DATE: November 19, 2002 TO: Engineering Pavement
PROJECT: #45-02 HOWES/CANYON MIXED -USE PDP-TYPE II (LUC)
All comments must be received by Bob Barkeen no later than the staff
review meeting:
December 18, 2002
Note - PLEASE identify your redlines for future reference
R, cic Q,.c1—
Name (please print)
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
_Plat _Site _Drainage Report _Other
_Utility _Redline Utility _Landscape
City of Fort Collins
Several details are included that are not needed. Please remove.
Also, since the last submid:al, Inspection has chosen a different detail (attached) to be used only for the texture and
dimension of the surface to replace the colored concrete square on the City's standard ramp details.
Number: 89 Created: 3/3/2003
Please use drawing 1101 for the handrail detail.
Number: 101 Created: 3/7/2003
Please provide a detail of the non-standard driveway including ramp transitions for the sidewalk and a cross-section.
Page 3
Project Comments Sheet
Selected Departments
Cityof Fort Co]lins
Department: Engineering
Date: Ntay 7, 2003
Project: FIOWES/CANYON MIXED -USE PDP - TYPE II (LUC) - #45-02
All comments must be received by Bob Barkeen in Current Planning, no later than
the staff review meeting:
April 30, 2003
Mote - Please identify your redlines for future reference
Issue Contact: Katie Moore
Topic: General
Number: 36 Created: 12/11 /2002
Please see redlines and utility plan checklist for any additional comments.
3.3.03 - repeat
4.15.03 - repeat
Number: 99 Created: 3/6/2003
Where will the roof drains outlet? Please note that they will not be allowed to outlet over a public sidewalk - under -walk
drains would be required.
4.15.03 - repeat
Number: 100 Created: 3/6/2003
If under -ROW storage is approved, please provide detailed plans for it.
4.15.03 - A detailed structural design will be required prior to final plan approval.
Number: 109 Created: 4/15/2003
The sidewalk width along Howes needs to maintain at least 8' of clear walk along the steps at the corner. (6' for the walk
plus 2' shy distance from the steps)
Number: 110 Created: 4/15/2003
Please show outlines of underground structures on the site/landscape plans.
Number: 111 Created: 4/15/2003
Please use the mid -block location detail from Drawing 1603 (LCUA55) for the handicap parking stall ramp.
Number: 116 Created: 5/1/2003
Where the storm sewer runs under the sidewalk, thicker concrete for the walk will be required (8").
Number: 117 Created: 5/1/2003
Please show where the perimeter drainage system/sump pit will outlet, and show the location of the sump pit.
Signature -;X (�, C,CZ
Date iL.0j
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat Site Drainage Report Other
Utility Redline Utility "' Landscape
Page 1
Topic: Site Plan
Number: 13 Created: 12/11 /2002
Encroachment permits are required for seat walls/columns/steps/etc. in the ROW. Also, an agreement with the DDA must
be provided for the maintenance of these items, and for special paving.
3.3.03 - Please provide a letter of intent from the DDA prior to hearing, the encroachment permits are not required after
all.
Number: 16 Created: 12/11/2002
Please see redlines and landscape plan for further comments.
Repeat 3.3.03
Topic: Grading plan
Number: 112 Created: 4/1512003
It appears that the layer with the spot elevations got turned off; please turn it back on.
Number: 113
Is section A -A drawn to scale?
Created: 4/15/2003
Number: 114 Created: 4/15/2003
It looks like there will be a problem with cars bottoming out when coming out of the parking garage. Changing the grades
isn't required, but please know that the property owner/developer will be responsible for the maintenance of that driveway.
Topic: Overall Utility Plan
Number: 83 Created: 3/3/2003
Please show where the drain that collects the water from the driveway down to the underground parking will drain to.
Repeat 4.15.03
Topic: Storm Drain Profile
Number: 98 Created: 3/6/2003
There has been a change in policy regarding the use of geotextiles when less than 2' of cover is provided: only concrete
pavement will be allowed in these locations, and textiles are no longer allowed.
4.1 5.03 - A variance will be required to allow less than minimum cover over the stormpipe. Please submit a variance in
accordance with the requirements in LCUASS. If the variance is approved, notes will be required on the utility plans (on
the plan and profile sheet) and the Development Construction permit referencing the variance. To gain cover over the
pipe, consider using D.I.P. or C900.
