and must be fire contained or equipped with an automated fire suppression system. (Local Amendment to Table 38B UBC). d. If building is equipped with a fire sprinkler or fire alarm system, a "knox box is required. it. The Colorado Department of Transportation offers the following comments: a. CDOT must review detailed plans for auxiliary lanes and accesses to SH68, and issue access permits in/when changes in deeded access control line are approved through CDOT's ROW Section, not before. b. CDOT has not made detailed review of auxiliary lane and access designs or reviewed issuance of access permits. The plan sets do not offer adequate detail for that level of review. 12. The Current Planning Department offers the following comments: a. The legal description on Sheet 1 of 4 should reference Pad Site 3. b. Please indicate the proposed use/tenant in the title block at the top of each page and in the title block at right hand side of each page. C. Please revise the index of drawings at to state that Sheet 2 is the overall site plan for the entire Harmony Centre; that Sheet 3 is Pad 3 Site Plan and Elevations; and that Sheet 4 is the Pad 3 Landscape Plan. d. The zoning districts indicated on the Vicinity map on Sheet 1 of 4 references zoning districts that no longer exist. Please revise the vicinity map to reference CityPlan zoning districts. e. General Note 4 on Sheet 1 references that all rooftop and ground mounted mechanical equipment will be fully screened. Please show how this will be accomplished on the building elevations and landscape plan. f. General Note 14 on Sheet 1 indicates that pedestrian plazas shall be provided with amenities such as benches, planters, decorative lighting, and other features. None of these features are shown on the perimeter of the building on Pad 3. Please add. g. Please delete General Notes 15, 16 and 17 on Sheet 1 as they are not relative to Pad 3. h. Please delete the Building I (Home Depot) consultant information from sheet 1. i. Please revise the title of the future land use plan for adjacent properties to state "Potential Future Land Use........" Commercial areas north of the Harmony Centre should be labeled as "potential commercial". The retail site (Circuit City) should be labeled as "approved retail". The automotive (Schrader's) should be labeled as "existing automotive". j. Please revise the Site Data according to the attached format. k. Has the public street r-o-w square footage been revised to reflect the additional 2 feet added for turn -lanes? I. The building floor area listed for Pad 3 is different on Sheet 4 than each of the other plan sheets. Please revise Sheet 4 accordingly. M. The maximum building height is listed as 40 feet on Sheet 1. However, the maximum building height is 23 to 24 feet according to the building elevations. Please revise Sheet 1. n. Have Sheets 2, 3, and 4 been revised to reflect the additional 2 feet of r-o-w for the turn -lanes? o. Please dimension the widths of all sidewalks, setbacks, typical parking stalls, etc. on Sheet 3. P. The sidewalks around the Pad 3 building should include a minimum 5.5 foot planting strip adjacent to the building for trees and shrubs. q. The Legend on Sheet 3 does not include all lighting symbols. How tall are the light poles? The trash dumpster symbol should be labeled as "trash dumpster/enclosure." r. Please indicate the color of the awnings on the building elevations and change the title in the color schedule to "fabric awnings". S. The south and east building elevations are pretty blank and need some additional architectural detail. t. Is the monument sign a Harmony Centre monument sign or a Pad 3 monument sign? U. Is there any wall signage proposed on the building elevations? Is it lighted? ... neon? V. Please show Pad 3 landscaping darker and show landscaping from Harmony Centre First Filing lighter on Sheet 4. Is the Landscape Plan the same as the approved First Filing Landscape Plan? W. Please provide a trash enclosure elevation on Sheet 3. X. In general, the Plans submitted appear to be a CAD enlargement of the 100 scale site plan. Please make sure that light poles, landscaping, sidewalks, etc. are correctly located at this scale. Also, please coordinate the information provided on the Site, Landscape and Utility Plans. 13. Redlined plans from the Engineering Department are attached. 14. Comments from the Stormwater Utility are attached. This completes the review comments at this time. Additional comments may be forthcoming as the various departments and reviewing agencies continue to review this request. Please provide a written response to each of the above stated comments with the submittal of plan revisions. A Planning and Zoning Board date will be assigned once all comments have been addressed and revisions have been reviewed. Please contact me at 221-6206 if you have any questions or concerns related to these comments. Sincerely, Michael Ludwig, AICP City Planner xc: Tim Blandford Stormwater Utility file/Project Planner Commu.-_cy Planning and Environmental --,rvices Current Planning City of Fort Collins August 20, 1997 Terry Rucker SEM Architects 7935 E. Prentice Avenue, #102 Englewood, CO 80111 Dear Terry: Staff has reviewed your plans for the Harmony Centre Pad Site 4 Final PUD that were submitted on July 16, 1997 and would like to offer the following comments: 1. The Traffic Operations Department stated that although this pad site does not include large vehicle trip generators, the developer will be held to the SH68 (Harmony Road), SH287 (College Avenue), and JFK improvements. 2. The Water Conservation Specialist stated that the landscape plan must contain a note calling for the review and approval by the City of Fort Collins of any landscape irrigation system, prior to the issuance of a Building Permit. 3. The Light and Power Utility stated that the transformer location requested by the applicant will need to be changed. The transformer must be accessible from the parking lot. 4. The Advance Planning Department stated that there was no indication on the plans showing the location of any mechanical equipment. Please show how this equipment will be fully incorporated into the building's architecture. 5. The Zoning Department offers the following comments: a. Is the building footprint the building envelope? If not, please dimension the envelope. b. Please dimension the distances of the building from the lot lines. C. Please dimension the overall building height on the building elevations. d. Please indicate the proposed/permitted land use(s) for the building within the building envelope on Sheets 2 and 3. 6. The Building Inspection Department offers the following comments: a. Please clearly show the property lines and proximity of property lines to the proposed building on the site plans submitted with the application for building permit. %Mth C.dlcg,e A\rcnuc • PO. Roy DSO • Port Collins, C0 8051"-0 0 j, „I 7 I- A\ (970) 21-(,378 • I DD (970) 22-1-600' b. The site shall be accessible to persons with disabilities in accordance with Uniform Building Code Section 3103 and UBC Appendix Section 3106. A designated and marked "accessible route of travel" among all the buildings on the site and building exits and entrances and the public way (public sidewalk) is shown. Accessible routes shall comply with ANSI A117.1-1992 with running slopes no greater than 1:20 and cross slopes no steeper than 1:50. Where routes cross lanes for vehicle traffic, they shall be designated and marked as a cross walk. Provide parking and signs per Appendix Section 3107. Parking and access aisles shall comply with ANSI A117.1-1992 with slopes no greater than 1:50 in any direction. C. Buildings shall be designed to comply with the Fort Collins Nonresidential Energy Code (ASHRAE 90.1 with local amendments) or residential energy code (MEC 1995 with local amendments) whichever is applicable. d. Section 504 of the 1991 edition of the Uniform Building Code as adopted by the City of Fort Collins requires that exterior walls of building 1 located closer within distances, based on use and construction type, to a property line be of fire -resistive construction. Openings are restricted or prohibited in such exterior walls. A parapet extending 30-inches above the roof surface may be required by UBC Section 1710. Projections, such as cornices, eave overhangs or exterior balconies shall not extend over the property line and must comply with UBC Sections 1710 and 504. 7. The Transportation Planning Department requests that a sidewalk be provided along the eastern edge of the parking to the north of the Pad 4 building. 8. The Fort Collins -Loveland Water District and the South Fort Collins Sanitation District have reviewed the above mentioned submittal and have no objections provided all District requirements are satisfied. 9. The Natural Resources Department stated that the trash enclosure must be large enough to accommodate trash and recycling dumpsters. 10. U S WEST offers the following comments: a. Review of these plans should not be construed as a commitment that telephone facilities sufficient to serve this project are presently available. U S WEST will provide telephone service in accordance with the rates and tariffs on file with the Colorado Public Utilities Commission. b. The owner is responsible for provision of all conduit, ditch crossings, and street crossings for telephone facilities within the project. The owner also provides terminal room space (usually 8' x 4') and power for the telephone terminal, generally in a utility room. Contact the U S West engineer for conduit specifications for the telephone entrance cable. C. Any relocation of existing telephone facilities required by these plans will be paid for by the developer. 11. The Poudre Fire Authority offers the following comments: a. Fire hydrants are required with a maximum spacing of 600 feet along and "approved roadway'. Each hydrant must be capable of delivering one -thousand (1,000) gallons of water per minute at a residual pressure of twenty (20) pounds. No building can be greater than 300 feet from a fire hydrant as measured from the building to the hydrant along the approved roadway. b. A table found in the 1991 Uniform Building Code Appendix III-B relates construction and area to required fire flows. C. Proposed building (Pad 4) exceeds 5000 square feet and must be fire contained or equipped with an automated fire suppression system. (Local Amendment to Table 38B UBC). d. If building is equipped with a fire sprinkler or fire alarm system, a "knox box is required. 12. The Colorado Department of Transportation offers the following comments: a. CDOT must review detailed plans for auxiliary lanes and accesses to SH68, and issue access permits in/when changes in deeded access control line are approved through CDOT's ROW Section, not before. b. CDOT has not made detailed review of auxiliary lane and access designs or reviewed issuance of access permits. The plan sets do not offer adequate detail for that level of review. 13. The Current Planning Department offers the following comments: a. The legal description on Sheet 1 of 4 should reference Pad Site 4. b. Please indicate the proposed use/tenant in the title block at the top of each page and in the title block at right hand side of each page. C. Please revise the index of drawings at to state that Sheet 2 is the overall site plan for the entire Harmony Centre; that Sheet 3 is Pad 4 Site Plan and Elevations; and that Sheet 4 is the Pad 4 Landscape Plan. d. The zoning districts indicated on the Vicinity map on Sheet 1 of 4 references zoning districts that no longer exist. Please revise the vicinity map to reference CityPlan zoning districts. e. General Note 4 on Sheet 1 references that all rooftop and ground mounted mechanical equipment will be fully screened. Please show how this will be accomplished on the building elevations and landscape plan. f. General Note 14 on Sheet 1 indicates that pedestrian plazas shall be provided with amenities such as benches, planters, decorative lighting, and other features. None of these features are shown on the perimeter of the building on Pad 4. Please add. g. Please delete General Notes 15, 16 and 17 on Sheet 1 as they are not relative to Pad 4. h. Please delete the Building I (Home Depot) consultant information from Sheet 1. Please revise the title of the future land use plan for adjacent properties to state "Potential Future Land Use........" Commercial areas north of the Harmony Centre should be labeled as "potential commercial". The retail site (Circuit City) should be labeled as "approved retail". The automotive (Schrader's) should be labeled as "existing automotive". Please revise the Site Data according to the attached format. k. The building footprint has increased and setback decreased (10 feet) at the northeast corner of the Pad 4 building. This is a significant change and may not be in compliance with the approved Preliminary PUD. It is also not consistent with the Utility Plans. This must be discussed further. I. The building floor area listed for Pad 4 is different on Sheet 4 than on each of the other plan sheets. Please revise all sheets accordingly. M. The maximum building height is listed as 40 feet on Sheet 1. However, the maximum building height is 23 to 24 feet according to the building elevations. Please revise Sheet 1. n. Please dimension the widths of all sidewalks, setbacks, typical parking stalls, etc. on Sheet 3. o. A minimum 5.5 foot planting strip adjacent to the west side of the building is needed for trees and shrubs. P. The Legend on Sheet 3 does not include all lighting symbols. How tall are the light poles? The trash dumpster symbol should be labeled as "trash dumpster/enclosure." q. Please indicate the color of the awnings on the building elevations and change the title in the color schedule to "fabric awnings". r. Is the monument sign a Harmony Centre monument sign? S. Is there any wall signage or window signage proposed on the building elevations? Is it lighted? ... neon? Please show Pad 4 landscaping darker and show landscaping from Harmony Centre First Filing lighter on Sheet 4. Is the Landscape Plan the same as the approved First Filing Landscape Plan? U. Please provide a trash enclosure elevation on Sheet 3. V. In general, the Plans submitted appear to be a CAD enlargement of the 100 scale site plan. Please make sure that light poles, landscaping, sidewalks, etc. are correctly located at this scale. Also, please coordinate the information provided on the Site, Landscape and Utility Plans. 