HomeMy WebLinkAboutDIXON CREEK PUD - Filed CS-COMMENT SHEETS - 2003-07-31C ONCE P T L- .el.- REVIEW
STA FF COMMENTS
DATE: 2/211/80
-- Overland and Drake Property Annexation and Zoning Ix Cess
I- . _ - -
PPP IC1-'.N T: ZVFK for Miller Brothers
C_1 N'D USE DATA:
58 acres
C0 ►,ri M E= N T S :
1. Should locate existing 75 foot easement along West property line.
2. Office uses are not presently. -a proper use of the commercial
allottment. Would recommend that if the applicant wishes to pursue
offices, that they request an appropriate zoning classification - BL
or BP.
3. The alignment of Overland Trail extension has not been finalized.
The applicant should work with staff to develop a suitable alignment.
4. The applicant should seriously consider in developing the site
plan energy conservation and application of solar access methods.
5. The applicants should carefully consider impact of locating
high density uses on the west perimeter of the property and its
impact on encouraging further development to the west.
6. Access points should be provided to the east and south.
City of Fort Collins
December 5, 1 S183
Page 2
STORM DRAINAGE;
The pervious and impervious ground areas are not being changed signifi-
cantly from the current approved plans for the project. Therefore, storm
runoff rates and volumes previously designed should still be adequate.
From our experience with P.M.'s in the past few years, it has become
apparent that overland flow is a more economically maintained system than
underground Storm sewers. The P.U.D. can permit the natural surface tex-
ture to be retained in areas where it is most beneficial in the control of
runoff. Open space, in a size and location most suitable for storm water
detention, is a controllable aspect of the P.U.D., as is obvious in Dixon
Creek.
We are proposing to replace all underground stormwater conduits in Tracts
1, 2, 5, 6 and 7 with overland flow systems. Of course, street culverts
and detention pond outlet pipes will remain. This proposal will allow a
system maintainable by the homeowner's. They are not prepared with a means
to maintain underground pipes, but are well aware of the greenway mainte-
nance requirements.
If this is an acceptable proposal, please let us know and we will revise
grading and drainage plans in this portion of the project for your review
and acceptance.
Upon an indication that the site plan as revised is acceptable at the staff
level, we are prepared to modify the utility plan. We will show parking
and sidewalks as indicated on the site plans.
Sidewalks on Drake Road will be shown as 7' wide adjacent to the curb for
75' from the intersections. They will then detach from the curb through a
minimum 60' reverse curve and transition to 5' width.
Overland Trail sidewalks will be similar except, because It is a major
arterial, the walk will be continuous 7' wide.
City of Fort Collins
December 5, iS183
Page 3
Should any of the City's staff have comments or questions concerning pro—
posals in this letter, please contact me. We would appreciate your prompt
response to this letter in order to provide sufficient time for preparation
of drawings for consideration of the January Planning Board hearing.
Sincerely,
RBD, INC.
,Lloyd G. McLaughlin
LGM/kac
Enclosure
cc: d. Jensen Enterprises
Cityscape: Urban Design
DATE
• DEPARTMEN
ITEM: AMENDMENT TO DIXON CREEK PUD #144-80B
COMMENTS
Z-� eU� 71-Z)
/j
4 a�
G.
_
CITY O[ FOR I COLT INS P O. BOX 580, FORT C:OLLINS. COLORADO 80522 1303) 484-4220
PLANNING and DEVELOPMENT DEPARTNUNT EXT.652
December 21, 1983
Mr. Eldon Ward
CITYSCAPE URBAN DESIGN
419 Canyon, Suite 300
Fort Collins, Colorado 80521
Dear Eldon:
Staff has reviewed the proposed amendment to Dixon Creek PUD. The following
comments pertain to both the proposed amendment area, as well as the remainder
of the site, since the original plan will expire in the near future and the
proposed density is being calculated based on the entire site:
1. Final resolution of the extension of public sewer to service the site is
necessary.
2. Building setbacks of 15 feet are needed to install utilities outside
paved or concreted areas. These areas need to be designated utility
easements.
3. An additional fire hydrant is needed in condo area 1.
4. All lot dimensions need to be shown on the site plan. All building
envelope dimensions and distances to property lines must be shown on the
site plan.
5. Tennis courts need to be within a building envelope and the height and
materials of the proposed fence need to be specified.
6. Typical dimensions for compact stalls need to be indicated. Some stalls
appear to scale less than 15 feet in length.