Page 2
Project Comments Sheet
Selected Departments
of Fort Collins
Department: Engineering
Date: September 26, 2003
Project:
HOWES/CANYON MIXED -USE PDP - TYPE II (LUC) 8, FINAL
COMPLIANCE
All comments must be received by Bob Barkeen in Current Planning, no later than
the staff review meeting:
September 24, 2003
Note - Please identify your redlines for future reference
Issue Contact: Katie Moore
Topic: General
Number: 131 Created: 9/22/2003
The proposed widening of the bump out into the street will not be permitted due to the adverse effects on parking on the
north/west side of the street. Please work within the horizontal layout previously approved. Steeper slopes may be
permitted on the driveway (6-8%) as long as adequate visiblity of pedestrians is maintained. Other suggestions for working
on the driveway include notching up the building structure over the driveway to attain more headroom and adding a
Floodgate to keep storm Flows from entering the garage. As stated in the meeting by Stormwater, do your best to keep as
much Flow as possible in the gutter.
Number: 132 Created: 9/22/2003
Since the proposed drive -over curb and gutter does not match a standard detail, please submit a detail drawing and
variance request. Also, please note on the plans that this curb can never be altered due to stormwater problems (further
elaboration may be needed on the plans).
N ber: 3 Created: 9/22/2003
Since a iginaI agreement with the property to the south does not address the addition of storage units on their
proper lease resubmit a copy of an agreement addressing the additional underground use of their property and the
' ad cnal a a needed. T;eE,o)Ved 9,2%.03 — 1 ecL'L \Pe
Number: 139 Created: 9/23/2003
There is still one door on the east side of the building shown to open over the ROW. Please remove or recess this door.
Mike Gebo in Building and Zoning is a good person to talk to regarding this requirement.
Topic: Landscape plan
Number: 140 Created: 9/23/2003
Please show the outlines of the underground storage units and note that no excavation will be allowed within 7' of the
center of any trees (per the City Forester).
Signature Date
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
f Plat Site Drainage Report Other_
f Utility- _ ✓ Redline Utility ,, Landscape
Page 1
Number: 142 Created: 9/23/2003
The landscape plan shows two different stormpipe layouts. Please show only the correct one.
Topic: Lease
Number: 143 C� Created: 9/25/2003
In order to move forward with the lease, a plat of the leased area will be needed, as previously discussed. Completion of
the plat will be required prior to Certificate of Occupancy on the building, unless complications arise if the plat is appealed.
In this case a substitute form of documentation (to be determined) of the leased area will be required and the plat will no
longer be required. It is anticipated that the review and hearing process for the plat (barring an appeal) could be
completed quickly.
Topic: Utility plans
Number: 134 Created: 9/23/2003
The stormpipe in Canyon is not allowed to be PVC. Please remove that option from the plans.
Topic: Overall Utility Plan
Number: 138 Created: 9/23/2003
1 still have not received the variance request to have less than 2' of cover over the stormpipe in Canyon. Please submit a
variance request for this item so that we can determine the best solution to be implemented.
Topic: Canyon Avenue Profile
Number: 135 Created: 9/23/2003
The minimum Flowline grade allowed is 0.5%, and a portion on the profile is shown at 0.44%. Please revise.
Topic: Grading plan
Number: 114 Created: 4/15/2003
It looks like there will be a problem with cars bottoming out when coming out of the parking garage. Changing the grades
isn't required, but please know that the property owner/developer will be responsible for the maintenance of that driveway.
9.22.03 - Repeat as FYI.