14. Redlined plans from the Engineering Department are attached. 15. Comments from the Stormwater Utility are attached. This completes the review comments at this time. Additional comments may be forthcoming as the various departments and reviewing agencies continue to review this request. Please provide a written response to each of the above stated comments with the submittal of plan revisions. A Planning and Zoning Board date will be assigned once all comments have been addressed and revisions have been reviewed. Please contact me at 221-6206 if you have any questions or concerns related to these comments. Sincerely, 1� Michael Ludwig, AICP City Planner xc: Tim Blandford Stormwater Utility file/Project Planner Planning and Environmental'ervices Current Planning City of Fort Collins August 20, 1997 Terry Rucker SEM Architects 7935 E. Prentice Avenue, #102 Englewood, CO 80111 Dear Terry: Staff has reviewed your plans for the Harmony Centre Pad Site 5 Final PUD that were submitted on July 16, 1997 and would like to offer the following comments: 1. The Traffic Operations Department stated that although this pad site does not include large vehicle trip generators, the developer will be held to the SH68 (Harmony Road), SH287 (College Avenue), and JFK improvements. 2. The Water Conservation Specialist stated that the landscape plan must contain a note calling for the review and approval by the City of Fort Collins of any landscape irrigation system, prior to the issuance of a Building Permit. 3. The Light and Power Utility stated that the transformer location requested by the developer will need to be changed. The transformer must be accessible from the parking lot. 4. The Advance Planning Department offers the following comments: a. There was no indication on the plans showing the location of any mechanical equipment. Please show how this equipment will be fully incorporated into the building's architecture. b. The sidewalk on the north side of the Pad 5 building should be redesigned. A person will not walk on a 5 foot wide sidewalk directly adjacent to the north side of the building. Please narrow the width of the median and provide a 13 foot wide walk with approximately 3 five foot wide cut-outs (tree grates). 5. The Zoning Department offers the following comments: a. Please dimension the distances of the building from the lot lines. b. Please dimension the overall building height on the building elevations. C. Please indicate the proposed/permitted land use(s) for the building within the building envelope on Sheets 2 and 3. I No!th College A��enur f10. Buy;®0 • fort Collin, <_O y;l;�^-r• PAX 19:0) 221 TDD (970) 221-hun_ 6. The Building Inspection Department offers the following comments: a. The site shall be accessible to persons with disabilities in accordance with Uniform Building Code Section 3103 and UBC Appendix Section 3106. A designated and marked "accessible route of travel' among all the buildings on the site and building exits and entrances and the public way (public sidewalk) is shown. Accessible routes shall comply with ANSI A117.1-1992 with running slopes no greater than 1:20 and cross slopes no steeper than 1:50. Where routes cross lanes for vehicle traffic, they shall be designated and marked as a cross walk. Provide parking and signs per Appendix Section 3107. Parking and access aisles shall comply with ANSI At17.1-1992 with slopes no greater than 1:50 in any direction. b. Buildings shall be designed to comply with the Fort Collins Nonresidential Energy Code (ASHRAE 90.1 with local amendments) or residential energy code (MEC 1995 with local amendments) whichever is applicable. C. Food service establishments require approval by the Larimer County Health Department at the time of building permit application. Please contact Jim Devore at (970)498-6775. d. Section 504 of the 1991 edition of the Uniform Building Code as adopted by the City of Fort Collins requires that exterior walls of building 1 located closer within distances, based on use and construction type, to a property line be of fire -resistive construction. Openings are restricted or prohibited in such exterior walls. A parapet extending 30-inches above the roof surface may be required by UBC Section 1710. Projections, such as cornices, eave overhangs or exterior balconies shall not extend over the property line and must comply with UBC Sections 1710 and 504. 7. The Transportation Planning Department offers the following comments: a. Please provide a 6 foot wide sidewalk along the parking on the east side of the Pad 5 building. b. Please provide an opening or alternative in the 30" high screen wall southeast of Pad 5 to accommodate pedestrian access to the buildings from a future bus stop on Harmony Road. 8. The Fort Collins -Loveland Water District and the South Fort Collins Sanitation District have reviewed the above mentioned submittal and have no objections provided all District requirements are satisfied. 9. The Natural Resources Department stated that the trash enclosure must be large; enough to accommodate trash and recycling dumpsters. PROJECT COMMENT SHEET City of Fort Collins Current Planning DATE: July 17, 1997 DEPT: Engineering. PROJECT: #6-96F Harmony Centre P.U.D. - Pad 3 Final (LDGS) PLANNER: Mike Ludwig All comments must be received no later than the staff review meeting: Wednesday, August 13, 1997 GENERAL COMMENTS AND CONCERNS: SEE PLAN SET FOR COMMENTS AND CONCERNS. Date: CHECK HE )F YOU WISH TO RECEIVE COPIES OF REVISIONS Plat x. Sk Or 1" _ qe Report _ Oler Utlllty �� Redline Utlllty "Collins City of Fort Clli - Re 10. U S WEST offers the following comments: a. Review of these plans should not be construed as a commitment that telephone facilities sufficient to serve this project are presently available. U S WEST will provide telephone service in accordance with the rates and tariffs on file with the Colorado Public Utilities Commission. b. The owner is responsible for provision of all conduit, ditch crossings, and street crossings for telephone facilities within the project. The owner also provides terminal room space (usually 8' x 4') and power for the telephone terminal, generally in a utility room. Contact the U S West engineer for conduit specifications for the telephone entrance cable. C. Any relocation of existing telephone facilities required by these plans will be paid for by the developer. 11. The Poudre Fire Authority offers the following comments: a. Fire hydrants are required with a maximum spacing of 600 feet along and "approved roadway". Each hydrant must be capable of delivering one -thousand (1,000) gallons of water per minute at a residual pressure of twenty (20) pounds. No building can be greater than 300 fleet from a fire hydrant as measured from the building to the hydrant along the approved roadway. b. A table found in the 1991 Uniform Building Code Appendix III-B relates construction and area to required fire flows. C. Proposed building (Pad 5) exceeds 5000 square feet and must be fire contained or equipped with an automated fire suppression system. (Local Amendment to Table 38B UBC). d. If building is equipped with a fire sprinkler or fire alarm system, a "Iknox box is required. 12. The Colorado Department of Transportation offers the following comments: a. CDOT must review detailed plans for auxiliary lanes and accesses to SH68, and issue access permits in/when changes in deeded access control line are approved through CDOT's ROW Section, not before. b. ("DOT has not made detailed review of auxiliary lane and access designs or reviewed issuance of access permits. The plan sets do riot offer adequate detail for that level of review. 13. The Current Planning Department offers the following comments: a. The legal description on Sheet 1 of 4 should reference Pad Site 5. b. Please indicate the proposed use/tenant in the title block at the top of each page and in the title block at right hand side of each page. C. Please revise the index of drawings at to state that Sheet 2 is the overall site plan for the entire Harmony Centre; that Sheet 3 is Pad 5 Site Plan and Elevations; and that Sheet 4 is the Pad 5 Landscape Plan. d. The zoning districts indicated on the Vicinity map on Sheet 1 of 4 references zoning districts that no longer exist. Please revise the vicinity map to reference CityPlan zoning districts. e. General Note 4 on Sheet 1 references that all rooftop and ground mounted mechanical equipment will be fully screened. Please show how this will be accomplished on the building elevations and landscape plan. f. General Note 14 on Sheet 1 indicates that pedestrian plazas shall be provided with amenities such as benches, planters, decorative lighting, and other features. None of these features are shown on the perimeter of the building on Pad 5. Please add. g. Please delete General Notes 15, 16 and 17 on Sheet 1 as they are not relative to Pad 5. h. Please delete the Building I (Home Depot) consultant information from sheet 1. i. Please revise the title of the future land use plan for adjacent properties to state "Potential Future Land Use........" Commercial areas north of the Harmony Centre should be labeled as "potential commercial". The retail site (Circuit City) should be labeled as "approved retail". The automotive (Schrader's) should be labeled as "existing automotive". j. Please revise the Site Data according to the attached format. k. Has the public street r-o-w square footage been revised to reflect the additional 2 feet added for turn -lanes? I. The maximum building height is listed as 40 feet on Sheet 1. However, the maximum building height is 25 feet according to the building elevations. Please revise Sheet 1. M. Has Sheet 2 been revised to reflect the additional 2 feet of r-o-w for the turn -lanes? n. Please dimension the widths of all sidewalks, setbacks, typical parking stalls, etc. on Sheet 3. o. The Legend on Sheet 3 does not include all lighting symbols. How tall are the light poles? The trash dumpster symbol should be labeled as "trash dumpster/enclosure." P. Please indicate the color of the awnings on the building elevations and change the title in the color schedule to "fabric awnings". q. The east building elevation has no relation to the adjacent parking. r. Is the red brick banded in color? texture? Please clarify. S. Is there any wall signage proposed on the building elevations? Is it lighted? ... neon? t. Please show Pad 5 landscaping darker and show landscaping from Harmony Centre First Filing lighter on Sheet 4. Is the Landscape Plan the same as the approved First Filing Landscape Plan? u. The bike rack must be permanently anchored to concrete and not impede pedestrian travel. V. Tree protection notes must be added to the plans. W. Evergreen shrubs are needed around the perimeter of the trash enclosure. X. Please provide a trash enclosure elevation on Sheet 3. Y. In general, the Plans submitted appear to be a CAD enlargement of the 100 scale site plan. Please make sure that light poles, landscaping, sidewalks, etc. are correctly located at this scale. Also, please coordinate the information provided on the Site, Landscape and Utility Plans. 14. Redlined plans from the Engineering Department are attached. 15. Comments from the Stormwater Utility are attached. This completes the review comments at this time. Additional comments may be forthcoming as the various departments and reviewing agencies continue to review this request. Please provide a written response to each of the above stated comments with the submittal of plan revisions. A Planning and Zoning Board date will be assigned once all comments have been addressed and revisions have been reviewed. Please contact me at 221-6206 if you have any questions or concerns related to these comments. Sincerely, Michael Ludwig, AICP City Planner xc: Tim Blandford Stormwater Utility file/Project Planner Commu._ _cy Planning and Environmental _ .!rvices Current Planning City of Fort Collins August 20, 1997 Terry Rucker SEM Architects 7935 E. Prentice Avenue, #102 Englewood, CO 80111 Dear Terry: Staff has reviewed your plans for the Harmony Centre Pad Site 6 Final PUD that were submitted on July 16, 1997 and would like to offer the following comments: 1. The Traffic Operations Department stated that although this pad site does not include large vehicle trip generators, the developer will be held to the SH68 (Harmony Road), SH287 (College Avenue), and JFK improvements. 2. The Waiter Conservation Specialist stated that the landscape plan must contain a note calling for the review and approval by the City of Fort Collins of any landscape irrigation system, prior to the issuance of a Building Permit. 