7. Motorcycle parking should be provided in the condo areas.
8. The attorr.ey's certification statement needs to be revised.
9. Calculations specifying the proposed energy savings need to be provided
to evaluate the density credit.
10. Additional landscaping should be provided along the Drake frontage of the
open space tract near Lot 29.
Mr. Eldon Ward
From: Sherry Albertson -Clark
December 21, 1983
Page Two
11. A full 19 foot stall (or 0 feet) is required behind garages (page 4 -
building 10 area).
12. Continuation of sidewalks to the end of Skimmerhorn Court would provide
more direct access to the volleyball courts and picnic shelter.
13. A pedestrian link from Pasquinel Drive to the interior open space area
near the volleyball court would provide a more useable active open area
for patio home area 3.
14. The landscaping for the active open area at Drake and Pasquinel (pages 7
and 9) are somewhat different.
15. Buildings 6 and 7 of townhome area 3 are not within 150 foot of fire
access, since the units' addresses would be on Skimmerhorn.
16. The number of parking spaces at the west end of Skimmerhorn Court are not
consistent on pages 6 and 7.
17. At the 3rd parking lot entrance west of Pasquinel Drive into condo area 1
(page 8), the first parking stall opposite the parking lot entrance
should be deleted to avoid congestion at the area's entrance.
18. Setbacks between parking areas and sidewalks along Overland Trail are
virtually non-existent, providing minimal opportunities for screening
from a future 6-lane arterial.
19. Additional landscaping should be provided to buffer the active open area
along Overland Trail and Skimmerhorn Street.
20. It is not clear how the typical landscaping proposed for around the
townhome and condo units relates to landscaping shown on the overall
landscaping plans. Who would be responsible for the installation of such
landscaping? Are these plants included in the planting schedule?
21. The distribution of active open space for the number of units in condo
area 1 is disproportionate (i.e., 8% of active open space for 35% of
total d.u.'s).
22. Sidewalks in condo area 2 should be adjacent to parking stalls without
any space between (page 10).
23. Landscaping along Skimmerhorn Street (along active open area) and
Pasquinel Drive (pages 9 and 11) is minimal.
24. Page 3 indicates manual irrigation of landscaped islands, while page 1
shows automatic irrigation systems. Which is correct? Manual irrigation
of so many areas would be difficult.
25. The active open area on sheet 11 along Overland Trail needs to be
defined.
Mr. Eldon Ward
From: Sherry Albertson -Clark
December 21, 1983
Page Three
26. The following items on the Density Chart do not appear to earn credit for
the site:
a. Neighborhood park, community park or facility.
b. Off -site open space dedication.
Since 80°0 of the units are within 650 feet of the transit route, the site
earns 8% rather than 10%.
27. A traffic impact study showing impact of new density is required.
28. Patio home garages should have a full 19 foot stall behind them. A note
should be placed on the site plan specifying this requirement.
29. Standard curb cuts need to be shown, rather than curb returns.
30. All streets and r-o-w's must be dimensioned (see Dumire Court, Seccumb
Court, Yorkshire Street, Lucinda Court, Brumbaugh Drive, Pasquinel Drive,
Skimmerhorn Street and Court, Zendt Court, Clemma Court, McKeag Drive).
31. Sidewalks need to be dimensioned. The sidewalk on Drake must be redesign-
ed to current City standards. Handicapped ramps must be shown at inter-
sections and in parking lots. The walk on Skimmerhorn (page 8) is attach-
ed and needs correcting near the Overland intersection.
32. Easements need to be shown on the site plan.
33. All cul-de-sac islands need to be dimensioned.
34. All 900 parking along streets needs to be concrete to the property line.
35. The location of "No Parking" signs needs to be indicated.
36. Parking stalls near building 7-D and building 1-C (page 2) and those east
of Pasquinel on page 6 are too close to garages. Compact stalls could
gain additional space.
37. Backup areas need dimensions. The 5 foot backup east of Yorkshire, near
McKeag is too close to the street. Shifting garages east could gain
additional space.
38. Walks in townhome areas from garages and parking stalls should be shown.
39. Edge treatment of parking areas utilizing the 2-foot overhang needs to be
specified (i.e., curb and gutter, wood timbers, etc.).
40. Radii in the condo area 1 parking lot do not meet fire requirements. The
islands need to be cut back.
41. ThS condo area 2 parking lot south of Pasquinel needs to be designed with
90 intersections for fire access.
Mr. Eldon Ward
From: Sherry Albertson -Clark
December 21, 1983
Page Four
42. The curb cut south of Skimmerhorn on Pasquinel must be at a 900 inter-
section with Pasquinel. Parking stalls in this area should either be all
standard or compact, rather than mixed.