Page 2
PROJECT
...-1 COMMENT SHEET
City of Fort Collins, REM '030C
Current Planning
DATE: October 10, 2003 TO: Technical Services
PROJECT: #45-02B HOWES/CANYON MIXED -USE PDP
IZEPLAT — TYPE I (LUC)
All comments must be received by Bob Barkeen no later than the staff
review meeting:
Noveffifter 5, 2003
Note - PLEASE identify your redlines for future reference
/, EASEME�i 5 CCnsE� cAScME•✓T Z GEGAG S�t/e� iyfATC�1 1//Z5 IV41,
LAJ LJ I k— �_ N a-(s D
V\�(�' i �r
Name (please print)
�S e- T-fIts FTN k
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
'14lat _Site _Drainage Report _Other
_Utility _Redline Utility _Landscape
Pi.4 T
ON of Fort Collins
2:2
October 13, 2003
Mr. Bob Barkeen
City of Fort Collins
Current Planning
281 North College Avenue
Fort Collins CO 80521
Re: Cortina Mixed Use Building PDP- Type II Final Compliance
Dear Bob:
Following are responses to Staff's 9/29/2003 review:
Engineering:
Canyon Avenue Profile
Number 135
The flowline slope has been revised to .0.5% minimum.
General
Number 131
Revised — see new design.
Number 132
he entry now has a standard 4' wide pan.
Number 139
Per conversations between Bill Coulson and Lance Newland, the door can swing into
the right of way because it is only a fire exit and not a highly used door.
Number 141
The handicap ramp (and therefore, handicap parking stall) is located to prevent the
ramp from being in front of the stairs. We prefer to leave the ramp in the location
shown.
Grading Plan
Number 114
Acknowledged.
Landscape Plan
Number 140
The underground storage has been shown on the revised site and landscape plans and
a note has been placed on the landscape plan with the City Forester's requested
language.
Number 142
The correct stormpipe, water and sever services are now shown on the landscape plan.
Overall Utility Plan
Number 138
This variance request is attached.
Site Plan
Number 13
Acknowledged. The agreement with the DDA will be provided.
Utility Plans
Number 134
PVC option was removed. Pipe will be ductile.
Light & Power
Electric
Number 126
Developer is coordinating with Light & Power. The location will be near the southeast
corner of the building.
Stormwater Utility
Drainage
Number 137
Flood proofing is proposed. Complete design will be provided by the manufacturer and
the developer.
Erosion/Sediment Control
Number 136
Adjusted the silt fenice per Bob Zakley.
Water/Wastewater
General
Number 127
Landscape Plan has been coordinated with Utility Plans.
Number 128
Revised per your request.
Number 129
The Homeowners Documents will have a clause addressing this issue. These
documents will be provided to you prior to issuance of certificate of occupancy.
Number 130
The location is accurate and coordinated with the architecturals.
Project Comments Sheet
Selected Departments
City of Fort Collins
Department: Engineering
Date: October 30, 2003
Project: HOWES/CANYON MIXED -USE PDP REPLAT - TYPE I (LUC)
All comments must be received by Bob Barkeen in Current Planning, no later than
the staff review meeting:
October 29, 2003
Note - Please identify your redlines for future reference
Issue Contact: Katie Moore
Topic: General
Number: 3 Created: 10/28/2003
[ 10/28/031 The document provided is not a plat. Please provide a plat as discussed with Wally Muscott, with the plat
language and signatures needed. Please provide a space to identify the reception number for the lease connected to the
underground lease area (this area is not an easement). Please see redlines for additional comments.
Number: 4 Created: 10/30/2003
[ 10/30/031 Additional comments from Wally:
1. Easements close, easement #2 legal doesn't match the map.
2. We will need to see the final plat.
/o , ZI.a3
Date
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat _ Site Drainage Report Other
Utility _ Redline Utility Landscape
Page 1
Project Comments Sheet
Selected Departments
Department: Engineering
Date: December 18, 2002
Project: HOWES/CANYON MIXED -USE PDP - TYPE II (LUC) - #45-02
All comments must be received by BOB BARKEEN in Current Planning no later than
the staff review meeting:
December 18, 2002
Note - Please identify your redlines for future reference
Issue Contact: Katie Moore
Topic: General
36 Please see redlines and utility plan checklist for any additional comments.
47 The variance request for the driveway downslope within the ROW was not
approved. Please see the attached letter for further information.
48 The variance request for the attached sidewalk was not approved, and a
bumpout will not be supported in this location either. Please see the attached letter
for further information.
49 Please provide more information regarding the underground parking south of
the building.
62 The following is a request: please widen the sidewalk on the east side of the
building so that the full length of the sidewalk's right edge aligns with the right edge
of the sidewalk offsite to the south.