3. The Light and Power Utility stated that the proposed transformer is located under a tree. Please move the transformer. 4. The Advance Planning Department offers the following comments: a. There was no indication on the plans showing the location of any mechanical equipment. Please show how this equipment will be fully incorporated into the building's architecture. b. Trees are needed on the west side of the Pad 6 building in tree -wells along the sidewalk. 5. The Zoning Department offers the following comments: a. One additional handicap stall is needed as a total of 3 are required. b. Please dimension the distances of the building from the lot lines. C. Please dimension the overall building height on the building elevations. d. Please indicate the proposed/permitted land use(s) for the building within the building envelope on Sheets 2 and 3. I 'Forth Collcnc Av unue • NO. Bos N8(1 • Fort Collins, CO 50�22-0�.t Y:iX (970) 221-6 78 • I DD (9;0) 22-1-0002 6. The Building Inspection Department offers the following comments: a. Please clearly show the property lines and proximity of property lines to the proposed building on the site plans submitted with the application for building permit. b. The site shall be accessible to persons with disabilities in accordance with Uniform Building Code Section 3103 and UBC Appendix Section 3106. A designated and marked "accessible route of travel' among all the buildings on the site and building exits and entrances and the public way (public sidewalk) is shown. Accessible routes shall comply with ANSI A117.1-1992 with running slopes no greater than 1:20 and cross slopes no steeper than 1:50. Where routes cross lanes for vehicle traffic, they shall be designated and marked as a cross walk. Provide parking and signs per Appendix Section 3107. Parking and access aisles shall comply with ANSI A117.1-1992 with slopes no greater than 1:50 in any direction. C. Buildings shall be designed to comply with the Fort Collins Nonresidential Energy Code (ASHRAE 90.1 with local amendments) or residential energy code (MEC 1995 with local amendments) whichever is applicable. d. Section 504 of the 1991 edition of the Uniform Building Code as adopted by the City of Fort Collins requires that exterior walls of building 1 located closer within distances, based on use and construction type, to a property line be of fire -resistive construction. Openings are restricted or prohibited in such exterior walls. A parapet extending 30-inches above the roof surface may be required by UBC Section 1710. Projections, such as cornices, eave overhangs or exterior balconies shall not extend over the property line and must comply with UBC Sections 1710 and 504. 7. The Transportation Planning Department offers the following comments: a. Please provide a sidewalk connection on the north side of the Pad 6 building to JFK Parkway. b. A southeast building entrance would relate well to JFK and Harmony. The Fort Collins -Loveland Water District and the South Fort Collins Sanitation District have reviewed the above mentioned submittal and have no objections provided all District requirements are satisfied. 9. The Natural Resources Department stated that the trash enclosure must be large enough to accommodate trash and recycling dumpsters. 10. U S WEST offers the following comments: a. Review of these plans should not be construed as a commitment that telephone facilities sufficient to serve this project are presently available. U S WEST will provide telephone service in accordance with the rates and tariffs on file with the Colorado Public Utilities Commission. b. The owner is responsible for provision of all conduit, ditch crossings, and street crossings for telephone facilities within the project. The owner also provides terminal room space (usually 8' x 4') and power for the telephone terminal, generally in a utility room. Contact the U S West engineer for conduit specifications for the telephone entrance cable. C. Any relocation of existing telephone facilities required by these plans will be paid for by the developer. 11. The Poudre Fire Authority offers the following comments: a. Fire hydrants are required with a maximum spacing of 600 feet along and "approved roadway". Each hydrant must be capable of delivering one -thousand (1,000) gallons of water per minute at a residual pressure of twenty (20) pounds. No building can be greater than 300 feet from a fire hydrant as measured from the building to the hydrant along the approved roadway. b. A table found in the 1991 Uniform Building Code Appendix III-B relates construction and area to required fire flows. C. Proposed building (Pad 6) exceeds 5000 square feet and must be fire contained or equipped with an automated fire suppression system. (Local Amendment to Table 38B UBC). d. If building is equipped with a fire sprinkler or fire alarm system, a "knox box is required. 12. The Colorado Department of Transportation offers the following comments: a. CDOT must review detailed plans for auxiliary lanes and accesses to SH68, and issue access permits in/when changes in deeded access control line are approved through CDOT's ROW Section, not before. b. C:DOT has not made detailed review of auxiliary lane and access designs or reviewed issuance of access permits. The plan sets do not offer adequate detail for that level of review. 13. The Current Planning Department offers the following comments: a. The legal description on Sheet 1 of 4 should reference Pad Site 6. b. Please indicate the proposed use/tenant in the title block at the top of each page and in the title block at right hand side of each page. C. Please revise the index of drawings at to state that Sheet 2 is the overall site plan for the entire Harmony Centre; that Sheet 3 is Pad 6 Site Plan and Elevations; and that Sheet 4 is the Pad 6 Landscape Plan. d. The zoning districts indicated on the Vicinity map on Sheet 1 of 4 references zoning districts that no longer exist. Please revise the vicinity map to reference CityPlan zoning districts. e. General Note 4 on Sheet 1 references that all rooftop and ground mounted mechanical equipment will be fully screened. Please show how this will be accomplished on the building elevations and landscape plan. f. General Note 14 on Sheet 1 indicates that pedestrian plazas shall be provided with amenities such as benches, planters, decorative lighting, and other features. None of these features are shown on the perimeter of the building on Pad 6. Please add. g. Please delete General Notes 15, 16 and 17 on Sheet 1 as they are riot relative to Pad 6. h. Please delete the Building I (Home Depot) consultant information from sheet 1. Please revise the title of the future land use plan for adjacent properties to state "Potential Future Land Use........" Commercial areas north of the Harmony Centre should be labeled as "potential commercial". The retail site (Circuit City) should be labeled as "approved retail". The automotive (Schrader's) should be labeled as "existing automotive". j. Please revise the Site Data according to the attached format. k. Has the public street r-o-w square footage been revised to reflect the additional 2 feet added for turn -lanes? I. The building floor area listed for the Pad 6 building is 2,200 square feet larger than the Preliminary PUD approval. This has significantly reduced the building setback from Harmony Road (now 6 feet, was 20 feet) and is not in substantial compliance with the approved Preliminary PUD. M. The maximum building height is listed as 40 feet on Sheet 1. However, the maximum building height is 28 feet according to the building elevations. Please revise Sheet 1. n. Has Sheet 2 been revised to reflect the additional 2 feet of r-o-w for the turn -lanes? o. Please dimension the widths of all sidewalks, setbacks, typical parking stalls, etc. on Sheet 3. P. The Legend on Sheet 3 does not include all lighting symbols. How tall are the light poles? The trash dumpster symbol should be labeled as "trash dumpster/enclosure." q. Please indicate the color of the awnings on the building elevations and change the title in the color schedule to "fabric awnings". r. The Pad 6 building elevations do not appear to have the architectural quality of the other five pads. All elevations need additional detail, especially the north and south. Are the columns three dimensional? Please eliminate the caps on the columns. Awnings should be added. S. Is the monument sign a Harmony Centre monument sign or a Pad 6 monument sign? t. Is there any wall signage proposed on the building elevations? Is it lighted? ... neon? U. Please label JFK Parkway on Sheets 3 and 4. V. Please show Pad 6 landscaping darker and show landscaping from Harmony Centre First Filing lighter on Sheet 4. Is the Landscape Plan the same as the approved First Filing Landscape Plan? W. Please provide a trash enclosure elevation on Sheet 3. X. Evergreen shrubs are needed along the south and east building foundation. Y. In general, the Plans submitted appear to be a CAD enlargement of the 100 scale site plan. Please make sure that light poles, landscaping, sidewalks, etc. are correctly located at this scale. Also, please coordinate the information provided on the Site, Landscape and Utility Plans. 14. Redlined plans from the Engineering Department are attached. 15. Comments from the Stormwater Utility are attached. This completes the review comments at this time. Additional comments may be forthcoming as the various departments and reviewing agencies continue to review this request. Please provide a written response to each of the above stated comments with the submittal of plan revisions. A Planning and Zoning Board date will be assigned once all comments have been addressed and revisions have been reviewed. Please contact me at 221-6206 if you have any questions or concerns related to these comments. Sincerely, Michael Ludwig, AICP City Planner xc: Tim Blandford Stormwater Utility file/Project Planner PROJECT COMMENT SHEET City of Fort Collins Current Planning DATE: July 17, 1997 DEPT: Engineering. PROJECT: #6-96G Harmony Centre P.U.D. - Pad 4 Final (LDGS) PLANNER: Mike Ludwig All comments must be received no later than the staff review meeting: Wednesday, August 13, 1997 GENERAL COMMENTS AND CONCERNS: SEE PLAN SET FOR COMMENTS AND CONCERNS. Date: CHECK IIERRE IF YOU WISH TO RECEIVE COPIES OF REVISIONS x PHt x Siv _ Report _ Oler _ U0 c. Redline Utility, , Imds* City of Fort Collins REVISION COMMENT SHEET DATE: November 13, 1997 TO: Engineering PROJECT: #6-96D Harmony Centre P.U.D., Pad 4 (LDGS) Final All comments must be received by Mike Ludwig no later than the staff review meeting: Wednesday, December 10,1997 Note: For those requesting plat and utility drawings, see I st filing utility plans and overall plat for Harmony Centre. GENERAL COMMENTS: • No comments at this time. Date: CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVLSIONS _ PW _ Site — Dm&e Rpft— Oda _ Ufil _ Rdz llhllty _ I,ea&W City of Fort Collins t' Ak DATE: November 13, 1997 TO: Engineering PROJECT: #6-96D Harmony Centre P.U.D., Pad I (LDGS) Final All comments must be received by Mike Ludwig no later than the staff review meeting: Wednesday, December 10,1997 Note: For those requesting plat and utility drawings, see 1st filing utility plans and overall plat for Harmony Centre. GENERAL COMMENTS: • Contact Public Service Company about constructing the trash enclosure within their easement. They mat require you to relocate the trash enclosure. • The back of walk along College Avenue needs to back up to the ROW. Date: 12A 1`1`7 Signature CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS -Pit _ Site _ Drainage Report -Utility _ Redline UWq _ Iaadsape City of Fort Collins i ya` e'er DATE: January 15, 1998 TO: Engineering PROJECT: #6-96G Harmony Centre P.U.D., Pad Site 4 (LDGS) Final All comments must be received by Mike Ludwig no later than the staff review meeting: *Wednesday, January 21,1998 **The following drawings address the remaining issues for this project. No other drawings (i.e. utility plans) require further review; therefore, this packet should be viewed as complete and ready to be discussed next Wednesday. ivy c�trtslyr� Date: i /—i /Sa CIIECK HERE IF YOU WISH TO RECEIVE Plat _ Site _ Utility _ Redline Utility Signature: CIY' COPIES OF REVISIONS _ Ora * Report _ Other LaDds* City of Fort Collins REVISION COMMENT SHEET DATE: February 18, 1998 TO: Engineering PROJECT: #6-96D Harmony Centre P.U.D., Pad 1 - (LDGS) Final All comments must be received by Mike Ludwig no later than the staff review meeting: Wednesday, February 25,1998 GENERAL COMMENTS: You will need to acquire an access easement along the north side of the Schrader property for vehicles entering into the drive-thru. Date: 21 zv 198 CHECK HERE IF YOU WIM TO RECEIVE COPIES OF REVISIONS Utility _ Retiline Utility _ landscape City of Fort Collins Common' Planning and Environmental S Current Planning City of Fort Collins August 20, 1998 Terry Rucker SEM Architects 677 S. Colorado Blvd., Suite 200 Denver, CO 80246 Dear Terry: ices Staff has reviewed your plans for the Harmony Centre Pad Site 3 PDP/Final that were submitted on July 21, 1998 and offers the following comments: 1. The Larimer Ditch # 2 Canal Company stated that ditch work was previously approved and completed. If no disturbance or changes are proposed, the Ditch Company has no issues. 