Fifteen copies of the revised site plan reflecting these comments must be
s ,=.tt., to t� i s off ce by Monday, January 9, 1984. By Monday, January 16,
1934, coltre�' site plans and 82"xll" PMT's must be submitted. If you have any
-e din 'nese comments, please do not hesitate to contact me.
Sirxceejky,
Sherry Alber on -Clark
Senior C i `y 1 ann er
i
Sz,C: ro
cc: Bonn? e Tripoli, Development Coordinator
DATE a '�'� DEPARTMEN f
ITEM: Oxi)/J
COMMENTS
v
40P-j 1, --,*2
o a��
z�:j ID r &J�
7
-7 / _ 4-0- J --f .
-,- q DEPARTMEN-
RECEIVED
MAR i 1 1984
DEPART
pit,
DEPARTw,
M'`M7N .
a
M E N T
4LL EASEMENTS AREAE To 13E-Sf/awN �5
;eeaLLESTED - AJo 0rge2 commENT-s .47T Ir41s -rIM
T COLLINS P.O BOX 580, FORT COLLINS, COLORADO 80522 PH (303) 484-4220
CITY OF FOR
PLANNING DIVISION EXT. 655
MEMORANDUM
DATE: April 13, 1981
TO: Eldon Ward, ZVFK Architects/Planners
FROM: Sherry Albertson -Clark, Planner -,'��
SUBJECT: Dixon Creek Utility Coordination Meeting, April 10, 1981
h:eeting Attendees: Josh Richardson, Development Engineer
Rich Stengaard, Public Service Company
Lloyd McLaughlin, M&I, Inc.
Doug Martine, Light & Power
Bruce Vogel, Light & Power
Michael Lawson, M&I, Inc.
Eldon Ward, ZVFK Architects/Planners, Inc.
Dan Jenson, D.Jenson Enterprises
Brian !good, Columbine Cablevision
Howard Lench, Mountain Bell
Sherry Albertson -Clark, Planning Division
Jim Hibbard, Water & Sewer
Webb Jones, Water & Sewer
A record of the comments made at the April 10, 1981 Utility Coordination Meeting
are as follows:
1. Light and Power requests blanket utility easements in open space areas.
Service will not be run to units with more than four units. In some cases,
the developer may need to run the utility services. An additional 6-feet
is needed along both sides of the 24-foot drive. Additional costs will be
paid by the developer if utilities are installed under asphalt.
2. Public Service Company requires a 15-foot clear setback behind sidewalks.
3. The first construction phase will be in the northeast corner of the site.
Water lines in this area must be looped or oversized.
4. Mountain Bell would like blanket utility easements in open space areas.
5. A preliminary utility layout will be submitted for Water and Sewer to
review.
SAC/fsr
cc: Josh Richardson - Development Engineer
Curt Smith - Planning Director
CITY OF FORT COLLINS
COMMUNITY DEVELOPMENT DEPARTMENT, PLANNING DIVISION
September 27, 1985
Dan R. Jensen, President
Jensen Homes
P.O. Box 1007
Fort Collins, Colorado 80522
RE: DIXON CREEK PUD AMENDMENT (CASE #144-80B) - SIX MONTH EXTENSION
REQUEST
Dear Mr. Jensen:
Staff has reviewed the above referenced matter and has the following
comments:
1. City staff can only grant successive six month extensions to PUD's.
After the second six month extension, the matter is brought before the
Planning and Zoning Board. This extension request would be for six months
from the date of approval.
2. At this time, Staff cannot grant a six month extension until the
plan is brought up to current City standards. Particular items are as
follows.
3. Sidewalks are now required on both sides of all streets.
4. Pedestrian access ramps are required at all corners.
5. A seven foot walk along arterial streets if it is attached.
6. Current site design includes medians in arterials.
7. No patterned concrete is allowed in public streets.
8. Handicap spaces need ramps and need to be shown.
9, A street width of 36' is required where single family dwellings
double -front the street.
DEVELOPMENT, PLANNING DIVISION
10. Public Service Co. of Colorado requires a 15' wide space between
front of buildings and back of sidewalks to allow for installation and
maintenance of water boxes, power and natural gas outside of paved areas.
This 15' space needs to be dedicated as street right-of-way and or utility
easement.