The following is a requirement: the right edges of the existing and proposed
sidewalks there should align across the driveway (the sidewalk onsite may transition
to the 8' width as it heads north).
Topic: Building Elevations
11 Please make sure that what is shown on the building elevations matches
what is shown on the grading/utility plans (most noticeably the garage door depth).
Topic: Site Plan
12 Building doors are not allowed to open over the ROW. Please recess them or
find some other solution.
Date
CHECK :HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat V Site Drainage Report Other
_ Utility _ Redline Utility _ Landscape
Page 1
Project Comments Sheet
062nd■I Selected Departments
CAN, of Fort Collins
���
Department: Engineering
Date: November 4, 2003
Project: HOWES/CANYON MIXED -USE PD REPLAT - YPE I (LUC)
All comments must be received by Bob Barkeen in Current Planning, no later than
the staff review meeting:
October 29, 2003
Note - Please identify your redlines for future reference
Issue Contact: Katie Moore
Topic: General
Number: 6 Created: 11 /4/2003
[ 1 1 /4/03] Please remove the owners (Howes/Canyon LLC and Coulson Development Group, INC) from the plan view of
the plat as redlined.
Number: 7 Created: 11 /4/2003
[1 I /4/03] On the leased areas, please call out the base elevation as approved by Council.
Number: 8 Created: 11 /4/2003
[1 1 /4/03] Please specify that the leased areas were leased to Cortina Homeowners' Association.
Signature
n.5.o3
Date
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
✓� Plat _ Site Drainage Report Other
Utility __ Redline Utility Landscape
Page 1
Project Comments Sheet
Selected Departments
City of Fort Collins
Department: Engineering
Date: November 6, 2003
Project:
HOWES/CANYON MIXED -USE PDP - TYPE II (LUC) & FINAL
COMPLIANCE
All comments must be received by Bob Barkeen in Current Planning, no later than
the staff review meeting:
November 5, 2003
Note - Please identify your redlines for future reference
Issue Contact: Katie Moore
Topic: Flood Wall
Number: 145 Created: 11/4/2003
[ 1 1 /4/031 Please provide further detail for the flood wall, including dimensions and how It works with the retaining walls.
Please provide the manufacturer's information and recommended installation. After reviewing this information it will be
determined what else needs to be shown on the plans. How does it get drained? Where will the water drain to? Will there
be a groove in the retaining wall for the flood wall and will it be a waterproof seal? What materials is it made from? Is -10"
a high enough wall? Etc. Also, call out the concrete thickness of the cross -pan on the cross-section as B" minimum.
Prior to resubmittingmy otans please call to set up a meeting with Engineering, Stormwater, and
Water/Wastewater regarding the flood wall.
Number: 146 Created: 11/4/2003
[ 1 1 /4/03] Please be sure to show the flood wall location on all plans.
Topic: General
Number: 36 Created: 12/11/2002
[ 1 1 /4/031 Repeat of original comment:
Please see redlines and utility plan checklist for any additional comments.
3.3.03 - repeat
4.15.03 - repeat
Number: 99 Created: 3/6/2003
[ 1 1 /4/03] Repeat of original comment:
Where will the roof drains outlet? Please note that they will not be allowed to outlet over a public sidewalk - under -walk
drains would be required.
4.15.03 - repeat
8.6,65
Dare
CHECK HE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat t� Site Drainage Report Other
t� Utility Redline Utility =Landscape
Page 1
Number: 100 Created: 3/6/2003
111/4/03] Please submit a copy of the structural calculations for the storage in the ROW for city files. Also, please add the
standard city signature block to the plan sheets and submit the sheets on mylar for signature along with the rest of the mylars
(as part of the utility plan set). The final paper copies for City files will need to be signed and stamped by a Colorado PE, just
like the rest of the utility Plan sheets.
Original comment:
If under -ROW storage is approved, please provide detailed plans for it.
4.15.03 - A detailed structural design will be required prior to plan approval.
9.22.03 - A very preliminary design was submitted prior to the lease approval going before Council, but this design needs
to be completed and resubmitted for review.