2. The Zoning Department stated the following: a. The parking aisle northwest of the building is a continuous row of 21 parking spaces. Please add a landscaped island at the midpoint of the parking row. b. Please do not show tenant signage on the building elevations. The property is located outside of the residential neighborhood sign district. All signage must be in accordance with the Sign Code. 3. Please contact the Light and Power Utility at 221-6700 when the property is ready to develop. 4. The Building Inspections Department stated the following comments: a. Accessible exterior wheelchair routes and parking facilities shall be provided with each phase of the development in accordance with Uniform Building Code Chapter 11, Appendix Chapter 11, Division I and the American National Standards Institute Publication A117.1- 1992 titled Accessible and Usable Buildings and Facilities. Accessible parking spaces are eight feet wide with a five feet wide adjacent access aisle. Slopes for parking and access aisles shall not exceed 1:50 in any direction. b. Buildings larger than 5,000 square feet shall be equipped with an automatic fire -suppression system throughout in accordance with Uniform Building Code Section 904.2.2 as amended by the City of Fort Collins. 281 Nnrf h COIIC;;C ' VCOMIC • P.O. Bux 580 • Fort Collins, CO--80522-0580 • (970) 221-0750 • FAX (970) 416-2020 C. Buildings shall be designed to comply with the Fort Collins Energy Codes. The residential code is an amended version of the 1995 Model Energy Code and the nonresidential code is based on ASHRAE/IES (American Society of Heating, Refrigerating and Air- conditioning Engineers / Illuminating Engineering Society) 90.1-1989. 5. The Poudre Fire Authority stated the following: a. Fire apparatus access roads shall be provided for every facility, building or portion of a building hereafter constructed or moved into or within the jurisdiction when any portion of the facility or any portion of an exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as measured by an approved route around the exterior of the building or facility. This fire lane shall be visible by painting and signage, and maintained unobstructed. A fire lane plan shall be submitted for approval prior to installation. Any building not meeting this criteria shall be fire sprinklered. This building is out of access A fire sprinkler system is required. b. Address numerals shall be visible from the street fronting the property, and posted with a minimum of 6-inch numerals on a contrasting background (bronze numerals on brown brick is not acceptable). C. The proposed building exceeds 5,000 square feet for Type V construction and must be fire contained or fire sprinklered. d. Fire hydrants are required with a maximum spacing of 600 feet along an approved roadway. Each hydrant must be capable of delivering 1000 gallons of water per minute at a residual pressure of 20 psi. Hydrants shall be of an approved type as defined by the Water Utility and the Poudre Fire Authority. 6. The Current Planning Department stated the following: a. Please include tree species, size and quantities in the plant list. Minimum species diversity must be in accordance with Section 3.2.1 [D][3] of the Land Use Code. b. A minimum 5-foot wide planting bed is required along at least 50% of the foundation on the west side of the building in accordance with Section 3.2.1 [E][21[d] of the Land Use Code. C. Landscaped islands are required at the north and south ends of the parking row on the west side of the building in accordance with Section 3.2.2[E][41 of the Land Use Code. A standard parking space will need to be eliminated so that the handicap accessible parking spaces may be shifted. The bike rack may need to be relocated. d. Per Section 3.5.3[C] of the Land Use Code, the building height to width ratio may not exceed 1:3 without substantial variation in the massing that includes a change in height and a projecting or recessed element. Please add arch features to the north and south building elevations that are similar to those proposed on the east and west elevations. Please refer to the redlined building elevations for further guidance. f. Please show the location of the transformer on the Site and Landscape Plans. It must be located no more than 10 feet from a paved surface and must be screened from view. g. A redlined plan set is attached. Please return the redlined set with plan revisions to the Current Planning Department. This completes the review comments at this time. Additional comments may be forthcoming as the various departments and reviewing agencies continue to review this request. Please provide a written response to each of the above stated comments with the submittal of plan revisions. A Planning and Zoning Board date will be assigned once all comments have been addressed and revisions have been reviewed. Please contact me at 221-6206 if you have any questions or concerns related to these comments. Sincerely, .Z1 Michael Ludwig, AICP City Planner xc: Tim Blandford Stormwater Utility Current Planning File #6-96J PROJECT COMMENT SHEET City of Fort Collins Current Planning DATE: December 24, 1998 TO: Engineering PROJECT: #6-96L Harmony Centre P.U.D., Pad 2 - Final Compliance - Type II (LUC) All comments must be received by Ron Fuchs no later than the staff review meeting: January 13, 1998 MAJOR COMMENTS: • no comments. Date: CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS _ Plat _ Site _ Drainage Report _ Ok Utility _ Reline Utility _ Landscape PROJECT COMMENT SHEET City of Fort Collins Current Planning DATE: December 24, 1998 TO: Engineering PROJECT: #6-96K Harmony Centre P.U.D., Pad 6 - Final Compliance - Type II (LUC) All comments must be received by Ron Fuchs no later than the staff review meeting: January 13, 1998 MAJOR COMMENTS: • no comments. Date: CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS _ Plat _ Site— Draiaage Report _ Other Utility— Redline Utility _ Landscape REVISION COMMENT SHEET DATE: February 18, 1999 TO: Engineering PROJECT: #6-96L Harmony Centre, Pad 2 — PDP — Final All comments must be received by Ron Fuchs no later than the staff review meeting: Wednesday, March 10, 1999 ❑� No Comment 1-1 Problems or Concerns (see below or attached) Date: CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS Plat Site _ Drainage Report _ Other _ Utility _ Redline Utility _ Landscape PROJECT COMMENT SHEET City of Fort Collins Current Planning DATE: July 17, 1997 DEPT: Engineering. PROJECT: #6-96H Harmony Centre P.U.D. - Pad 5 Final (LDGS) PLANNER: Mike Ludwig All comments must be received no later than the staff review meeting: Wednesday, August 13, 1997 GENERAL COMMENTS AND CONCERNS: SEE PLAN SET FOR COMMENTS AND CONCERNS. Date: CHECK HERE lF YOU WISH TO RECEIVE COPIES OF REVISIONS X Plat Sk _hW RqW _Oda _ UWdY Refine Ut V _ Lad* r City of Fort Collins REVISION COMMENT SHEET DATE: February 18, 1999 TO: Engineering PROJECT: #6-96K Harmony Centre, Pad 6 — PDP — Final All comments must be received by Ron Fuchs no later than the staff review meeting: Wednesday, March 10, 1999 ElNo Comment ❑� Problems or Concerns (see below or attached) MAJOR COMMENTS: • You will need to construct the concrete pad for the bus shelter and escrow funds for the shelter itself. Please coordinate with Traffic and Transfort on the location of the pad. Coordinate with Transfort regarding the amount needing to be escrowed. Date: CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS Plat _ Site _ llrmW Report _ Other _ Utility _ Redline Utility _ Landscape Citv of Fort Collins PROJECT COMMENT SHEET City of Fort Collins Current Planning DATE: November 17, 1999 DEPT: Engineering PROTECT: #6-96M Harmony Centre Pad 5-Type I-PDP PLANNER: ENGINEER: Ron Fuchs Mark McCallum All comments must be received by: 12/15/98 General Comments ♦ See redline comments on all redlined comments. ♦ The proposed parking stall dimensions do not meet criteria in the Land Use Code (LUC). Please see LUC Section 3 2.2(L)(I )-Table A. As shown on Table A for a 60-deg. parking stall, the width is 9 feet, the length (dimension shown on the site plan) is 21 feet, and the drive aisle width is 20 feet. Also, the Poudre Fire Authority might need an obstructed fire lane width of 20 feet (LUC Section 3.6.6(D)(2). Please check with Ron Gonzales with PFA. ♦ Please Zabel all easements on the site plan. ♦ Please provide a scale for the overall site plan (or context plan). Date: 141s Signature: PLEASE SEND COPIES ❑ BCAT OF MARKED REVISIONS: EYSITE ❑ J TILITY El NO COMMENTS — SUBMIT MYLARS LANDSCAPE PROJECT i.... COMMENT SHEET City of Fort Collins Current Plannine DATE: November 17, 1999 TO: Engineering/Pavement PROJECT: #6-96M Harmony Centre Pad 5 — Type I — PDP (LUC) All comments must be received by Ron Fuchs no later than the staff review meeting: December 15, 1999 NO co M nip arc ' /z-/,-/--,�19 /I �7 /2cv, /��— CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS _Plat _Site _Drainage Report _Other _Utility _Redline Utility _Landscape city of Fort colons /AMM PROJECT INKu"I COMMENT SHEET City of Fort Collins Current Planning DATE: November 17, 1999 TO: Street Oversizing PROJECT: #6-96M Harmony Centre Pad 5 — Type I — PDP (LUC) All comments must be received by Ron Fuchs no later than the staff review meeting: December 15, 1999 CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS Plat Site __Drainage Report Other. _Utility Rcdline Utility _Landscape 6a City of Fort Collins Mark McCallum - Harmony Centre Pad 5 fast comments.doc Page 1 December 22, 1999 Mr. Patrick Beaton Michael Brendle Architects 1743 Wazee, Suite 400 Denver, CO 80202 RE: Harmony Centre Pad Site 5 Dear Mr. Beaton: This letter is in response to plans for Harmony Centre Pad 5 Project Development Plan (Planning File #6-96M) submitted on November 17, 1999. Please note that staff reviewed your plans and the Planning Division mailed a request for comments to several public agencies and departments. This development proposal is subject to and shall comply with all requirements set forth in the City's Land Use Code (LUC), specifically: Articles 2. Administration (Development Review Procedures), Article 3. General Development Standards, Article 4. [Zoning] Districts, and, The Harmony Corridor Plan. The City of Fort Collins Land Use Code (LUC) requires that throughout all land use proceedings, the burden to comply with all applicable standards rest with the applicant. The site lies within the Harmony Centre PUD. The Harmony Centre Planned Unit Development was originally reviewed as an LDGS project and due to Ordinance 161, the subject application is now subject to Land Use Code. Staff, after reviewing materials submitted by the applicant, finds that revisions/re-design to the submitted plans dated 11/17/99 are warranted to meet the Land Use Code, The Harmony Corridor Plan, and the City of Fort Collins Development Manual. The following lists the agencies and departments that responded with their comments attached. A. Park Planning: submitted a response to the checklist and it is attached to this report. B. Advance Planning: submitted a checklist that identified several requirements. The checklist is attached to this report. C. Public Service/ New Century Energies: submitted a response to the checklist and it is attached to this report. D. PFA/Poudre Fire Authority: submitted a checklist that identified several requirements. The checklist is attached to this report. Building Inspection: submitted a checklist that identified several requirements. The checklist is attached to this report. Zoning: submitted the response that identified several requirements. Page 1 of 1 Mark McCallum - Harmony Centre Pad 5 -t comments doc Page 2 G. Forestry. submitted a checklist that identified several requirements. The checklist is attached to this report. H. Light and Power: submitted the response that identified several requirements. I. Water Conservation: submitted the response that identified several requirements. J. Post Office: submitted a response to the checklist and it is attached to this report. K. Stormwater Utility: submitted a response to the checklist and it is attached to this report. L. Cable TV: submitted a response to the checklist and it is attached to this report. M. Natural Resources: submitted the response that identified several requirements. N. Water/Wastewater: submitted a response to the checklist and it is attached to this report. O. Engineering/Pavement: submitted the response that identified several requirements. P. Engineering: submitted a checklist that identified several requirements. The checklist is attached to this report. Q. Current Planning Department: provides the following: 1. An amendment needs to be submitted and approved to Planning File #6-96 prior to approval of File #6-96M to accommodate any off -site alterations and changes that need to occur to accommodate this development as required by Land Use Code Article 2. 2. Delineate all property line setbacks, Harmony Road right-of-way width and improvements, private drive widths, and sidewalk widths on all plans as required by the City of Fort Collins Development Manual. 3. The plan sets need to include building envelope/footprint dimensions and distance to nearest property lines as required by the City of Fort Collins Development Manual. 4. Please label the sheet plan sets Sheet 1 of 5+, Sheet 2 of 5+, et cetera in the lower right hand corner of each applicable sheet, this allows the proposed development plan to be in sync with all other pad sites within the Harmony Centre Planned Unit Development. 