These items need to be addressed and shown on updated plans before an
extension request can be granted. Please submits these plans on October
29, 1985 for review by City staff. A decision will be made sometime in
December as to the status of this extension request. If you have any
questions concerning these engineering comments, please contact Bonnie
Tripoli in our office. If you have further comments or questions
concerning this matter, please do not hesitate to contact me.
Sincerely,
Ave �,l lr
Steve Ryder
City Planner
cc: Bonnie Tripoli, Development Coordinator
CITY OF FORT COLLINS
PLANNING DIVISION
October 21, 1981
P.U. BOX 5SU, fUKI UULLIfNJ, LULUKAUU bvDGG rn -to-t-k44U
EXT. 655
Mr. Eldon Ward
ZVFK Architects/Planners
218 W. Mountain
Ft. Collins, CO 80521
Dear Eldon:
Staff has reviewed the final site and landscape plans submitted for Dixon Creek
and has the followng comments to make:
Building setbacks from rear of sidewalks or curbs along all streets must be
+^' at least 15-feet to allow for utility installation. This space msut be desig-
nated as a utility easement or a combination of utility easement and dedicated
right-of-way. Fifteen foot easements are also needed along Drake Road and
Overland Trail. A repay will be due for the water line in Drake Road.
2. Cul-de-sac bulbs must be posted as "No Parking" areas. The Fire Authority
tt OP _ has requested several fire hydrant relocations. Contact me regarding these
` locations.
3. Garages in the townhome areas must be in building envelopes. Patio home lots
must have lot: line and building envelope dimensions shown. For clarification,
the property line should be indicated along all streets.
4. Building envelopes in the condominium and townhome areas must have dimensions
to at least two property lines shown.
5. Any roof overhang or projection beyond a lot line or building envelope must
be in an easement which specifically mentions the type of projection and the
limits of the projection allowed in the easement.
6. Trash enclosures must be shown and the composition of these enclosures
specified.
7. Are "identity structures" signs? If so, they must comply with the Sign
Code.
8. Fencing behind units in multi -family areas must not interfere with the 150-
foot fire requirement.
Mr. Eldon Ward
ZVFK Architects/Planner,-
October 21, 1981
Page Two
9. "Venneford Drive" must be changed to "Yorkshire" or approval to change
"Yorkshire" must be obtained. The island shown at this street's intersection
with Drake Road must be deleted.
10. To facilitate addressing, "Michener" and "Seccomb" Courts must be one name.
All units in c:omdominium and townhome areas that access off of private drives
will be given one address. The developer will be responsible for numbering
individual units in these areas.
11. Dimensions for cul-de-sacs and parking areas must be shown.
12. Patterned concrete, if used, must be carried throughout the entire intersection.
These partially concreted areas cause maintenance and drainage problems. The
site plan should also show concrete -surfaced curb cuts from flowline to
property line.
13. Islands in cul-de-sacs must be provided with drip irrigation or drainage
structures.
14. A "No Parking" side must be designated on all 28-foot streets. This should
be on the side where sidewalks are located.
15 Why are 28-foot streets not centered within the right-of-way? A variance
for this must be requested.
16. Temporary cul-de-sacs must be provided on "Yorkshire" and "McKeag."
17. Queing spaces behind garages in townhome areas must be 19-feet long or short
enough to discourage overhang into the access drive (i.e., 4-feet or less).
Of particular concern are the garages in townhome Area 4 that access off
of Pasquinel Drive and any other area where overhang could interfere with
fire access.
18. It was staff's understanding that a provision for a public trail along Dixon
Creek would be included, rather than in the area south of Skimmerhorn Street.
Please clarify your position on this.
19. Common open space areas need to be delineated on the site plan.
20. Lighting must: be provided in the multi -family area parking lots.
21. Typical landscaping 'schemes within townhome and flat envelopes need to be
shown.
22. Several parking spaces in condominium Area 1 appea;.r to encroach on the
sidewalk. The parking areas that are parallel to Overland Trail in this
area are not adequately screened from the street.
23. The type of ground cover and irrigation of common open space areas needs to
be specified.
Mr. Eldon Ward
ZVFK Architects/Planners
October 21, 1981
Page Three
Ten copies of the
in this office by
November 9, 1981.
feel free to call
Si ncerely,
'revised site plan addressing these comments need to be received
November 2, 1981. Reductions and colored renderings are due
If you have any questions concerning these comments, please
me.