Number: 117 Created: 5/1/2003
[ 1 1 /4/031 Repeat of original comment
Please show where the perimeter drainage system/sump pit will oudet, and show the location of the sump pIL
Number: 132 Created: 9/22/2003
It 1/4/031 A variance request and further detail is still needed for this non-standard driveway approach section. How will the
transitions at the pan widening be constructed? What is shown does not match any City of Fort Collins standard, but from what
is shown, the variance would be supported. Again, please note on the plans that this curb cannot be altered in the future.
Also, FYI, the slopes shown for the driveway are acceptable.
Original comment.•
Since the proposed drive -over curb and gutter does not match a standard detail, please submit a detail drawing and
variance request. Also, please note on the plans that this curb can never be altered due to stormwater problems (further
elaboration may be needed on the plans).
Number: 147 Created: 11 /4/2003
[ 1 1 /4/031 Please call out the distance from flowline to flowline on Canyon, as well as the distance from the edge of
parking stalls to the east flowline on Canyon.
Topic: Landscape plan
Number: 140 Created: 9/23/2003
[ 1 1 /4/03] Now that the outlines have been shown, it appears that one of the existing trees on Canyon will not be outside
of this 7' area. Please note on the plans to contact the City Forester regarding tree protection prior to
construction.
Original comment:
Please show the outlines of the underground storage units and note that no excavation will be allowed within 7' of the
center of any trees (per the City Forester).
Number: 142 Created: 9/23/2003
[ 11 /4/03] Now only one is shown, but It doesn't match the one shown on the utility plans. Please coordinate.
Original comment:
The landscape plan shows two different stormpipe layouts. Please show only the correct one.
Topic: Overall Utility Plan
Number: 83 Created: 3/3/2003
[ 1 1 /4/03] Repeat of original comment -
Please show where the drain that collects the water from the driveway down to the underground parking will drain to.
Repeat 4.15.03
Page 2
FINAL COMPLIANCE
6a�
REVISION
City Fort I COMMENT SHEET
Current
nt Planniannin.a
DATE: November 12, 2003 TO: Engineering
PROJECT: #45-02A Howes/Canyon Mixed -Use PDP — Final
Compliance
All comments must be received by Bob Barkeen no later than the staff
review meeting:
November 26, 2003
Note - Please identify your redlines for future reference
fkav, &tf-74t ho``' Raw on oanven i 1ilol yel was
' �(� �a �Dt Si,t,b►'vllt ryty la.� u''�t� � -�t,e. �eaa� ed l'o cyi p�
Name (please print)
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
/Plat _Site _Drainage Report _Other
_Utility _Redline Utility _Landscape
E a 'EMOU1
FINAL COMPLIANC
REVISION
City of Fort Callin:I COMMENT SHEET
Current PlanninE
DATE: November 12, 2003 TO: Technical Services
PROJECT: #E45-02A Howes/Canyon Mixed -Use PDP — Final
Compliance
All comments must be received by Bob Barkeen no later than the staff
review meeting:
November 26, 2003 M
Note - Please identify your redlines for future reference
(, BvuNoq,2Y � L£GFIL CLOScS_
Name (please print)
7HERE IF Yg,U WISH TO RECEIVE COPIES OF REVISIONS
_Site _Drainage Report Other
_Utility _Redline Utility _Landscape
6=1 ^&16m Me.0
City of Fort Collins
i
Project Comments Sheet
Selected Departments
City of Fort Collins
Department: Engineering
Date: December 18, 2003
Project:
HOWES/CANYON MIXED -USE PDP - TYPE II (LUC) & FINAL
COMPLIANCE
All comments must be received by Bob Barkeen in Current Planning, no later than
the staff review meeting:
Note - Please identify your redlines for future reference
Issue Contact: Katie Moore
Topic: Detail Sheet
Number: 162 Created: 12/18/2003
[ 12/ 18/03] Please see redlines and provide more detail regarding the driveway construction.
Topic: Flood Wall
Number: 145 Created: 11 /4/2003
[12/16/03] Repeat: The cross -pan should be noted as 8" thick concrete.
[ 11/4/03] Please provide further detail for the flood wall, including dimensions and hei.A., it viepics with the retaining walls.
Please -provide -the -manufac JreFs- information -and -reEe er�rw;e. •^^ this information It will be
ahigh-enough-wall?—€tc. Also, call out the concrete thickness of the cross -pan on the cross-section as 8" minimum.