5. The plan set needs to include reference to the Index of Drawings on the first plan sheet page. 6. The plan referenced as the Harmony Centre Area Plan (Sheet A1.01) needs be labeled as the Overall Site Plan, which would then be in sync with all other pad sites within the Harmony Centre Planned Unit Development and as required by the City of Fort Collins Development Manual. Page 2 of 1 Mark McCallum - Harmony Centre Pad 5 f',st comments.doc Page 3 7. All plans shall include the appropriate verifiable scale, including the Overall Site Plan. The overall site plan, site plan, and landscape plans shall utilize the same scale, as required by the City of Fort Collins Development Manual. 8. The north arrow shall be shown on all respective plans, i.e. Site Plan (Sheet A1.02) and Landscape Plan (Sheet L-1) as required by the City of Fort Collins Development Manual. 9. Existing and surrounding zoning shall be shown as required by the City of Fort Collins Development Manual. 10. The surrounding/abutting streets shall be labeled (Sheet L-1). 11. Site and Landscape Maintenance Agreements shall be submitted. 12. The following comments apply to the Site/Landscape Plan: a) Please note Section 3.2.1(D)(1)(c) as it relates to full tree stocking requirements, this section requires the addition of trees with tree grates within high use or high visibility sides of a structure. b) Per LUC Section 3.2. 1 (E)(4)(a) parking lot perimeter landscaping asks that trees be provided at a ratio of one (1) tree per twenty-five (25) lineal feet along a public street. Per LUC Section 3.2.1(D)(2) street trees shall be placed at thirty-foot to forty - foot spacing intervals in the center of all parkway areas (and be in accordance with Design and Construction Criteria, Standards and Specifications for Streets, Streetscapes, Sidewalks, Alleys and Other Public Ways). The trees shall be placed at least eight (8) feet away from the edges of driveways and alleys, and forty feet (shade trees)/fifteen feet (ornamental trees) (LUC 3.2.1(K) from any street light. C) After revising the site/landscape, please make sure the minimum species diversity is provided in accordance with Section 3.2.1(D)(3) of the Land Use Code. d) Please note LUC Section 3.2.1(E) (4) Parking Lot Perimeter Landscaping (b) addresses the need to screen parking areas. e) All parking lots need to meet the parameters addressed in LUC Section 3.2.1(E)(5)(a) — (e) including 3.2.2(13)(5)(a) walkways shall have one (1) canopy shade tree per forty (40) lineal feet of walkways planted in a landscape strip within five (5) feet of such walkway. f) It appears there may be a discrepancy with proposed vegetation adjacent to East Harmony Road with what was approved with the Harmony Centre PUD. Please note all existing and proposed trees and vegetation adjacent to the subject site to ensure compliance with Section 3.2.1(K) and all provisions of the Land Use Code (see attached landscape Harmony Centre PUD plans). g) Show planting plans in all landscape islands and strips. Page 3 of 1 Mark McCallum - Harmony Centre Pad 5 f;•st comments.doc Page 4 h) The site plan and landscape plan shall be in sync in the amount of public amenities. such as the location and number of bike racks. The screen wall needs to be extended as noted on the redline sheets. The screen wall is required by the Harmony Corridor Plan and shall be consistent with existing improvements. The landscape plan shall be revised to accommodate the wall. j) What does the crosshatched area refer to on the Site Plan (Sheet A1.02), please clarify and/or remove. Note that this will need to be removed from the final mylar. k) The parking plan shall be revised to meet Land Use Code Section 3.2. 13. The following comments apply to the architectural design of the building: a) You have not specified the opacity of the glass you are proposing. Section 3.5.1(F) of the LUC specifies that clear glass (reflectivity or opacity of less than 60%) shall be used for commercial storefront display windows and doors. Please specify. b) Please indicate all building colors (stone, bricks, stucco, et cetera with a color pallet) on the Building Elevations in accordance with Section 3.5.1(G) of the Land Use Code. c) The Harmony Corridor Plan requires that all architectural elements and detail features must be consistent or harmonious among multiple buildings. Section 3.5.3(D)(1) of the LUC specifies that in the case of multiple building developments, each individual building shall include predominant characteristics shared by all buildings in the development so that the development forms a cohesive place within the community. Similar architectural features should be carried over from the main building to the design of the smaller buildings, in particular the top and base treatments need to be more closely tied with the predominant characteristics of the overall Harmony Centre development. Section 3.5.3(D)(6) specifies that all facades shall have a recognizable "base," and "top" treatments. A "base" treatment consists of (but is not limited to): thicker walls, ledges or sills, integrally textured materials such as stone or other masonry, integrally colored and patterned materials such as smooth -finished stone or tile; lighter or darker colored materials, mullions or panels, or planters. A "top" treatment consists of (but is not limited to): cornice treatments, other than just colored "stripes" or "bands," with integrally textured materials such as stone or other masonry or differently colored materials, sloping roof with overhangs and brackets; stepped parapets. d) Section 3.5.1(J)(2) requires that any wall mounted utility meters and rooftop or ground mounted mechanical equipment shall allow the architectural design to be continuous. These functions must be screened from view from adjacent properties and public streets by materials that are not inferior to the principal materials of the building and landscape. Please specify where the utility meters and mechanical equipment will be located, and show proper screening measures. Rooftop mechanical must be hidden from view by a parapet. e) Indicate all building dimensions, including doors, windows, etcetera, on building Page 4 of 1 Mark McCallum - Harmony Centre Pad 5' -t comments doc Page 5 elevations. e) Section 3.5.3(D)(2) of the LUC specifies minimum wall articulation that must be achieved on all facades. The proposed design does not provide the proper architectural features to visually establish the required minimum 30-foot spaced bays. Architectural features such as columns, ribs or polasters, piers and fenestration pattern shall establish the bays The proposed design does not satisfy the requirement. See attached reclined plans. It appears that the proposed design is proposing inferior materials to the rest of the building on the west fapade. This section of the code prohibits use of inferior materials for side and rear facades, and specifies that all sides of the building shall include materials and design characteristics consistent with those on the front. The building material adjacent to the vault needs to be enhanced to comply with the Land Use Code, please consider faux windows, treillage, et cetera. c) Section 3.5.3(D)(3) specifies that facades that face a street or connecting walkway (all of the facades on this proposed building) must be subdivided and proportioned using features such as windows, entrances, arcades, arbors, awnings, treillage with vines, etc. along no less than 50% of the fapade. d) Scaled design elevations for the trash enclosure needs to be submitted in insure compliance with the Land Use Code. Section 3.5.1(J)(1) and (2) requires that no trash enclosure be located within twenty (20) feet of any public street, public sidewalk or internal pedestrian way and screened with vegetative landscaping. 14. The transformer location on the Site Plan (Sheet A1.02) and Landscape Plan (Sheet L- 1) are different. Show the actual location of all transformer(s) on the revised Site and Landscape Plans. They must be located no more than 10 feet from a paved surface and must be screened from view. 15. Please provide a detailed light plan (spec. sheet for all wall and pole mounted fixtures) insuring that all lighting apparatuses are shielded down, which meets the Section 3.2.4 including Section 3.2.2. Proposed lighting shall be compatible with Harmony Centre lighting. 16. Verification of the irrigation system connection points to ensure all landscaping is continuously maintained per Section 3.2.1 [J]. 17. All signs will require an additional sign permit outside this comment review. 18. All exterior mechanical devises, meters, et cetera, shall be screened. 19. Return all redlined documents with plan revisions, including redlined plans with Current Planning and Advance Planning comments. 20. The Stormwater Utility needs to have a Utility/Grading sheet. Coordinate Stormwater concerns with the Stormwater Utility Department, please contact Basil Hamdan at 970.221.6681. Page 5 of 1 Mark McCallum - Harmony Centre Pad 5 r -t comments doc Page 6 21. Coordinate the sidewalk system through out the development with Transportation Planning Services. 22. Coordinate the bus stop location adjacent to Harmony Road with GayLene Rossiter with Transfort at 970.224.6195. Additional comments and the required number of revised plans may be forthcoming as the various departments and reviewing agencies continue to review this request. Please provide a written response to each of the above comments with the submittal of plan revisions. And revised site/landscape development plans drawn to scale clearly dated and labeled shall be submitted to address the above. Section 2.2.11 of the Land Use Code requires that an applicant submit revisions based on this letter within 90 days or the project application becomes null and void. Your response to the City's concerns is due by March 21, 2000, A 30-day extension to this deadline is available. Request for an extension should be directed to the Current Planning Director. If remaining issues are those that do not require plan revisions, a status report verifying continuing efforts toward resolving the issues is required within the same timeline. The burden of demonstrating compliance with all Land Use Code criteria, The Harmony Corridor Plan, and the City of Fort Collins Development Manual is with the applicant. Please contact me at 970.221.6750 and/or e-mail: rfuchs(o)ci.fort-collins.co.us if you should have any questions or concerns related to these comments. Sincerely, Ronald G. Fuchs City Planner cc: City File #6-96M D-.\My Documents\Planning Document\Harmony Centre\Harmony Centre Pad 5 first comments.doc Page 6 of 1 PROJECT COMMENT SHEET City of Fort Collins Current Planning DATE: July 17, 1997 DEPT: Engineering. PROJECT: #6-96I Harmony Centre P.U.D. - Pad 6 Final (LDGS) PLANNER: Mike Ludwig All continents must be received no later than the staff review meeting: Wednesday, August 13, 1997 GENERAL COMMENTS AND CONCERNS: SEE PLAN SET FOR COMMENTS AND CONCERNS. Date: �+' "� Signature• CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS Plat Site _kW RqW _Utility Redline Utility Landscape _ Other PROJECT COMMENT SHEET City of Fort Collins DATE: 22 August, 1997 DEPT: Engineering PROJECT: 46-96C Harmony Centre P.U.D. - Final ENGINEER: Tim Blandford All comments must be received by: August 20, 1997 ®No Problems Problems or Concerns (see below or attached) LISTED BELOW ARE COMMENTS I FELT WERE THE "MAJOR" ISSUES THAT NEED TO BE ADDRESSED. PLEASE REFER TO THE UTILITY PLANS AND THE INDIVIDUAL SHEETS FOR ADDITIONAL COMMENTS AND CONCERNS. GENERAL COMMENTS: SHEET 3 OF 72: FINAL PLAT • THE PLAT NEEDS TO BE LABELED INDEPENDENTLY FROM THE UTILITY PLANS. • YOU WILL NEED A PEDESTRIAN ACCESS EASEMENT FOR THE PORTION OF THE SIDEWALK AT THE INTERSECTION OF JFK PARKWAY AND HARMONY ROAD THAT LIES OUTSIDE OF THE R.O.W. • MAKE SURE THAT ALL OF THE EASEMENTS HAVE BEEN LABELED. COMMENTS CONTINUED ON THE NEXT PAGE 9V Date: 817.219l Signature:_ PLEASF, SEND COPIES OF MARKED REVISIONS PLAT— SITE ® UTILITY ® LANDSCAPE COMMENTS CONTINUED FROM THE PREVIOUS PAGE... SHEET 6 OF 72: HORIZONTAL CONTROL PLAN WEST • MISSING THE CURVE INFORMATION FOR THE TEMPORARY TURN -AROUND. SHEET 7 OF 72: HORIZONTAL CONTROL PLAN CENTRAL • SEE SHEET No. 7 FOR COMMENTS. SHEET 1 7 OF 72: LARIMER DITCH NO 2 BOX CULVERT PLAN AND PROFILE • SEE SHEET NO. 1 7 FOR COMMENTS. SHEET 35 OF 72: HARMONY ROAD PLAN AND PROFILE SHEET I OF 4 • SEE SHEET NO. 35 FOR COMMENTS. SHEET 36 OF 72: HARMONY ROAD PLAN AND PROFILE SHEET 2 OF 4 • MODIFY THE HANDICAP RAMPS AND SIDEWALK AT THE DRIVEWAY ENTRANCE PER THE FAXES SENT TO YOUR OFFICE AND OUR DISCUSSIONS. • SEE SHEET NO. 36 FOR COMMENTS. SHEET 37 OF 72: HARMONY ROAD PLAN AND PROFILE SHEET 3 OF 4 • SEE SHEET NO. 37 FOR COMMENTS. SHEET 38 OF 72: HARMONY ROAD PLAN AND PROFILE SHEET 4 OF 4 • SEE SHEET NO. 38 FOR COMMENTS. SHEET 47 OF 72: COLLEGE AVENUE PLAN AND PROFILE • WE DO NOT WANT THE "SEAM" OF WHERE THE SAW CUTTING OCCURS TO BE IN THE TRAVEL PATH OF VEHICLES (I.E. THE TIRE PATH). • YOU WILL NEED A CONSTRUCTION EASEMENT FOR THE WORK BEING PERFORMED OUTSIDE OF THE R.O.W. • SEE SHEET NO. 47 FOR COMMENTS. SHEET 48 OF 72: COLLEGE AVENUE CROSS -SECTIONS (SHEET I OF 2) • SEE COMMENT ON THE PREVIOUS SHEET ABOUT THE LOCATION OF THE "SEAM" SHEET 49 OF 72: COLLEGE AVENUE CROSS -SECTIONS (SHEET 2 OF 2) • SEE PREVIOUS COMMENT ABOUT THE LOCATION OF THE "SEAM". COMMENTS CONTINUED ON THE NEXT PAGE CW COMMENTS CONTINUED FROM THE PREVIOUS PAGE... SHEET SO OF 72: JFK PARKWAY PLAN AND PROFILE SHEET I OF 3 • SEE SHEET NO. 50 FOR COMMENTS. SHEET S 1 OF 72: JFK PARKWAY PLAN AND PROFILE SHEET 2 OF 3 • SEE SHEET NO. 5 1 FOR COMMENTS. SHEET 52 OF 72: JFK PARKWAY PLAN AND PROFILE SHEET 3 OF 3 • VERTICAL CURVES ARE NEEDED WHERE GRADE CHANGES EXCEED 0.4% PER CITY