HomeMy WebLinkAboutCOLLINDALE BUSINESS PARK - Filed CS-COMMENT SHEETS - 2003-07-315c-
DATE:,Jun ae DEPARTMENT: e n9
ITEM: 7-82B COLLINDALE BUSINESS PARK PUD
No Problems
Problems or Concerns (see below)
• L 06-:31 C/U p 70,-J �A5 AN
fb
1�lNo� DRt=TNc� Cy4N��J✓!%/, v.s
• /�^�� 7-7) 12e,91C1,r,— 57',) a/TzOe �CAt'` $ 0 U,)
tJ d'C-9 L) T7 L / 71 P4-�—.5 -3-IRWi!rr p&316,j
Date Signature
lDevelc tent Services
Planning Department
City of Fort Collins
June 22, 1988
John Barnett
ZVFK Architects
11 Old Town Square Suite 200
Fort Collins, CO 80524
Dear John:
Staff has reviewed the Preliminary PUD submittal for Collindale Business Park
and has the following comments:
1. There is an existing sewer manhole in Timberline Road at the intersection
of Timberline and Caribou. A sewer main must be extended from that
manhole., west in Caribou. The main should be sized to handle sewage
flow as far west as the UP Railroad right-of-way. A repay is due for the
Warren ]Lake Trunk Sewer.
2. There is an existing 16" water main in Timberline. A new water main
must be extended from that water main, west in Caribou.
3. Water and Sewer requests that a Master Utility Plan be submitted.
4. A minimum of 9-1/2' is requested for the installation of Light and Power
facilities and street trees along Timberline and Caribou. An additional 2'
of space will be necessary to allow Light and Power to work around exist-
ing Public Service poles shown on Timberline.
5. There is an existing 8" intermediate pressure gas line in Public Service
Company's Easement Document #145538 that does not show on the prelimi-
nary plat. No trees or fences will be allowed on this easement. Service to
this development will not come from this intermediate pressure feeder, but
from the 3" distribution pressure line in the Timberline right-of-way.
6. An 8' wide utility easement adjoining the north right-of-way line of
Caribou Road needs to be shown on the plat and dedicated.
7. There is a Public Service Company overhead power line along the west side
of Timberline Road. State law requires that a minimum of 10' of clear-
ance be maintained between overhead conductors during any and all activi-
ties.
300 LaPorte Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (303) 221-6750
Page 2
8. The building as proposed does not meet the 150' fire access requirement.
If this requirement is not met, the building must be sprinkled.
9. Two fire hydrants will be required: one at the north entrance and one at
the southwest corner at the extension of Caribou Road.
10. A complete storm drainage report must be submitted, including proposed
and existing contours, all drainage outfalls to major drainageways, site
detention calculations, sub -basin delineations with associated runoff rates to
the centerline of the adjacent streets, high waterline of the 100-year
detention limits, sizing calculations for initial storm sizing of structures
and all other requirements as per city storm drainage manual.
11. A Master Drainage Plan for the entire development must be submitted.
12. Utility plans must be submitted for the proposed street design.
13. Dedication and construction of Caribou and Timberline will be required.
An additional 20' of r-o-w must be dedicated for Timberline Road.
14. There are minor errors in the legal description and drafting changes and
additions. This information is being conveyed by redlines on the attached
site plan.
15. A building envelope with dimensions must be shown on the site plan. The
distances from the envelope to property lines must also be shown.
16. Motorcycle parking must be provided.
17. All signs must comply with the sign code.
18. Landscaping in the public right-of-way along Timberline will be maintained
by the developer.
19. A Traffic Impact Analysis must be submitted. Until this analysis is
submitted and reviewed by the City Traffic Engineer, staff cannot make
specific comments regarding the site access and circulation. Please be
aware that access and circulation comments from staff will be forthcoming
once a Traffic Impact Analysis is submitted for review. The extent of
off -site improvements will also be determined by the Traffic Impact
Analysis.
20. Sidewalks along Timberline should be 7' wide. The walks along Caribou
need to be separated at least 10' or be attached.
21. Additional attention is recommended to the proposed landscaping in the
following areas: north and west property lines; at site entry at Caribou
and building foundation.
22. Proposed wareyard screening materials and height should be indicated.
23. Pedestrian connections from the building to Timberline should be consid-
ered.
Page 3
24. Information regarding existing conditions within 150' of the proposed site
needs to be shown on the site plan.
25. The PUD ordinance requires that property intended to be developed
over time in two or more separate preliminary plan submittals requires a
Master Plan. Since the site plan is labelled as "Phase One", it appears that
a Master Plan is required to be submitted and reviewed along with the
proposed phase plan.
26. Point Chart E needs to be re-evaulated. Staff analysis shows the maximum
applicable points would be 48. If points are to be considered for energy
conservation, information to substantiate the planned energy improvements
must be submitted for review. Information regarding the use of the
contiguity criteria should also be provided.
By noon on Wednesday, July 6, 1988 three copies of the revised site plan
reflecting the above comments must be submitted to this office. Items that
cannot be addressed graphically should be provided in written form. By
Monday, July 18, 1988 ten (10) unfolded sets of plans, a colored rendering
(unfolded) and 8-1/2"x 11" PMT reduction (or similar quality, zerox copies are
unacceptable:) must be submitted.
If you have any questions or would like to meet to discuss these comments,
please do not hesitate to contact me.
Sincerely,
Sherry Albert on -Clark
Senior Planner1�,
V
cc: Joe Frank, Assistant Planning Director
Mike Herzig, Development Coordinator
file
Enclosure
DATE: a Aug aa DEPARTMENT: C�
ITEM: 7-82B LOLL INDALE BUSINESS PARK
No Problems
_ Problems or Concerns (see below)
Devc )ment Services
Planning Department
Citv of Fort Collins M E M O R A N D U M
TO:
BOB SNOW LvV
ENGINEERING
12411, W. Magnolia
Fort Collins, CO 80521
FROM: Mike Herzig, Development Coordinator
DATE: April 25, 1989
RE: Subdivision Utility Plans
Submitted for your review and comment are utility plans for:
COLLINDALE BUSINESS PRK
Please respond by:
Tuesday, May 9, 1989
Ll-
�!O L<Worte :Avenue • P.O. 13o\ Fort Collins. CO Sl)7)?=-O7 i80 • i, ,031 211-.,-,.1
1Jevr pment Set -vices
Planning Department
M E M O R A N D U M
I
k
TO:
GARY HUETT
PUBLIC SERVICE
FROM: Mike Herzig, Development Coordinator
DATE: April 25, 1989
RE: Subdivision Utility Plans
Submitted for your review and comment are utility plans for:
COLLINDALE BUSINESS PRK
Please respond by:
Tuesday, May 9, 1989
C.
t 5 Q,K CN-I5f Lj 3 6 a 5 I �%1'L IY 1VK` eA-�yc-,
I west ate..,
on e h ruse wo-w � T►,w, �.c.
wft 7 o T Kt wt4 j g v • W • Cr
e W -s u,porrt . Q
reou1 rely . pub (; e, 5e rvrm eo,,76�
ktm of 5e, i wee, OT l- r — ci
1,uV ;'0 • F t Cull S, CO 103':-O;SO - 1 ;(UI ��:-