Q•o.-.o-.��u4mitcing=a-�ans�- I_ease-call-te-set-u..a-meet"wit,�€„s;,,�
Wate egg
Number: 146 Created: 11/4/2003
[12116103] Repeat: The flood wall location is still not shown on the site and landscape plans.
[11/4/031 Please be sure to show the flood wall location on all plans.
Number: 160 Created: 12/18/2003
[12/18/031 Please reinstate the cross-section of the underground storage units.
Topic: General
Number: 36 Created: 12/11 /2002
[12/18/031
[ 1 1 /4/031 Repeat of original comment:
Please see redlines and utility plan checklist for any additional comments.
3.3.03 - repeat
4.15.03 - repeat
/Z./9o3
Date
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat / Site Drainage Report Other
L Utility = Redline Utility Landscape
Page I
Number: 132 Created: 9/22/2003
(12/18103] The variance was approved, see the attached approval fetter. Please reinstate the cross-section previously shown
that showed the drive approach and the slopes down the driveway to the underground parking to clarify what's going
on.
[11/4/03] A variance request and further detail is still needed for this non-standard driveway approach section. How will the
transitions at the pan widening be constructed? What is shown does not match any City of Fort Collins standard, but from what
is shown, the variance would be supported, Again, please note on the plans that this curb cannot be altered in the future.
Also, FYI, the slopes shown for the driveway are acceptable.
Original comment:
Since the proposed drive over curb and gutter does not match a standard detail, please submit a detail drawing and
variance request. Also, please note on the plans that this curb can never be altered due to stormwater problems (further
elaboration may be needed on the plans).
Number: 161 Created: 12/18/2003
[ 12/ 18/031 Please provide the dimension of the distance from the end of the retaining walls to where the Floodgate will
be installed. Also, please ensure that the retaining wall height is the same as the Floodgate height. In the meeting on
12/17, a 1 S" Floodgate was discussed, which would add approx. 7" to the retaining wall heights.
Topic: Landscape plan
Number: 140 Created: 9/23/2003
[ 12/ 16/031 Repeat: Add a note to the landscape plan to contact the City Forester prior to construction regarding tree
protection.
[ 1 1 /4/031 Now that the outlines have been shown, it appears that one of the existing trees on Canyon will not be outside
of this 7' area. Please note on the plans to contact the City Forester regarding tree protection prior to
construction.
Original comment:
Please show the outlines of the underground storage units and note that no excavation will be allowed within 7' of the
center of any trees (per the City Forester).
Page 2
13 Encroachment permits are required for seat walls/columns/steps/etc. in the
ROW. Also, an agreement with the DDA must be provided for the maintenance of
these items, and for special paving.
14 The curb and gutter shown near the northernmost inlet doesn't match the
utility plans.
15 FYI -Utilities are not required to be shown on the site plan, but are required on
the landscape plan.
16 Please see redlines and landscape plan for further comments.
Topic: Landscape plan
17 Please label property lines/ROW lines (typ).
18 Columns in ROW must be at least 2 feet from the curb.
19 There are aireas where it is unclear whether plants or paving are proposed.
Please clarify.
Topic: Utility Plan Cover Sheet
20 The title needs to be changed since symbols aren't acceptable in the title, and
the title doesn't match what is used for the Site and Landscape plans. The preamble
should also have the addition of: Public Improvement (Construction Plans For).
21 The index indicates a plat is included, but a plat was not submitted.
22 Please provide the benchmark identifier numbers.
37 Please provide a reference to the soils report.
Topic: Utility Plan General Notes sheet
23 Please correct typos as redlined.
Topic: Grading plan
24 If the flowline is to be altered, please provide a profile of the new curb and
gutter and how it ties to the existing curb and gutter.
25 What are the heights and widths of the steps in the ROW?
26 Driveways need to be a maximum of 4% grade for a car length beyond the
back of the sidewalk. (The variance request for the driveway as shown was denied.)
27 What is the FF of the basement level?
28 Please show new contour lines.
38 Please provide the finish grade elevations of the lot corners.
61 How will water get out of the basement level?
Topic: Overall Utility Plan
29 Please show that driveways will be concrete to the property line.
Page 2
30 The street cut note should be expanded to say: Limits of street cut are
approximate. Final limits are to be determined in the field by the City Engineering
Inspector. All repairs are to be in accordance with City street repair standards.