STANDARDS. • SEE SHEET NO. 52 FOR ADDITIONAL COMMENTS. SHEET 58 OF 72: CITY OF FORT COLLINS CONSTRUCTION DETAILS • INCLUDE DETAIL NUMBER D-I8 IN THE PLAN SET (NOTE: ERASE "RESIDENTIAL STREET") SHEET 62 OF 72: CITY OF FORT COLLINS UTILITY DETAILS • SEE SHEET NO, 62 FOR COMMENTS. INDIVIDUAL SHEETS SUBMITTED SEPARATE FROM THE UTILITY PLANS: SHEET I OF 72: COVER SHEET • SEE SHEET NO. 1 FOR COMMENTS. SHEET 35 OF 72: HARMONY ROAD PLAN AND PROFILE SHEET I OF 4 • MATT BAKER WAS INFORMING ME THAT THERE 15 A N ELECTRIC VAULT BURIED AT THE INTERSECTION OF HARMONY ROAD AND COLLEGE AVENUE (SEE SHEET NUMBER 35 OF 72 FOR APPROXIMATE LOCATION). YOU WILL NEED TO LOCATE THIS AND INCLUDE IT ON THE PLANS. WE NEED TO BE SURE THAT THIS WILL NOT BE DISTURBED DURING CONSTRUCTION_ IF THIS VAULT NEEDS TO BE RELOCATED, IT WILL BE AT THE DEVELOPERS EXPENSE. PLEASE MAKE NOTE OF THAT ON THE PLANS. • MATT BAKER WOULD ALSO LIKE THE MEDIAN ALONG HARMONY ROAD TO BE EXPOSED AGGREGATE INSTEAD OF BRICK, PLEASE MAKE THE APPROPRIATE CORRECTIONS. • PLEASE RELOCATE THE "SEAM" OF WHERE THE NEW ASPHALT WILL MATCH THE EXISTING ASPHALT. WE DO NOT WANT IT TO ALIGN WITH A VEHICLE'S TIRES, I WOULD SUGGEST MOVING IT MORE TOWARDS THE MIDDLE OF THE TRAVEL LANE. • SEE SHEET NO. 35 FOR ADDITIONAL COMMENTS. COMMENTS CONTINUED ON THE NEXT PAGE EV COMMENTS CONTINUED FROM THE PREVIOUS PAGE... SHEET 36 OF 72: HARMONY ROAD PLAN AND PROFILE SHEET 2 OF 4 • MODIFY THE SIDEWALKS AND HANDICAP RAMPS PER OUR CONVERSATIONS AND THE FAX SENT TO YOUR OFFICE. • SEE SHEET NO. 36 FOR ADDITIONAL COMMENTS. SHEET 37 OF 72: HARMONY ROAD PLAN AND PROFILE SHEET 3 OF 4 • SEE SHEET NO. 37 FOR COMMENTS. SHEET 38 OF 72: HARMONY ROAD PLAN AND PROFILE SHEET 4 OF 4 • SEE SHEET NO. 36 FOR COMMENTS. SHEET SO OF 72: JFK PARKWAY PLAN AND PROFILE SHEET I OF 3 • SEE SHEET NO, 50 FOR COMMENTS, SHEET S I OF 72: JFK PARKWAY PLAN AND PROFILE SHEET 2 OF 3 • SEE SHEET NO. S I FOR COMMENTS. SHEET 63 OF 72: COLLEGE ,AVENUE/HARMONY ROAD INTERSECTION PLAN • MOVE STOP BAR SO THAT IT IS 4' FROM THE CROSSWALK. • IT APPEARS AS THOUGH YOU CAN PULL THE MEDIAN UP APPROXIMATELY 1 2 TO 1 3 FEET AND STILL GET THE PROPER TURN MOVEMENTS FOR A WB-50 TRUCK WITH A 60' RADIUS. MAKE THE APPROPRIATE ADJUSTMENTS. • SEE SHEET No. 63 FOR ADDITIONAL COMMENTS. SHEET 64 OF 72: JFK PARKWAY-HOGAN DRIVE/HARMONY ROAD INTERSECTION PLAN • SEE SHEET NO. 64 FOR COMMENTS. PROJECT COMMENT SHEET City of Fort Collins Current DATE: 8 Judy, 1997 DEPT: Engineering PROJECT: #6-96C Harmony Centre P.U.D. - Final PLANNER: Mike Ludwig ENGINEER: Tim Blandford All comments must be received by: 7/9/97 No Problems Problems or Concerns (see below or attached) LISTED BELOW ARE COMMENTS I FELT WERE THE "MAJOR" ISSUES THAT NEED TO BE ADDRESSED. PLEASE REFER TO THE UTILITY PLANS AND THE INDIVIDUAL SHEETS FOR ADDITIONAL COMMENTS AND CONCERNS. GENERAL COMMENTS: SHEET 3 OF GG: FINAL PLAT • IF PAVILION I-ANE IS GOING TO BE REALIGNED, THE FINAL PLAT NEEDS TO REFLECT THE CHANGES INCLUDING THE REALIGNMENT OF THE R.O.W. OTHER SHEETS SHOWING THE TEMPORARY TURNAROUND WILL NEED TO BE MODIFIED. REFER TO THE UTILITY PLANS FOR THESE SHEETS. • MAKE SURE THAT ALL OF THE EASEMENTS HAVE BEEN LABELED. COMMENTS CONTINUED ON THE NEXT PAGE 9W -F Date: 8 dut-y , 19`n Signature: PLEASE SEND COPIES OF MARKED REVISIONS: PLAT SITE UTILITY LANDSCAPE COMMENTS CONTINUED FROM THE PREVIOUS PAGE... SHEET 8 OF 66: HORIZONTAL CONTROL PLAN • REFER TO SHEET NUMBER 64 OF 66 FOR COMMENTS ON THE INTERSECTION OF JFK PARKWAY AND HARMONY ROAD. SHEET 35 OF 66: HARMONY ROAD PLAN AND PROFILE SHEET I OF 4 • ACCORDING -TO CDOT STANDARDS, THE RIGHT TURN LANE ON HARMONY ROAD AT COLLEGE AVENUE, NEEDS TO BE 1 2' EXCLUSIVE OF THE GUTTER PAN. PLEASE MAKE THE APPROPRIATE: MODIFICATIONS. • ACCORDING TO CDOT STANDARDS, THE CURB RETURN RADIUS AT THE ENTRANCE TO THE GAS STATION NEEDS TO BE A MINIMUM OF 20'. • PLEASE PROVIDE A TYPICAL CROSS-SECTION OF HARMONY ROAD WHERE INDICATED ON SHEET NUMBER 35. • THE RADII OF THE MEDIAN TAPERS AND TRANSITIONS NEED TO BE 80' INSTEAD OF 40'. • THE CONCRETE PAN BEING PROPOSED AT THE ENTRANCE TO THE GAS STATION DOES NOT MEET OUR STANDARDS. THE MINIMUM SLOPE OF THE PAN FLOWLINE NEEDS TO BE A MINIMUM OF 0.60%. PLEASE MODIFY. • THERE ARE SOME BOGUS ELEVATIONS ALONG THE MEDIAN AT AROUND STATION 1 2+75.00. PLEASE CORRECT. SHEET 36 OF 66: HARMONY ROAD PLAN AND PROFILE SHEET 2 OF 4 • ACCORDING -TO CDOT STANDARDS, THE RIGHT TURN LANE ON HARMONY ROAD, NEEDS TO BE 1 2' EXCLUSIVE OF THE GUTTER PAN. PLEASE MAKE THE APPROPRIATE MODIFICATIONS. • THE CONCRETE PAN BEING PROPOSED AT THE ENTRANCE TO THE DEVELOPMENT DOES NOT MEET OUR STANDARDS. THE MINIMUM SLOPE OF THE PAN FLOWLINE NEEDS TO BE A MINIMUM OF 0.60%. PLEASE MODIFY. • THE RADII OF THE MEDIAN TAPERS AND TRANSITIONS NEED TO BE 80' INSTEAD OF 40'. • THE NOSE OF THE MEDIAN NEEDS TO BE A MINIMUM OF 20' FROM THE FLOWLINE FROM AN INTERSECTING STREET PER CITY OF FORT COLLINS STREET STANDARDS. • YOU NEED TO CONCRETE PAVE INTERSECTIONS TO THE R.O.W. LINE PER CITY OF FORT COLLINS STANDARDS. SHEET 37 OF 66: HARMONY ROAD PLAN AND PROFILE SHEET 3 OF 4 • THE RADII OF THE MEDIAN TAPERS AND TRANSITIONS NEED TO BE 80' INSTEAD OF 40'. • YOU NEED TO CONCRETE PAVE INTERSECTIONS TO THE R.O.W. LINE PER CITY OF FORT COLLINS STANDARDS. • ACCORDING TO CDOT STANDARDS, THE RIGHT TURN LANE ON HARMONY ROAD, NEEDS TO BE 1 2' EXCLUSIVE OF THE GUTTER PAN. PLEASE MAKE THE APPROPRIATE MODIFICATIONS. • SEE SHEET NUMBER 64 FOR COMMENTS ON THE INTERSECTION OF HARMONY ROAD AND JFK PARKWAY. COMMENTS CONTINUED ON THE NEXT PAGE cW COMMENTS CONTINUED FROM THE PREVIOUS PAGE... SHEET 38 OF 66: HARMONY ROAD PLAN AND PROFILE SHEET 4 OF 4 • ACCORDING TO CDOT STANDARDS, THE RIGHT TURN LANE ON HARMONY ROAD, NEEDS TO BE 1 2' EXCLUSIVE OF THE GUTTER PAN. PLEASE MAKE THE APPROPRIATE MODIFICATIONS. • SEE SHEET NUMBER 64 FOR COMMENTS ON THE INTERSECTION OF HARMONY ROAD AND JFK PARKWAY. SHEET 40 OF 66: HARMONY ROAD CROSS -SECTIONS SHEET 2 OF 8 • FOR THE CROSS-SECTION AT STATION 1 2+50.00, THE S% SLOPE SEEMS TO BE QUITE DRASTIC, YCU MAY WANT TO TALK WITH THE PROPERTY OWNER ABOUT THIS. IS THIS GOING TO AFFECT SEMI -TRUCKS ENTERING AND EXITING THE SITE. YOU MAY WANT TO EXTEND THE _.IMIT OF WORK IN THIS AREA SO THAT THE SLOPE COULD BE FLATTENED OUT. SHEET 47 OF 66: COLLEGE AVENUE PLAN AND PROFILE • CHECK WITH THE STORMWATER DEPARTMENT AND CDOT TO SEE IF IT IS ALRIGHT TO HAVE WATER DRAINING ONTO COLLEGE AVENUE. • HOW WILL THE WATER DRAIN OFF OF COLLEGE AT THE BEGINNING OF THE DECEL. LANE? WILL THERE BE A SIDEWALK CHASE OR INLET? PLEASE INDICATE AND MODIFY THE APPROPRIATE. SHEETS. • THE NOSE OF THE MEDIAN NEEDS TO BE A MINIMUM OF 20' FROM THE FLOWLINE FROM AN INTERSECTING STREET PER CITY OF FOR- COLLINS STREET STANDARDS. SHEET 50 OF 66: JFK PARKWAY PLAN AND PROFILE SHEET I OF 3 • THE NOSE OF THE MEDIAN NEEDS TO BE A MINIMUM OF 20' FROM THE FLOWLINE FROM AN INTERSECTING STREET PER CITY OF FOR- COLLINS STREET STANDARDS. • THE CURB RETURN RADII OFF OF JFK PARKWAY NEED TO BE 25' MINIMUM. SHEET 5 1 OF 66: JFK PARKWAY PLAN AND PROFILE SHEET 2 OF 3 • YOU NEED TO CONCRETE PAVE INTERSECTIONS TO THE R.O.W. LINE PER CITY OF FORT COLLINS STANDARDS. • THE NOSE OF THE MEDIAN NEEDS TO BE A MINIMUM OF 20' FROM THE FLOWLINE FROM AN INTERSECTING STREET PER CITY OF FOR- COLLINS STREET STANDARDS. • THE CURB RETURN RADII OFF OF JFK PARKWAY NEED TO BE 25' MINIMUM. • THE CONCRETE PAN BEING PROPOSED AT THE ENTRANCE TO THE DEVELOPMENT DOES NOT MEET OUR STANDARDS. THE MINIMUM SLOPE OF THE PAN FLOWLINE NEEDS TO BE ,4 MINIMUM OF 0.60%. PLEASE MODIFY. SHEET 64 OF 66: JFK PARKWAY - HOGAN DRIVE/ HARMONY ROAD INTERSECTION PLAN • STRAIGHTEN CROSSWALKS OUT AS SHOWN. (PER KATHLEEN REAVIS - TRANSITION PLANNING) COMMENTS CONTINUED ON THE NEXT PAGE OW COMMENTS CONTINUED FROM THE PREVIOUS PAGE... • COMMENTS ON SHEETS 37 AND 38 APPLY TO THIS SHEET AS WELL. • AGAIN, THE: COMMENTS PRESENTED ABOVE ARE THE "MAJOR" COMMENTS FOUND ON THE RESPECTIVE SHEETS. REFER TO THE PLAN SET FOR ADDITIONAL COMMENTS AND CONCERNS. PROJECT COMMENT SHEET City of Fort Collins Current Planning DATE: February 25, 1997 DEPT: Engineering PROJECT: #6-96C Harmony Centre PUD - Final PLANNER: Mike Ludwig All comments must be received by: Monday, March 17, 1997 GENERAL COMMENTS: Sheet 1 of 51 • The soils report/pavement design needs to be referenced. • Include a graphic scale. • Distinguish the storm sewer, sanitary sewer, and water lines with different line types. Sheet 2 of 51 • Just a few minor changes to the general notes. Sheet 3 of 51 • Provide a vicinity map and include the different zoning districts, streets, major public facilities, and city limits. • Modify the description in the dedication. • Add street name to JFK Parkway. Date: Signature_` CHECK IF YOU WISH TO RECEIVE 0 PLAT COPIES Oh REVISIONS El SITE 0 LANDSCAPE ED UTILITY Sheet 4 of 51 Add % slope to the new sections of Harmony Road. (min. 2%) For the outfall curb and gutter and the in -fall curb and gutter, use details conforming to the City of Fort Collins standards. What are you planning to do with the runoff water on the south side of the median? You will not be allowed to drain the water across Harmony Road through the concrete chases. Concentrated amounts of water will cause deterioration in the pavement. Sheet 5 of 51 :IFK Parkway is an arterial street, .. you need to meet the street standards for the parkway and the sidewalk. Sheet 6 of 51 Include the scale of this drawing on the sheet. Identify the property lines more clearly. Sheet 7 of 51 Include the scale of this drawing on the sheet. Move "JFK Parkway" so it's more clearly read. Identify the property lines more clearly. Sheet S of 51 Identify the property lines more clearly. Include the scale of this drawing on the sheet. Move "Hogan Road" so it's more clearly read. Sheet 9 of 51 • Rotate "East Harmony Road" to read the other direction. • Delete the bearing and distance information along the boundary lines. This isn't necessary on this drawing. • A few of the spot elevations aren't readable. Please make clear. • Make sure that all contours match up with existing contours offsite. • Include a legend identifying all symbols used. • Identify the property lines. i.e. "Property Line" comments continued on next page — Commu_..ty Planning and Environmental--,rvices Current Planning City of Fort Collins August 20, 1997 Terry Rucker SEM Architects 7935 E. Prentice Avenue, #102 Englewood, CO 80111 Dear Terry: Staff has reviewed your plans for the Harmony Centre Pad Site 1 Final PUD that were submitted on July 16, 1997 and would like to offer the following comments: 1. The Traffic Operations Department stated that the decel lane will need to be constructed on South College Avenue with the Harmony Centre First Filing. 2. The Water Conservation Specialist stated that the landscape plan must contain a note calling for the review and approval by the City of Fort Collins of any landscape irrigation system, prior to the issuance of a Building Permit. 3. The Advance Planning Department offers the following comments: a. There was no indication on the plans showing the location of any mechanical equipment. Please show how this equipment will be fully incorporated into the building's architecture. b. The sidewalk on the north side of Pad 1 is marginal as a pedestrian environment. The sidewalk on the east side of the drive-thru lanes is too narrow for walking and marginal for trees to be planted. Each of these walks and the walk on the west side of the building should be six to seven feet wide with a minimum 5.5 foot wide planting strip for foundation plantings and trees. 