Sherry Albertson -Clark
Planner
SAC/fsr
cc: Curt Smith, Director of Planning & Development
Josh Richardson, Development Engineer
ZVFK architects/planners
a professional corporation
218 west mountain avenue
tort collins, co 80521 usa
telephone 303 493-4105
January 6, 1982
Sherry Albertson -Clark
City of Fort Collins
Planning Division
P. 0. Box 580
Fort Collins, CO 80522
Dear Sherry,
We have made revisions to our site and landscape plans in response
to staff comments on Dixon Creek final P.U.D. Our specific responses
are as follcws:
1. The requested larger easements along Drake Road and Overland
Trail have been added. Easements along all internal streets
have been modified to be consistant with those shown on the
approved preliminary street cross sections.
2. The private cul-de-sacs in the townhome areas have been noted
as no parking except in designated spaces.
3. The garages, multi -family envelopes and patio home envelopes
are done according to systems acceptable to and requested by
the Building Department.
4. For additional clarity, more notes and dimensions have been
added to the building envelopes in the multi -family areas.
5. A note covering eaves and access for maintenance and utilities
on patio home lots has been added to the site plans.
6. A note specifying minimum treatment of trash enclosures has
been added to the plan.
7. The identity structures will comply with the sign code as noted
on the site plan.
8. A note on fencing restrictions relating to fire access has been
added.
9. The street name and intersection design have been revised as
requested.
10. "Michener Court" has been changed to "Seccomb Court".
11. Exact design and dimensions of public cul-de-sacs are included
in the utility plans. The parking areas are also dimensioned
on our site plans.
12. Patterned concrete crosswalks have been eliminated on Yorkshire
as requested.
13. Islands in cul-de-sacs will be irrigated.
14. A "No Parking" side has been designated on the 28' streets.
15. The 28' local streets are off set in the right-of-way (exactly
as approved in the preliminary street cross sections) to leave
equal landscaped right-of-way and easement on both sides. A
variance has been granted.
16. A temporary cul-de-sac has been shown on Yorkshire. This cul-
de-sac would be required for emergency access only if townhome
area #4 were built out before the street is extended south. As
we discussed, there is no real need for a temporary cul-de-sac
on "McKeag".
17. Driveways and garages have been amended as requested.
18. On June 24, 1981, 1 met with Randy Balok of Parks and Recreation.
After looking at the area wide trail system it was our mutual
agreement that the trail would function better at the location
shown on our final site plans.
19. We have now indicated active open spaces and their areas on site
and landscape plans.
20. Lighting will be provided in parking areas. Specific locations
of lights will be determined upon application for building
permits. A note to that effect has been added to the plan.
21. Typical close -in landscape treatments for the various building
types Has been illustrated. Please note that this is a commit-
ment to a minimum level and general approach to this portion of
landscape treatment. Because of differing building orientation
and for• the sake of variety, specific species and minor details
will vary in actual installations.
- 2 -
22. Curbs in the condominium areas are placed to act as wheel stops.
Walks are set back to avoid conflicts with car overhangs. More
notes, dimensions, and landscaping have been added to our plans.
23. Notes covering turf grasses and irrigation systems have been
added to landscape plans.
Ten copies of our revised plans are attached. We are anticipating
being on the consent agenda for the January 25th Planning and Zoning
Board Meeting..
Thank you for your service in the review of this plan.
Sincerely,
Eldon Ward
EW/jb
cc: Dan Jensen
Lloyd McLaughlin
- 3
MOOING
Engineering Consultants
Drake Terrace Suite 240
343 West Drake Road
Fort Collins. CO 80526
303/226-4955
December 5, 1983
City of Fort Collins
Development Center
P.O. Box 580
Fort Collins, CO 80522
RE: Amendment to Dixon Creek P.U.D. Utility Plans
This letter is submitted to address comments concerning modifications to
the utility plans for the amendment to Dixon Creek P.U.D. The area under
consideration consists of Tracts 1, 2, 5, 6, and 7 of the Dixon Creek
P.U.D.
Please reference existing utility plans prepared by M & I Consulting Engi-
neers approved by the City on January 21, 1982.
We have enclosed Sheet 24 of the above referenced drawings. Modifications
to accommodate the site plan as proposed by Cityscape Urban Design are
indicated in red. These modifications by Tract are as explained below.
Tract 1:
It is proposed to eliminate the need for water and sewer mains from M.H. 15
to M.H. 61 and reroute service lines as shown. One building pad has been
deleted.
Tract 2:
One building pad is deleted therefore services are to be deleted also.
Tract 7:
Two building pads have been eliminated. It is proposed to delete the water
and sewer mains from M.H. 11 to M.H. 58 and reroute services as shown.