31 Street cuts need to be made to the edge or middle of the lane.
39 Please dimension and label property/ROW lines.
Topic: Storm Drain Profile
32 For Storm 1 profile: It appears that the pipe cannot be lowered; since 2' of
cover to the subgrade cannot be achieved, a geogrid/geotextile will be required
above the pipe.
Topic: Detail Sheet
33 Please see the attached ADA requirements for ped ramps and include the
drawings on the detail sheet.
34 Please specify which details are to be on -site only.
35 It appears that certain details are extraneous and not needed on the plans.
Page 3
X
l ands :�po A1111.1 clure Urban pesl9n Planning
February 12, 2003
Bob Barkeen
City of Fort Collins Planning Department
281 North College Avenue
PO Box 580
Fort Collins, CC) 80522
RE: Response to Staff Comment letter dated December 30, 2002
Dear Bob,
The comments below address the issues raised by city staff regarding the
Canyon/Howes Mixed -Use Project.
Advanced Plannin
Site Plan
66 Regarding sidewalks and pedestrian connections along Canyon. We recognize
that the pedestrian has to walk along an attached sidewalk for a short distance due to
the curb bulges and large existing Ash tree. However, we feel that the primary
pedestrian experience is enhanced along the building. Here is opportunity for artwork,
special paving, planters, etc. The Tower" level (T walk) was intended for people to get
from the diagonally parked cars to the building without having to go through a
landscape area. In addition, there are several existing trees that prevent a continuous
connection along the `lower" level.
Current Planning
Site Plan
67 A modification request is being submitted with the revisions.
68 We have provided additional information.
69 We had requested an Alternative Compliance to Section 3.2.1(E)(4)(a) and (b)
for the perimeter landscaping requirements for the small parking lot. Since trees,
shrubs or irrigation above the parking structure are prohibited, we proposed screening
with a 6-foot solid cedar fence and landscape cobble. The LUC requires the parking lot
be screened from residential uses by a 6-foot fence. The Ash and Siberian Elm trees
along the west end of the Linden Press parking lot are to be removed.
Engineering:
Building Elevations
11 The architectural elevations have been revised to reflect the current grading.
Phone 970.224. 5828 Fax 970.224. 1662
401 West Mountain Ave. Suite 201
Fort Collins, CO 80521-2604
O uplay. com
Detail Sheet
33 The ADA ramps have been added to the plans as well as the detail.
34 See revised utility plans.
35 Removed from plans
General
36 Acknowledged.
49 We are providing a drawing of the underground parking structure in the utility
plan set.
62 The sidewalk has been widened to align with the existing walk to the south
Grading Plan
24 New flowline, curb and gutter has been shown on the utility plans.
25 The height and widths of the steps have been added to the plans.
26 The driveway is 4% for 16 feet, then 16% into the parking structure.
27 See sheet 4A of the utility plans.
28 Contour lines shown.
38 Grade elevations have been added to the lot corners.
61 There is a note regarding a sand/oil separator on the utility plans.
Landscape Plan
17 Property lines/ROW have been labeled.
18 Columns have been moved.
19 We tried to clean the plan up so it reads better.
Overall Utility Plan
29 Acknowledged.
30 Acknowledged.
31 An additional sanitary service has been added.
44 See revised utility plans.
45 Acknowledged.
46 Acknowledged.
Site Plan
40 The bike rack has been shifted to the north to clear the meter pit and water
lines.
41 Plumbing calcs are Included with resubmittal.
Zoning:
3 The existing trees have been removed from the site plan as requested.
4 The widths have been added to the parking stalls.
5 The revised bedroom and parking counts are located on the Land Use
Breakdown on the site plan sheet.
6 The building envelope has been labeled on the site plan, as well as dimensions
of property lines and setbacks.
7 In addition to the outdoor trash/recycling enclosure, there are recycling facilities
within the building on each floor.
8 There is an existing street light at the northeast corner of the site. We don't
anticipate any additional lights beyond what is being proposed on -site.
9 We could not locate an existing ramp at the driveway for the Linden Press
building. The sidewalk continues across the drive.