4. The Zoning Department offers the following comments: a. One additional handicap stall is required as we will count spaces surrounding the pad but not within the pad site. Approximately 66 spaces will be counted for Pad Site 1 which requires a total of 3 handicapped parking spaces. b. Please dimension the distances of the building from the lot lines. C. Please dimension the overall building height on the building elevations. d. Please indicate the proposed/permitted land use(s) for the building within the building envelope on Sheets 2 and 3. I North College Avenue • P.O. Boy 7�80 • for; Collins, CO t;0522-0 '-ta `1 1 . FAX (97()) 1-o,78 • TDD (970) • The areas showing the parking lot detention are a little dark. Please lighten up so the information is more readable. • Indicate where the spot elevations are with an "x". Refer to sheets 10 and 11. • The contours are hard to distinguish between the other lines on the drawing. Please change the line widths or darkness to make it less confusing to read. • Include the scale of this drawing on the sheet. Sheet 10 of 51 • Delete the bearing and distance information along the boundary lines. This isn't necessary on this drawing. • A few of the spot elevations aren't readable. Please make clear. • Make sure that all contours match up with existing contours offsite. • Include a legend identifying all symbols used. • Identify the property lines. i.e. "Property Line" • The contours are hard to distinguish between the other lines on the drawing. Please change the line widths or darkness to make it less confusing to read. • Include the scale of this drawing on the sheet. Sheet 11 of 51 • Delete the bearing and distance information along the boundary lines. This isn't necessary on this drawing. • A few of the spot elevations aren't readable. Please make clear. • Make sure that all contours match up with existing contours offsite. • Include a legend identifying all symbols used. • Identify the property lines. i.e. "Property Line" • The contours are hard to distinguish between the other lines on the drawing. Please change the line widths or darkness to make it less confusing to read. • Include the scale of this drawing on the sheet. • Move "Hogan Road" and "JFK Parkway" over so they are more readable. Sheet 12 of 51 • Delete the bearing and distance information along the boundary lines. This isn't necessary on this drawing. • Rotate "East Harmony Road" to read the other direction. • Include a legend identifying all symbols used. • Identify the property lines. i.e. "Property Line" • You will need to provide a ROW dedication from the Pavilion Shopping Center. comments continued on next page Sheet 13 of 51 • Delete the bearing and distance information along the boundary lines. This isn't necessary on this drawing. • Include a legend identifying all symbols used. • Identify the property lines. i.e. "Property Line" • Include the scale of this drawing on the sheet. • Please show the existing property to the north of the site. Sheet 14 of 51 • Delete the bearing and distance information along the boundary lines. This isn't necessary on this drawing. • Include a legend identifying all symbols used. • Identify the property lines. i.e. "Property Line" • Include the scale of this drawing on the sheet. • Please show the existing property to the north of the site and to the south of Harmony Road. • Rotate "East Harmony Road" to read the other direction. • Missing some water valves where indicated. Sheet 15 of 51 • Delete the bearing and distance information along the boundary lines. This isn't necessary on this drawing. • Include a legend identifying all symbols used. • Identify the property lines. i.e. "Property Line" • Include a graphic scale on the sheet. • Please show the existing property to the north of the site and to the south of Harmony Road. • Missing some invert elevations for the box culvert profile. • Show the location of the access grates with stationing on the profile. • Show all water line, sanitary sewer, etc. crossings. Include the clearance depths, invert elevations, etc. • Reference all details used. Sheet 16 of 51 Coordinate with the ditch company on the adequacy of the inlet grate. comments continued on next page Sheet 17 of 51 • Show all water line, sanitary sewer, etc. crossings. Include the clearance depths, invert elevations, ere. • Delete the bearing and distance information along the boundary lines. This isn't necessary on this drawing. • Include a legend identifying all symbols used. • Identify the property lines. i.e. "Property Line" • Include the scale of this drawing on the sheet. • Show all easements and label. • Show directions and distances on storm sewer segments. Sheet 18 of 51 • Show all water line, sanitary sewer, etc. crossings. Include the clearance depths, invert elevations, etc. • Delete the bearing and distance information along the boundary lines. This isn't necessary on this drawing. • Include a legend identifying all symbols used. • Identify the property lines. i_e. "Property Line" • Include a graphic scale on both plan views. • Show all easements and label. • Show directions and distances on storm sewer segments. • The stationing of the manholes don't seem to match with what is shown on the plan views. Please clarify. Sheet 19 of 51 • Show all water line, sanitary sewer, etc. crossings. Include the clearance depths, invert elevations, etc. • Delete the bearing and distance information along the boundary lines. This isn't necessary on this drawing. • Include a legend identifying all symbols used. • Identify the property lines. i.e. "Property Line" • Include a graphic scale on plan view. • Show all easements and label. • Show directions and distances on storm sewer segments. • Missing a manhole or inlet on the plan and profile. • Show existing information to the north of the site. comments continued on next page — Sheet 20 of 51 • Show all water line, sanitary sewer, etc. crossings. Include the clearance depths, invert elevations, etc. • Delete the bearing and distance information along the boundary lines. This isn't necessary on this drawing. • Include a legend identifying all symbols used. • Identify the property lines. i.e. "Property Line" • Include a graphic scale on plan view. • Show all easements and label. • Show directions and distances on storm sewer segments. • Need to add another manhole. Max. spacing for an 18"o pipe is 400'. • Show existing information to the north of the site. • Missing a few invert elevations. Sheet 21 of 51 • Show all water line, sanitary sewer, etc. crossings. Include the clearance depths, invert elevations, etc. • Include a legend identifying all symbols used. • Identify the property lines_ i.e. "Property Line" • Include a graphic scale on plan view. • Show all easements and label. • Show directions and distances on storm sewer segments. Sheet 22 of 51 • Include a legend identifying all symbols used. • Identify the property lines. i.e. "Property Line" • Include a graphic scale on plan views. • Show all easements and label. • Show directions and distances on storm sewer segments. • Provide north arrows. • You will need to provide a lot more information in order for us to make any significant comments. Sheet 23 of 51 • Include a legend identifying all symbols used. • Identify the property lines. i.e. "Property Line" • Include a graphic scale on plan views. • Show all easements and label. • Show directions and distances on sanitary sewer segments. comments continued on next page - • Need a manhole added to the profile. • Make sure you have a 0.2' drop at all manholes. • Show all water line, sanitary sewer, etc. crossings. Include the clearance depths, invert elevations, etc. Sheet 24 of 51 • Include a legend identifying all symbols used. • Include a graphic scale on plan views. • Show all easements and label. • Show directions and distances on sanitary sewer segments. • Show all water line, sanitary sewer, etc. crossings. Include the clearance depths, invert elevations, etc. Sheet 25 of 51 • Include a legend identifying all symbols used. • Include a graphic scale on plan views. • Show all easements and label. • Show directions and distances on sanitary sewer segments. • Show all water line, sanitary sewer, etc. crossings. Include the clearance depths, invert elevations, etc. Sheet 26 of 51 • Include a legend identifying all symbols used. • Include a graphic scale on plan views. • Show all easements and label. • Show directions and distances on sanitary sewer segments. • Show all water line, sanitary sewer, etc. crossings. Include the clearance depths, invert elevations, etc. • Provide a north arrow. Sheet 27 of 51 • Include a legend identifying all symbols used. • Show all easements and label. • Show all water line, sanitary sewer, etc. crossings. Include the clearance depths, invert elevations, etc. • Provide more information pertaining to the plan and profile drawings. These drawings are too vague to comment on. comments continued on next page -- Sheet 28 of 51 • Refer to page number 28 in the utility plans for comments. Sheet 29 of 51 • The sidewalk on the north side of Harmony Road needs to be along the property line. Mortify other sheets and cross -sections. • Refer to page number 29 in the utility plans for additional comments. Sheet 30 of 51 • Do you need to have all of the vertical curves shown? Could you get by having just grade breaks'? • Refer to page number 30 in the utility plans for additional comments. Sheet 31 of 51 • Refer to page number 30 in the utility plans for additional comments. Sheets 32 thru 38 of 51 • What are you planning to do with the runoff water on the south side and north sides of the median where the crown of the road is offset from the medians? You will not be allowed to drain the water across Harmony Road through the concrete chases. Concentrated amounts of water will cause deterioration in the pavement. Also, in these areas, water will tend to collect and become stagnant. This is not acceptable. • Referring to the cross-section at station 15+50.00 on page number 34: label all other cross -sections in this manner. Sheet 39 of 51 • Include a legend identifying all symbols used. • Identify the property lines. i.e. "Property Line" • Include a graphic scale on plan views. • Show all easements and label. • Need a vertical curve at station 14+78.61 because the grade change is too great. Either that or increase the percent grade in the profile. • Provide a profile ofthe east side of the median. We need to know the cross slopes, etc. Sheets 40 thru 41 of 51 comments continued on next page -- The cross -sections look like a template. Are these accurate? Provide cross -slopes, elevations, etc. as well as the existing median, to complete the cross -sections. Cannot have a situation like what is shown in the cross-section on sheet number 40. This applies to all cross -sections. Some of the cross -sections were not included in the plan set. Sheets 42 thru 44 of 51 • Show all water line, sanitary sewer, etc. crossings. Include the clearance depths, invert elevations, etc. • Include a legend identifying all symbols used. • Identify the property lines. i.e. "Property, Line" • Show all easements and label. • Show directions and distances on storm sewer segments. • Separate all profiles including the profile for the storm sewer. • Include the scale of the drawing on the plan view. • The dimensions of the transit stop do not meet the standard requirements. • Complete these drawings and I will review at a later time. • See sheets for additional comments. Sheets 42 thru 44 of 51 Are all details referenced in the previous drawings? If not, please reference all details used in this set of plans. We would like you to add a couple of sheets to the plan set. 1. The entire intersection of College Avenue and Harmony Road 2. The intersection of JFK anf Hogan This will provide us with more information on how the lanes interact with each other. * As a comment that pertains to the entire set of utility plans, there were a lot of lines, symbols, casements, etc. that were not labeled. To simplify matters, not only from an engineering standpoint, but probably from a contractor's standpoint, these items should be identified and labeled to clarify and simplify the review process. PROJECT COMMENT SHEET City of Fort Collins Current Planning w� DATE: February 25, 1997 DEPT: Eng Pvmnt PROJECT: #6-96C Harmony Centre PUD - Final PLANNER: Mike Ludwig All comments must be received by: Monday, March 17, 1997 A final Soils report and pavement design will need to be submitted after underground work is completed and streets are rough cut. Date: 3 _ 0 - 9 7 Signature =7 L'IC"fF TOM W771 10 EIVE COPIES OF REVISIONS ❑ SITE ❑ LANDSCAPE ❑ UTILITY DATE: May 8, 1997 DEPT: Engineering PROJECT: PLANNER: Mike Ludwig GENERAL COMMENTS: Sheet 1 of 64: Cover Sheet • Does the bench mark reference the `Black Bolt Survey" book? Make sure that it does. • Make sure that all of the references to the sheets for storm sewer and sanitary sewer profiles, etc. are correct. Sheet 2 of 64: Legend, Abbreviations, and Notes • Please add the erosion control construction sequence. Sheet 3 of 64: Final Plat • Include "Final Plat of..." in the title. • Number this sheet independently from the other sheets in the plan set. Sheet 5 of 64: College Avenue and JFK Parkway - Typical Sections • Check the dimensioning on the cross section for College Avenue. The dimensions don't seem to add up and don't match what is shown on the plan and profile sheet for College Avenue (sheet no. 47 of 64). Sheet 12 of 64: Grading Plan - North • We want to see a written agreement from West property stating that he is agreeing to hear the full cost of construction for the cul-de-sac on Stover Street in the future. Comments continued on the next page t' Comments continued from the previous page... The R.O.W. needs to be dedicated for the cul-de-sac on Stover Street per the old street standards. You will need to obtain a construction easement from the neighboring properties because of the offsite grading. Sheet 17 of 64: Larimer Ditch No. 2, Box Culvert - Plan and Profile Show all utility crossings with inverts and clearances. Show the location of the access grate on the profile. Sheet 19 of 64: Storm Sewer "A" - Plan and Profile May want to consider labeling or numbering the manholes, the storm sewer manholes as well as the sanitary sewer manholes, so it will be easier to reference them. This comment is typical for all storm sewer and sanitary sewer plan and profile sheets. Are you proposing any type of head wall and erosion control measures? Please show on the plans. Sheet 20 of 64: Storm Sewer "B" - Plan and Profile Show all utility crossings and provide inverts, clearances, stationing, etc. Are you proposing any type of head wall and erosion control measures? Please show on the plans. Sheet 22 of 64: Storm Sewer "D" - Plan and Profile Are you proposing any type of head wall and erosion control measures? Please show on the plans. Sheet 23 of 64: Storm Sewer "E" and "F" - Plan and Profile Show all utility crossings and provide inverts, clearances, stationing, etc. Sheet 24 of 64: Storm Sewer "G" - Plan and Profile Show all utility crossings and provide inverts, clearances, stationing, etc. Sheet 28 of 64: Storm Sewer "K" and "L" - Plan and Profile Show all utility crossings and provide inverts, clearances, stationing, etc. Missing inlet K1. Please modify the plans. Comments continued on the next page w 5. The Building Inspection Department offers the following comments: a. Please clearly show the property lines and proximity of property lines to the proposed building on the site plans submitted with the application for building permit. b. The site shall be accessible to persons with disabilities in accordance with Uniform Building Code Section 3103 and UBC Appendix Section 3106. A designated and marked "accessible route of travel' among all the buildings on the site and building exits and entrances and the public way (public sidewalk) is shown. Accessible routes shall comply with ANSI A117.1-1992 with running slopes no greater than 1:20 and cross slopes no steeper than 1:50. Where routes cross lanes for vehicle traffic, they shall be designated and marked as a cross walk. Provide parking and signs per Appendix Section 3107. Parking and access aisles shall comply with ANSI A117.1-1992 with slopes no greater than 1:50 in any direction. C. Buildings shall be designed to comply with the Fort Collins Nonresidential Energy Code (ASHRAE 90.1 with local amendments) or residential energy code (MEC 1995 with local amendments) whichever is applicable. d. Section 504 of the 1991 edition of the Uniform Building Code as adopted by the City of Fort Collins requires that exterior walls of building 1 located closer within distances, based on use and construction type, to a property line be of fire -resistive construction. Openings are restricted or prohibited in such exterior walls. A parapet extending 30-inches above the roof surface may be required by UBC Section 1710. Projections, such as cornices, eave overhangs or exterior balconies shall not extend over the property line and must comply with UBC Sections 1710 and 504. 6. The Transportation Planning Department offers the following comments: a. Please provide an enhanced pedestrian crossing with stamped, colored concrete across the access drive north of the monument sign located on College Avenue. b. Please provide a sidewalk connection and pedestrian crossing from the sidewalk on the south side of the Kensington entrance, south to the northwest corner of Pad 1. C. Please provide a sidewalk connection and enhanced crossings on the south side of Pad 1 from College Avenue to the east side of the drive thru lanes. 7. The Fort Collins -Loveland Water District and the South Fort Collins Sanitation District have reviewed the above mentioned submittal and have no objections provided all District requirements are satisfied. Comments continued from the previous page... Sheet 29 of 64: JFK Culvert - Plan and Profile Show all utility crossings and provide inverts, clearances, stationing, etc. Sheet 35 of 64: Harmony Road Plan and Profile - Sheet 1 of 4 • Show the boa: culvert crossing. • Need to provide curb return profiles for all curb returns. • You are showing a 2' raised median on Harmony. This needs to be a 4' raised median. Please modify the plans. • Show the handicap ramps at the College,/Harmony intersection. Make sure that this sheet shows the same information that is shown on sheet no. 63 of 64, i.e. curb and gutter, ramps, etc. • You will need to eliminate the angle points in the medians and provide radii per the street standards. • Check with the transportation department regarding the striping for the turning lane on Harmony. Sheet 36 of 64: Harmony Road Plan and Profile - Sheet 2 of 4 • You will need to eliminate the angle points in the medians and provide radii per the street standards. • Check with the transportation department regarding the striping for the turning lane on Harmony. • Modify the left turn median. It doesn't need to be as wide as is shown. Accommodate for semi trucks turning into the site. • Please provide us with more cross sections in the area where the left turn lane and median is. Need a better idea of where the crown of the road is and how the water will end up draining. • The sidewalk on the north side of Harmony needs to be flush with the property line. Sheet 37 of 64: Harmony Road Plan and Profile - Sheet 3 of 4 You will need to eliminate the angle points in the medians and provide radii per the street standards. Sheet 37 of 64: Harmony Road Plan and Profile - Sheet 4 of 4 You will need to eliminate the angle points in the medians and provide radii per the street standards. Need to provide curb return profiles for all curb returns. Comments continued on the next page w Comments continued from the previous page... Check with the transportation department regarding the striping for the turning lane on Harmony - Make sure that the intersection of JFK and Harmony is the same on all of the sheets. Right now the water appears to be draining onto Harmony, which is not acceptable. However what is shown is different than what is provided on sheet number 50 of 64. Please modify. Sheet 38 of 64: Harmony Road Cross Sections - Sheets 1 thru 8 of 8 The minimum cross section slope is 2%. Please modify all of the cross sections that do not meet this standard. Make sure that there are no "pockets" where water can end up being trapped. The maximum cross sectional slope is 4% per the street standards. There are a few street cross sections that do not meet this standard. Pleas modify. Sheet 47 of 64: College Avenue - Plan and Profile • Provide the design for the modified decel lane that was discussed. Make sure that vehicles will not be able to enter the decel lane directly from the gas station. Driveways must exit onto College Avenue and not onto the decel lane. • Show all curb return profiles. • Just show the information that relates to the street design except for any utility crossings that could be potential problems during construction. Also label everything so it is clear what is being presented. • Distinguish more clearly what is being proposed, what is existing, what is being removed, etc. • Are there any power poles, or other structures that will be relocated during the construction? Please indicate. Sheet 48 of 64: College Avenue Cross Sections - Sheet 1 and 2 of 2 You need to match the existing slope or make the slope of the proposed asphalt section greater. We will not allow the situation being shown to be constructed. Please shoe the existing median on College Avenue. Sheet 50 of 64: ,IFK Parkway Plan and Profile - Sheet 1 of 3 The JFK/Harmony intersection doesn't match what is shown on sheet number 37 of 64. Please make the appropriate corrections. Provide cross sections of JFK Parkway every 50'. The text in the profiles is too small. Please make larger. Comments continued on the next page aw Comments continued from the previous page... Show all curve information in a table. This includes the curb returns. Provide profiles for all of the curb returns. Show the concrete pan in the profile. Sheet 51 of 64: JFK Parkway Plan and Profile - Sheet 2 of 3 • Provide cross sections of JFK Parkway every 50'. • The text in the profiles is too small. Please make larger. • Show all curve information in a table. This includes the curb returns. • Provide profiles for all of the curb returns. • Show the concrete pan in the profile. • The nose of the medians need to be a minimum of 20' from the flowline of the intersecting street. Please modify. Sheet 52 of 64: JFK Parkway Plan and Profile - Sheet 3 of 3 Provide cross sections of JFK Parkway every 50'. The text in the profiles is too small. Please make larger. Show all curve information in a table. This includes the curb returns. Sheet 63 of 64: College Avenue/Harmony Road Intersection Plan • The northeast comer of the intersection looks different from what was previously shown on sheet number 35 of 64. Please make the appropriate corrections. • Show all of the curb and gutters, existing and proposed. Don't just show them as single lines. • Widen the eastbound lane on Harmony (the lane just south of the median) to 14' or pull the nose of the median back. Right now it conflicts with trucks turning from southbound College onto Harmony. • You may want to taper the southem-most lane, as shown on the plans, to make room for wider turns from southbound College to eastbound Harmony. Sheet 64 of 64: JFK Parkway/Harmony Road Intersection Plan Provide more detail, i.e. curb and gutter, labeling, etc. Make sure that this sheet matches the information provided on sheet number 50 of 64 and sheet number 37 of 64. Provide all of the necessary information that was discussed at our meeting with regards to the intersection improvements. ADDITIONAL INFORMATION: Comments continued on the next page sw Comments continued from the previous page... Please make sure that all of the issues we are requesting for the P & Z hearing have been addressed. If they haven't, this may delay the project. The comments presented above are the "major" comments found on the respective sheets. Refer to the plan set for additional comments and concerns. Please find enclosed a form to be filled out pertaining to the development agreement. This does not mean that the development agreement process has begun. It simply, is to allow you enough time to gather the required information that is needed. Our goal is that by doing this the development agreement process will not be delayed when it comes time to writing it. PROJECT COMMENT SHEET City of Fort Collins Current Plannins DATE:7-24-96 DEPT: ENGINEERING PROJECT: Harmony Town Center - Prelim. PLANNER: Mike Ludwig All comments must be received by: ❑ No Problems L-t" Problems or Concerns (see below or attached) 1 Need an amended traffic study to reflect plan changes and address CDOT's comments from their 3-9-96 comment letter. 2_ Pavilion Lane is currently 36' wide (residential standard) but is changing functions to a commercial l industrial street requiring a 44' pavement width and 62' R.O.W.; the amended traffic study should evaluate Pavilion Lane to determine the street requirements. 3 Need to incorporate an 8' bike lane on N. side of Harmony and 6' bike lanes on JFK. 4 Please indicate Harmony and College centerlines and dimension their R_O.W. width and their relation to the section line. 5 Please include a North bound right turn lane on College at Kensington. 6_ Please include I S' (minimum) utility easements along all property fronting an arterial_ 7 Please delete .he transit stop on Harmony Rd . Service may be possible from onsite or possibly JFK. 8 As configured, Kensington will become a private drive and will require an access easement. 9 No landscape plans with the 7-24-96 arch. plan set. 10 The above comments also apply to the architectural plans. These comments are related to the prelim- utility plans stamped June 26, 1996 and the architectural plans dated (resub) 7-24-96. Date: 7-;z q- C/&" PLEASE SEND COPIES OF MARKED Signature: REVISIONS- PLAT SITE G�-tTILITY E3�LANDSCAPE PROJECT COMMENT SHEET Citv of Fort Collins Current Planning DATE: al q tea DEPARTMENT: C-1KY:1 PROJECT: PLANNER: All comments must be received by: �L (, i q q (P ❑ No Problems No L� Problems or Concerns (see below or attached) 1. Cover Sheet - Address Gen. Notes comments. _Q. Prelim. Plat - Need 15' utility easement along adjacent to both arterials. = 3= Prelim. Plat - Harmony Road - half ROW with right turn lane to be 72' wide. Prelim. Plat - Harmony Road - half ROW without right turn lane to be 60' wide. 5 Prelim. Plat -College Ave.- additional 16' ROW from flowline needed. 6- Engr'g Site Plan - Need detached sidewalks along JFK; Harmony and College. 7_ Engr'g Site Plan - All street and intersection improvements by developer .- 8 Engr'g Site Plan - JFK to tie in to existing JFK North of project with this development. 9. Engr'g Site Plan - Two smaller accesses off of Harmony will need State Highway Access Permits (CDOT approval) plus will require medians. Date: ` - -' Signature: CHECK IF YOU LAVISH TO RECEIVE ❑PLAT COPIES OF REVISIONS bSITE M�—LANDSCAPE 0—TILITY 8. The Natural Resources Department offers the following comments: a. Additional landscaping is needed along College Avenue. b. The trash enclosure must be large enough to accommodate trash and recycling dumpsters. C. It appears that cars using the drive-thru on the east side of the building will be routed through the Schrader's gas station property. This does not seem appropriate. 9. U S WEST offers the following comments: a. Review of these plans should not be construed as a commitment that telephone facilities sufficient to sere this project are presently available. U S WEST will provide telephone service in accordance with the rates and tariffs on file with the Colorado Public Utilities Commission. b. The owner is responsible for provision of all conduit, ditch crossings, and street crossings for telephone facilities within the project. The owner also provides terminal room space (usually 8' x 4') and power for the telephone terminal, generally in a utility room. Contact the U S West engineer for conduit specifications for the telephone entrance cable. C. Any relocation of existing telephone facilities required by these plans will be paid for by the developer. 10. The Poudre Fire Authority offers the following comments: a. Fire hydrants are required with a maximum spacing of 600 feet along and "approved roadway". Each hydrant must be capable of delivering one -thousand (1,000) gallons of water per minute at a residual pressure of twenty (20) pounds. No building can be greater than 300 feet from a fire hydrant as measured from the building to the hydrant along the approved roadway. b. A table found in the 1991 Uniform Building Code Appendix III-B relates construction and area to required fire flows. C. Proposed building (Pad 1) exceeds 5000 square feet and must be fire contained or equipped with an automated fire suppression system. (Local Amendment to Table 38B UBC). d. If building is equipped with a fire sprinkler or fire alarm system, a "knox box is required.