10 The Ash trees are small and multi -stemmed and would be impossible to relocate
so we are showing them as being removed on the landscape plan.
Please let us know if you have any further issues or questions about this project.
Sincerely,
Ca. Aq rrlaAw
Cathy Mathis
VF Ripley Associates
City of Fort Collins
Project Comments Sheet
Selected Departments
Department: Engineering
Date: March 6, 2003
Project: HOWES/CANYON MIXED -USE POP - TYPE 11 (LUC) - 445-02
All comments must be received by Bob Barkeen in Current Planning, no later than
the staff review meeting:
March 05, 2003
Note - Please identify your redlines for future reference
Issue Contact: Katie Moore
Topic: General
Number: 36 Created: 12/11 /2002
Please see redlines and utility plan checklist for any additional comments.
3 3.03 - repeat
Number: 90 Created: 3/3/2003
Prior :(o hearing, please provide a letter of intent from the owners of the Linden Press property regarding this prolect's use
of their property and that they plan on completing any needed easements or other agreements for that use.
Number: 92 Created: 3/3/2003
It appears that easements for construction of the underground parking structure on the south side of the site will be needed
from the neighboring property owners (south of Linden Press and south of the mechanical building). Please provide letters
of intent prior to nearing.
Where will staging take place?
Number: 99 Created: 3/6/2003
Where will the roof drains outlet? Please note that they will not be allowed to outlet over a public sidewalk - under -walk
drains would be required.
Number: 100 Created: 3/6/2003
If under -ROW storage is approved, please provide detailed plans for it.
Topic: Site Plan
Number: 13 Created: 12/11 /2002
Encroachment permits are required for seat walls/columns/steps/etc. in the ROW. Also, an agreement with the DDA must
be provided for the maintenance of these items, and for special paving.
3.3.03 - Please provide a letter of intent from the DDA prior to hearing.
Number: 16 Created: 12/11/2002
Please see redlines and landscape plan for further comments.
Repeat 3.3.03_ v
/b Il,
Date
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat Site _—Drainage Report Other_
I!tilih _ Redline Utility _X_ Landscape
Pace I
Topic: Utility Plan Cover Sheet
Number: 79 Created: 3/3/2003
Th onnet bolt survey is no longer in use. Please use COFC vertical control
Number: 91 Created: 3/3/2003
Piese include sheet 4a in the index and sheet numbering/totals.
Topic:. Drainage
Number: 88 Created: 3/3/2003
—1t-pears that the layer showing the proposed bumpout/driveways was turned off for this sheet. Please show it.
Topic: Grading plan
-- Number:28 Created:12/11/2002
Please show new contour lines.
3.3.03 - It would help to have a more distinctive (thicker?) line type for the new contours. They're currently difficult to
pick out.
Number: 80 Created: 3/3/2003
The southernmost driveway on Canyon should be a Type 2 driveway, with the corresponding ramp type for the sidewalks,
the same as the driveway down to the underground parking.
Number: 81 Created: 3/3/2003
The ramp heading north at the corner of Canyon and Howes should have a width at least equal to the ramp across the
street from It.
Topic: Overall Utility Plan
_ Number:39 Created:12/11/2002
Please dimension and label property lines/ROW.
3.3.03 - repeat
Num er:82 Created: 3/3/2003
Bo driveways need to be concrete to the ROW line.
Number: 83 Created: 3/3/2003
Please show where the drain that collects the water from the driveway down to the underground parking will drain to.
Topic: Storm Drain Profile
Number: 98 Created: 3/6/2003
There has been a change in policy regarding the use of geotextiles when less than 2' of cover is provided: only concrete
pavement will be allowed in these locations, and textiles are no longer allowed.
Topic: Canyon Avenue Profile
Number: 84 Created: 3/3/2003
Not enoq data was provided to verify that cross -slopes will be adequate. Please provide elevations on the centerline
profJefor this purpose.
Number: 85 Created: 3/3/2003
Centerline stationing is required per LCUASS for all street design.
NumbeP-86 Created: 3/3/2003
The imum fiowline grade is 0.5%, and there is a large section of curb that does not meet this requirement.
Topic: Detail Sheet
Number: 87
Page 2
Created: 3/3/2003